Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance F 23 B FIRST FLOOR VARDHMAN CENTRAL MALL LSC NEHRU VIHAR MUKHERJEE NAGAR NORTH DELHI DELHI 110054 | CENTRAL DELHI | DELHI | 110054 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance B 2 46 SECTOR 18 ROHINI DELHI 110089 | DELHI | NORTH WEST DELHI | DELHI | 110089 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹60.7 L
Closing Date
25 Mar 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
General Manager (CP)
2nd Floor, RITES Bhawan-II, Plot No. 144, Sector-44, Gurgaon- 122003
Design, Supply, Installation, Testing and Commissioning of VRV/VRF type Air conditioning system for New Academic Block and Extension of Existing Science Block at Shivaji College, New Delhi
2021_RITES_72813_1
RITES/CP/Shivaji College/AC/21
Open Tender
Electrical Works
Works
180 days
Shivaji College, New Delhi
Please refer Tender Document
5 documents required · 5 mandatory
₹2,500
RITES Ltd
Exempted
26 Mar 2021
11 Mar 2021
26 Mar 2021
11 Mar 2021
25 Mar 2021
18 Mar 2021
12 Mar 2021 - 16 Mar 2021
90 days
Amount
Total Amount of BoQ 2
Amount after unconditional Rebate
Description of Work / Item(s)
Amount
Notes: 1) The design of the HVAC System is covered under the scope of work. The contractor shall design the HVAC System including heat load calculation and shall be responsible for maintaining the inside temperature condition as stipulated in the tender. 2) The BOQ item shall be read in conjunction with technical specifications. 3) The bidder/Contractor shall make necessary holes, openings etc. for laying/ Installation of HVAC equipments and shall make good as required. Nothing shall paid extra on this account.
ELECTRICAL WORK- DSR ITEMS
AIR COOLED VRV/VRF UNITS
OUTDOOR UNITS (HEAT PUMP TYPE)
DSR (2019) ITEM NO-1 - Supplying, installing, testing and commissioning of Modular type Variable Refrigerant Flow/ Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above14HP modules, microprocessor based Controller, topdischarge type condensing unit(s), withR 410A Refrigerant, vibration isolators, with suitable foundation etc. complete as required.The unit shall deliver the rated capacity at AHRI Conditions and work evenat 50°C ambient temperature without tripping.The unit shall be suitable to work on 400V+/-10%, 3Phase, 50Hz AC power supply.The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5.
INDOOR UNITS
DSR (2019) ITEM NO- 2 - Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF CassetteType Indoor ceiling mounted unit equipped with synthetic washable media pre-filter,fan section with low noise fan/dynamically balanced blower,multi speed motor,coil section with DX Copper coil,electronic expansion valve,outer cabinet, drain pump, grill, necessary supports,vibration isolation,cordless remote control etc., suitable for operationon single phase230V±10%,50Hz AC supply,complete,as required. The unit shall haveautomatic force shut down provision incase of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature
Ceiling Mounted Cassette Unit
DSR(2019) ITEM NO-2.5 - 2.0 TR
DSR(2019) ITEM NO- 2.6 - 2.4 TR
DSR(2019) ITEM NO- 2.7 - 2.8 TR
DSR(2019) ITEM NO- 2.8 - 3.2 TR
DSR(2019) ITEM NO- 2.10 - 4.0 TR
Wall Mounted
DSR(2019) ITEM NO- 3 - Supply,installation,testing and commissioning of following minimum capacity VRV/VRF Hi-wall Type Indoor unit equipped with synthetic washable media pre-filter,fan section with low noise fan/dynamically balanced blower,multi speed motor,coil section with DX Copper coil,electronic expansion valve,outer cabinet,drain pan,necessary supports,cordless remote control etc., suitable for operationon single phase230V±10%,50Hz AC supply,complete,as required. The unit shall haveautomatic force shut down provision incase of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature
DSR(2019) ITEM NO- 3.2 - 0.8 TR
DSR(2019) ITEM NO- 3.3 - 1.0 TR
DSR(2019) ITEM NO- 3.5 - 1.45 TR
DSR(2019) ITEM NO- 3.6 - 1.65 TR
DSR(2019) ITEM NO- 3.7 - 2.0 TR
DSR(2019) ITEM NO- 5 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquidlines,all accessories as per specifications etc. as required
DSR ITEM NO- 5.1 - 6.4 mm dia (OD) (Softdrawn) with tube thick ness 1.2 mm with 19mm thick insulation
DSR(2019) ITEM NO- 5.2 - 9.5 mm dia (OD) (Softdrawn) with tube thick ness 1.2 mm with 19mm thick insulation
DSR(2019) ITEM NO- 5.3 - 12.7 mm dia (OD) (Softdrawn) with tube thick ness 1.2 mm with 19mm thick insulation
DSR(2019) ITEM NO- 5.4 15.86 mm dia (OD) (Softdrawn) with tube thick ness 1.2 mm with 19mm thick insulation
DSR(2019) ITEM NO- 5.5 - 19.0 mm dia (OD) (Softdrawn) with tube thick ness 1.2 mm with 19mm thick insulation
DSR(2019) ITEM NO- 5.6 - 22.2 mm dia (OD) (Softdrawn) with tube thick ness 1.2 mm with 19mm thick insulation
DSR(2019) ITEM NO- 5.7 - 25.4 mm dia (OD) (Softdrawn) with tube thick ness 1.2 mm with 19mm thick insulation
DSR(2019) ITEM NO- 5.8 - 28.58 mm dia (OD) (Softdrawn) with tube thick ness 1.2 mm with 19mm thick insulation
DSR(2019) ITEM NO- 5.9 - 31.8 mm dia (OD) (Softdrawn) with tube thick ness 1.62 mm with 19mm thick insulation
DSR(2019) ITEM NO- 5.10 - 34.9 mm dia (OD) (Softdrawn) with tube thick ness 1.62 mm with 19mm thick insulation
DSR(2019) ITEM NO- 5.11 - 38.1 mm dia (OD) (Softdrawn) with tube thick ness 1.62 mm with 19mm thick insulation
DSR(2019) ITEM NO- 5.12 - 41.27 mm dia (OD) (Softdrawn) with tube thick ness 1.62 mm with 19mm thick insulation
DSR(2018) ITEM NO- 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
DSR(2018) ITEM NO- 1.14.2 - 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
DSR(2018) ITEM NO- 1.14.11 - 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
DSR(2018) ITEM NO- 1.32 - Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
DSR(2018) ITEM NO- 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
DSR(2018) ITEM NO- 2.4.3 - 8 way (4 + 24), Double door
DSR(2018) ITEM NO- 2.10 - Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
DSR ITEM NO- 2.10.1 - Single pole
DSR ITEM NO- 2.13 - Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
DSR(2018) ITEM NO- 2.13.2 - 63 A
DSR(2018) ITEM NO- 2.14 - Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
DSR(2018) ITEM NO- 2.14.3 - 63 A
DSR(2018) ITEM NO- 4.6 - Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
DSR(2018) ITEM NO- 4.6.1 - 100 mm. Width x 50mm. Depth x 1.6mm. Thickness.
DSR(2018) ITEM NO- 4.6.2 - 150 mm. Width x 50mm. Depth x 1.6mm. Thickness.
DSR(2018) ITEM NO- 4.6.3 - 225 mm. Width x 50mm. Depth x 1.6mm. Thickness.
DSR(2018) ITEM NO- 4.6.4 - 300 mm. Width x 50mm. Depth x 1.6mm. Thickness.
DSR(2018) ITEM NO- 5.16 - Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
DSR(2018) ITEM NO- 16.12.1 - Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
DSR(2018) ITEM NO- 16.12.1.2 - Thickness 0.80 mm sheet
DSR(2018) ITEM NO- 16.12.1.3 - Thickness 1.00 mm sheet
DSR(2018) ITEM NO- 16.12.2 Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
DSR(2018) ITEM NO- 16.12.2.1 - Thickness 0.63 mm sheet
DSR(2018) ITEM NO- 16.12.2.2 - Thickness 0.80 mm sheet
DSR(2018) ITEM NO- 16.15 - Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
DSR(2018) ITEM NO- 16.16 - Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
DSR(2018) ITEM NO- 16.19- Supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications.
DSR(2018) ITEM NO- 16.19.1 - 200 mm dia.
Non Schedule Rates Items
NS-1 Supply, installation, testing and commissioning of touch screen controller (Which is controlled 50 nos. indoor units in terms of ON/Off Status, temp. Status, Fan Speed, ODU On/Off Status etc.) with all accessories and controls.
NS-2 Supply, installation, tesing and commissioning of Imported fittings Y-joints insulated, distributer and headers for all Indoor units at both the ends floors layout as per layout drawings.
NS-3 Supply, installation, testing, termination and commissioning of control cum transimission wiring (should be shielded cable in PVC Pipe) of 2C x 1.5 Sqmm Cu between indoor unit and out door unit and indoor units and its remote controller in 20 mm PVC conduit.
NS-3(a) - 2C x 1.5 Sqmm Cu Cable
NS-4 Providing & fixing rigid PVC piping complete with fittings, supports as per specifications and pre insulated with 6mm thick closed cell elastomeric nitrile rubber tubular insulation.
NS-4 (a) - 25 mm dia
NS-4 (b) - 32 mm dia
NS-4 (c) - 40 mm dia
NS-4 (d) - 50 mm dia
NS-5 Supply,installation,testing and commissioning of Propeller fan of the following capacity of approved make and specification. Fan shall be supplied bird screen.
NS-5 (a) - 300 mm dia propeller fan, with single phase motor
NS-6 - Supply, installation, testing and commissioning of AMCA Certified circular type Inline fan of the following capacity of approved make and specification. (Cost to be inclusive of Speed Regulator) Fan shall be supplied with bird screen.
NS-6 (a) - 200 CFM, 7mm SP WG with Single phase motor with three speed
NS-7 - SITC of AMCA Certified (For Air and Sound Performance) tube axial flow fan of different capacity as mentioned below in standard M.S.contruction. Entire fan model & AMCA Seal shall apear in techncial submittal of fan. All the fans are synthetic enamelled panited/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet and fire retardent flexible connections at inlet/outlet. The electric motor coupler shall be squirrel cage induction motor (IE-3 type) confirming to IS - 325-IP - 55 with class `F' insulation. Fan efficiency should not be less than 70 %, noise level should not be more than 85 db @ 3 m distance when measured in hemisperical reverberant room conditions. Fans should be as per specification and drawings. (As per Vent. Fan Schedule ) (Makeup Air & Pressurization Fans with St. Press. of 40 mmWG/Make Up Air Fan at 30mm WG) Long case Tube axial flow fans, as per specifications and approved makes suitable for three phase operation at 960/1450 RPM respectively Normal/Smoke case.
NS-7 (a) - 8000 CFM for Liftwell & Lobby pressurization, 40 mm S.P.
NS-7 (b) - 15500 CFM for Liftlobby pressurization, 40 mm S.P.
NS-8 - Supply,installation testing and commissioning of AIR CURTAIN of following size as per approved make and with Door limit switch/sensor with multi speed regulator .(At ground entrance)
NS- 8 (a) - 2100 mm long (High flow type)
NS-9 Supply,application of under deck insulation of roof exposed to direct sun , with Thermal insulation material for Under-deck insulation shall be closed cell cross linked polyethylene foam. Thermal conductivity of the insulation material shall not exceed 0.032 W/moK at an average temperature of 25°C. Density of the material shall be 25-30 Kg/m3. The product shall have temperature range of –40 °C to 105°C. The insulation material shall be fire rated for Class 1 as per BS 476 Part 6: 1989 for fire propagation test and as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability as per DIN 52615 shall not exceed 0.15ng/Pa.Sec.m.
NS-9 (a) - 13 mm thick Under deck insulation as per the specifications detailed above in the section
AHU/Fan Panel
NS- 10 - Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of following LT panels fabricated out of 14 guage CRCA sheet steel in cubical formationwith reinforecment of suitable size angle iron and channel T iron flats. All steel material used in the construction of panels shall be powder coated. A solid busbar shall be provided at the bottom of the panel with two connecting eyes for termination. The boards shall be suitable for 415 volts, 50 Hz, 3 phase , 4 wire supply system. All the hardware used in the fabrication of the panel shall be galvanized with zinc passivation. The panel shall be compartmentalized to accommodate one feeder in each compartment. A vertcal cable alley of suitable width shall be provided to serve on or two vertical feeder sections. Also the opening between the busbar chamber and the feeder section shall be shrouded with bakelite / hylam sheet with min.3 mm thickness. The rates for the distribution boards from the Breakers and instruments shall also include the following : TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequate size of neutral link. All MCB’s shall be of minimum 10 KA breaking capacity and MCCB 's shall be not lessthan 25KA
The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermal magnetic microprocessor releases as per BOQ and following : i. MCCB rating upto 250 Amps with thermal magnetic releases. ii. MCCB above 250 Amps with microprocessor releases. All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic. Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993. i. IP 42 for indoor panels. ii. IP 55 for ODU panel. All MCCB’s shall be provided with operating mechanism for door interlock. All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire. Providing cable clamps / supports within distribution boards cable alley. Current density of aluminium shall be 1sq mm for 1.0 Amps for rated current of bus bars. Model, current capacity location and frame size of switchgear shall be written inside of the panel doors with paint / permanent marker as approved shop drawings / site requirment. All meter shall be digital type and all starter shall be as per Type-2 Coordination chart Current Transfomer shall be resin cast. All Panel Shall be BMS Compitable
The panel drawing shall be approved before taking up the fabrication and compitable BMS if in future required.
In All panel Each starter should have remote control and interlocking facilities including auto manual switch, NO/NC contacts for control and must have auto manual operation suitable to take signal from fire alarm panel for automatic operation of fan in case of fire. All smoke /vent. fan panel the starters shall have suitable facility to operate with fire sensing control modules.
NS- 10 (a) HVAC Pressurization Fan Panel MCC-1
Incoming
1 no. 80 amp MCCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
100 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
2 no. 6-10 A, TP MPCB (with DOL starter )
1 no. 13-18 A, TP MPCB (with DOL starter )
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings.
NS- 10 (b) HVAC Pressurization Fan Panel MCC-2
Incoming
1 no. 50 amp MCB
Phase indicating lights with control fuses.
Breaker ON/OFF/TRIP indicating lights.
Bus Bars
80 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves.
Outgoings
2 no. 6-10 A, TP MPCB (with DOL starter )
The base frame shall be 75 mm x 5 mm.
Panel as described above and in drawings.
NS-11 Supply, installation, testing & commisioning of Aluminum conductor cables PVC sheathed/XLPE Insulation, armoured cables of 1.1 KV grade with identification tags, clamps and saddles etc.
NS-11 (a) - 3Cx4 Sqmm
NS-11 (b) - 3Cx6 Sqmm
NS-11 (c ) - 4Cx6 Sqmm Cu
NS-12 Supply, installation, testing & commisioning of Copper conductor , PVC insulated, PVC sheathed /XLPE cable of 1.1 KV grade (Which is Interconnecting wiring for the fire alarm system with the HVAC Panel & Touch screen controller ).
NS -12 (a) - 8C x 1.5 Sqmm
NS-13 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
NS -13 (a) 3Cx04 Sqmm
NS -13 (b) 3Cx06 Sqmm
NS -13 (c) 4Cx06 Sqmm
Aircon Technique Private Limited
TRANSCEND CONTRACTS PVT LTD
APEXINFRANET PVT LTD
Competent Engineers
AB3S SOLUTIONS PVT LTD
Aircon Technique Private Limited
TRANSCEND CONTRACTS PVT LTD
APEXINFRANET PVT LTD
Competent Engineers
AB3S SOLUTIONS PVT LTD
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .