The Executive Engineer (E), BSNL ED-III, Kol
Room No. 322 3rd Floor, Burrabazar Telephone Exchange, Kolkata-7
Providing EI and Sub-meter, Tower earthing and LA, Free Cooling unit , AFD and Alarm system for BTS site at Ichhapore Metal and Steel Factory under Phase-IX.2, CTD, Kolkata.
2026_BSNL_290033_1
79/BSNL/ED-III/Kol/NIT/2026-27
Open Tender
Electrical Works
Item Rate
30 days
Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
Yes
BSNL COLLECTION ACCOUNT AO BSNL CENTRAL COLL ACCT,
₹4,883
Yes
7 Sept 2026
7 Sept 2026
18 Sept 2026
7 Sept 2026
17 Sept 2026
8 Sept 2026
8 Sept 2026 - 16 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.(Group C) | 2 | Points | - | - |
| 2Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. | |||||
| 2.1 | a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 3 | mtr | - | - |
| 2.2 | b )2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 3 | mtr | - | - |
| 3Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | |||||
| 3.1 | a) 3 x 1.5 sq. mm | 3 | mtr | - | - |
| 3.2 | b) 4 x 1.5 sq. mm | 3 | mtr | - | - |
| 4 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. | 2 | Nos | - | - |
| 5 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. | 1 | No | - | - |
| 6 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. | 1 | No. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
79NITIchhapurBTS.pdf
Tender Documents • 1.67 MB
BOQ_338291.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .