Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC | ₹23.4 L Quoted ₹24.5 L | L1 | Accepted-AOC Accepted due to lowest rate quoted |
| 2 | L2₹25.0 LRejected-Finance RZ 50D GALI NO 13 VASHISHT PARK PANKHA ROAD NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | ₹25.0 L | L2 | Rejected-Finance Rejected due to highest rate quoted |
| 3 | L3₹25.2 LRejected-Finance | ₹25.2 L | L3 | Rejected-Finance Rejected due to highest rate quoted |
| Sl No | Description | Qty | Unit | A B K Enterprises L1 | sheetal engineering L3 | M/S PARKASH ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation of soft/loose soil in trenches not exc 1.5 meter wide & not exc 1.5 mtr in depth: for foundationetc or for manholes, laying of pipe in any type of soil and getting out complete all as specified | 240 | Cum | 120 ₹28,800 | 90 ₹21,600 | 80 ₹19,200 |
| 2.00 | Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete. | 110 | CUM | 20 ₹2,200 | 90 ₹9,900 | 20 ₹2,200 |
| 3.00 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete. | 135 | CUM | 20 ₹2,700 | 90 ₹12,150 | 20 ₹2,700 |
| 4.00 | M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable all as specified and directed . | 110 | CUM | 220 ₹24,200 | 300 ₹33,000 | 225 ₹24,750 |
| 5.00 | M & L for Old size sub class ‘B’ bricks, laid in trenches as cable covers complete . | 13.66 | 1000 nos | 3,000 ₹40,980 | 5,000 ₹68,300 | 4,000 ₹54,640 |
| 6.00 | M & L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass complete. | 0.16 | CUM | 1,800 ₹291.60 | 1,999 ₹323.84 | 5,000 ₹810 |
| 7.00 | M & L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete. | 1.62 | CUM | 2,000 ₹3,240 | 1,900 ₹3,078 | 5,000 ₹8,100 |
| 8.00 | M & L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete. | 0.22 | CUM | 2,200 ₹495 | 1,900 ₹427.50 | 5,000 ₹1,125 |
| 9.00 | M & L for PVC insulated, stranded aluminium conductor served with inner sheathing PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm dia GI suspension wire , two single core cable of 10 Sqmm , complete all as specified and directed by Engr-In-Charge.Makes of cable : Finolex/Indo -Asian/Standard . | 160 | RM | 25 ₹4,000 | 55 ₹8,800 | 100 ₹16,000 |
| 10.00 | S & F in repair sub main wiring for circuit of size 6 sq mm 2 core (FRLS) alongwith earth wire of 6 sq mm single core of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor in existing PVC conduit complete all as specified and directed by Engr-in-Charge. | 200 | RM | 150 ₹30,000 | 99 ₹19,800 | 200 ₹40,000 |
Updated dates
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
2 Mar 2026, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
REPAIR /REPLACEMENT OF SERVO VOLATGE STABLIZER CHANGE OVER SWITCHES MCCBs AND DISTRIBUTION SYSTEM AND OTHER ALLIED WORK AT AF ARJANGARH UNDER GE (AF) GURGAON
2026_MES_750345_1
GE/GUR-/NIT-134/2025-26
Open Tender
Civil Works
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹80,000
12 May 2026
29 Jan 2026
4 Mar 2026
29 Jan 2026
2 Mar 2026
16 Feb 2026
Excavation of soft/loose soil in trenches not exc 1.5 meter wide & not exc 1.5 mtr in depth: for foundationetc or for manholes, laying of pipe in any type of soil and getting out complete all as specified
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable all as specified and directed .
M & L for Old size sub class ‘B’ bricks, laid in trenches as cable covers complete .
M & L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass complete.
M & L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete.
M & L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete.
M & L for PVC insulated, stranded aluminium conductor served with inner sheathing PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm dia GI suspension wire , two single core cable of 10 Sqmm , complete all as specified and directed by Engr-In-Charge.Makes of cable : Finolex/Indo -Asian/Standard .
S & F in repair sub main wiring for circuit of size 6 sq mm 2 core (FRLS) alongwith earth wire of 6 sq mm single core of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor in existing PVC conduit complete all as specified and directed by Engr-in-Charge.
Supply and fix on load "AUTOMATIC MOTORIZED CHANGE OVER SWITCH" of capacity 400 A, 4 Pole , 415 Volts, 50 Hz as per IEC-60947, complete with add on block bridge with function of auto and manual switch and with handle to operate manual including necessary connection with contactors and delay timer complete all as specified and directed, Cat No. CX4 C04-400, Make Shall be L& T or its equivalent
Maintenance / repairs to APFC panels, 3 phase AC 415 V, by skilled technician and replacement of unserviceable spares as specified below for capacities 40 to 200 KVAR including replacement of short circuited copper conductor cables with appropriate gauge PVC insulated stranded copper conductor cables and cleaning of all moving contacts of relay contactors, tightening of all terminals and testing afer repairs to ensure serviceability and corrected output at specified powerfactor all as specified and directed at site.
Supply and install capacitor metalized poly propylene ultra heavy duty (LTXL) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15%. Make Shall be : EPCOS/L&T/Havells/Siemens
(a)25 KVAr
(b)20 KVAr
(c)10 KVAr
(d) 5 KVAr
(e) 2KVAr
Cleaning and upkeeping the area including uprooting of shrubs/grass and removing creepers from fencing or poles / posts and brooming the complete area of sub station around panels,transformers, four pole structures etc upto 3 feet from fencing or pole externally , all around complete and maintaining the same during currency of contract period, removing the debris to a distance not exc 50m and depositing where directed complete all as specified & directed. Note : The payment will be made one time and nothing extra will be admissible to upkeep the area during currency of contract period. The cost of brooms, showels, pick axe etc shall be deemed to include in the rate quoted by tenderer.
Supply and fixing cable route indicator, made of MS sheet of size 200 mm x 150 mm x 3 mm thick, spot welded with angle iron of size 40 x 40 x 5 mm thick, 750 mm long embedded in PCC (1:2:4) type B-2( using 40mm graded crushed stone aggregate) block 30cm x 30cm x 40cm in ground including one coat of synthetic enamel black paint over one coat of red oxide zinc chrome primer and writing with white paint showing size of cable HT /LT complete all as specified & directed .
Supply & Fixing in repair including making connection testing and commissioning of new MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA. Note: The make of MCCB shall be L &T , GE , Havells, Strandard, crompton, C & S or any other make as per the make in the existing panel board or exactly suitable to the existing frame size. In case only one particular make is procuring by the bidder necceasry alteration required to fix the same at no extra cost shall be done by the bidder .
Ditto all as per iitem No. 16 but MCCB TP 400 Amps, 415 Volts, 36 KA, 50 Hz complete with extended terminals and PVC spreader complete all as specified and directed.
Ditto all as per iitem No. 16 but MCCB TP 630 Amps, 415 Volts, 50 KA, 50 Hz complete with extended terminals and PVC spreader complete all as specified and directed.
Ditto all as per iitem No. 16 but 4 Pole, 125 Amps, 415 V, 25 KA, 50 hz complete with extended terminals and PVC spreader complete all as specified and directed.
Ditto all as per iitem No. 16 but 4 Pole, 250 Amps, 415 V, 25 KA, 50 hz complete with extended terminals and PVC spreader complete all as specified and directed.
Ditto all as per iitem No. 16 but 4 Pole, 400 Amps, 415 V, 36 KA, 50 hz complete with extended terminals and PVC spreader complete all as specified and directed.
Ditto all as per iitem No. 16 but 4 Pole, 630 Amps, 415 V, 50 KA, 50 hz complete with extended terminals and PVC spreader complete all as specified and directed.
Ditto all as per iitem No. 16 but MCCB TP 125 Amps, 415 Volts, 16 KA, 50 Hz complete with extended terminals and PVC spreader complete all as specified and directed.
Dittoall as per iitem No. 16 but MCCB TP 250 Amps, 415 Volts, 36 KA, 50 Hz complete with extended terminals and PVC spreader complete all as specified and directed.
Trimming of tree branches upto 11m from ground level all along the over head electric supply lines, to clear all branches maintaining a clear distance of 1.5m from the conductors. The maximum average dia of branches shall not exceed 20cm. After trimming the cut pieces and branches are cleared from the road upto a distance 200m. Note: (a) Required tools, ladder, Safety equipment etc. shall be arranged by the firm. (b) Area wise shut down to feeders shall be given on one day notice upto 4hrs.
M & L for Earthing to OH/Sub stn with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead GI wire 4 mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 of MES Schedule pt-I 1991, GI earth lead wire protected by GI pipe 15mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete Note : Main earth lead beyond 7.5 meter shall measured and paid saperatly.
. ------ditto----- all as per above item no - 27 but main earth lead 32 x 6 mm galvanised iron strip.
M & L for Earthing to OH/Sub stn with earth plate electrode copper plate 60×60cm ×3.15mm burie d directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth strip 20×3mm copper strip as earthing lead by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 of MES Schedule pt-I 1991, GI earth lead wire protected by GI pipe 15mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete Note : Main earth lead beyond 7.5 meter shall measured and paid saperatly.
M & L in repair for Earth continuity conductor or main earthing lead of 32 x 6 mm galvanized iron strip, buried in ground or fixed to wall in repair complete.
M & L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw.
M&L for pole painting, concrete pole with 02 coat of wheather exposed dust proof "apex" emulsion, pole height should be 9/11 mtr. Painting should be done from top to bottom at ground level. Bottom portion of the pole upto 1.50 m from top of the copping with one coat of synthetic enamel paint with marking pole numbers & marking three blue & two white strips width 25 cm by fluorescent paint complete all all as specified and directed .
Supply and fill of back feel compound in earth pit complete all as specified and directed . Make - S N Engineering or Equivalent .
Supply , laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 10 Sqmm nominal cross section x 4 core.
All as per item no. 34 but Size 16 Sqmm X 4 core
All as per item no. 34 but Size 25 Sqmm X 4 core
All as per item no. 34 but Size 50 Sqmm X 3.5 core
All as per item no. 34 but Size 70 Sqmm X 3.5 core
All as per item no. 34 but Size 95 Sqmm X 3.5 core
All as per item no. 34 but Size 120 Sqmm X3.5 core
All as per item no. 34 but Size 240 Sqmm X3.5 core
All as per item no. 34 but Size 300 Sqmm X3.5 core
All as per item no. 34 but Size 400 Sqmm X3.5 core
Supply and fix ON load four pole changeover switch with front handle operated of 4 pole 415 volt 50 Hz 630 amps in open execution to be fixed in existing panel with suitable size nut/bolts and complete all as directed.
Supply and fix ON load four pole changeover switch with front handle operated of 4 pole 415 volt 50 Hz 400 amps in open execution to be fixed in existing panel with suitable size nut/bolts and complete all as directed.
Supply and fix ON load four pole changeover switch with front handle operated of 4 pole 415 volt 50 Hz 800 amps in open execution to be fixed in existing panel with suitable size nut/bolts and complete all as directed.
M & L for Painting of steel pole with cross arms, clamp of any length and shape for LT overhead line with single coat of aluminium paint including preparation of the existing surface including marking pole numbersand marking three blue & three white bends width 20 cm by fluorescent paint, from bottom of pole to 1.5 Mtr height complete all as specified and directed.
S&F Danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp for LT size 20 X 15 Cm fix in repairs complete all as specified.
M&L for searching fault location of HT/LT UG cable 11000/415 Volts laid in trenches/ducts with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with frequency distance calculator etc incl transportation of machinery. Excavation in normal soil strata exposing the cable fault removal of deteriorated portion of the cable treating of cable of any size including disconnecting and re-fixing cables with lugs as per direction of Engineer-in-charge.
S & F pole box for street light dust and vermin proof make : Sintex model GSJB 3020 or equivalent in Universal complete with aluminum bus bar 04 nos. of capacity 200 amps on epoxy insulators incl one MCB SP C series 06 amps 10 KA capacity-01 nos. for Security light connection including suitable size PVC glands-02 nos at bottom for cable entry and exit complete all as specified and as directed. Make Shall be : Sintex/Universal/National. Note : MS Clamps shall be measured and paid seperately under relevant items.
M & L for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground
M&L Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground.
Supply and fix epoxy insulators 25 mm dia base with suitable screws complete for fixing AL strip if size 25x3.15 mm
Supply and fix porcelain insulator (white colour) for running of GI/Aluminium/Copper strips of size 32/20/25 mm including suitable size of screws for fixing vertically/horizontal plane at any height and making suitable size holes on strips including nut/bolts/wahsers etc complete all as specified and directed.
M & L Air termination of Lighting conductors, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed .
M & L Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and directed .
Supply and fix in replacement double door TPN DBs 415V 4 way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral & DB's will be fitted concealed in wall / surface as per site required complete all as specified and directed .
S & F in replacement with MCB TPN 415V 32 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed .
S & F in replacement with MCB TPN 415V 40 to 100 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed .
S & F in replacement with Isolator Four pole / MCB TPN 100 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed.
Supply and fixing in repair LED street light fittings 90 watts 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including therma; management in multiple optics complete with IP 65/66 protection complete with provision of twin core teisted copper wire 23/0.0076 upto security light from pole loop box . Cat No. ENDURACITYLINERNEOSL90WLED757PASYBOTG Make : Havells or equivalent in Bajaj/Wipro/Crompton
Supply and fixing of GI tubing, light grade, 40 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 25 to 50 sq mm complete . Make- Recmay / Denson or equivalent .
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 70 to 150 sq mm complete .Make- Recmay / Denson or equivalent .
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 185 to 300 sq mm complete .Make- Recmay / Denson or equivalent .
Supply and fixing steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-31 (9 meter long) complete, Including disconnecting and taking out old damage PCC pole all as directed .
Supply and fixing prestressed concrete pole 9 meters long 102 mm x 152 mm at top and 102 mm x 289 mm at bottom of class 10 complete, Including disconnecting and taking out old damage PCC pole all as directed . Note for item no - 61 & 62 -Earth work and PCC shall be measured and paid separately as these respectively.
S & F in repair sub main wiring for circuit of size 4 sq mm 2 core (FRLS) alongwith earth wire of 2.5 sq mm single core of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor in existing PVC conduit complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair TPN DB's 8 way vertical type 415 V, double door suitable for housing of 125 Amps MCCB as main incoming.
All as per item No. 69 above but of 4 way and suitable for housing of 100 A/63 A MCCB as main incoming.
S & F MCCB 125 Amps capacity, 4 pole, 25 KA, fixed thermal and magnetic release complete with extended terminals to be fixed in 8 way TPN DB complete all as specified and directed.
All as per item No. 71 above but capacity 100 Amps, fixed thermal and magnetic release, 4 Pole, 25 KA suitable to be fixed in 4 way TPN DB complete all as specified and directed.
Suply and fixing 240 V, 10 KA, 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity SP 5-32 Amps in the MCB DB complete with connection testing and commissioning.
Supply , laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 10 Sqmm nominal cross section x 2 core.
Dehydration of existing servo voltage stabilizer of oil minimum three cycles to achieve dielectric strength up to 60 KV in 2.5 mm gap electrode including toping up of oil if required at site .
Note for item no - 75 (i) voltage stabilizer oil shall be carried out at site and contractor shall be taken the testing result before and after dehydration of oil and shown to the EIC at site and maintain necessary documents for record .
(ii) Dehydration Machine with all T&P & Transformer oil testing machine for dehydration of Transformer oil and necessary transportation for the machines is arrange by contractor .
(iii) Oil required for topping up voltage stabilizer will be measured & paid separatly
Supply and charging topping up of new low viscosity transformer oil from sealed drums confirming to IS 335-1993 Part-II after testing the correct dielectric strength up to 60 KV at 2mm gap duly de-hydrated complete all as specified and directed.
Suuply and fixing street light brackets made out of GI tubing light grade, 40 mm bore 1200 mm long bent to sahpe at 120 degree, fixed on pole by providing MS clamp made up to flat iron 50 x 6 mm including nuts and washer of suitable size, fixed in repairs complete.
S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 12 ways 240 V complete all as specified and as directed .
S&F in replacement of sheet metal enclosure double door suitable for SPN distribution boards when MCBs to be used having 200Amp rated bus bar 8 ways 240 V complete all as specified and as directed.
S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 4 ways 240 V complete all as specified and as directed .
S&F in replacement of single pole and neutral enclosure with 2 pin and earth plug and socket complete with one single pole MCB 20 amps complete all as specified and as directed.
S&F in replacement MCB SPN 5 to 32 Amps, 240 volts, curve 'C', breaking capacity 10 KA, all as specified.
S&F in replacement MCB SPN 40 to 63 Amps, 240 volts, curve 'C', breaking capacity 10 KA, all as specified.
S & F in replacement enviroment friendly recess/pendent mounting LED flat panel 2'x2' fabricated CRCA sheet steel housing cool white with high efficient LEDs & glare free opal diffuser (40 W) PF>0.95 driver life >25000 Hours, operating range 140v to 280 V including all accessaries all as specified and directed. Make : Wipro/Crompton/Bajaj
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp
Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp
Fabricate, Supply install test and commissioning in repair of Feeder pillar box (Out door type) of size 100 cm x 80 cm x 40 cm (H x W x D) suitable for 440 Volt, 3 phase & Neutral , 50Hz supply, floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 2.5 mm thick CRCA sheet with gland plates at bottom with suitable Brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including with suitable size aluminium bus bars 600 Amps 04 Nos in its full width (60 cm length) to be fixed on suitable size of insulators. The bus bar having 08 Nos of holes including provision of suitable size of nuts and bolts of all four bus bars, the feeder pillar box shall be floor mouted with provision of four nos of legs made out out 50 x 50 x 5 mm MS angle not less than 40 cm the panel shall be grouted under PCC 1:2:4 complete all as specified and directed.
M & L opening the bus bar and rear/front panel of LT Panel board (01 Nos incoming and upto 15 Nos outgoing), disconnecting the cables from the busbars, replacement of suitable size of aluminium lugs of various size (25 sq mm to 300 sq mm) through hydraulic crimping method, replacement of burnt out nuts/bolts, replacement of cable glands, replacement of internal wiring, replacement of partially burnt out bus bar (if required) taking down carefully the copper/aluminium bus bar as required at site, scrapping the bus bar by emery paper for removing the silt/carbon, replacement of PVC insulation tape (RYB) and assembling the bus bar, LT Panel board complete for testing all as specified and directed.
All as per item No. 81 above but of (01 Nos incoming and upto 8 Nos outgoing)
All as per item No. 81 above but of (01 Nos incoming and upto 06 Nos outgoing)
All as per item No. 81 above but of (01 Nos incoming and upto 04 Nos outgoing)
M & L for scrapping the old painted surfaces and spray painting of HT/LT panel board of size upto 6 m x 2.5m x 1 m with two coats of synthetic enamelled paint of approved colour complete with all fittings etc all as specified and directed by Engineer-in-charge. (Note rate quoted by the contractor deemed to be included the writing of outgoing and incoming feeder etc).
All as per item No. 85 above but of size 3 m x 2 m x 1 m
All as per item No. 85 above but of size 2 m x 2 m x 0.75 m
Fabricate, Supply install test and commissioning in repair of Feeder pillar box (Out door type) of size cm x 60 cm x 50 cm x 40 cm (H x W x D) suitable for 440 Volt, 3 phase & Neutral , 50Hz supply, floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 2.5 mm thick CRCA sheet with gland plates at bottom with suitable Brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including with suitable size aluminium bus bars 250 Amps 04 Nos in its full width (60 cm length) to be fixed on suitable size of insulators. The bus bar having 08 Nos of holes including provision of suitable size of nuts and bolts of all four bus bars, the feeder pillar box shall be floor mouted with provision of four nos of legs made out out 50 x 50 x 5 mm MS angle not less than 40 cm and provision of 01 No. MCCB 160 Amps, 4 Pole, 25 KA, Fixed thermal and magnetic relase type, the panel shall be grouted under PCC 1:2:4 complete all as specified and directed.
Dismantling Air Circuit Breaker 4pole/3pole, 630 to 2000 Amps 415 Volts, draw out/fixed type from location and repair /overhauling of spring drive mechanism, coil, auxiliary switch including setting of over load coil,no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspecting male and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective position and testing complete all as specified and directed by engineer in charge Note : Spare parts will be measured and paid separately.
Supply , fix ,test and commissionning in repair in existing panel APFC Relay, 12 Stages digital type suitable for 415V, 3phase, AC supply and all specified and directed. Make - L&T/ Syntron/Sycon
M&L for preparation of old painted surfaces steel by brushing/changing stain, greasy spots with thinner and apply two coats of spray painting with with super enameled smokes grey colour paint of approved by Dept. and writing the MES /SM No with white paint as directed to Servo Volage Stab. indoor/outdoor installed at various different locations complete all as specified and directed at site.
(a) 100 to 160 KVA
S&F in replacement of digital display unit (Auto control card) suitable for servo type voltage stabilizer with complete wiring suitable for 100 to 300 KVA stablizer complete all as speicified and directed.
Supply and fix in replacement of Dimmer coil (Variable transformer) suitable for servo voltage stabilizer with complete wiring suitable for 100 to 300 KVA complete all as specified and directed.
Supply and fix in replacement of motor gear assembly suitable for 100 to 300 KVA capaicty servo type voltage stablizer complete all as specified and directed.
Supply and fix in replacement of Dimmer gear assembly suitable for 100 to 300 KVA capacity servo type voltage stabilizer complete all as specified and directed.
S & F in replacement of Panel indication lamp for servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed.
S & F in replacement of Ampere meter of Range 0 to 500 Amps with suitable size of C.T. (Digital type) for servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed.
S & F in replacement of Servo motor 10 K.G. torque for servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed.
(a) 100 to 160 KVA
S & F in replacement of R.C. net work for 10 K.G. motor for servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed.
S & F in replacement of Carbon Brush for servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed.
S & F in replacement of finger holding carbon brush for servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed.
Disconnecting and taking down existing security light/flood light fitting of any make or any capacity for repairs or replacement of burnt/worn out accessories (surge protector, driver, cable etc) through ladder/motorised/amnual system from GI braket on pole of any size and refixing the same after cleaning, general overhauling, repairing and making serviceable and refixed the same after making serviceable and testing complete all as directed. Note :- The new consumable item will be measured and paid seperately as under below :-
Supply only driver of any make or any model on existing LED street light luminaires of wattage 45 to 120 watt for LED street light fitting to match with the existing make and model complete all as specified and directed,
Supply only driver of any make or any model on existing LED flood light luminaire of wattage 60 to 120 watt for LED street light fitting to match with the existing make and model complete all as specified and directed.
Supply only surge protector of any make or any model on existing LED street light luminaires of wattage 45 to 120 watt for LED street light fitting to match with existing make and model complete all as specified and directed.
Supply only LED panel of any make or any model on existing LED street light luminaires of wattage 45 to 120 watt for LED street light fitting to match with existing make and model complete all as specified and directed.
Supply and fixing in repair LED post top 40/45 watts complete with suitable size of GI pipe suitable size of required length duly grouted in existing locations including , PVC copper wire 1.5 sq mm 3 core of required lenght (upto 3 mtrs) complete all as specified and directed.
Supply and fixing in repair LED bollard fitting 10w complete with suitable size of nuts/bolts for fixing arrangement and provision of suitable size PCC foundation for fixing of bollard fitting etc complete all as specified and direction by Engr-in-charge.
M & L in repair for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed .Dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as directed.
Supplying and laying synthetic rubber insulated mats 2.5 mm thick for voltage upto 11 KV (size 2 x 1 m) for electrical purpose as per IS 15652-2006 (superseding IS 5424) suitable for electrical shock safety. Make Shall be : Duratruf or its equivalent.
Supply & Fix shock treatment chart standard size with diagrams and illustrations dully framed properly laminated including hooks for fixing/ fastening. The detail illustrations shall be in Hindi & English all as directed and as specified.
Supply install test and commissioning of astronomical time switch distribution box, with auto/ manual ON / OFF facilitiy for street lights , 40 Amps capacity , 3 pole, with IP protection IP54, locking facility, all internal wiring prewired with copper counductor cable factory made pole mounted type , out door mounting clamps, outer enclosure fabricated of MS sheet ,powder coated, earth terminal,suitable cable glands for all cable incoming & out going , complete all as specified & directed by Engr in charge MAKE - INDOASIAN, Cat part No TL065AS0 / equivalent in Wipro / L & T
Cutting existing road surfaces or hard standing 0.45 mtr depth and 0.3 mtr width (22 CM thick comprising bituminous topping) for laying of pipes/cables and making good to the disturbed surfaces to match with existing complete all as specified and directed. Note : PCC for make good shall be measured and paid seperately
M & L for GI tubing (light grade) with all necessary fitting laid in trenches/under road crossing, or fixed on poles/walls/under floor etc complete all as specified and as directed for the following sizes:-
a) 50 mm dia bore
b) 80 mm bore
Fabricate, Supply install test and commissioning of CPRI approved Outdoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 3.15 mm thick CRCA sheet and load bearing members such as door partitions etc of thickness not less than 2.0 mm thick , with gland plates at bottom with suitable Brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including LED RYB indicators -06 nos on incoming side and ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars to MCCB's with suitable size aluminium bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection,including terminal adapters, spreader links on incoming and out going sides of MCCB's complete all as specified and directed and comprising the following .
(a) Bus bar Aluminium - 500 A capacity- 04 Nos high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves.
(b) MCCB 160 Amps 4 pole 36 KA, with adjustable thermal magnetic range as out going- 01 No.(Main incomer)
(c) MCCB 63 Amps 4 pole 16 KA with adjustable thermal magnetic range as out going- 04 Nos.
(d) MCB TPN 63 Amps, 10 KA, 'C Series- 03 Nos
(e) MCB SPN 40 Amps, 10 KA, 'B' Series - 04 Nos
(f) Digital multifuctional meter (Make : L&T), 4410 Series, Cat No. WL441010OOOO- 01 Nos
(g) ON/OFF indication lamp with toggle switch and three Nos indication lamp (R,Y,B) - 7 Set of three
Supply and fixing 3 Phase + Neutral Industrial power socket, 415 Volts, 32 Amps complete with male and female socket complete all as specified and directed
Supply and fixing 'C' series miniature circuit breaker (MCB) of TPN 25 to 63 Amps poles and current carrying capacity in the MC DB complete with connection testing and commissioning :-
Supply , assembly and erection, welding including suitable size of nuts bolts of Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes of Fe 410-W (Gde-E-250) quality-A
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
TenderDocuments134.pdf
Tender Documents • 0.43 MB
BOQ_840389.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid