Loading…
Loading…
Tender Value
₹1.8 Cr
EMD Value
₹1.8 L
Closing Date
28 Aug 2026, 3:00 pm4d left
The Commissioner
New Colony 3rd Main Road, Chrompet
TCMC - Supply and laying of Water Supply Pumping Main line along Pallavaram-Thoraipakkam 200ft Radial Road towards Pallavaram from Echangadu Signel to Skypark Residences in Ward No.20,21 and 24 in Zone II Tambaram City Municipal Corporation
2026_DMA_693808_2
43/2026/E1 - Z2
Open Tender
Pipe Laying Works
Works
90 days
TCMC ZONE - 2
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
₹1.8 L
TCMC Zone II Office
13 Aug 2026
13 Aug 2026
28 Aug 2026
13 Aug 2026
28 Aug 2026
13 Aug 2026
20 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | GST % |
|---|---|---|---|---|---|---|
| 1 | Supply and Delivery of Ductile Iron Socket/Spigot Pipe for class K7 AS per IS8329/2000 Unloading, stacking at stock yard and Cost of loading from Stockyard and unloading at site,Conveyance from stock yard to site
200mm Dia | 4,500 | Rm | - | - | 18% |
| 2 | Earthwork excavation for loose soil SS-20B and ordinary soil SS-20B And Refilling For Pipe Line Works having Bed Width Of 1.25M And Below On Linear Measurement Basis Conveyance from stock yard to site etc. complete complying with standard specification and as directed by the departmental officers
200mm Dia | 4,500 | Rm | - | - | 18% |
| 3 | Supplying and filling in foundation, basement, etc with conveyed earth in layers of not more than 150mm thick layers well watered, rammed with surface vibrator and consolidated including conveyance charges etc. complete complying with standard specification and as directed by the departmental officers.
200mm DIa | 270 | Cum | - | - | 18% |
| 4 | Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the TWAD Officers.
For depth upto 2m
200mm Dia | 4,500 | Rm | - | - | 18% |
| 5 | Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in units of (kilolitres/ cubicmeter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3m/sec to 4 m/sec and be constructed as follows:Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be weldedto the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects Coil Housing shall be fabricated from stainless steel (SS 304) with Anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP 68 protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output, . | 1 | Nos | - | - | 18% |
| 6 | Supply and Delivery of Ductile Iron Specials fpr class K7 AS per IS9523/2000 Unloading, stacking at stock yard and Cost of loading from Stockyard and unloading at site,Conveyance from stock yard to site
100mm - 200 mm dia | 500 | Kg | - | - | 18% |
| 7 | Supply and Delivery of Ductile Iron Socket/Spigot Pipe fpr class K7 AS per IS8329/2000 Unloading, stacking at stock yard and Cost of loading from Stockyard and unloading at site,Conveyance from stock yard to site
100mm Dia | 200 | Rm | - | - | 18% |
| 8 | Earthwork excavation for loose soil SS-20B and ordinary soil SS-20B And Refilling For Pipe Line Works having Bed Width Of 1.25M And Below On Linear Measurement Basis Conveyance from stock yard to site etc. complete complying with standard specification and as directed by the departmental officers
200mm Dia | 200 | Rm | - | - | 18% |
| 9 | Supplying and filling in foundation, basement, etc with conveyed earth in layers of not more than 150mm thick layers well watered, rammed with surface vibrator and consolidated including conveyance charges etc. complete complying with standard specification and as directed by the departmental officers.
200mm DIa | 200 | Cum | - | - | 18% |
| 10 | Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the TWAD Officers.
For depth upto 2m
200mm Dia | 200 | Rm | - | - | 18% |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
BOQ_834164.xls
BOQ • 0.43 MB
TD2.pdf
Tender Documents • 1.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].