| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.3 LAccepted-AOC | 1 | Accepted-AOC Lowest | |
| 2 | 2₹13.9 L+₹1.6 L (13.1%)Rejected-Finance COLLEGE ROAD NEAR MUNCIPAL COLONY GURDASPUR PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | 2 | Rejected-Finance Higher | |
| 3 | 3₹16.5 L+₹4.2 L (34.3%)Rejected-Finance | 3 | Rejected-Finance Higher | |
| 4 | Rejected-Technical | - | Rejected-Technical not enlisted for requisite category | |
| 5 | Rejected-Technical | - | Rejected-Technical not enlisted for requisite category |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
30 Jun 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Amritsar
GE Amritsar PIN-143001
MANNING AND OPERATION OF 66 KV GRID SUB STN UNDER GE AMRITSAR CANTT
2021_MES_448129_1
GE/ASR-087/2021-22
Open Tender
Civil Works
Item Rate
335 days
GE Amritsar
Class E, Category dv
8 documents required · 8 mandatory
₹500
GE Amritsar
₹36,000
Yes
6 Aug 2021
3 Jun 2021
1 Jul 2021
3 Jun 2021
30 Jun 2021
17 Jun 2021
60 days
Amount
Manning and operation and routine maintenance of 66 KV Grid Sub Stn, in three shifts comprising of the following assests :- A' 66 KV Assests and connected accessories :- (i) Transformer 66 KV/11 KV 4 MVA-02 Nos complete with protection control cable and connected accessories. (ii) Stand by Transformer 66/11 KV 4 MVA-01 No complete with protections control cable and connected accessories. (iii) 72.5KV,31.5 KA, 1600 A, SF-06 type circuit breaker - 04 Nos (iv) Control and relay panel for 66/11 KV Transformers 4MVA-03 Nos. (v) OLTC panel-03 Nos. (vii) 72.5 KV, 31.5 KA CT's of ration 100-50/1-1-1A - 12 Nos (viii) Bus bar of 66 KV Grid - 01 Set (ix) Earthing pit- 04 Set (x) Protection control cable - 01 Set (xi) Lightening Arresters (Gapless) - 04 Set (Each of 03 Set) (xii) 11KV, VCB Panel- 11 Nos (xiii) ACDB & DCDB Panel- 02 Nos (xiv) Transformer 11 KV/0.433 KVA 100 KVA – 01 Nos. (xv) Bty bank consisting of 110 Nos battery of 02 Volt 100 AH- 01 Set (xvi) Bty charging panel - 01 Set (xvii) Control and relay panel for 66KV incoming -01 Nos. (xviii) 72.5 KV, 31.5 KA, 1250 Amp isolator without earth switch- 04 Nos (xix) Do but without earth switch- 01 Nos (xx) Capacitor bank - 03 Nos B Operating staff to be deployed :- (i) Electrician (HS) - Three person/day in three shift having three years diploma in Elect Engineering with 2 years experience of working in a substation of 33 kV and above or ITI diploma in electrical trade with 5 years experience in working in a substation of 33 KV and above or any retired sub station attendant of any state electricity department will conversant with such job having educational qualification not less than 10th class from a recognized institute/Board. Experience Certificate in each case shall be submitted. (ii) Electrician (Semi Skilled) - Three persons per/ day in three shift having 3 years diploma in electrical engineering or ITI in electrification trade with five year experience in the relevant trade or any retired Sub Stn Attendant of any state electricity department conversant with such job and educated qualification not less than 8th class from the recognised school/institutes.
Note :- (a) Period of one shift - 8 Hours. (b) No of shifts to be deployed per day - 03. (c) Nature of Duties of operation staff (i) Sub Station attendant / Electrician have to operate and maintain all the assets listed under item No. 1(A) here in before. (ii) Maintaning and recording of the records of all the Instruments all as directed by Engineer-in-Charge and register/log sheet will be provided by contractors. (iii) Monitoring of periodical functioning of the instruments listed in Sub Station standing order/particular splecifications as per laid down periodically. (iv)Recording daily break down /shut down in the log sheet other than reading such as trip record, breakdown its duration, preparing permit slip etc. (v) Carrying out necessary periodical test of earthing of complete Grid quarterly and recording it on test sheet. (vi)Testing of DC batteries healthiness, checking of gravity of batteries, functioning of battery bank replacement of worn-out fuses, weekly and making the test/record sheet. (vii) Testing, cleaning, checking of bty terminal, Ammeter, voltmeter periodically and maintain log book for running of Gen Set of capacity 35 KVA. (viii) Maintaining and monitoring capacitor bank and power factor.
Note :-1. There is no provision of duty reliever in the contract it is contractor responsibility to fulfil the requirement in labour (Regulation and abolitions) Act -1970 with its latest amendments at his cost . No claim whatsoever will be entertained to this effect by the department. The cost of duly reliever will be deemed included in the rate quoted by the contractor.2.Maintenance /Cleaning of installation area by removing weeds /unwanted vegetation will be the responsibility of the contractor . The rates quoted to have include cleaning of area (D) PROTECTIVE CLOTHING/UNIFORM/TOOLS :- The Electrician (HS) and Electrician (Semi skilled) shall wear uniform as approved by the GE/ Engineer-in-Charge. The tools kit consisting of Insulating plier, screw drivers, DE Spanner set shall always be in possission of the duty person. The uniform and tool kit shall be arranged by the contractor. Elect Hs & Elect SS will not be attand to enter the sub stn without protective clothings. (E) Duty Roster. Necessary duty roster shall be prepared by the contrcator every months and approved by JE/Engineer-in-Charge monthly. (F) One mobile set to be provided at 66 KV Sub Stn permanently for communication by contractor without extra cost. (G) Payment of wages : The Garrison Engineer is the principal employer as such payment to staff deployed shall be made not less than minimun wages as govt policy. Payment to staff deployed to made through bank cheque & evidence to be produced as directed. (H) Penal Charges. The fwg panel charges are charged as under:- (i) Absent of duty attandent. Recovery @ Rs. 784/- per day per shift for Electrician (skilled). (ii) Absent of helper Recovery @ Rs. 609 / per day per shift for helper (semi skilled). (iii) Not carring out the periodical test as per periodicity, recovery @ Rs. 5000/- lump sum. (iv) Non cleaning of the area recovery @ Rs. 5000/-per month Note :-The operating personal shall be provided with proper protective clothing & this clothing shall be worn by them while on duty. In case of any accident injury fatal or partial i. e. Disability to work people, the contractor shall be solely responsible for the same and all claims as provided in the labour compensation act shall be borne by the contractor. Accordingly, the contractor will get the operating staff insured from any govt recognized insurance agency. The contractor will have no extra claim whatsoever on this account. The contractor will produce such document on demand. JE (E/M) will however ensure that all protective measure have been adopted by the contractor and will keep the Engineer-in-Charge well informed about it.
Material and labour for complete routine testing of 66/11 KV Substation to be carried by the Protection department of PSPCL (Punjab State Power Corporation Ltd) including relay calibration of all Overcurrent, Earth fault and Differential relay, testing of CTs,earthing connections etc and submission of report to the department complete all as specified and directed. The quoted rates include visit and testing charges by PSPCL team for one day complete all as specified and directed by Engr-in-Charge.
Supply and filling of distilled water for battery bank of 66 KV substation including cleaning of batteries , tightening of loose connections, cleaning of batteries complete all as specified. The PVC container required for carrying the distilled water to be provided by the contractor.
Supply and spraying glyphosate 41% SL Glykol Herbicide to remove vegatation from E/M Installations complete all as specified and directed by Engr-in-Charge
Attending complaint of VCB 11KV, 630A on required basis for checking of fault including checking of wiring circuit for defects and repair replacement of minor parts such as thimble, connectors etc complete all as specified and directed by Engr-in-Charge.
TRIVENI CONSTRUCTIONS
M/S BALWINDER SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .