Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical all Doc Acceped |
| 2 | Accepted-Technical | Accepted-Technical all Doc Acceped |
Tender Value
₹5.6 L
EMD Value
₹28,000
Closing Date
8 Dec 2025, 3:00 pmClosed
VC HPDA
HPDA PREET VIHAR HAPUR
Work of electrification for godown number G 27 to G 40 located in Transport Nagar Scheme
2025_HPDA_1094162_1
287/se/hpda/2025
Open Tender
Electrical Works
Percentage
120 days
hapur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
VC HPDA
₹28,000
Yes
23 Jan 2026
27 Nov 2025
8 Dec 2025
27 Nov 2025
8 Dec 2025
27 Nov 2025
S/E of Double pole stucture ( FOR POLE / PLINTH MOUNTED TRANSFORMER TYPE SUBSTATION )12mt. long 410 SP-62 ST pole (259 Kg) support grouted in 1:3:6 (cement coarse sand 6 graded stone aggregate 40 mm nominal size) including 30 cm high plinthing from ground level with the cost of 3 no 100 x 50 x 6mm 2.24 Mr long Chanel and 3 no. 75 x 40 x 6mm 2.24 Mtr lon Chanel and With D.O. Fuse set , T.P.M.O. switch , anticlimbing device and paintig of pole Complete with all material lab. T&P etc required for proper completion of work or as direction of E/I. (A.R. 2025-26)
S/F of danger board with clamp nut & bolt etc all complete. SOR. NO. 1109/18
Supplying and erection of 11 kV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. DSR 2022 SI NO. 13.10 (312x0.85212=265.86)
Supply, Installation, Testing and commissioning of 11/0.44 kv,100KVA Level 2 rating Aiuminium wound distribution Transformer complete as per UPPCL specification etc all complete .(A.R.2025-26) 100 KVA
S/E of 120 sqmm X 3 C + 1 x 95 sqmm + 1 x 16sqmm XLPE insulated ABC bare messenger wire etc complete as per direction and approved by E/I. (A.R. 2025-26)
S/F of suspension clamp suitable for hanging of various size ABC conductor on pole etc all complete as required. (P.S.R)
Supply and burying earth electrode for lightning conductor of 600mm x 600mm x 6.0 mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia. G. I. pipe for watering funnel, 30 cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal / coke and salt at least 150 mm thick alround etc. as per directions of E./Ic. complete in all respect. SOR NO.-703/18
Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect.SOR NO.-717/18
Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects SOR 627/2018
Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge.PWD SOR 504/2018 (j) 120 sq mm SIN-504(m)
S/Fof pole mounted type CMS TPN distribution box Sintex size 400 X 300 X 190 MM & 4 Nos. 40 X 50 mm aluminium bus bar with ingress protection to IS 8623 cable entry from bottom & /or sides shockproof & rustproof, suitable for polluted atmostpheres were high working tempreture & higher arc resisteance witherproof & maintenance free complete with supporting clamp i/c locking arrangement & painting etc complete as per direction of E/I. (P.S.R)
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 65 and above protection complete in all respect.SOR No. 1421 CAT - AAA /2018 ( make - philips / crompton/ bajaj / havells)
S/F of PG clamp/connector suitable for connecting of various sizes ABC cable including insulating cap etc complete as per direction of E/I.. (P.S.R)
S&F of 32 Amp. 415 V metal clad T.P. rewireable type switch fuse unit on angle iron bracket complete in all respect. SOR: 2018 /315
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 10 sq. mm 4 core
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.47 MB
T811.pdf
Tender Documents • 0.86 MB
BOQ_2011636.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .