Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC NOT FOUND | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.7 L+₹3.3 L (19.7%)Rejected-Finance FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L2 | Rejected-Finance Other than L1 |
Tender Value
₹19.9 L
EMD Value
₹39,880
Closing Date
5 Sept 2024, 6:00 pmClosed
GE (AF) SIRSA
GE (AF) SIRSA, HARYANA-125055
AMC FOR FIRE DETECTION AND FIRE ALARM SYSTEM, AMC FOR PASSENGER LIFTS AT SMC BUILDING AND NEW ATC INCLUDING REPAIR/MAINTENANCE OF FIREFIGHTING AND FIRE ALARM SYSTEM AT AF STN SIRSA
2024_MES_665451_1
GE/SRA/T-47/2024-25
Open Tender
Miscellaneous Works
Item Rate
365 days
GE (AF) SIRSA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) SIRSA
₹39,880
Yes
18 Oct 2024
11 Jul 2024
6 Sept 2024
11 Jul 2024
5 Sept 2024
20 Jul 2024
Amount
Annual Maintenance Contract for Fire Alarm & Fire Detection System at WSA Including dismantling & refixing of unserviceable items complete all as specified and as directed comprising of the following :- Fire Detection & Alarm System :- (a) Fire Alarm Control Panel Four loop - 01 No. (b) Fire Alarm Control Panel Two loop - 05 Nos. (c) Smoke Detectors - 58 Nos. (d) Heat Detectors - 58 No. (e) Manual Call Point - 14 No. (f) Control Module - 59 No. (g) Fault/ Short Circuit Isolator - 05 No. (h) Remote Response Indicator - 116 No. (j) PVC Conduit Pipe 25mm - 850 RM (k) Copper Flexible Wire - 1660 RM
Annual Maintenance Contract for Fire Alarm & Fire Detection System at ATC Including dismantling & refixing of unserviceable items complete all as specified and as directed comprising of the following :- (a) Fire Alarm Control Panel Four loop - 01 No. (b) Fire Alarm Control Panel Two loop - 05 No. (c) Smoke Detectors - 58 No. (d) Heat Detectors - 58 No. (e) Manual Call Point - 14 No. (f) Control Module - 59 No. (g) Fault/ Short Circuit Isolator - 05 No. (h) Remote Response Indicator - 116 No (j) PVC Conduit Pipe 25mm - 850 RM (k) Copper Flexible wire - 1660 RM
Annual Maintenance Contract for Fire Alarm & Fire Detection System at SRE building Including dismantling & refixing of unserviceable items complete all as specified and as directed comprising of the following :- (a) Fire Alarm Control Panel Four loop - 01 No. (b) Fire Alarm Control Panel Two loop - 03 No. (c) Multi sensor detector Smoke & Heat with base - 27 No. (d) Fire alarm sounder/siren electronic type 65 DB to 120 DB -2 No (e) Manual Call Point - 06 No. (f) Addressable Control Module - 06 No. (g) Fault/ Short Circuit Isolator - 04 No. (h) Remote Response Indicator - 27 No (j) PVC Conduit Pipe 25mm - 416 RM (k) Copper HFFR PVC cooper conductor cable - 1940 RM
Annual Maintenance Contract for Auditorium Including dismantling & refixing of unserviceable items complete all as specified and as directed comprising of the following :- (a) Fire Alarm Control Panel Four loop (Notifier) - 01 N (b) Network repeater panel - 01 No. (c) Analogue addressable multi sensor detector - 210. (d) Addressable heat detector -04 (e) Analogue addressable control module -12 No (f) Fault isolator module - 10 No. (g) Remote response indicator -04 (h) Addressable zone interface module -04 (j) Hooter / strobe rated 100 db- 12 No . (k) Manual call point- 12 (l) PVC Conduit Pipe 25mm - 380 RM (m) Copper HFFR PVC cooper conductor cable 1.5sqmm- 1050 RM
Annual Maintenance Contract for Fire Alarm & Fire Detection System at Tech Flt Hangar & Sqn Hangar Including dismantling & refixing of unserviceable items complete all as specified and as directed comprising of the following :- (a) Fire Alarm Control Panel Four loop (Make: Notifier) - 02 No (b) Network repeater panel 4 inch 640 character - 04 No. (c) Analogue addressable multi sensor detector with hard addressing feature - 766 (d) Addressable fixed temperature 57 degree thermistor type heat detector - 06 No. (e) Analogue addressable mini monitor module -32 No (f) Fault isolator module - 48 No. (g) Analogue Addressable with hand addressing - 55 No. (h) Analogue addressable monitor module - 20 No. (j) Analogue addressable control relay module - 20 No. (k) Hooter / strobe rated 82 Db- 59 No. (l) Dual action addressable manual pull station with address switch - 59 No. (m) Response indicator for detector - 252 No (n) Intelligent electronically addressable duct detector (high velocity- 10Nos (o) Wall / ceiling mounted type Fire/flame detector - -16 Nos (p) PVC Conduit Pipe 25mm - 7260 RM (q) Copper HFFR PVC cooper conductor cable 1.5sqmm- 7000 RM
Re-commissioning, Fault inspection & fault rectification in Notifier Make Fire alarm system at Tech Flt Hangar and Sqn Hangar including repair / replacement of faulty wiring, conduit, flame /beam detector, addressable cards, panel wiring, MCP, strobe /sounder, modules any type and necessary works for panels recovery in healthy condition to come in operational condition without faults panels and all circuits with all accessory complete all as specified and directed. (NOTE: Rectification of Fire Alarm System for both Tech Flt Hangar & Sqn Hangar shall be considered as one job.
GENERAL NOTES TO ITEM NO. 01 TO 06 :- (A) Scope of work comprises of the following :- (i) Checking & Repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of Fire detection system in presence of rep of users and Engr-in-Charge. (iii) The Contractor will submit test report regarding functioning of all the equipments duly signed by contractor, user's rep and Engr-in-charge. (iv) Maintenance shall be carried out through the OEM or his authorised technician. Supporting documents in this regard shall be submitted for approval of Accepting Officer prior to commencement of work. (v) Emergency visit will be carried out when called for in addition to the breakdown call in case of any failure in the system, without any extra cost. (vi) Materials required for replacement will be measured and paid seperately under respective items of this schedule. (vii) Replacement of cards, any type, if required shall deemed to be included in the quoted rates for AMC. (viii) Contractor is responsible for arrangement & providing all T&P, ladder etc required for inspection & repair /replacement accessories)
Annual Maintenance Contract for Lift of 08 Passengers /544 Kg ( Manufacturing No: 10943048/Schindler) at ATC inside Technical area as per Terms and Conditions given as follows :- (a) Servicing of Lift at Regular Intervals and as Frequently as the Company deems necessary based on the Age, Nature and Condition of the Elevator and take all Reasonable Care and Maintaining of Lift Equipment in Safe and Proper Working Condition. (b) Carry out the Servicing Work as required whenever possible on a Day including Sundays & Holidays and during Regular Working Hours. (c) Replenish the Gear and Motor bearing with necessary Manufacturer recommended Lubricants whenever necessary and All Parts of the Lift will be checked, cleaned and lubricated to keep them, both Mechanically and Electrically in Perfect Working Condition. Replacement of Unserviceable Parts will be included in Quoted Unit Rate. (d) Carry out according to its Standards Customary Annual Safety Test to Examine All Safety Devices. (e) Lift AMC will be as per Terms and Conditions of OEM Company. (f) Contractor has to submit AMC within 20 Days after Acceptance of Tender. If the Contractor fails then necessary Recovery will be made as per Terms and Conditions of the Contract. NOTE : Contractor is responsible for Working and Inspection of Registration for the Year 2024-25 of Lift by Lift Inspector Cum Executive Engineer, Electrical Inspectorate, Haryana - Hisar is included in Quoted Unit Rate.
All as per srl item no 07 but for Lift of 06 Passengers / 408 Kg (Manufacturing No: L-13830/ Johnson ) at SMC .
All as per srl item no 07 but for Lift of 06 Passengers / 408 Kg (Manufacturing No: 43893240/ KONE) at Sqn Hangar inside Technical Area.
Supply only Battery 12V, 7.2 AH dry type of approved make, suitable for lifts complete all as specified and directed.
S&F in repairs Sprinkler (Quick Response), glass tube type, made of bronze, UL listed complete all as specified and directed by Engineer-in-charge.
S&F in repairs Sprinkler (Quick response), glass tube upright type, made of bronze, UL listed complete all as specified and directed by Engineer-in-charge.
S&F in repair incl testing & commissioning of addressable type Fire Alarm Control Panel complying with BS EN 54, 2 loop panel with 99 detectors and 99 modules & up to 200 detectors and modules (per each loop) along with all accessories, loop cards, power supply card, alarm ask/reset card etc including taking down existing panel complete all as specified and directed by Engineer-in-charge. (MAKE: HONEYWELL, MODEL NO: DXc2 or equivalent model in other makes specified in tender)
S&F in repair incl testing & commissioning of addressable type Fire Alarm Control Panel complying with BS EN 54, 4 loop panel with 99 detectors and 99 modules & up to 200 detectors and modules (per each loop) along with all accessories, loop cards, power supply card, alarm ask/reset card etc including taking down existing panel complete all as specified and directed by Engineer-in-charge. (MAKE: HONEYWELL, MODEL NO: DXc4 or equivalent model in other makes specified in tender)
Supply, installation, testing & commissioning of addressable Manual Call Point, resettable type including necessary back box / junction box for mounting Lever Pull Type including taking down existing call point complete all as specified and directed. (MAKE: HONEYWELL, MODEL NO: HM/MCP/GLASS or equivalent model in other makes specified in tender)
Supply, installation, testing & commissioning of addressable Control module, capable of providing DPDT contact rated at 24V DC, 2A. (For hooter/strobe) including taking down existing control module complete all as specified and directed. (MAKE: HONEYWELL, MODEL NO: MI/DCMO or equivalent model in other makes specified in tender)
Supply, instalation, testing & commissioning of addressable Fault isolator module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected including taking down existing isolator module complete all as specified and directed. (MAKE: HONEYWELL, MODEL NO: MI/DISO or equivalent model in other makes specified in tender)
S&F in repairs remote Response indicator for above ceiling detector complete all as specified and directed. (MAKE: HONEYWELL, MODEL NO: RI/007H or equivalent model in other makes specified in tender)
Supply, installation, testing & commissioning of LOOP SOUNDER Hooter cum strobe dual tone type with suitable M.S.CRCA housing and wiring circuit, with powder coated finish of approved colour including taking down existing hooter complete all as specified and directed. (MAKE: HONEYWELL, MODEL NO: WSO-PR-N05 + MI/B501AP/IV or equivalent model in other makes specified in tender)
Supply, fixing & testing PVC insulated FRLS single core multi stranded copper conductor cable 1.5 sqmm, 1.1KV including taking down existing wiring complete all as specified and directed.
S&F in repairs fire hydrant landing valve type A single head outlet of 63 mm dia, conforming to IS:5920 complete all as specified and directed by Engineer-in-charge.
S&F in repairs Hose Box made of 18 gauge MS steel of min size 800m x 600 mm x 250mm with double door & 4 mm thick glass and door frame made of 16 gauge MS sheet, painted fire red outside and brilliant white inside box suitable to house 02 Nos hose reel drum 02 Nos Gun metal nozzle complete all as specified and directed by Engineer-in-charge.
S&F in repairs 63 mm dia gun metal branch pipe, instantenous inlet, male threaded outlet, 15 mm bore nozzle long suitable for fire hydrant, complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs Hose reel Drum suitable for hose pipe of size 63 mm complete all as specified and directed by Engineer-in-charge. (NOTE: Hose shall be measured and paid seperately)
S&F in repairs 63 mm bore, 15 metre long fire hose, RRL (Reinforced Rubberised Lined), type "1" marked (Conforming to IS-636) with aluminium metal coupling, complete all as specified and as directed.
S&F in repairs Fire hydrant stand post 80mm dia GI/MS flanged type 1.5 m height single outlet confirming to IS 908 complete all as specified and directed by Engineer-in-charge.
S&F in repair Cast Iron Sluice valve, 80mm bore, Class PN-1.6 long body type, heavy duty, ISI marked (IS 1538) flanged end with iron wheel and brass spindle including 3 mm thick rubber gasket joints, nuts, bolts etc complete all as specified and directed.
S&F in repair Cast Iron non-return valve, 80mm bore, Class PN 1.6, heavy duty, ISI marked (IS 5312), flanged end including 3 mm thick rubber gasket joints, nuts, bolts etc complete all as specified and directed.
S&F in repairs 100 mm bore CI Foot valve with gun metal working parts , heavy duty, ISI marked (IS 4038), flanged end including rubber gasket joints, nuts, bolts etc including testing complete all as specified and directed.
S&F in repair gun metal branch pipe with nozzle of 20 mm dia for hose reel conforming to IS 8090 complete all as specified and directed.
S&F in repairs thermoplastic hose reel of 20 mm dia and 30 meter length conforming to IS-5132 complete all as specified and directed.
Maintenance and complete servicing of Kirloskar Make Diesel Engine type 4R1040T of capacity 83 HP coupled with fire pump of capacity (Discharge capacity 2280 LPM at 70 metre head) 75 HP consisting of normal repairs if required including replacement of defective/worn out parts such as filters, gaskets, V belts, Engine oil, coolant, rubber hoses, worm drive clamps, nuts & bolts, cleaning of alternator with vacuum cleaner, replacement of battery terminals including greasing of bearings etc and testing and commissioning complete after necessary repairs all as specified and directed. NOTE:- (1) The work shall be carried out through an OEM authorised technician. Contractor's quoted rate shall be deemed to included for the same. (2) Replacement of unserviceable parts shall be measured and paid separately as "Supply Only" under respective items of BOQ. Contractor's quoted rate shall be deemed to be inclusive of the cost of all consumables and petty spares other than throse listed here-in-under.
Supply only Rubber coupling TC 16 complete all as specified and directed.
Supply only rubber hose pipe set with clamps suitable complete all as specified and directed.
Supply only Oil filter element with O ring suitable complete all as specified and directed.
Supply only Fuel filter element with O ring suitable complete all as specified and directed.
Supply only air filter element complete with outer and inner suitable complete all as specified and directed.
Supply only Engine Oil 15W-40 in 10 Litres pack complete all as specified and directed.
Supply only Coolant suitable for Diesel Engine in sealed containers complete all as specified and directed.
Overhauling of 12 Volts capacity self starter including repair/replacement of carbon brushes, bearings, bushes, rewinding of armature with super enamelled winding wire and field, varnishing complete all as specified and directed.
Dismantling the Fire Fighting Centrifugal Pumpset type DSM 100/36 discharge capacity 2280 LPM at 70 metre head, 75 HP (Make Kirloskar), transportation to workshop for carrying out repairs, replacement of unserviceable parts, re-assembling, transporting back, fixing the pump in position and testing and commissioning complete to the entire satisfaction of Engr-in- Charge. NOTE:- (1) Transportation of pump from site to workshop for repairs and back to site shall be carried out be contractor under his own arrangement. Contractor's quoted rate shall be deemed to included for the same. (2) Replacement of unserviceable parts shall be measured and paid separately as "Supply Only" under respective items of BOQ. Contractor's quoted rate shall be deemed to be inclusive of the cost of all consumables and petty spares other than throse listed here-in-under.
Supply only CI impeller suitable for pump type DSM 100/36 complete all as specified and directed.
Supply only gun metal bush suitable for pump type DSM 100/36 complete all as specified and directed.
Supply only MS Keys suitable for pump type DSM 100/36 complete all as specified and directed.
Replacement of Ball bearing suitable for pump type DSM 100/36 complete all as specified and directed.
Replacement of Roller bearing suitable for pump type DSM 100/36 complete all as specified and directed.
Dismantling the Fire Fighting Centrifugal Pump set type DB 80/26, discharge capacity 2280 LPM at 70 metre head, 75 HP (Make Kirloskar), transportation to workshop for carrying out repairs, replacement of unserviceable parts, re-assembling, transporting back, fixing the pump in position and testing and commissioning complete to the entire satisfaction of Engr-in- Charge. NOTE:- (1) Transportation of pump from site to workshop for repairs and back to site shall be carried out be contractor under his own arrangement. Contractor's quoted rate shall be deemed to included for the same. (2) Replacement of unserviceable parts shall be measured and paid separately as "Supply Only" under respective items of BOQ. Contractor's quoted rate shall be deemed to be inclusive of the cost of all consumables and petty spares other than throse listed here-in-under.
Supply only CI impeller suitable for pump type BD 80/26 complete all as specified and directed.
Supply only gun metal bush suitable for pump type BD 80/26 complete all as specified and directed.
Supply only MS Keys suitable for pump type BD 80/26 complete all as specified and directed.
Replacement of Ball bearing suitable for pump type BD 80/26 complete all as specified and directed.
Replacement of roller bearing suitable for pump type BD 80/26 complete all as specified and directed.
Dismantling the Fire Fighting Jockey Pump set 10 HP to 12.5 HP (Make Kirloskar), transportation to workshop for carrying out repairs, replacement of unserviceable parts, re-assembling, transporting back, fixing the pump in position incl testing and commissioning complete to the entire satisfaction of Engr-in- Charge. NOTE:- (1) Transportation of pump from site to workshop for repairs and back to site shall be carried out be contractor under his own arrangement. Contractor's quoted rate shall be deemed to included for the same. (2) Replacement of unserviceable parts shall be measured and paid separately as "Supply Only" under respective items of BOQ. Contractor's quoted rate shall be deemed to be inclusive of the cost of all consumables and petty spares other than throse listed here-in-under.
Supply only CI impeller suitable for jockey pump complete all as specified and directed.
Supply only gun metal bush suitable for jockey pump complete all as specified and directed.
Supply only MS Keys suitable for jockey pump complete all as specified and directed.
Supply only Ball bearing suitable for jockey pump complete all as specified and directed.
Supply only Roller bearing suitable for jockey pump complete all as specified and directed.
S&F in repairs pressure switch incl testing complete all as specified and directed. (MAKE: DANFOSS, KP-35 or equivalent item in other makes specified in tender)
S&F in repairs pressure switch incl testing complete all as specified and directed. (MAKE: DANFOSS, KP-36 or equivalent item in other makes specified in tender)
S&F in repairs HDPE hose pipe, 20mm bore, green colour in length as required on site complete all as specified and directed.
S&F in repairs Battery 12V 180 AH lead acid type Heavy duty with 36 months warranty complete all as specified and directed.
S&F in repairs Battery 12V, 7.2 AH dry type of approved make complete all as specified and directed.
S&F in repairs Pressure gauge 4"dial 0-21 kgs rating complete all as specified and directed.
S&F in repairs Pressure gauge 8"dial 0-21 kgs rating complete all as specified and directed.
Taking down the Electric/induction motor 70 HP of the any Make/Model from existing position, Shifting to workshop for the repair work, removing the burnt winding, cleaning rotor, stator, re-winding the motor with super enamelled copper wire of size equivalent to the original winding including insulated packing materials, Varnishing, Drying etc and installing back to the original position, testing and commissioning on full load for 8 hrs continuous running for the following capacities of motor all as specified & directed by Engr-in-Charge. NOTE:- (1) Transportation of motor from site to workshop for repairs and back to site shall be carried out be contractor under his own arrangement. Contractor's quoted rate shall be deemed to included for the same.
All as per item No. 67 but for 20 HP, 3 phase, AC, 415V
All as per item No. 67 but for 10 HP, 3 phase, AC, 415V
Ajay Enterprises (BID ID -3074433)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .