Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-Finance | L1 | Accepted-Finance Lowest among the valid bidders | |
| 2 | L2₹8.2 L+₹2.2 L (37.0%)Accepted-Finance | L2 | Accepted-Finance L2 Bidder | |
| 3 | L3₹9.4 L+₹3.4 L (56.0%)Accepted-Finance CHENNAI | CHENNAI | TAMIL NADU | 600001 | L3 | Accepted-Finance Highest among the valid bidders | |
| 4 | Rejected-Technical | - | Rejected-Technical Evaluation Rejected |
Tender Value
₹9.9 L
EMD Value
₹10,000
Closing Date
12 Nov 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
O/o Executive Engineer,WRD., Bhavanisagar Dam Division, Bhavanisagar
Special Repairs to Spillway shutter No.7,8 and 9 in Masonry Portion of LBP Dam at Bhavanisagar
2026_WRD_718574_1
NIT No.5/2026-27/dt.26.10.2026
Open Tender
Civil Works
Lump-sum
Bhavanisagar
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹10,000
23 Nov 2026
28 Oct 2026
13 Nov 2026
28 Oct 2026
12 Nov 2026
28 Oct 2026
90 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Application of coaltar epoxy over the primer shall be through airless spray method. The colour shall be black and the mixing ratio of base to accelerator should be by manufacturer standards. The dry film thickness should be between 125-150 µ per coat. The interval before over coating shall be 24 hours. All paint, when applied, shall provide a satisfactory film and a smooth and even surface. Paint shall be thoroughly stirred, strained, and kept at the uniform consistency during application. Paint shall not be applied when the temperature of the metal or surrounding air is below 10 degree Celsius and that of the metal is above 50 degrees Celsius, or when the humidity is above 90 percent, or when it threatens to rain before the painted coat gets dry. Each coat shall be protected during the initial curing period against the possibility of moisture condensation or contamination with foreign matter. All painting works shall be performed by airless spraying. When the coating material is applied by spraying, suitable means shall be provided to prevent segregation during the coating operation. Free oil and moisture shall be removed from the air supply lines of all spraying equipment. Each coat shall be uniform and free from runs, sags and other imperfections. The time between successive coats shall be not less than the minimum nor more than the maximum re-coating time specified by the paint manufacturer. The paint shall be applied so that the thickness at any point is not less than that stipulated in the approved painting specifications. Surface not required to be coated, but adjacent to surfaces which are to be cleaned and coated, shall be adequately protected during cleaning and coating. | 495 | Square Metre | 1,020 | ₹5,04,900 |
| 2 | Fabrication, supply, transportation, installation, testing and commissioning of LED Sign Board using EV LED 3-Dot, 12V, 2-Watt High Power LED modules complete with NC (Korea) 12V, 40 Amps power supply, including all necessary wiring, connectors and accessories. The sign board shall be fabricated as per the approved design with 3 mm thick acrylic letters having 2.5-inch deep aluminium trim caps, 3 mm thick ACP (Viva Brand or equivalent approved make) background, and 3.0' × 1.5" MS rectangular pipe framework complete with primer and protective paint. The work shall include the fabrication and fixing of 140 Sq.ft of LED letters, 408 Sq.ft of ACP cladding (50 ft × 7 ft), complete MS fabrication and erection, transportation of all materials to site, back-side ACP closing of 350 Sq.ft (50 ft × 7 ft), and all labour, scaffolding, tools and tackles required for complete installation. The work shall be executed using approved quality materials and good workmanship, ensuring proper alignment, structural stability, weather resistance, electrical safety, and satisfactory performance, complete in all respects as directed by the Engineer-in-Charge. | 1 | Job | 3,30,000 | ₹3,30,000 |
| 3 | GST 18% | 1 | Rs | 1 | ₹1 |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
finance_863002.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.90 MB
tenderdoucument5_5.pdf
Tender Documents • 0.72 MB
BOQ_863002.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .