| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 LAccepted-Finance 2 89 BIJOYGARH JADAVPUR KOLKATA 700032 | KOLKATA | KOLKATA | WEST BENGAL | 700032 | ₹2.1 L | L1 | Accepted-Finance That the Bid is L1 |
| 2 | L2₹2.1 LRejected-Finance BIDHAN MARKET BARASAT KOL 700124 | BARASAT | NORTH 24 PARGANAS | WEST BENGAL | 700124 | ₹2.1 L | L2 | Rejected-Finance That the Bid is not L1 |
| 3 | L3₹2.2 LRejected-Finance 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | ₹2.2 L | L3 | Rejected-Finance That the Bid is not L1 |
| Sl No | Description | Qty | Unit | A.K.ENTERPRISE L1 | TECHNO FAITH L2 | M/S R. K. ENTERPRISE L3 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling the existing E.I. work by Co's own tools & tackles and remove unnecessary,scrap items away from site by maintening normalcy as far as possible and deposit necessary materials to section office as per direction of EIC . | 1 | Item | 591 ₹591 | 1,000 ₹1,000 | 15,500 ₹15,500 |
| 2.00 | Supplying and fixing 415V, 160A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- LK/Siemens/ Schneider) | 1 | Item | 9,000 ₹9,000 | 8,500 ₹8,500 | 12,500 ₹12,500 |
| 3.00 | Supplying and fixing 415V, 200A TPN SFU open execution in existing SS enclosure/cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
(Make- LK/Siemens/ Schneider) | 1 | Item | 10,000 ₹10,000 | 8,000 ₹8,000 | 10,500 ₹10,500 |
| 4.00 | Supply of 4 Core XLPE Insulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make Polycab / KEI/ Havells/ Gloster as approved by E.I.C]
4 core 95 sqmm (from SS LT Panel to Digital X-Ray Room) | 135 | mtr | 1,025 ₹1.4 L | 975 ₹1.3 L | 450 ₹60,750 |
| 5.00 | Laying of 4 core 95 sqmm Al. armoured PVC/XLPE cable with 2X10 SWG GI wire making hole etc. as necy., mending good damages and painting as mentioned below :(from SS LT Panel to Digital X-Ray Room)
Vide page no F-1,F-3 Item no 2 & 5,6)
on wall by clamp | 87 | mtr | 85 ₹7,395 | 75 ₹6,525 | 250 ₹21,750 |
| 5.10 | Concealed in wall | 4 | mtr | 160 ₹640 | 150 ₹600 | 200 ₹800 |
| 5.20 | Thorough existing cable tray with binding wire | 20 | mtr | 20 ₹400 | 15 ₹300 | 200 ₹4,000 |
| 6.00 | Laying of one cable upto 150 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand | 24 | mtr | 90 ₹2,160 | 90 ₹2,160 | 200 ₹4,800 |
| 7.00 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
(vide pg no F-4 item no. 7.C)
4 core 95 sqmm | 4 | ea | 200 ₹800 | 250 ₹1,000 | 200 ₹800 |
| 8.00 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.
(vide pg no F-5 item no. 8a & 9)
4 core 95 sqmm | 4 | Set | 250 ₹1,000 | 350 ₹1,400 | 200 ₹800 |
Tender Value
Refer Docs
EMD Value
₹5,340
Closing Date
6 Mar 2026, 1:00 pmClosed
Assistant Engineer, KMC Electrical Sub-Division
Kolkata Medical College Electrical Sub-Division, P.W.Dte.Green Building, MCH Campus 88, College Street, Kolkata-700073.
Augmentation of power supply arrangement for Installation of Digital X-Ray machine at Lady Dufferin Victoria Hospital, Kolkata.
2026_WBPWD_1013233_1
WBPWD/AE/KMCESD/NIQ-144/25-26
Open Tender
ELECTRICAL WORKS ORG
10 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,340
29 May 2026
23 Feb 2026
9 Mar 2026
27 Feb 2026
6 Mar 2026
27 Feb 2026
Dismantling the existing E.I. work by Co's own tools & tackles and remove unnecessary,scrap items away from site by maintening normalcy as far as possible and deposit necessary materials to section office as per direction of EIC .
Supplying and fixing 415V, 160A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- LK/Siemens/ Schneider)
Supplying and fixing 415V, 200A TPN SFU open execution in existing SS enclosure/cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- LK/Siemens/ Schneider)
Supply of 4 Core XLPE Insulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make Polycab / KEI/ Havells/ Gloster as approved by E.I.C] 4 core 95 sqmm (from SS LT Panel to Digital X-Ray Room)
Laying of 4 core 95 sqmm Al. armoured PVC/XLPE cable with 2X10 SWG GI wire making hole etc. as necy., mending good damages and painting as mentioned below :(from SS LT Panel to Digital X-Ray Room) Vide page no F-1,F-3 Item no 2 & 5,6) on wall by clamp
Concealed in wall
Thorough existing cable tray with binding wire
Laying of one cable upto 150 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : (vide pg no F-4 item no. 7.C) 4 core 95 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. (vide pg no F-5 item no. 8a & 9) 4 core 95 sqmm
Replacement of existing connecting busbar with heat shrinkable insulation of SFU of Sub satation LT Panel with S&F 40mm X 5 mm Tinned copper Busbar as required (4 no bar approx length 1.5 mtr.).
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required (vide pg no G-2 item no. 4.b)
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc (vide pg no G-3 item no. 5d)
S&F digital Trivector energy meter 3 phase 4 wire ct operated class 0.5s (LK, Cat No. WR300BC52RS/ equivalent of Schneider/Seimens) on suitable size 19mm thick BWR grade bakelite as per direction of EIC.
S&F 160A/5A CT Coil class 0.2 ( Kappa Make)
S&F 2 A MCB ("C" curve, Legrand/LK/Seimens/ABB) on DIN rail on bakelite board of suitablesize for metering ckt protection
Supply & errection of special type Pilfer proof net guard of giving deep fabrication to suitable M.S. angle, flats and M.S. angle welded suitably for fixing on Floor covering the trivector meter and metering ct and prtection MCBs; should be sterdely and electrically welded in a measurement of front side of the panel board should be covered by 2 Nos. door palla made of 25mmX 5mm flat (column & vertical) and guard structure should be made of 35X35X5mm angle left & right side of the box will also be covered by M.S. grill with help of angle and flat to cover up fabrication will be complete in a compact position finally the protection should be painted with moisture proof red oxide primer and approved paint.
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
2911_Form.pdf
Tender Documents • 0.50 MB
suspension.pdf
Additional Documents • 2.91 MB
BOQ_2488840.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid