The Additional Chief Engineer/ Tirupur EDC
OFFICE OF THE ADDITIONAL CHIEF ENGINEER, TIRUPUR ELECTRICITY DISTRIBUTIONCIRCLE/ CIVIL SECTION, 208/650, KRBS TOWERS, 3RD FLOOR, PERUMANALLUR ROAD, TIRUPUR
Civil works Extension of the existing control room of the Andipalayam33/11 KV Sub Station of Tirupur Division
2022_EB_248691_1
Civil Spec.No.08/2022-23 Dt.18.08.2022
Open Tender
Civil Works - Buildings
Works
120 days
Tirupur
2 documents required · 2 mandatory
₹0
₹13,160
Yes
15 Sept 2022
25 Aug 2022
10 Sept 2022
25 Aug 2022
9 Sept 2022
25 Aug 2022
25 Aug 2022 - 9 Sept 2022
Dismantling of Brick / Stone Masontry in Cement Morter Walls and Clearing away and carefully stacking materials for re-use for any thickness of walls including cost of T&Ps, Labour, lead, lift etc., complete.
Dismantling of PCC and Clearing away including cost of T&Ps, Labour, lead, lift etc., complete.
Dismantling of RCC and Clearing away including cost of T&Ps, Labour, lead, lift etc., complete.
Dismantling of Floor finish and dadooning walls in Cement Morter with Mosaic Tiles / Glazed Tiles / Cuddappah Slabs and Clearing away including cost of T&Ps, Labour, lead, lift etc., complete.
Supplying and Fabrication of ISMB of required size for supporting the RCC Roof slab including cutting, fixing in position, centering, cost of material, Labour lead, lift, etc., complete, as per standard specification ,.
Earth work excavation and depositing on bank with initial lead of 10m and initial lift of 2m in hard stiff clay, stiff black cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders including labour, lead, lift etc., complete as per standarded specification.
Earth work excavation and depositing on bank with initial lead of 10m and Initial lift of 2m in Soft Disintegrated rock, laterite, soft rock or kankar, not requireing blastng including labour, lead, lift etc., complete as per standarded specification.
Earth work excavation and depositing on bank with initial lead of 10m and initial lift of 2m in medium rock and dense medium rock not requiring blasting including labour, lead, lift etc., complete as per standarded specification.
Providing Anti termite treatment in 4 stages I) immediate after earth work excavation and before laying foundation concrete II) after refilling for sides of foundation III) Before laying of flooring concrete IV) outside of basement upto 1.0m alround the building using termite 250ml for 5lit of water including cost of all materials, labour, lead, lift etc., complete as per standarded specification etc., complete.
Supplying and filling with M.Sand for foundation including cost of all materials, well consolidation, labour, lead, lift, etc. complete.
PCC 1:3:6, using 20mm HBG metal foundation and flooring including cost of cement, all materials, labour, lead, lift, etc. complete.
RCC 1:1.5:3 using 12-20mm graded hard machine broken granite stone for Raft concrete including cost of all materials, centering, curing, labour, lead, lift, etc. complete. But excluding cost of steel reinforcement.
RCC 1:1.5:3 using 12-20mm graded hard machine broken granite stone for column concrete upto basement including cost of all materials, centering, curing, labour, lead, lift, etc. complete. But excluding cost of steel reinforcement.
RCC 1:1.5:3 using 12-20mm graded hard machine broken granite stone for column concrete in ground floor including cost of all materials, centering, curing, labour, lead, lift, etc. complete. But excluding cost of steel reinforcement.
RCC 1:1.5:3 using 12-20mm graded hard machine broken granite stone for Grade beam concrete including cost of all materials, centering, curing, labour, lead, lift, etc. complete. But excluding cost of steel reinforcement.
RCC 1:1.5:3 using 12-20mm graded hard machine broken granite stone for Lintel concrete including cost of all materials, centering, curing, labour, lead, lift, etc. complete. But excluding cost of steel reinforcement.
RCC 1:1.5:3 using 12-20mm graded hard machine broken granite stone for Sunshade of 60cm width including cost of all materials, centering, curing, labour, lead, lift, etc. complete. But excluding cost of steel reinforcement.
RCC 1:1.5:3 using 12-20mm graded hard machine broken granite stone for Roof beam concrete including cost of all materials, centering, curing, labour, lead, lift, etc. complete. But excluding cost of steel reinforcement.
RCC 1:1.5:3 using 12-20mm graded hard machine broken granite stone for Roof Slab concrete of 125mm Tk including cost of all materials, centering, curing, labour, lead, lift, etc. complete. But excluding cost of steel reinforcement.
Brick work in CM 1:5 using II class champer burnt bricks for Walls, including cost of all materials, curing, labour, lead, lift, etc. complete.
Brick work in CM 1:3 using II class champer burnt bricks for partition wall, including cost of all materials, all labour charges, lead, lift, etc. complete.
Supplying and fixing of suitable GI angles horizontally @ 50cm c/c to the required length for supporting the cable in the cable duct in correct position including fabrication, labour for fixing in correct position, cutting etc., complete as per the drawing with standared specification.
Refilling with excavated earth other than sand in foundation and sides of masonry, consolidation as per std.specn.with water including all, labour, lead , lift, etc., complete.
Providing steel reinforcement with MS/RTS rods of reputed approved make for reinforced concrete works, including cost of steel MS/RTS rods, binding wire, monor T&Ps, labour charges for cutting, straightning, bending as per type design drawing, placing, aligning and tying properly with all leads and lift etc., complete as per standared specification.
Plastering with CM 1:5, 12mm thick including cost of all materials, labour, lead, lift, etc. complete.
Plastering with CM 1:3, 12mm thick for ceiling, Basements, beams, sunshade including cost of cement, all materials, curing, labour, lead and lift etc., complete.
Providing weathering course with PCC 1:2:4 mix using 6mm and 10mm HBG metal of a average thickness of 50 mm with water proofing compound and finishing the top with power trolling including cost of all materials, labour, curing, finishing with proper slope, lead, lift etc., complete as per the direction of site incharge.
Providing 110mm dia PVC down fall pipe of 4 Kg / sqcm, including cost of pipe, door bend, shoe and clamp, labour for fixing in position from the roof top, lead, lift etc., complete.
White washing two coats with white cement over a primary coat for ceiling, exposed surfaces of wall etc, including cost of all materials, lead, lift, etc., complete.
Colour washing two coats with oil bound distembering of approved quality and colour over a primeing coat using white cement for inside wall surfaces including cost of all materials, labour, lead, lift, T&P etc., complete.
Supplying and filling of gravel for basement filling with well consolidation, watering including cost of all materials, labour, lead lift etc., complete as per the direction of site engineer.
Supplying and laying of Acid proof tiles for Battery Room of approved quality and colour laid in CM 1:3, 20mm thick and pointing with white cement using 0.40 Kg/m2 including finishing joint and pointing flush with tiled surface including cost of cement, all materials, labour, curing, lead, lift etc., complete.
Supplying and laying of Vetrified floor tiles for size of 600 x 600 x 8 mm for control room etc., of approved Quality and colour laid in CM. 1:3 , 20 mm thick and pointing with white cement using 0.40 Kg/m2 including finishing joint and pointing flush with tiled surface including cost of cement, all materials,labour,curing, lead,lift, etc., complete.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The window should be got approved from the Executive Engineer before use on work cost of all materials , lead, lift , etc., complete, as per standard specification.
Providing UPVC Door and fixing casement doors fabricated from unplasticized polyvinyl chloride9UPVC) sections .The Profile should be three chamber system which provides high insulation properties with outer frame 60mmx55mm with an outer wall thickness of 2.4mm.The window unit should be designed with all corner joint mired and fusion welded.windows should be steel reinforced with 25x24x25mm steel reinforced with thickness of 1mm to have dimensional stability.The sash should be of 602x102mm. The mullion should be of 60x74mm.The profile should have coextruded seals with necessary harwares and the window system should be glazed with 5mm plain float glass/6mm bison lam including cost of all materials, lead, lift, etc complete as per standared specification.
Wiring with 2 x 1.5 sq.mm PVC unsheathed Multistrand Copper cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall and covering with 3mm thick hylum sheet with Steel switch box with continuous earthwire connection of 14 SWG TC wire and making good the damaged portion of masonary for PVC concealed light point / fan point (for electronic regulator).
Wiring with 2 x 1.50 Sq mm PVC unsheathed multistrand copper cables of 1100 V Grade in Suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall using suitable steel switch box with 3 mm tick hylum sheet covers for 5 A 3 pin non inter locking CS plug including pin top with continuous earth wire connection using 14 SWG TC wire and making good the damaged portion of masonry of PVC concealed plug point.
Wiring with 2 x 4 sq.mm (56/0.3) PVC insulated multistrand unsheathed copper conductor cable of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150 mm x 100 mm x 113 mm Steel switch box with 3 mm thick hylem sheet for 15 A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion, with suitable colour for concealed power plug point.
Supplying and fixing of 4' 20W LED 3000K flu.type fitting complete on wall/ceiling with tubes and PVC unsheathed Copper leads from terminal to the fitting including cost of all materials ,labour, lead, lift, etc.,complete
Supplying and fixing of 25 W LED Street Light Out Door Fitting with LED [Light Emitting Diode] with PVC unsheathed copper leads from the terminals to the fittings including cost of all materials ,labour, lead, lift, etc.,complete .
Supplying and fixing of 4'18 W LED bulb with twin type mirror optic suspension type fitting (Philips/ Crompton/ Wipro) complete with louvers cover complete with copper chokes and condensor with conduit pipe suspension, with PVC unsheathed copper leads from the terminals to the fittings with flu. tubes including cost of all materials, labour, lead, lift etc., complete,as per standard specification.
Supplying and fixing of 1400mm (56") AC ceiling fan complete with stepped electronic 300w regulator with 1.0m down rod including fan clamp with side plates and cross arm of size 450mm including cost of all materials, labour, lead, lift, etc., complete,as per standard specification.
Supplying and fixing of RCCB safe trip of appd LEGRAND , ISI make , 25amps with suitable box including cost of all materials labour, lead, lift, etc., complete as per standard specification.
Supplying and fixing of horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure double door of double door type with metal door with IP43 protection with 40A 4 pole MCB isolater as incoming and 12 Nos. 6A to 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark.
Earthing as per PWD standard with an earth electrode of 2 Mtr. Class 'B' GI pipe of dia not less than 32 mm complete with necessary masonry work.
Painting 2 coats of Acid Proof Paint for battery room over 1 coat of primer including cost of all materials, labour, lead, lift etc., complete.
Supplying and fixing of 450 mm (18") sweep heavy duty AC Exhaust fan complete with necessary wall opening and making good of the wall including cost of all materials, labour, lead, lift etc., complete as per standard specifications.
SUB TOTAL (Items 1 to 47)
EPF @ 13.00 % on 40 % of (Items 1 to 47)
ESI @ 3.25 % on 40 % of (Items 1 to 47)
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .