Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC 204 258 RAM NAGAR MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹29.6 L+₹5.3 L (22.1%)Rejected-Finance N A | NA | NA | 121004 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹29.9 L+₹5.7 L (23.5%)Rejected-Finance N A | NA | NA | 121004 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹30.6 L+₹6.3 L (26.2%)Rejected-Finance H NO 154 VILLAGE SHIKARPUR PO NAJAFGARH NEW DELHI 110043 | WEST | DELHI | 110043 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹30.9 L+₹6.7 L (27.7%)Rejected-Finance PLOT NO 17 GF PRATAP NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
16 Jul 2024, 6:00 pmClosed
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
REPAIR/ REPLACEMENT TO WPC SCREEN WALL, CHAIN LINK FENCING, PRECAST RCC JALI, INTERLOCKING TILES AND OTHER CONNECTED ITEMS IN CENTRAL AMENITIES, COMD HUTS AND MESSES IN THE AOR OF AGE B/R-II UNDER GE (EAST) DELHI CANTT-10
2024_MES_662077_1
GE/DE-18/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE (EAST) DELHI CANTT-10
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Yes
GE (EAST) DELHI CANTT-10
₹98,000
Yes
5 Sept 2024
25 Jun 2024
18 Jul 2024
25 Jun 2024
16 Jul 2024
9 Jul 2024
Amount
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
M&L for brick work with sub class 'B' straight or curved on plan exc 6m mean radius and built in CM 1:4 complete all as specified and directed.
Taking down cement plaster on brick walls etc including raking out joints hacking for key scrubbing down with water etc all as directed.
M&L 10mm thick polymer modified readymix cement base plaster as per manufacturer instruction on fair / unfair faces of brick work or concrete surfaces & finishing the surface even & fair as per manufacturer instruction complete all as specified & directed. (Make: Ultratech readiplast or equivalent as approved by GE).
M&L rendering 15mm thick in cement mortar (1:6) finished even & fair on brick/concrete surfaces including taking down cement plaster on brick walls etc complete all as specified and directed.
M & L for 15mm thick rendering in cement mortar 1:4 on fair face of brick walls/ concrete surfaces and finished even and fair without using extra cement in any position incl scafolding as required etc, complete all as specified and as directed.
M&L for prepration of newly plastered surfaces of wall and applying 2mm thick birla white wall care putty complete all as specified and as directed.
M&L for prepration of new plastered surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
M&L Preparation of new steel and iron surfaces of any description over 10cm in width or girth , priming with a coat of red oxide primer and applying two coats of synthetic enamel paint complete all as spd
Preparation of old steel and iron surfaces of any description over 10cm in width or girth, and applying one coat of synthetic enamel paint complete all as spd.
M&L for two coats of floor paint (Indigo paints and equivalent) for external flooring and kerb stones etc including preparation of old/new floors, shade and patterns for colour is approved by GE complete all as specified and directed.
M & L in repair angle iron posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E complete all as directed by Engr-in-Charge.
M&L for preparation of newly plastered surfaces of walls, ciling and applying two coats of oil bound distemper over a coat of interior primer complete all as specified and as directed.
S & F in Repair galvanised 2 strand , steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and staining and fixing to any type of standard rails straining bolts , including securing or tying at crossing with and provision of galvanised mild steel wire , staples or steel pins etc,(each line wire to be measured) complete all as specified.
S&F in repair factory made steel fibre reinforced (SFRC) Drain covers without frames incl necessary hold fast/hooks of (Heavy duty) 600x450x70mm rectangular complete all as specified. Make Kreative concrete Company Product Code DC - 01 or equivalent as approved by GE.
Demolition in cement concrete in ground floor and paving not exc. 15 cm thick below or above ground level complete all as specified and as directed.
Dismantling fencing wire mesh, any type complete all as specified and as directed.
Supply only MS galvanisd Chain link fencing, any size or type complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed by Engr-in-Charge.
S&F in repair 10mm round bars of gread Fe-410-W (Part I) (Gde.E-250) quality-A or Fe 290 (Gde -E-165) for tying /tightening wire mesh complete all as specified and directed.
Excavating in soft/ loose of soil in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface
S&F of RCC Precast Concrete Compound wall having RCC Post (M-30) of size 150mm X 150mm X 2435mm height vertical 'H' section having grooves of suitable size including 7 bars of 3 or 4mm HTS with stressing system and embedded 600mm in ground including Provn of 6 Nos of Precast Concrete RCC Panels (M-30) between two post of size 2100mm x 300mm x 50mm thickness including 4 bars of 3 or 4mm HTS with stressing system complete all as per manufacturer's instructions and all as specified by Engr-in-Charge. Note :- (a) Above ground level height will be measured for payment purpose. (b) Excavation of post holes for fixing of columns shall be measured separately. (c) The post may be fixed to the ground by digging a hole 500 x 500 x 600mm and filled with 1:3:6 concrete after the post has been aligned in these holes PCC in foundation shall be measured and paid separately. Make- Surya Enterprises, Density Precast, Global Precast, Trilok Precast Pvt Ltd or equivalent as approved by GE.
M&L in repair for providing precast cement concrete louvers and jallies, 35 mm thick type B- 0, 1:2:4 using 12.5mm graded stone aggregate (measured solid) including all moulding and necessary form work and set in cement mortar 1:4 complete all as specifed and as directed.
S&F precast RCC coping/post of size 600x100x50 mm suitable for fixing of RCC Jallies in vertically & horizontally including necessary moulds and grooves as required in shape and size complete all as specified and directed.
S&F Machine pressed precast concrete interlocking glazed paver block with grey cement and pigment of any shape and size conforming to IS 15658 - 2006 of 60 mm thickness and M - 35 grade including 50 mm sand cushion including packing joints etc after dismantling old existing tile complete all as specified and directed.
M&L in repair Chequered cement concrete tiles 20cmx20cmx25mm thick, set, jointed with grey cement and pigments and pointed in neat cement slurry over and icluding 15mm thick screed bed or bedding layer in cement mortar 1:6, after dismantling tiles with backing coat of cement mortar complete all as specified and directed.
Providing and fixing "RAJSHRI" Brand factory made WPC railing combining WPC board/Fancy designer type grating and WPC frame 100% solid WPC (wood polymer composite) railing of required length and of 2' to 2.5' height , comprising of virgin PVC resin of K value 58-60 (Suspension Grade) , Calcium Carbonate and natural fibres (Wood Powders/rice husk//wheat husk) and non toxic additives, made from single extrusion process, WPC foam board with having minimum density 650kg/cbm and WPC frame having minimum density and support vertical frame lengths including dismantling of existing RCC jallies with frames complete all as specified and as directed. (Make : Rajshree or equivalent).
M & L for 75 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing completed all as specified and directed.
Demolition and breaking up drain pipes (SGSW, PVC or AC) upto 150 mm dia jointed in cement mortar complete all as specified and as directed.
M&L SGSW drain pipes 150 mm dia laid in trenches and jointed in CM (1:3) complete all as specified and directed
M&L cement concrete bed (1:4:8) type D-2 using 40mm graded stone aggregate as in bed to drain pipe 150mm bore SGSW including formaing cradels in complete all as specified and as directed.
S&F in repair PVC (SWR) pipes single socketed 110 mm bore in any length with rubber ring joints fixed to walls
S&F in repair PVC (SWR) bends any radius 110 mm bore
M/s Sree Baba Traders
MAA SANTOSHI ENTERPRISES
M/s Shubh Enterprises
M/s Durga Traders
Vipul Construction
STAR CONSTRUCTION CO
Akhil Enterprises
LAXMI GROUP
imran construction company
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .