Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹28.0 LRejected-Finance HARIAU TEHSIL LEHRA DISTRICT SANGRUR PUNJAB | 1 | Rejected-Finance Rejected due to Single bid |
Tender Value
₹26.7 L
EMD Value
₹53,460
Closing Date
31 Dec 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Ranbir Club Sangrur
PROVIDING IMPROVED ACCESS TO WATER THROUGH HOUSEHOLD CONNECTIONS IN EXISTING SCHEME
2021_WSS_79062_1
WSSD/2021-22/73
Open Tender
Civil Works
Item Rate
90 days
Sangrur
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹53,460
11 Feb 2022
13 Dec 2021
31 Dec 2021
13 Dec 2021
31 Dec 2021
13 Dec 2021
90 days
Amount
Component -1
Replacement of machinery
Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set of reputed Make capable of delivering 245 LPM against a head of 84 mtr 10 BHP including M.S. Column Pipe of suitable size 100 mm=50 mtr in 3 mtr lengths each with flanges, screwed and welded on both sides 10.00 m2 Cable 100mtr without Panel Board rubber gaskets, nuts and bolts submersible cable 4mm2 = 100mtr. (reputed make) complete in all respects as per standard Specifications.
Moter with Pump
Column pipe 80 mm i/d
Submersible Cable 4 mm2
Credit of old Machinery only Sub-set
REPLACEMENT OF CONTROL PANEL BOARD
Providing & Fixing Electric Panel Board (ISI marked) Consisting of electric appliances such as Automatic star Delta Push Button with oil immersed starter, Main switch, VM ampere Meter, E LCB, shunt capacitor, single phase Preconter, including lamps, Kit-kat etc. Complete in all respect.
Repair of OHSR
Repair of Expansion Joint.
Size 80 mm i/d
Size 100 mm i/d
P/F OHSR Jali
CI Cover of OHSR
Painting of OHSR pipes including cost of labour & material complete in all respects.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in - charge)
Repair of plinth protection around OHSR (Analysis Attached) complete in all respects.
OHSR-25000 ltr Capacity outer dia of toe wall 5.55 m
Repair of Water Works
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 & 8 (as per Analysis A-8)
Cement concrete 1:8:16 with 40 mm gauge stone aggregate to be used instead of brick ballast & Conglomerate floor 40mm cement concrete topping 1:2:4 Foot Path as per Analysis attached
Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects as per standard Drawing D-8 & (as per Analysis A-6).
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-8 & Analysis A-9-A
Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3 & Analysis A-5.
Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing with including D-4 & Analysis A-6 complete in all respects
Construction of 225mm thick brick masonry toe wall in 1:5 cement sand mortar with depth 0.60 mtr ,C.C. 1:8:16 & 12.5 mm thick cement plaster in 1:4 on both sides and top of toe wall complete in all respects as per analysis A-18 (including cost of Carriage)
RISING MAIN (Tubewell to OHSR & bye pass)
Providing, Laying, fixing & jointing of P.V.C pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specificationa.110 mm o/d 10 kg cm2 pipe
Chlorinator
Providing, Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering Syatem, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching powder solution/ Sodium Hypo Solution per hour under maximum delivery pressurSe upto 7 kg.cm 2 and suction lift not less than 1.5 m, as per DWSS standard specifications.
Repair and minor Replacement
Provision for repair of leakage, PVC pipe, PVC Coupler, Baling Out, Excavation, Labour including all material. Complete in all respect.
Automated Water Controller
Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects.
Component -2
Providing proposed water connection to house hold up to wall with providing, laying jointing, testing MDPE pipe lines 15mm i/d=2.000 mtr & 2.50 mtr G.I Pipe, including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3'' i/d clamp with c.i. bib cock 15mm i/d as per IS:210 with stainless steel spindle of approvel make as per CSR 30.65 (b) Including cost of dismantling brick paving /CC flooring & relaying the same original condition in complete respect
Component -3
Providing, Laying, fixing & jointing of PVC Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing including excavation & back filling complete as per specifications for more than 3 mtr street width included excavation.
PVC pipe 90mm o/d 6Kg/sqcm
PVC pipe 63mm o/d 6Kg/sqcm
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in - charge)
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department 2No. With each of Size 0.60m x 0.60m
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
PVC pipe 90 mm o/d
Dismantling of cement concrete 80mm thick cement concrete 1:2:4 over 100mm thick C.C. 1:8:16 and making good the same to its original condition complete in all respects as per analysis A-25
PVC pipe 90 mm o/d
Providing proposed water connection to house hold up to wall with providing, laying jointing, testing MDPE pipe lines 15mm i/d=2.000 mtr & 2.50 mtr G.I Pipe, including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3'' i/d clamp with c.i. bib cock 15mm i/d as per IS:210 with stainless steel spindle of approvel make as per CSR 30.65 (b) Including cost of dismantling brick paving /CC flooring & relaying the same original condition in complete respect
Providing & fixing MS Sign Board as per standard size of DWSS as per analysis A-24 & Drawing D-20
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .