| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹25.3 L+₹3.3 L (14.9%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | Not Admitted-Fee/PreQual/Technical 68 16 STANLEY ROAD INDRAPRASTHA COLONY ALLAHABAD UTTAR PRADESH 211002 | PRAYAGRAJ | UTTAR PRADESH | 211002 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | KHAN ENTERPRISES L2 | M/S PRAKHAR ELECTRIC WORK L1 |
|---|---|---|---|---|---|
| 1.00 | ST Pole 11 Mtr. Long | 42 | Nos. | 21,000 ₹28,460.4 | 21,000 ₹24,780 Lowest |
| 2.00 | PCC Pole 8.5 Mtr. Long | 42 | Nos. | 4,400 ₹8,334.56 | 3,200 ₹3,776 Lowest |
| 3.00 | Stone Pad (300x300x75 mm) | 84 | Nos. | 50 ₹260.62 | 10 ₹11.8 Lowest |
| 4.00 | Top channel (125x65x2240mm) | 4 | Nos. | 2,000 ₹2,624.8 Lowest | 2,700 ₹3,186 |
| 5.00 | Dropper channel (100x50x2028mm) | 4 | Nos. | 2,000 ₹2,524.8 Lowest | 2,200 ₹2,596 |
| 6.00 | V-Type Steel cross arm with clamp | 19 | Nos. | 1,000 ₹1,312.4 Lowest | 1,300 ₹1,534 |
| 7.00 | 11 KV Pin insulator with pin complete | 69 | Nos. | 300 ₹463.72 | 200 ₹236 Lowest |
| 8.00 | 11 KV Disc insulator with fitting | 30 | Nos. | 300 ₹413.72 Lowest | 500 ₹590 |
| 9.00 | LT Clamp with nut & bolts for PCC Pole with neutral | 56 | Nos. | 300 ₹413.72 | 250 ₹295 Lowest |
| 10.00 | M.S. Angle (75x75x6x2028mm) (T/F Base) | 6 | Nos. | 2,500 ₹3,081 | 1,800 ₹2,124 Lowest |
Tender Value
₹1.9 Cr
EMD Value
₹1.9 L
Closing Date
13 Apr 2023, 1:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC-II ALIGARH
ALIGARH
EDC2A-46/2022-23
2023_DVVNL_773108_4
EDC2A-46/2022-23
Open Tender
Electrical Works
Turn-key
90 days
IGLAS
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
DVVNL AGRA WEBSITE (dvvnl.org)
₹1.9 L
18 Apr 2023
8 Apr 2023
13 Apr 2023
8 Apr 2023
13 Apr 2023
8 Apr 2023
Amount
ST Pole 11 Mtr. Long
PCC Pole 8.5 Mtr. Long
Stone Pad (300x300x75 mm)
Top channel (125x65x2240mm)
Dropper channel (100x50x2028mm)
V-Type Steel cross arm with clamp
11 KV Pin insulator with pin complete
11 KV Disc insulator with fitting
LT Clamp with nut & bolts for PCC Pole with neutral
M.S. Angle (75x75x6x2028mm) (T/F Base)
M.S. T-off channel with clamp B&N (100x50x1300mm)
F-Bracket for fitting top channel
Holding Clamp with bolt nut
Danger Board with clamp N&B
Stay Complete
Earthing Complete
Distribution Box with clamp
ABC 3x95 + 1x70 + 1x16 Sq.mm.
ABC 3x120 + 1x95 + 1x16 Sq.mm.
End Clamp
Eye Hook with suspension clamp
LT Insulator with pearsing
Bolt, Nut & Washers
11/0.4 KV 400 KVA Transformer
11/0.4 KV 100 KVA Transformer
11/0.4 KV 250 KVA Transformer
11/0.4 KV 63 KVA Transformer
LT XLE Cable AL. 1x400 Sq.mm.
LT XLE Cable AL. 3.5 x 240 Sq.mm.
PVC Cable 3.5*x70 Sq.mm.
11 KV VCB O/G CTR 200/100/5A 350 MVA
Phase wire ACSR Dog Conductor
Body and neutral earthing of following L.T. distribution Transformers installed by digging of pit up to water level depth (approx. 100’) and then inserting 1-1/4" dia G.I. pipe of "B" grade, conforming to the requirement of IS specification and then connecting the top of the inserted pipe and transformer body through GI strip of size 50x6 mm with the help of nut and bolt or through gas welding, as per direction of supervising engineer including the cost of arrangement of all material, labourer, T&P, carrier etc. required for proper completion of work.
11/0.4 KV 400 KVA Transformer
11/0.4 KV 250 KVA Transformer
11/0.4 KV 63 KVA Transformer
Construction of following Transformer of Plinth of size 5’x5x4’ above ground level and one ft. below the ground level of 9”. After excavation of 4” earth, brick ballast shall be provided and rammering will be done properly after that a retaining wall of 9” width by first class brick in ratio 1:4 of cement and sand shall be made. The earth shall be filled up to one ft. below the top of the plinth. After this brick ballast shall be provided up to 6” from the earth level and proper rammering shall be done. One No. jall of 12 mm M.S. tor shall be fixed in the hollow of plinth and one ft. thick RCC in ratio of cement, sand and stone ballast shall be laid on the top of the Plinth. The 12 mm thick plastering shall be done all around the plinth in 1:4 ratio of cement and sand. The contractor shall be responsible to complete the work as per direction of Supervising Engineer. It including the cost of all material, labour T&P, carrier etc. required for proper completion of work.
11/0.4 KV 400 KVA Transformer
11/0.4 KV 250 KVA Transformer
11/0.4 KV 63 KVA Transformer
FABRICATION & ERECTION OF FENCING AND CONSTRUCTION OF RETAINING WALL AROUND FOLLOWING CAPACITY T/F The complete 11/0.4 KV Substation shall be provided with two meter height fencing and retaining wall around the substation. One No. Gate with proper locking arrangement for entry of personnel shall also be provided. The fencing shall be made of 50x25 mm x10 SWG rectangular welded mesh of wire mesh in length. Wire mesh shall be fixed on panels made of 50x50x6 mm M.S. Angle. The wire mesh on panels will be supported by 25x3 mm M.S. flat on all the bracings diagonally and 50x6 M.S. Flat horizontally at the center of the panel. The panel will be joined by bolts & nuts of appropriate size with each other and on the main support on corners including supply of all material, labour, carrier and T & P etc. required for proper completion of work. The painting of complete fencing shall also be done with one coat of red oxide primer and two coat of synthetic green paint. For construction of retaining wall around the fencing, excavation of earth shall be done in foundation in ordinary soil including disposal of surplus earth at some suitable distance. The dimension of excavation shall be 1m wide, 0.45 m deep and suitable length as per wire mesh. After excavation of earth a cement concreted pad shall be laid in foundation. Concreting shall be done with Ist class brick ballast, coarse sand and cement in proportion of 8:4:1. First class brickwork shall also be done in foundation and super structure in 1:6 Cement and coarse sand including necessary cutting and moulding of bricks in foundation depth of wall 0.30 m, thickness of wall 0.35 m & superstructure brick work thickness of wall 0.23 m & depths 0.30 m including supply of all material, labour, carrier and T & P etc. required for proper completion of work.
11/0.4 KV 400 KVA Transformer
11/0.4 KV 250 KVA Transformer
11/0.4 KV 63 KVA Transformer
Demounting & carriage of following capacity transformer due to overloaded including the work of its loading & unloading, dragging etc. and also including the cost of labour and T&P etc. required for proper completion of work.
11/0.4 KV 100 KVA Transformer
11/0.4 KV 250 KVA Transformer
11/0.4 KV 25 KVA Transformer
Dismantling and removal of existing conductor/cable/GI Wire from the various area preparing their coils and then stacking in the respective JE’s (Store) as per direction of Supervising Engineer. It includes the work of cartage, cost of labour, T&P carrier etc. required for proper completion of work.
ABC 3x120 + 1x95 + 1x16 Sq.mm.
Concreating of Pole
Concreating of Stay
Guarding of 11 KV line by laying two nos. GI wire parallel and fixing of lacings (tilli) at a distance at 2-3 Mtr. as per RESPO manual and also including the cost of arragement of labour, T & P etc. required for proper completion of work.
Dismanteling of old damaged 11 KV VCBs (O/G CTR 200/100/5A 350 MVA) after opening its 11 KV cable connection removing earthing bus bar CTs and taking it out side switch yard. the work of cartage, cost of labour, T&P carrier etc. required for proper completion of work.
KHAN ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
Tender Document • 0.15 MB
CORRIGENDA ADDEMDA To FORM-A.doc
Tender Document • 0.11 MB
FORM-B.docx
Tender Document • 12.99 MB
TPMO-Horizontal type.doc
Tender Document • 3.26 MB
Danger board.docx
Tender Document • 3.07 MB
Technical Specification.docx
Tender Document • 0.52 MB
2. 11kV GI pin.docx
Tender Document • 0.35 MB
11 KV Bank (1.98 _ 3.96 MVAr).pdf
Tender Document • 0.23 MB
2. Porcelain Disc Insulator 45 KN.DOC
Tender Document • 0.23 MB
ACSR Conductors.DOC
Tender Document • 0.22 MB
11 KV Pin Insulator over head line.DOC
Tender Document • 0.22 MB
01. General Technical Specification.doc
Tender Document • 0.22 MB
1. Disc Insulator B_S 70 KN.DOC
Tender Document • 0.22 MB
2. Disc Fitting 45 KN (T_C) type.DOC
Tender Document • 0.22 MB
Battery _ battery charger.DOC
Tender Document • 0.22 MB
Civil Work for 33 KV SS.doc
Tender Document • 0.21 MB
G.I.-GSS Wires.DOC
Tender Document • 0.21 MB
1.-33 KV VCB.doc
Tender Document • 0.20 MB
1. 33 KV G.I pin.DOC
Tender Document • 0.20 MB
1. Disc Fitting 70 KN (B_S) type.DOC
Tender Document • 0.20 MB
1. Technical_Spec for 11 kV VCB Switchgear.doc
Tender Document • 0.18 MB
General Conditions of Form-A.DOC
Tender Document • 0.11 MB
11 KV _V_ Type X-arm.rtf
Tender Document • 0.11 MB
9.0 M LONG PCC POLES OF 400 KG.doc
Tender Document • 0.10 MB
33 KV Cross Arm.rtf
Tender Document • 0.10 MB
Schedules (A to K_ M _ Q).DOC
Tender Document • 0.09 MB
5. -Control Cable.doc
Tender Document • 0.08 MB
1. Specs 33KV -Straight Thru Joints.doc
Tender Document • 0.07 MB
General Requirement of Specification.doc
Tender Document • 0.07 MB
1. TECHS_1.DOC
Tender Document • 0.07 MB
GENERAL SPECIFICATION FOR WORKS.docx
Tender Document • 0.06 MB
2. Specs 33KV -Terminations.doc
Tender Document • 0.06 MB
PQR AND TERMS _ CONDITION.docx
Tender Document • 0.06 MB
1. Specs-11KV.doc
Tender Document • 0.06 MB
2. Stay set 16x1800..doc
Tender Document • 0.06 MB
Instruction for e-tender.docx
Tender Document • 0.05 MB
1. Stay set 20x1800..doc
Tender Document • 0.05 MB
2. GTP.doc
Tender Document • 0.05 MB
GUY STRAIN INSULATOR.doc
Tender Document • 0.04 MB
PERFORMA-A (COMPULSORY).docx
Tender Document • 0.04 MB
2. GTP 11 kV.doc
Tender Document • 0.04 MB
3. GTP-33KV.doc
Tender Document • 0.04 MB
2. Earthing Rod.doc
Tender Document • 0.04 MB
BG 10_ Performance Security.doc
Tender Document • 0.03 MB
1. GROUNDING SYSTEM.doc
Tender Document • 0.02 MB
Aluminium paint.docx
Tender Document • 0.02 MB
_ Disc Insulator B_S 70 KN.DOC
Tender Document • 0.00 MB
_ Porcelain Disc Insulator 45 KN.DOC
Tender Document • 0.00 MB
_. General Technical Specification.doc
Tender Document • 0.00 MB
BOQ_1328132.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .