Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99.0 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC QUOTED L1 | |
| 2 | L2₹1.1 Cr+₹5.0 L (5.00%)Rejected-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L2 | Rejected-AOC NOT ADMITTED | |
| 3 | L3₹1.1 Cr+₹6.8 L (6.78%)Rejected-AOC PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L3 | Rejected-AOC NOT ADMITTED | |
| 4 | Rejected-Technical 1446 ELITE ENTERPRISES NORTH SOLAPUR NEAR SUSHIL MARATHI SCHOOL SOLAPUR MAHARASHTRA 413004 | SOLAPUR | MAHARASHTRA | 413004 | - | Rejected-Technical NOT ADMITTED | |
| 5 | Rejected-Technical FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | - | Rejected-Technical NOT ADMITTED |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
27 Nov 2021, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
MANUAL RESCUE AND OPERATION RESCUE OF SWIMMING POOL, DG SET, EDP SCHOOL AC PLANT, PUMP HOUSE ERANGLE AREA, PUMP HOUSE HAMLA, CENTRAL AC PLANT HAMLA, REPAIR / REPLACEMENT OF SUMMER APPLIANCES AT HAMLA AND ANNUAL MAINTENANCE CONTRACT FOR AMR AT HAMLA U
2021_MES_487544_1
8412/E8
Open Tender
Civil Works
Item Rate
330 days
HAMLA
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) BHANDUP
₹1.7 L
Yes
29 Dec 2021
11 Nov 2021
30 Nov 2021
11 Nov 2021
27 Nov 2021
22 Nov 2021
Amount
Supply & Fix new hermetically sealed compresor in existing window type AC, 1.5 Ton capacity including initial filling of refrigerant gas to the required pressure, brazing, electric/piping connection etc complete all as specified and directed, Make : Voltas / Shriram/Tecumseh/Kirloskar / Hitachi/LG / Blue Star.
- ditto- all as per item No. 1 above but for split type AC 1.5 Ton capacity.
- ditto- all as per item No.1 above but for split type AC 2 Ton capacity.
-dittoo- all as per item No.1 above but for Water Cooler 40/80 Litres capacity.
-dittoo- all as per item No.1 above but for Water Cooler 80/120 Litres capacity and 60/120 Litres capacity. Note for item Nos. 1 to 4: (i) The Contractor shall submit original purchase voucher alongwith manufacturer's test certificate and Guarantee Card etc. (ii) The quoted rates shall also be deeed to include to undertake Guarantee of one year from certified dated of completion by the contractor for free replacement of compressor and/or rectification of the same (including charging of gas) all as directed by the GE in case any defects are noticed (during Guarantee Period of 01 year) due to any reasons whatsoever may be.
Taking out window type air conditioner of capacity upto 1.5/2 TR of any make/type after disconnecting of electric supply and removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda, checking and replacing the spares like relay, capacitors, thermostat, fan motor, blades & blower and including servicing,overhauling and charging of refrigerant and testing including fixing back in its original location complete all as specified and directed.
Taking out split type air conditioner (both indoor and outdoor units) of capacity upto 1.5/2 TR of any make/type after disconnecting refrigerant pipes, drain pipe and electric connection and removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda, checking and replacing the spares like relay, capacitors, thermostat, fan motor, blades & blower and including servicing, overhauling and connecting of refrigerant pipe,drain pipe and charging of refrigerant and testing including fixing back in its original location complete all as specified and directed. NOTE FOR ITEM NOS. 6 & 7 (i) Spares will be measured and paid separately as supply only. (ii) Refrigerant gas will be measured and paid separately as supply only.
Replacement of corroded body base tray & connected portion of window type AC upto 2 Ton capacity (base tray made out of M S Sheet 18 Gauge and other portion with MS sheet 20 Gauge) including motor mounting frame, nuts/bolts of suitable size and spray painting with two coats of synthetic enamel paint over one coat of primer including replacement of damaged insulation etc complete all as specified and directed. Note : For replacement of the body, cost of dismantling of compressor etc including reassembling and gas charging etc as required at site shall also be deemed to be included in the quoted rates.
Taking out corroded body & frame of water cooler of 80 Litres storage capacity and replacement with new angle iron frame of size 40 x 40 x 6mm and cooler body with MS/CRCA sheet of 20 gauge, painting with two coats of synthetic enamel paint over a coat or red oxide primer by spray painting, including reassembleing & refixing of all parts etc complete all as specified and directed .
Supply only blower fan motor for 1.5/2 TR capacity window type air conditioner complete all as specified and directed.
Replacement of fan blades of motor for water cooler upto 150 Ltr capacity including testing etc complete all as specified and directed
Supply only blower fan blade for 1.5/2.0 TR window type air conditioner complete all as specified and directed.
Supply only blower drum of window type AC upto 1.5/2 ton capacity complete all as specified and directed. Make: Voltas/Carrier/Blue Star/LG.
Replacement of existing damaged outer cover of window type AC with 20 Gauge aluminium anodised sheet including moulding, screwing etc complete all as specified and directed.
Replacement of PVC cover grill of window type AC upto 1.5/2 ton capacity complete all as specified and directed.
Supply only starting capacitor 60 to 80 MFD complete all as specified and directed.
Supply only starting capacitor 80 to 100 MFD complete all as specified and directed.
Supply only starting capacitor 100 to 120 MFD complete all as specified and directed.
Supply only running capacitor of 36 MFD complete all as specified and directed.
Supply only relay for window type AC upto 1.5/2 Ton capacity complete all as specified and directed.
Replacement of relay for Water Cooler of 60 to 150 Litre storage capacity, complete all as specified and directed.
Supply only thermostat switch for window type/split type AC upto 1.5/2 Ton capacity complete all as specified and directed. (Make : INDOFOSS/RANUTRAL)
Manning operating and routine maintenance of swimming pool and its pump sets alongwith electrical panel board and chloronome plant including their periodical maintenance and repairs (excluding major assy/items/jobs as mentioned in Sch A Part II) all as specified in one shift of 8 hours consisting of the following :- (a) Vertical type pressure filter with 1/2" dia nozzle, complete with pumping set monoblock with 3 HP 3 phase electric motor complete-2 Nos (b) Pumping set mono block with 10 HP induction motor electric driven for pressure filter- 2Nos (c ) Suction sweeper trolley mounted 2' wide complete with pumping set monoblock with 3HP, 3 phase electric motor complete (d) Air compressor 125 cubic feet air per minute driven by 5HP induction electronic motor 3 phase, 415 Volts, 50 Hz including DOL starter etc complete -1 No. (e) Electrical control panel board complete with starter switches, MCB etc, all as specified and directed by Engr-in-Charge (f) LT panel board suitable for 3 phase 415 Volts AC supply wall mounted and 100 Amps MCCB incoming and MCBs in outgoing Location : INS Hamla
Supply only copper sulphate of super quality ISI Marked complete all as specisified and directed.
Supply only aluminium potash of super quality ISI Marked complete all as specisified and directed.
Supply only Soda Ash of super quality ISI Marked complete all as specisified and directed.
Supply only stable bleaching powder (calcium hypochloride with chlorine content not less than 30%) as per IS: 15738 : 2007 and 1065 : 1989 Marke : M/s Sree Rayalaseema Hi-Strength Hypo Ltd or Grasim industries Ltd or Bengal Chemichal & Pharmaceuticals.
Attendiing day to day internal Electric breakdown as light, Fan, Switch socket points etc. at INS Hamla area and NSB area by employing three shift, one Electrician in a Shifts for 08 hrs each shift for comprising replaceing of switches, sockets, Light fittings, starter, choke, Lamp holder, damaged wiring, ceiling fan etc. for making serviceable complete all as required at site or as directed by Engr-in-Charge.
Manning, operation including repairs with all consumables parts (excluding major assembly/items/jobs given in Sch A Pt II ) and periodical maintenance of the following diesel engine driven generating set with 24 hrs operation of three shift round the clock with one operator per shift complete all as specified and directed. (a) SET No 01 :- Engine Make :- Kirloskar Cummins, Make of Alternator : Kirloskar Electricals, Capacity : 160KW/200KVA, Location : 'B' Zone INS Hamla (b) SET No 02 :- Engine Make :- Kirloskar, Capacity : 127 BHP, Make of Alternator : Kirloskar Electricals, Capacity : 80KW/100KVA, Location : A' Zone INS Hamla (c) Set No - 03:- DG Set - Engine Make :- Kirloskar Cummins, Make of Alternator : Kirloskar Electricals, Capacity : 80KW/100KVA, Location : NICA INS Hamla (d) Set No - 04:- DG Set - Engine Make :- Kirloskar Cummins, Make of Alternator : Kirloskar Electricals, Capacity : 50KW/62.5KVA, Location : 'D' Zone sub stn INS Hamla (e) Set No - 05:- DG Set - Engine Make :- Kirloskar Cummins, Make of Alternator : Kirloskar Electricals, Capacity : 8KW/10KVA, Location : COMSON INS Hamla
M&L for carrying out 'B' check for following DG set all as per manufacturers instructions. Location: 'A' Zone - 1 No Note : Rate quote shall be deemed to be inclusive of spares and filters but excluding engine oil.
For 200 KVA
For 100 KVA
For 62.5 KVA
For 10KVA
Supply Only Engine oil 20W 40
Supply and replacement of diesel filter complete all as specified and directed
For 200 KVA
For 100 KVA
For 62.5 KVA
For 10KVA
Supply and replacement of Oil filter complete all as specified and directed
For 200 KVA
For 100 KVA
For 62.5 KVA
For 10KVA
Supply and filling coolent for 200/100/62.5/10 KVA DG set complete all as specified and directed
Manning and Operation of the following items in Three shifts per day (each shift 08 hrs continuous duration, operated by one operator in each shift including periodical maintenance/repairs (daily check and cleaning, monthly, quarterly, half yearly maintenance) with all consumables parts (except for major assembly/items/jobs ) of Central AC plant . (a) Central AC plant of capacity 2 x 26 ton (One stand by) comprising of compressors, motor, condensers, Chillers, AHU, refrigerant, piping, controls, pumps, water supply pipes and controls cooling towers, eletrical panels, instruments starters, strip heaters and repairs/replacement of control cabling/wiring including for the smooth and effiecient of AC plant to achieve desired inside conditions through out the given period. (Location EDP School INS Hamla)
Manning, Operation of electric driven pump set along with electric panel board and their periodical maintenance & repairs (excluding major Accessory / items / jobs as mentioned in Sch 'A' Part II) including controlling the valves of distribution lines for distributing the water in the area with one operator in a shift of 8 hrs for the following type/capacity of pumping set for 16 Hrs in 2 shift from 0800 to 2200 hrs) (i) Pumping set monoblock 5 HP - 03 Nos (Location - FSB Errangle village, Hamla)
Testing of water Supply and obtain the following the research and tested through NABL accredited Lab including submitting of test certificate to Engineer – in Charge complete all as specified. Details of tests to be carried out (i) Turbidity (NTU), (ii) PH, (iii) Total Hardness CaCO3 (mg/l), (iv) Sulphate (SO4) (mg/l), (v) Iron (Fe) (mg/l), (vi) Magnesium (Mg) (mg/l), (vii) E-coli or thermo tolerant coliform bacteria Note: The rate quoted deemed to include the cost of collecting sample of water in four different locations from FSB Erangal & INS Hamla area and the test to be carried out in the first and seventh month of the contract.
Supply only Altoc GP grannule
Comprehensive Annual Maintenance Contract at INS Hamla. The scope includes a. Repair and replacement of all items viz. SCADA compatible energymeter monitoring modules, connectors, OFC to ethernet convertors, SMPS (power supply) as required. The above excludes OFC accessories b. Quarterly visit of trained technician for checking overall system configuration, software status, connections, network configuration. c.. Visits in case of specific service call from clients d. Remote software and system support as required by the engineer in charge
Comprehensive Maintenance of OFC network including a. spares, splicing, jointing etc. as required. b. Cost of Broad band for a period of 12 months from the date of start of AMC. c. Cost of Static IP for a period of 12 months from the date of start of AMC.
Manning, Operation of electric driven pump set along with electrical panel board and chloronome plant including their periodical maintenance and repairs with all consumables and spare parts (excluding major Accessory / items / jobs as mentioned in Sch 'A' Part II) controlling the valves of distribution lines for distribution water in the area with one operator in a shift of 8 hrs for 24 Hrs in 3 (Three) shift for the following type/capacity of pumping set :- (a) Operation of two pump set mono block out of four pump set : 15 HP - 02 Nos & 10 HP-02 Nos, - KV Pump house (b) Operation of one pump set mono block out of two pump set as required : 7.5 HP - 02 Nos : NSB Well pump house. (c) Operation of one pump set mono block out of two pump set as required : 3 HP pump Set -02 Nos & DG Set 10 KVA -1 No: Location :Nausena baug, KV School, KV staff qtrs sea Hawk Bldg and MAP bldg at INS Hamla)
Manning, Operation of electric driven pump set along with electric panel board and their periodical maintenance & repairs (excluding major Accessory / items / jobs as mentioned in Sch 'A' Part II) including controlling the valves of distribution lines for distributing the water in the area with one operator in a shift of 8 hrs for the following type/capacity of pumping set for 24 Hrs in 3 (Three) shift for the following type/capacity of pumping set :- (i) Pumping set monoblock 10 HP - 04 Nos (Main Pump House) (ii) Pumping set monoblock 10 HP - 01 Nos (Sea Eagle - I Pump House) (iii) Pumping set monoblock 7.5 HP - 01 Nos (Sea Eagle - I Pump House) (iv) Pumping set monoblock 10 HP - 02 Nos (C Zone Pump House) (v) Pumping set monoblock 10 HP - 02 Nos (A Zone Pump House)
Comprehensive maintenance of Central AC Plant of capacity 11TR X 2Nos.comprising of following equipment mentioned below complete all as specified and directed by Engineer-in-Charge (a) Compressor model Nos :- Make:- Copeland Scroll (16K6005ET) (b) Compressor motor 3HP-02Nos. (c) Condenser water pump set mono block 3HP-02Nos. (d) Air handling unit with blower motor -01No. (e) FRP Cooling tower with CT Fan- 01No. (f) Electrical control panel cubical type floor mounted complete with main switch, MCCBs, MCB's, voltmeter, Ammeter, auto matic star delta starter for compressors, pumps, CT fans, condenser etc. complete-01 Set. (g) Control devices such as expansion valve, thermostat solenoid valves, HP/ LP/ OP cut outs with panel board installed gauges-01Set (h) Digit type thermometer-01Set (j) Air supply duct with grill diffusers, dampers and pre heater & re heater back of each complete-01Set (k) Condenser MS piping 50/40mm dia with valves, pressure gauge, temperature gauge, complete-01Set. Note :- Any damage caused during handling/repairing shall be made good without any extra cost to department.
Rewinding of unserviceable electric motor 3 Hp, 3 phase 50 Hz 415volt of following capacity pump set complete comprising as under :- (i) Disconnecting & removing the electric motor from installed position including, loading, unloading and transporting to approved workshop. (ii) Taking out the existing burnt winding from the motor including rewinding complete with super enameled copper winding wire of existing gauge including all insulating material such as insulation paper, sleeves, tape, varnish etc. complete for class 'F' insulation. (iii) Transporting the motor back to the location, reinstalling in original position including alignment, electrical & water connection, commissioning and testing for 8hours continously to check the RPM etc. to the satisfactory performance etc. complete.
Over hauling of compressor motors, (blower motor) after disconnecting electric supply connection, base nut bolts and removing from base plate & transporting to workshop & back complete opening, pully, end cover plate replacing defective bearing greasing complete and refixing old existing location and reconnection of electric supply including necessary level and alignment, buts bolts, gaskets etc complete with following capacity of motors:-
Material and labour for HVE-11 expansion valve of AC plant capacity 11TR including taking down unserviceable valve complete all as specified and directed by Engineer-in-Charge at Doom hall. Make : Sporlon or equivalent
Pumping down the plant to preserve the existing in refrigerant gas & leak testing of plant by charging of nitrogen gas in to entire plant & monitoring for 24hrs to find the leakages, rectification of leak by brazing & replacement of necessary gasket packing wherever required including copper tubes of suitable size vacumising of the plant by vacum pump & keeping 24hrs for pressure testing including rectification of leakages if any finally recharging of existing refrigerant gas to the plant and topping up of refrigerant if required to maintain the standard pressure complete testing of the plant for smooth functioning complete all as specified & as directed by Engineer-in-Charge
Material and labour for disconnecting condenser for descaling, plugging them & providing of 15mm tee out let for local circulation of mild acid solution in the condenser (separate container and small pump set to circulate diluted acid solution to be used) PH value of solution to be circulated & to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be used for descaling purpose after 2 to 3 hours of cleaning if ph value remains less than flush with fresh water mixed with sodium carbonate tubes and cleaning with nylonbrush after closing the end covers, circulating diluted acid solution as specified above, to maintaine PH value as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure of capacity 2x11 TR Working 22 TR (11 TR Stand by) plant complete all as specified & directed by Engineer-in-Charge.
Supply and charge refrigerant 407c Gas ISI marked.
Taking down old unserviceable pre filter and supply and fix new pre filters efficiency 90% down to particular size of 10 micron double knitted twisted polymer fabric (washable) rated with press drop of 6 mm WC, including aluminium anodized frame work of 16 SWG to be mounted in filter assembly for Suitable size complete all as specified and directed. Make:DYNA/ASPAWYMAN/MHP as approved
Replacement of unserviceable 2KW Heater strip for AC plant complete all as specified and directed.
Removing the unserviceable solenoid valve 5/8" flare from the liquid line and supply and fix new solenoid valve 5/8" suitable for AC plant of various capacities complete with all as specified and as directed by Engineer-in-Charge
Removing the unserviceable pressure gauges HP/LP/OP from existing position and supply and fixing new pressure gauge of capacity 0 to 30Kg. / square centimeter complete with necessary accessories all as specified & directed by Engineer-in-Charge
Removing the unserviceable water pressure gauges from water line & supplying and fixing new water meter up to pressure 7Kg. / square centimeter complete with necessary accessories all as specified & directed by Engineer-in-Charge
Material and labour for scraping cleaning & preparation of external surface & painting complete installation of 11 x 2 TR (22TR capacity) including compressor, motor, piping, cooling tower, condensor, AHU & panel board etc with two coats of synthetic enamel paint over a coat of primer as per direction on colour code as given including writing SM & MES numbers complete all as per specified & as directed by Engineer-in-Charge
Replacement of old unserviceable thermostat with new thermostat suitable(-)18 deg C to (-) 23deg C cold storage plant complete all as specified and directed.
Replacement of old unserviceable liquid line filter with new liquid line filter complete all as specified and directed. Make: Danfoss or equivalent as approved by GE.
Supply and fix single phase preventor complete all as specified and directed. Make: Minilec or equivalent as approved by GE.
Supply and fix in repairs CI Butter fly valve slim seal design with nitrile rubber lined seal with clutch lever (P10 or PN 16) as per IS 13095 of size 80mm bore .Make: AUDCO/SANT/SIR as approved.
Ditto - as per item No 59 above but 65 mm bore.
Ditto - as per item No 59 above but 50 mm bore.
Supply and fix in repairs Gate Valve of 40 mm Bore complete all as specified and directed. Make: HM//L&T/kirloskar as approved.
Cleaning of Air handling ducts(GI/AL) internally by using special T&P like robortic arm, air compressor, air jet nozzles, flipper, vaccum pump and a suction blower with hepa filter and check before and after the cleaning all as directed by the Engineer-in-Charge
Nitrile rubber insulation of one layer of 19mm thickness sticking on surface by using approved adhesive and sealing the joints by weather proof tape .
S & F New scroll compressor suitable for 11 TR package unit
Taking out existing unserviceable thermostat switch of water cooler and Supply & fix new thermostat switch for water cooler of any capacity including testing etc complete all as specified and directed. (Make:INDOFOSS/RANUTRAL)
Supply and fix in repairs blower motor capacitor 4 MFD etc complete all as specified and directed. (Make : ASIAN/KEIL/EPCOS)
All as per item No. 67 above but 6 MFD capacitor. (Make: ASIAN/KEIL/ EPCOS)
Supply only over load protector No 1022 in window type AC upto 1.5/2 ton capacity complete all as specified and directed.(Make : USHA/ RANUTRAL)
Taking out existing unserviceable over load relay and supply & fix new over load relay in water cooler upto 150 ltrs capacity etc complete all as specified and directed.
S & F in repairs sheet metal enclosure with 3 pin 20 Amp earth plug & socket, also with and including single pole MCB of 20 Amps, 240 Volts, 'C' Series, 10 KA etc complete all as specified and directed.
Taking down existing unserviceable cable on wall/ceiling and supply and lay 1100 Volt grade PVC insulated 3 core 4 Sqmm stranded copper conductor cable suitable for indoor unit to outdoor unit complete all as specified and directed.
Taking down carefully split type AC upto 2 Ton capacity & refixing inner & outer unit at new location alongwith existing frame work, bracket, refrigerant tubing, cable, stablizer etc and making good existing surface to match with the adjoining surfaces etc complete all as specified and directed.
Supply, fixing, clamping and jointing copper tubing in replacement of 3/8" dia for suction line and for liquid discharge line duly insulated with suitable insulation material for split AC including necessary soldering, flaring work, jointing, testing etc, making hole in wall for passing though pipe and making good to the disturbed surface to match with the adjoining surfaces etc complete all as specified and directed.
Supply & Lay PVC Nylon braided pipe 20 mm bore heavy duty including fittings to drain out condensed water of split AC including cutting of floor / wall & making good after laying of pipe to match the existing surface etc complete all as specified and directed.
Supply & fix in repair, push cock / lift cock 15mm bore of brass, chromium plated, ISI marked for water cooler of any capacity etc complete all as specified and directed.
Supply and fix in repair 12mm dia flexible PVC connection pipe upto 600mm long with brass nuts & washers at both ends suitable for water cooler etc complete all as specified and directed.
Supply and fix water tray made out of GI sheet 2 mm thick for water cooler any capacity with out let system connection provided with and including PVC nylon braided pipe of 20 mm dia upto 3 mtr length and also connecting to drain pipe etc complete all as specified and directed.
Supply & fix PVC pipe 25 mm bore with and including fittings and necessary saddles fixed on wall etc for outlet drain etc complete all as specified and directed.
Removing existing unserviceable electronic circuit control board of split AC unit upto 2 ton capacity and supply and fixing new electronic PCB & display board kit in the indoor unit including testing etc complete all as specified and directed.
Supply only remote sensor handset suitable for split AC upto 2.0 ton capacity etc complete all as specified and directed.
Supply and fix in repair remote sensor plate suitable for split AC upto 2.0 ton capacity etc complete all as specified and directed.
Supply and fix in repairs multipurpose door lock with duplicate key of water cooler of any make & capacity etc complete all as specified and directed.
S & F in repairs 15mm bore gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes etc complete all as specified and directed.
S & F in repairs 15mm bore ball brass valve high pressure with polythene float & fly nut screwed for iron pipes etc complete all as specified and directed.
Supply only refrigerant (R-134A) gas as per requirement complete all as specified and directed.
Supply and fixing sediment filter for blue star water cooler 40/80 ltrs capacity
Supply and fixing Carbon filter for blue star water cooler 40/80 ltrs capacity
Supply and fixing SV Valve HNS No - 84811000
Supply and fixing UV lamp HNS No - 85044090
Supply and fixing LED HNS No - 85394900
Supply and fixing PCB HNS No - 85044090
Supply and fixing UV Sensor HNS No - 84219900
cooltech engineering services
shakti engineering and electrical works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .