| Sl No | Description | Qty | Unit | ASIF IQBAL KHAN (KHAN CONSTRUCTIONS) L6 | JP Infratech L9 | Raina Builders and Suppliers L4 | M/S TRANS TECH ENGINEERS L5 | M/S A A ENTERPRISES L1 | M/S SINGH ELECTRICALS L2 | M/S SIGMA CONSTRUCTION L3 | M/S K.K ELECTRICALS L10 | M/S PARAS ELECTRICAL L7 | M/S SOHTRA & CO L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Supply, Erection, Testing & Commissioning for Creation of 250 KVA Sub-Station for Electrification of Auditorium and Common room for Boys & Girls including parking stores, lift & ramp etc. at CD Hospital Bakshi Nagar, Jammu | |||||||||||||
| 1.01 | Complete materials for Sub-Station 250 KVA, 11/0.433, 3- Phase Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2 (Copper Wound) substation. | 1 | No. | 5,50,000 ₹5,50,000 | 6,28,000 ₹6,28,000 | 5,30,000 ₹5,30,000 | 5,10,000 ₹5,10,000 | 4,75,000 ₹4,75,000 | 5,20,000 ₹5,20,000 | 5,15,000 ₹5,15,000 | 6,50,000 ₹6,50,000 | 4,95,000 ₹4,95,000 | 4,58,000 ₹4,58,000 Lowest |
| 1.02 | ST Poles 9 Mtr. Long | 2 | No. | 17,000 ₹34,000 | 16,000 ₹32,000 | 16,000 ₹32,000 | 15,000 ₹30,000 | 15,000 ₹30,000 | 16,000 ₹32,000 | 17,500 ₹35,000 | 20,000 ₹40,000 | 17,500 ₹35,000 | 14,000 ₹28,000 Lowest |
| 1.03 | 185mmsq(2ckt)cable,1.1kv Grade, PVC insulated standard conductor FRLS type | 44 | Mtr. | 400 ₹17,600 | 150 ₹6,600 Lowest | 500 ₹22,000 | 400 ₹17,600 | 210 ₹9,240 | 400 ₹17,600 | 400 ₹17,600 | 400 ₹17,600 | 650 ₹28,600 | 1,100 ₹48,400 |
| 1.04 | ACSR Rabbit Conductor | 50 | Mtr. | 60 ₹3,000 | 70 ₹3,500 | 50 ₹2,500 | 120 ₹6,000 | 30 ₹1,500 Lowest | 50 ₹2,500 | 50 ₹2,500 | 60 ₹3,000 | 175 ₹8,750 | 300 ₹15,000 |
| 1.05 | 11 KV Disc insulator with fittings | 3 | No. | 400 ₹1,200 | 350 ₹1,050 | 350 ₹1,050 | 450 ₹1,350 | 300 ₹900 | 500 ₹1,500 | 400 ₹1,200 | 300 ₹900 | 250 ₹750 Lowest | 350 ₹1,050 |
| 1.06 | 11 KV Pin insulator with fittings | 6 | No. | 300 ₹1,800 | 200 ₹1,200 | 350 ₹2,100 | 190 ₹1,140 | 350 ₹2,100 | 300 ₹1,800 | 300 ₹1,800 | 200 ₹1,200 | 150 ₹900 Lowest | 10,220 ₹61,320 |
| 1.07 | GI Channel/Angle/Flat of Size including Clamps | 300 | Kg | 140 ₹42,000 | 140 ₹42,000 | 130 ₹39,000 | 131.87 ₹39,560 | 60 ₹18,000 Lowest | 120 ₹36,000 | 80 ₹24,000 | 130 ₹39,000 | 100 ₹30,000 | 130 ₹39,000 |
| 1.08 | 11 KV LA (Stn. type) | 1 | Set | 6,000 ₹6,000 | 6,500 ₹6,500 | 3,500 ₹3,500 Lowest | 5,500 ₹5,500 | 4,000 ₹4,000 | 4,000 ₹4,000 | 5,000 ₹5,000 | 3,700 ₹3,700 | 6,500 ₹6,500 | 4,500 ₹4,500 |
| 1.09 | 11 KV HG Set | 1 | Set | 6,000 ₹6,000 | 3,500 ₹3,500 Lowest | 5,500 ₹5,500 | 5,000 ₹5,000 | 4,000 ₹4,000 | 4,000 ₹4,000 | 5,000 ₹5,000 | 3,700 ₹3,700 | 6,500 ₹6,500 | 4,000 ₹4,000 |
Tender Value
Refer Docs
EMD Value
₹23,240
Closing Date
4 Feb 2026, 2:00 pmClosed
Executive Engineer JPDCL ED-I Parade Jammu
Office of Executive Engineer JPDCL ED-I Parade
SETC for Creation of 250 KVA Sub-Station alongwith Installation of 1 No 11 KV CT/PT for Electrification of Auditorium and Common room for Boys and Girls including parking stores, lift and ramp etc at CD Hospital Bakshi Nagar Jammu on turnkey basis
2026_PDD_300730_1
ED-I/e-NIT/64 of 2025-26 dated 15.01.2026
Open Tender
Electrical Works
Turn-key
30 days
Parade Jammu
Please refer tender documents
11 documents required · 11 mandatory
₹1,000
Executive Engineer JPDCL ED-I Parade Jammu
₹23,240
11 Feb 2026
15 Jan 2026
5 Feb 2026
15 Jan 2026
4 Feb 2026
15 Jan 2026
Supply, Erection, Testing & Commissioning for Creation of 250 KVA Sub-Station for Electrification of Auditorium and Common room for Boys & Girls including parking stores, lift & ramp etc. at CD Hospital Bakshi Nagar, Jammu
Complete materials for Sub-Station 250 KVA, 11/0.433, 3- Phase Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2 (Copper Wound) substation.
ST Poles 9 Mtr. Long
185mmsq(2ckt)cable,1.1kv Grade, PVC insulated standard conductor FRLS type
ACSR Rabbit Conductor
11 KV Disc insulator with fittings
11 KV Pin insulator with fittings
GI Channel/Angle/Flat of Size including Clamps
11 KV LA (Stn. type)
11 KV HG Set
Nuts & Bolts
Earthing of Substation complete
3Phase 4 wire Trivector meter
Red Oxide Paint
Cement Bottoming of Poles
Supply, Erection, Testing & Commissioning for Installation of 1 No. 11 KV CT/PT for 250 KVA sub stations at CD Hospital Bakshi Nagar, Jammu
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
sbd64.pdf
Tender Documents • 1.18 MB
BOQ_975457.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .