Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹41.6 L+₹2.7 L (7.01%)Rejected-Finance NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance Not being L1 bidder | |
| 3 | L3₹43.0 L+₹4.1 L (10.4%)Rejected-Finance | L3 | Rejected-Finance Not being L1 bidder | |
| 4 | L4₹45.1 L+₹6.2 L (16.0%)Rejected-Finance JAIN SADAN MAHAL ROAD SHIVPURI DISTT SHIVPURI MP | SHIVPURI | SHIVPURI | MADHYA PRADESH | L4 | Rejected-Finance Not being L1 bidder |
Tender Value
₹47.9 L
EMD Value
₹95,800
Closing Date
20 Nov 2023, 6:00 pmClosed
GARRISON ENGINEER SOUTH UDHAMPUR
GE SOUTH UDHAMPUR
PROVN OF ALUMINUM DOORS WINDOWS TILING REWIRING MISC WORK IN BLDG NO P 101 AND RE CONSTRUCTION OF COMPOUND WALL NEAR BLDG NO P 04 UNDER GE SOUTH UDHAMPUR
2023_MES_624698_1
GE/S(U)- /2023-24
Open Tender
Civil Works
Works
240 days
GE SOUTH UDHAMPUR
As per NIT
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹95,800
5 Jan 2024
23 Oct 2023
21 Nov 2023
23 Oct 2023
20 Nov 2023
6 Nov 2023
Amount
Demolition of cement concrete in ground floor and paving n exc 15 cm thickness below and above ground level complete all as specified and as directed.
Demolition of reinforced cement work as in roof slabs (other than ground floors) beams staircases , landing chajjas, drop facia and similar suspended work complete all as specified and as directed.
Anti-termite treatment of bottom and sides of excavation at the rate of 5 ltr of emulsion per square metre of surface area complete all as specified and as directed.
Fromwork to soffits of suspended slabs such as roof slabs, landing and similar work not exc 200mm thick complete all as specified and as directed.
Reinforced cement conc M-25 nominal mix as in slab supported on walls , beam, and columns in floors,roofs landings, balconies etc complete all as specified and as directed.
TMT steel bars 10mm dia and over cut to length bent to shape reqd incl cranking bending spirally for hooping for columns hooking ends and binding with m.s wire annealed not less than 0.9mm dia. (Note : Site for brick work may involve head load , contractor shallhave no claim on extra labour incurred in this account) complete all as specified and as directed.
Taking down cement plaster and raking out joints, hacking for key,scrubbing down with water built in cement mortar any description complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 Square Metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt ), complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and as directed.
Brick work with sub class "B" bricks straight or curved on plan exceeding 6 Metre mean radius in cement mortar 1:4 complete all as specified and as directed.
Rendering 15 mm thick in CM 1:6 on brick work and finished even and smooth without using extra cement complete all as specified and as directed.
15 mm thick rendering in two layers (10mm + 5mm) on fair faces of brick/concrete or stone surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete with water proofing compound (WPC shall be measured separtely) complete all as specified and as directed.
Rendering 10 mm thick in CM 1:3 on ceiling and exposed surface of concrete finsihed even and smooth without using extra cement complete all as specified and as directed.
New plaster surface of walls surface and applying two coat of plastic emulsion paint (Shed approved by GE) over two coat of wall care putty with primer complete all as specified and as directed.
Preparation of new plaster surfaces of wall and applying two coats of weather proof exterior emulsion paint (APEX or equivalent) over a two coat of wall care putty with coat of primer etc complete all as specified and as directed.
Preparing new ceiling surface and apply two coat of oil bound distemper over a coat of wall care putty with one coat of primer complete all as specified and as directed.
Complete removal of existing treatment of wall surface and applying two coat of plastic emulsion paint (Shed approved by GE) over two coat of wall care putty complete all as specified and as directed.
Complete removal of existing treatment (using removal machine) including preparing surfaces of wall and applying two coats of weather proof exterior emulsion paint (APEX or equivalent) over a two coat of wall care putty with a coat of Primer up to G+1 floor height etc complete all as specified and as directed.
Complete removal of existing treatment of wall two coat of wall care putty and applying two coats of oil bound distemper over a coat primers with complete all as specified and as directed.
All as pe Item No 19 above but on ceiling complete all as specified and as directed.
75 mm thick PCC 1:4:8 type D2 using 40mm graded aggregate as in sub base of floor etc complete all as specified and as directed.
15 mm thick screed bed in cement mortar 1:6 for laying floor finishes under floor complete all as specified and as directed.
Marble tile 20 mm thick machine cut, marble slab, (makrana black /green), as in flooring, bedded jointed with grey cement slurry and pointed with white cement including cutting and polishing complete all as specified and as directed.
Marble tile 20 mm thick machine cut, marble slab, as in flooring, bedded jointed with grey cement slurry and pointed with white cement including cutting and polishing with matte finish complete all as specified and as directed.
Cement concrete 1:3:6 type C-2, 75 mm thick using 20mm graded crushed stone aggregates as in plinth protection finished fair and even with using extra cement complete all as specified and as directed.
First class hard wood plain solid straight chowkats and frames and Design main doors Pannel shutter with wrought frmed on the solid rounded or chanbered put together with glue and pinned at joints including preservative treatment complete all as specified and as directed.
Supply and fixing 40 mm thick flush shutter (Both side decorative) solid core consturction with particle board core and plywood face panels on both side and both face is covered with decorative face veneer with lipping/frame to match complete all as specified and as directed.
Supply and fixing Solid (wood grain printed) PVC door frame of size 50 mm x 47 mm made of 5 mm wood grain printed PVC sheet reinforced with mild steel square tube and t & edges will be painted to match with printed shee complete all as specified in clause 8B.3.1 and as per drawing shown in SSR Part-II (2020) complete all as specified and as directed.
Supply and fix Factory made wood grain printed , solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded wood grain printed PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling ofwood grain printed PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails ,5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900 ) used instead of exposed portion of PVC sheet and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2010) complete all as specified and as directed.
150 mm brass barrel tower bolts,with cast or sheet and rolled or cast bolts complete all as specified and as directed.
Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts 300 mm complete all as specified and as directed.
125 But hinges, extruded brass, with mild steel hinge pin, bright polished and fixed, type C-12 complete all as specified and as directed.
150 mm length Brass handles, cast type, polished bright Extruded brass handles, fabricated type polished complete all as specified and as directed.
French polishing on surfaces of any description width or girth including cleaning and prepairing the surface including a coat of wood filler on new works with two or more coats complete all as specified and as directed.
Preparing new/old wooden surface & applying two coats of synthetic ennamel paint over a coat of pink primer over 10cm width or girth complete all as specified and as directed.
18/19mm thick plywood, grade 1 (with BWR resistance/termite proof) with screws to timber frame work as in cup boards/cabinets etc complete all as specified and as directed.
12mm thick plywood, grade 1 (with BWR resistance/termite proof) with screws to timber frame work as in cup boards/cabinets etc complete all as specified and as directed.
0.9mm thick decorative choice of lamination type-1 of surface finish white stuck with imported adhesive on sides of board complete all as specified and as directed.
Description all as per Srl item No 38 above but designer type with matic finish 1.5mm thick complete all as specified and as directed.
6.4 mm thick bevelled edge glass of area n exc 0.5 Sqm each as in shelves of size and shape as required at site complete all as specified and as directed.
Stainless steel clamps capable of supporting glass shelves of max width 100 mm complete all as specified and directed
Continuous (piano) hinges, mild steel, bright finish or elecrogalvanised width of flaps when open in 30mm and fixed complete all as specified and as directed.
100mm long extruded brass handle olished bright complete all as specified and as directed.
Designer brass barrel tower bolts of size 100mm (ISI Marked) including screws and fixed complete all as specified and as directed.
Brass mortice lock 30mm long for 4 leaver cup boards complete all as specified and as directed.
Brass hasp and staple size 100mm powder coated with hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed.
Brass 40 mm dia, cupboard knob fixed with nut, screw and washer of mild steel, brass polished bright bright finished complete all as specified and as directed.
Roughening surfaces of concrete floor by picking sweeping cleaning & washingg down with water to remove dust etc incl removal of Old/New treatment of any description and applying one coat of neat cement slurry @ 3.00 kg/Sqm complete all as specified and as directed.
PCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate as in level course on roof surface 25mm thick etc complete all as specified and as directed.
Rendering 10 mm thick in CM 1:3 mixed with integral water proofing compound as per manufacture's instructions as in roof and chajjas, and drop facia finished the surface fair and even with out using extra cement.(Note : Supply of water proofing compound will be measured and paid separately) complete all as specified and as directed.
Applying bituminous primer on roof surfaces @ 0.40 ltr/sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 kg/sqm and provide modified polymeric five layered APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polythylene film. Min wt of memebrane will be 3.5 kg/sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm blinded with fine sand in dry condition @ 0.5 kg/sqm including two coats of bituminious alluminium paint complete all as specified and as directed.
Supply only integral water proofing compound complete all as specified and as directed.
PCC 1:2:4 using B-0 (12.50 graded crushed stone aggregate) for coping, corner of roof and similar work complete all as specified and as directed.
110 mm PVC (SWR) pipes single socket in any length with rubber ring joints fixed to wall complete all as specified and as directed.
110 mm PVC (SWR) bends any redius with access door complete all as specified and as directed.
Material and labour ultracharged/double charged Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
Material and labour ultracharged/double charged Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 Sqm, in skirting / dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
110 mm PVC (SWR) couplers for pvc pipe and similar work complete all as specified and as directed.
Aluminum door closer (aluminum extruded section) hydraullically regulated , designation No 3 , universal type , suitable for door shutters of 851mm to 1000 in width and of weight 61 to 80 kg complete all as specified and as directed.
Hharrison, rails drapery rod powdered coated including brackets and necessary fitting complete all as specified and as directed.
Non skid coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11Sqm but not exc 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing complete all as specified and as directed.
Rendering 10mm thick on fair faces of brick work or concrete surface in CM 1:4 on vertical surfaces/backing coat complete all as specified and as directed.
Glazed ceramic coloured tiles of size 300x600x7mm wall tiles set and jointed in neat cement and in white/coloured cement to match with the colour of tile etc, complete all as specified and as directed.
S&F in repairs water closet wall mounted pattern pattern colour (as approved by Engineer-in-charge) Make SOMANY CAT PART No (EWC 120305) cistern 120714 Seat cover 121311 Twin flush cistern 120627) UNIEK complete all as specified and as directed.
WHB coloured 615mmx510mm with pedestal Make CERA CARNIVAL Cat No (WHB 1009, PEDESTAL 1108) complete all as specified and as directed.
CP waste coupling 32mm dia PTMT (half or full threaded ) minm wt 450 gms complete all as specified and as directed.
PVC waste pipe 32mm bore with cup and washers complete all as specified and as directed.
15mm bore centre hole basin mixer with round spout with 450mm long copper pipes and brass nuts with out Pop up complete all as specified and as directed.
15mm bore Bib tap complete all as specified and as directed.
15mm bore angular stop cock with wall flange complete all as specified and as directed.
PVC connection 15mm bore 450 mm long Braided Hose with M10X1 Nipple, 15 mm Nut, O-Ring & Rubber washer (Suitable for Basin Mixers) complete all as specified and as directed.
PVC connection 15mm bore 450 mm long Braided Hose with two 15 mm Nut, & Rubber washer without nipple complete all as specified and as directed.
Chromium plated toilet paper holder complete all as specified and as directed.
Glass shelf with chromium plated guard rails complete all as specified and as directed.
600 mm long brass chromium plated towel rail fancey type complete all as specified and as directed.
Soap dish complete all as specified and as directed.
Double Coat hook complete all as specified and as directed.
Powder coated Aluminium frames for doors, windows, ventilators with one or more rebates annd aluminium window and ventilator shuttter frames jointing cleats for fixing and partation wall frame etc complete all as specified and directed thickness of powder coating not less than 50 micron complete all as specified and as directed. Note : Powder coated aluminium coating colour is approved by GE.
Aluminium anodised double shutter ventilator (glazed and wire gauge) top hung with aluminium ventilator frame or chowkat 1.5 mm thick aluminium anodised of size 100 mm x 44.5 mm and ventilator shutter frames glazed and wire gauze 1.5 mm thick aluminum anodised of size 44.5x44.5 mm incl aluminium grill ,Stainless steel wire Mesh and all fitting such as rubber gasket aluminium glazing clips and including 5.5 mm thick tinted glass pane in glazed shutter fixed with rubber gasket and glazing clip/aluiminium beads aluminium tower bolt 75mm 02 Nos in each shutter , aluminium butt hinges 50 mm 02 Nos in each shutter aluminium handle 75 mm 01 No in each shutter incl all accessories complete all as specified and as directed.
Powder coated Aluminium anodised three track shutter window (glazed and wire gauge) sliding with aluminium window frame or chowkat 1.5 mm thick aluminium anodised of size 100 mm x 44.5 mm and window shutter frames glazed and wire gauze (middle, toprail, bottom rail) and styles 1.5 mm thick aluminum anodised of size 44.5x44.5 mm incl aluminium grill,stinless steel wire mesh and all fitting such as rubber gasket aluminium glazing clips locking cabinet and 75 mm handle and including 5.5 mm thick frousted glass pane in panes fixed with rubber gasket and glazing clip/aluiminium beads aluminium tower bolt 75 mm 02 Nos , aluminium butt hinges 75 mm 02 Nos in each shutter aluminium handle 100 mm 01 No in each shutter including all accessories complete all as specified and as directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed.
Solid PVC wall lining / pannling consisting 5-8mm thick prelam colour PVC sheet incusive of solvent cement and fixing at site of PVC frame complete all as specified and as directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Earth work in excavation in any type of soil by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m complete all as specified and as directed.
PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
All as per item No 10 but except bricks complete all as specified and as directed.
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work finished even and fair without using extra cement complete all as specified and as directed.
Material and labour for providing precast cement concrete louvers and jallies, 50mm thick (measured solid) including all mouldings set in cement mortar 1:6 type B0 1:2:4 (Using 12.5 mm graded stone aggregate) complete all as specified and as directed.
RCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in coping, benching including weathering slightly rounded or chamfered angles as directed including necessary form work and finishing the exposed surfaces complete all as specified and as directed.
Use and waste of fair finished flat formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, RCC band, coping etc. also splays between floors and beams, etc complete all as specified and as directed.
Mild steel TMT bars 6 to 8 mm dia, cut to length bent to shape required including cranking bending spirally for hooping ends and binding with and incl mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and as directed.
PVC pipe 110 mm dia low density of pressure rating 10 kg/sqcm (in short lengths) fixed in walls as weep holes as in retaining wall complete all as specified and as directed.
Preparation of new plastered surfaces of wall and applying two coats of cement based paint including over a coat of chalk whiting primer complete all as specified and as directed.
Complete removal of existing treatment on wall, preparation of old surfaces of wall and applying two coats of cement based paint including over a coat of chalk whiting primer complete all as specified and as directed.
Returing, filling in, including spreading, levelling, water and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated material n exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete including fitting such as switch, sockets, ceiling rose, pendants socket,fan regulators any type, rectangular board ,light fittings,terminal boxes etc removing materials for taking credit and making good disturbed surfaces of walls floors and ceiling complete all as specified and as directed.
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and as directed.
Taking down Old/ Unserviceable MCB DBs TPN / Main Switches by disconnection of electric connection including old unsv MCCBs,MCBs, isolators etc and making good to distrubed surface complete all as specified and as directed.
Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit as per site requirement (thickness not less than 1.5mm and 20mm dia), medium grade with Modular sunken boxes & PVC back plate for mounting modular type switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly as specified.Note:- Cutting and making same the wall patchs after laying the wire and conduit using putty, white wash and distamper. The surface should be made smooth using putty and should match exactly with the existing wall finish complete all as specified and as directed.
All as per Item No 104 but for one light point control by two no two way switches with other Independent Board with 1.5 sqmm PVC insulated unsheathed FRLS copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed FRLS copper conductor single core cable (green color) as earth lead or & as directed by Engg- in- charge to match with the existing specification complete all as specified and as directed.
All as per srl item No 104 but for 3 pin 6 Amps socket outlet independent board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and as directed.
All as per srl item No 104 but for 3 pin 6 Amps socket outlet on the same board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and as directed.
All as per Srl item No 104 but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire standard and connected to earth dolly complete all as specified and as directed.
S&F for modular switch 6 Amps single pole one way 230 V, 50 Hz, AC , with outer strip complete all as specified and as directed.
S&F for modular switch 6 Amps single pole two way 230 V, 50 Hz, AC , with outer strip complete all as specified and as directed.
S&F for modular switch 16 Amps single pole one way 230 V, 50 Hz, AC , with outer strip complete all as specified and as directed.
S & F modular Bell push flush type 6 amp 230 V, 50 Hz, AC , with outer/inner cover complete all as specified and as directed.
S&F for modular socket 3 Pin 6 Amps flush type 230 V, 50 Hz, AC , with outer/inner cover complete all as specified and as directed.
S&F for modular socket combined 2-in-1, 6 Pin 6 & 16 Amps 230 V, 50 Hz, AC , flush type with outer/inner cover complete all as specified and as directed.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block complete all as specified and as directed.
S & F calling Bell ding dong 230 volts single pole 50Hz complete all as specified and as directed.
S & F in replacement sheet metal enclosures for DBs when MCBs to be used double door DB VTPN MCCB 125A 4way IP43 Protection Make: Cat Pt No - 811888 complete all as specified and as directed.
S&F Sheet metal enclosure double door type for DBs (when MCB to be used) 12 way 240 volts with 200 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
S & F in replacement MCCB Three Pole & Neutral capacity of 125 amps 415 volts rupturing capacity 16 KA complete all as specified and as directed.
S & F in replacement MCB Single pole and neutral 240 volt any rating from 40 amps"C" series, with rupturing capacity 10 KA, inculding providing thimble for out going cable complete all as specified and as directed.
S & F in replacement MCB single pole 240 volt any rating from 10 to 40 amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and as directed.
S & F in replacement MCB single pole and neutral 240 volt any rating from 63 Amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 6 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 6 Sq mm as earth lead including taking down old sub main wire (For TPN DB to SPN DB) complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 4 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 2.5 Sq mm as earth lead including taking down old sub main wire (for AC) complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 2.5 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 1.5 Sq mm as earth lead including taking down old sub main wire(For street light) complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x6.3 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized steel earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC 1:2:4 type B-1using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore main board complete all as shown in electrical plate No 5 connected to main control board all as specified and testing on completion. Note: Excavation earthwork charcoal PCC pit is covered under this item including taking out existing earth plate etc.Note: if earth resistance of earthing is not found (2 to 5 Ω) satisfactory if will be redone by the contractor on his risk and cost.
S&F electronic step type fan regulator 120 watt 230 volts 50Hz two module C/S deluxe type complete all as specified and as directed.
Taking down ceiling fan/Exhaust fans (C/F of any size/make), cleaning its dust particles oiling,greasing,one coat of synthetic enamel white spray painting with blade ,reassemble the same along with all fittings and hanging the same back to its original position including connecting the wire to ceiling rose etc complete after completing the wiring complete all as specified and as directed. Note :- (i) The spares like condensor, ball bearing, cotter pin, nuts & bolts, connecting rods & hooks etc if found defective/damage deemed to be replaced and make the ceiling fans functional. No extra payments will be done on this account.
Supply and fixing LED lights fitting 1x 20W, 230V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitablesize complete all as specified and as directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 1 feet, 05 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
LED Panel light 2'x2' capacity 36 Watt extruded aluminium housing with milky diffuser recess mounting ultra modern desinged architectural LED luminaire which provides soft-light and glare free symmetrical illumination suitable for Armstron/Grid ceiling including driver 36 Watt capacity complete making all connection with suitable size flexible cable from ceiling rose to fitting including taking down old one complete all as specified and as directed.
LED Panel light 2'x2' capacity 36 Watt, extruded aluminium housing with milky diffuser surface mounting ultra modern desinged architectural LED luminaire which provides soft-light and glare free symmetrical illumination including driver 36 Watt Capacity complete making all connection with suitable size flexible cable from ceiling rose to fitting including taking down old one complete all as specified and as directed.
Venza decorative wall mounting light fitting, SS finish fixture with opal glass diffuser including 12W retrofit LED bulb and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed.
Supply and fixing LED building security light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp,clamps,suitable bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
S&F Street light Bracket complete made of GI pipe of suitable size, medium grade 1.2 m long bent to shape as per site requirement along with MS flat iron clamps with nuts, bolts, washers including grouting the same with wall, complete all as specified and as directed.
Material & Laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with "XLPE" insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 25 Sqmm x 3.5 core size all as specified including taking down old cable complete all as specified and as directed. Note : Earth work and other connected work shall be measured & paid sperately.
Excavation in trenches and exceeding 1.5m wide and not exc 1.5m in depth in hard/dense soil and getting out complete all as specified and as directed.
Returing, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
Dry sand for sand cushioning to under ground cable 8 cms thick before laying the cable before and 15 cms thick after laying & streching the cable in trenches, including hand punning and consolidating complete all as specified and as directed. Note : for payment purpose punned thickness shall be measured
M&L Bricks sub class 'B' brick laid dry, flat with width equal to length of brick as cover laid over the cabel to give mechanical protection to underground cabels complete all as specified and as directed.
Supply and fixing GI tubing light grade 40 mm dia along the wall/ in trenches/ in duct / in culvert /road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holdining of GI pipe alongwith poles complete all as specified and as directed.
SINGH CONST CO
khajuria builders
anil construction co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .