| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 CrAccepted-AOC | ₹5.3 Cr | L1 | Accepted-AOC Accepted being lowest |
| 2 | L2₹5.4 Cr+₹10.0 L (1.87%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹5.4 Cr+₹10.0 L (1.87%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹5.5 Cr+₹15.1 L (2.84%)Rejected-Finance | ₹5.5 Cr+₹15.1 L (2.84%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹5.6 Cr+₹27.6 L (5.18%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹5.6 Cr+₹27.6 L (5.18%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹5.7 Cr+₹39.2 L (7.36%)Rejected-Finance | ₹5.7 Cr+₹39.2 L (7.36%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹6.7 Cr
EMD Value
₹6.6 L
Closing Date
14 Sept 2022, 6:00 pmClosed
Chief Enngineer Pathankot Zone
HQ Chief Engineer Pathankot Zone, Pathankot
ADDITION ALTERATION OF ELECTRIC SUPPLY AT RATNUCHAK MIL STN
2022_MES_545566_1
CEPZ-18/2022-23
Open Tender
Civil Works
Lump-sum
456 days
GE Kaluchak
All as per Tender Documents
7 documents required · 7 mandatory
₹3,000
GE Kaluchak
₹6.6 L
Yes
7 Nov 2022
16 Aug 2022
21 Sept 2022
16 Aug 2022
14 Sept 2022
7 Sept 2022
Amount
Lumpsum price worked out by the contractor for Building work as listed in Schedule 'A' Part-I.
Lumpsum price worked out by the contractor for Internal Water Supply as listed in Schedule 'A' Part-II.
Lumpsum price worked out by the contractor for Plumbing Works as listed in Schedule 'A' Part-III.
Lumpsum price worked out by the contractor for Internal Electric Supply as listed in Schedule 'A' Part-IV.
Lumpsum price worked out by the contractor for Road Path and Hardstanding as listed in Schedule 'A' Part-V.
Lumpsum price worked out by the contractor for Sewage Disposal as listed in Schedule 'A' Part-VI.
Lumpsum price worked out by the contractor for Area Drainage as listed in Schedule 'A' Part-VII.
Lumpsum price worked out by the contractor for Security wall and fencing as listed in Schedule 'A' Part-VIII.
Lumpsum price worked out by the contractor for External Electrification as listed in Schedule 'A' Part-IX.
Lumpsum price worked out by the contractor for Demolition/Dismantling as listed in Schedule 'A' Part-X.
EXTERNAL ELECTRIC SUPPLY :
Supply installing, testing and commissioning LT Feeder Pillar / Panel board cubical type outdoor Confirming to IS 8623 Part 1 1993, free floor standing factory fabricated made out of 3.15 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming ACB, Outgoing MCCB, MCB . The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator . The incoming as well as outgoing MCCBs shall have copper extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour sleeves. A detachable predrilled gland plateof thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with cable glands
The above panel shall be front and back lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air, weather, dust and vermin proof with IP65 degree of protection.Base frame of the panel shall be made of angle iron of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:4), 15mm thick plastering in CM (1:6) having minimum height of 600 mm, complete as specified and consisting of the following switchgears and accessories: (KR VIHAR EAST POCKET A Main Panel) (a) Bus bar electrolytic grade copper strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 1250 amps. (b) Main Incoming ACB four pole 415 V AC, current rating 800 amps, breaking cap 50 KA at 415 volts = 01 No (c) Outgoing MCCB four pole 415 V AC, current rating 400 amps, breaking cap 36 KA at 415 volts = 01 No (d) Outgoing MCCB four pole 415 V AC, current rating 320 amps,breaking cap 25 KA at 415 V AC = 01No (e) Outgoing MCCB four pole 415 V AC, current rating 250 amps, breaking capacity 36 KA at 415 volt =01 No
(f) Outgoing MCCB four pole 415 V AC, current rating 160 amps, breaking capacity 16 KA at 415 volt = 01 No (g) Outgoing MCCB four pole 415 V AC, current rating 125 amps, breaking capacity 16 KA at 415 volt -02 Nos (h) LED Multifunction meter flush panel mounting 96mm x 96 mm,having parameters such as V,A,F,PF,KW,KVA,KVAR,KWH,KVAR,neutral current,% Load,Max Demand(KW&KVA)-01 No (On incoming) (i) LED indicator (R,Y,B) of suitable capacity (j) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (k) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 1250/5 amps, 15 VA accuracy class - 3
All as per srl item No 12 above but comprising with the following accessories: -(KR VIHAR EAST POCKET A Feeder Piller-1) (a) Bus bar electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 400 amps. (b) Main Incoming MCCB four pole 415 V AC, current rating 250 amps, breaking cap 25 KA at 415 volts (c) Outgoing MCCB four pole 415 V AC, current rating 125 amps,breaking cap 16 KA at 415 V AC = 02 Nos Outgoing MCCB four pole 415 V AC, current rating 63 amps,breaking cap 16 KA at 415 V AC = 02 Nos (d) LED Multifunction meter flush panel mounting 96x96 mm,having parameters such as V,A,F,PF,KW,KVA,KVAR,KWH,KVAR,neutral currant (e) LED indicator (R,Y,B) of suitable capacity (f) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (g) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 400/5 amps, 15 VA accuracy class - 3 Set of three
All as per srl item No 12 above but comprising with the following accessories: -(KR VIHAR EAST POCKET A -P-66,P-54,P-52,POCKET B P-130,P-59 POCKET C P-12, WEST POCKET A FP-1, FP-2 (a) Bus bar electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 300 amps. (b) Main Incoming MCCB four pole 415 V AC, current rating 125 amps, breaking cap 16 KA at 415 volts = 01 No (c) Outgoing MCCB four pole 415 V AC, current rating 63 amps,breaking cap 16 KA at 415 V AC = 03Nos (d) LED Multifunction meter flush panel mounting 96x96 mm,having parameters such as V,A,F,PF,KW,KVA,KVAR,KWH,KVAR,neutral currant, (e) LED indicator (R,Y,B) of suitable capacity (f) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (g) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 300/5 amps, 15 VA accuracy class – 3 set of three
All as per srl item No 12 above but comprising with the following accessories: -EAST POCKET A FP-2 (a) Bus bar electrolytic grade copper strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 600 amps. (b) Main incoming MCCB four pole 415 V AC, current rating 400 amps, breaking cap 36 KA at 415 volts =01 Nos (c) Outgoing MCCB four pole 415 V AC, current rating 100 amps, breaking cap 16 KA at 415 V AC = 04 Nos (d) Outgoing MCCB four pole 415 V AC, current rating 125 amps, breaking capacity 16 KA at 415 volt = 01Nos (e) LED Multifunction meter flush panel mounting 96x96 mm,having parameters such as V,A,F,PF,KW,KVA,KVAR,KWH,KVAR,neutral currant, (f) LED indicator (R,Y,B) of suitable capacity (g) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (h) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 600/5 amps, 15 VA accuracy class - 3 set of three
All as per srl item No 12 above but comprising with the following accessories: -EAST POCKET A P-53,P-61,P-62,P-60,P-45,P-49,P-14,P-44,P-43, POCKET B P-63,64,128,129,239,240, 15,238,236,237,FP-6,POCKET C -P-18,P-17,P-16,P-46,P-12 WEST POCKET B FP-1, FP-3 (a) Bus bar electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 250 amps. (b) Main Incoming MCCB four pole 415 V AC, current rating 100 amps, breaking cap 16 KA at 415 volts = 01 No (c) Outgoing MCCB four pole 415 V AC, current rating 63 amps, breaking cap 16 KA at 415 V AC = 03 Nos (d) LED Multifunction meter flush panel mounting 96x96 mm,having parameters such as V,A,F,PF,KW,KVA, KVAR,KWH,KVAR,neutral current, (e) LED indicator (R,Y,B) of suitable capacity (f) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (g) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 250/5 amps, 15 VA accuracy class – 3 Set of three
All as per srl item No 12 above but comprising with the following accessories: -EAST POCKET A FP-5 (a) Bus bar electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 250 amps. (b) Main Incoming MCCB four pole 415 V AC, current rating 160 amps, breaking cap 25 KA at 415 volts = 01 Nos (c) Outgoing MCCB four pole 415 V AC, current rating 63 amps,breaking cap 16 KA at 415 V AC = 04Nos (d) LED Multifunction meter flush panel mounting 96x96 mm,having parameters such as V,A,F,PF,KW,KVA, KVAR,KWH,KVAR,neutral currant, (e) LED indicator (R,Y,B) of suitable capacity (f) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (g) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 250/5 amps, 15 VA accuracy class - 3 Set of three
All as per srl item No 12 above but comprising with the following accessories: -EAST POCKET A FP-3 (a) Bus bar electrolytic grade copper strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 600 amps. (b) Main Incoming MCCB four pole 415 V AC, current rating 320 amps, breaking cap 36 KA at 415 volts = 01 No (c) Outgoing MCCB four pole 415 V AC, current rating 100 amps, breaking cap 16 KA at 415 V AC = 04Nos (d) Outgoing MCCB four pole 415 V AC, current rating 63 amps, breaking cap 16 KA at 415 V AC = 01No (e) LED Multifunction meter flush panel mounting 96x96 mm, having parameters such as V,A,F,PF,KW,KVA,KVAR,KWH,KVAR,neutral currant,% Load,Max Demand(KW&KVA)-01 No (On incoming) (f) LED indicator (R,Y,B) of suitable capacity (g) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (h) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 600/5 amps, 15 VA accuracy class - 3 Set of three
All as per srl item No 12 above but comprising with the following accessories: -EAST POCKET B Main Panel (a) Bus bar electrolytic grade copper strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 1250 amps. (b) Main Incoming ACB 4 Pole, 415 V, with Thermal MagneticRelease (Manual Fixed type) of capacity, 800 amps, breaking cap 50 KA at 415 volts = 01 Nos (c) Outgoing MCCB four pole 415 V AC, current rating 320 amps, breaking cap 36 KA at 415 volts = 01 No (d) Outgoing MCCB four pole 415 V AC, current rating 250 amps, breaking cap 36 KA at 415 V AC = 01No (e) Outgoing MCCB four pole 415 V AC, current rating 200 amps, breaking cap 25 KA at 415 V AC = 02 Nos (f) Outgoing MCCB four pole 415 V AC, current rating 160 amps, breaking cap 25 KA at 415 V AC = 01No (g) Outgoing MCCB four pole 415 V AC, current rating 125 amps, breaking cap 16 KA at 415 V AC = 02 Nos (h) LED Multifunction meter flush panel mounting 96x96 mm, having parameters such as V,A,F,PF,KW,KVA, KVAR,KWH,KVAR,neutral currant, % Load,Max Demand(KW&KVA)-01 No(On incoming)
(j) LED indicator (R,Y,B) of suitable capacity (k) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (l) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 1250/5 amps, 15 VA accuracy class – 3 Set of three
All as per srl item No 12 above but comprising with the following accessories: EAST POCKET B FP-1 (a) Bus bar electrolytic grade copper strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 600 amps. (b) Main Incoming MCCB four pole 415 V AC, current rating 250 amps, breaking cap 36 KA at 415 volts -01 No (c) Outgoing MCCB four pole 415 V AC, current rating 125 amps, breaking capacity 16 KA at 415 volt -02 Nos Outgoing MCCB four pole 415 V AC, current rating 63 amps, breaking cap 16 KA at 415 V AC = 02 Nos (d) LED Multifunction meter flush panel mounting 96x96 mm,having parameters such as V,A,F,PF,KW,KVA, KVAR, KWH,KVAR,neutral currant,% Load,Max Demand(KW&KVA)-01 No(On incoming) (e) LED indicator (R,Y,B) of suitable capacity (F) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (G) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 600/5 amps, 15 VA accuracy class – 3 Set of three
All as per srl item No 12 above but comprising with the following accessories: -EAST POCKET B FP-2 (a) Bus bar electrolytic grade copper strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 600 amps. (b) Main Incoming MCCB four pole 415 V AC, current rating 320 amps, breaking cap 36 KA at 415 volts = 01 No (c) Outgoing MCCB four pole 415 V AC, current rating 125 amps, breaking capacity 16 KA at 415 volt -04 Nos (d) LED Multifunction meter flush panel mounting 96x96 mm,having parameters such as V,A,F,PF,KW,KVA,KVAR ,KWH,KVAR,neutral currant,% Load,Max Demand(KW&KVA)-01 No (On incoming) (e) LED indicator (R,Y,B) of suitable capacity (f) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (g) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 600/5 amps, 15 VA accuracy class – 3 Set of three
All as per srl item No 12 above but comprising with the following accessories: -EAST POCKET B FP-3,FP-4 (a) Bus bar electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 300 amps. (b) Main Incoming MCCB four pole 415 V AC, current rating 200 amps, breaking cap 25 KA at 415 volts =1 No (c) Outgoing MCCB four pole 415 V AC, current rating 100 amps, breaking capacity 16 KA at 415 volt : 02Nos (d) Outgoing MCCB four pole 415 V AC, current rating 63 amps, breaking capacity 16 KA at 415 vol 0: 2 Nos (e) LED Multifunction meter flush panel mounting 96mm x 96 mm,having parameters such as V,A,F,PF,KW,KVA ,KVAR,KWH,KVAR,neutral currant,% Load,Max Demand(KW&KVA)-01 No(On incoming) (f) LED indicator (R,Y,B) of suitable capacity (g) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (h) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 300/5 amps, 15 VA accuracy class - 3 Set of three
All as per srl item No 12 above but comprising with the following accessories: -EAST POCKET B FP-5 (a) Bus bar electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 200 amps. (b) Main Incoming MCCB four pole 415 V AC, current rating 160 amps, breaking cap 25 KA at 415 volts -01 No (c) Outgoing MCCB four pole 415 V AC, current rating 100 amps, breaking cap 16 KA at 415 volts -02 NOS (d) LED Multifunction meter flush panel mounting 96mm x 96 mm,having parameters such as V,A,F,PF,KW,KVA, KVAR,KWH,KVAR,neutral current,% Load,Max Demand(KW&KVA)-01 No(On incoming) (e) LED indicator (R,Y,B) of suitable capacity (f) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (g) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 300/5 amps, 15 VA accuracy class - 3 Set of three
All as per srl item No 12 above but comprising with the following accessories: -EAST POCKET B FP-4 (a) Bus bar electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 400 amps. (b) Main Incoming MCCB four pole 415 V AC, current rating 200 amps, breaking cap 25 KA at 415 volts =1 No (c) Outgoing MCCB four pole 415 V AC, current rating 100 amps,breaking cap 16 KA at 415 V AC = 02Nos (d) Outgoing MCCB four pole 415 V AC, current rating 63 amps, breaking capacity 16 KA at 415 volt (e) LED Multifunction meter flush panel mounting 96x96 mm,having parameters such as V,A,F,PF,KW,KVA, KVAR,KWH,KVAR,neutral currant,% Load,Max Demand(KW&KVA)-01 No(On incoming) (f) LED indicator (R,Y,B) of suitable capacity (g) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (h) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 400/5 amps, 15 VA accuracy class - 3 Set of three
All as per srl item No 12 above but comprising with the following accessories: -EAST POCKET B FP-1, POCKET C FP-4 (a) Bus bar electrolytic grade copper strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 600 amps. (b) Main Incoming MCCB four pole 415 V AC, current rating 250 amps, breaking cap 36 KA at 415 volts =01 No (c) Outgoing MCCB four pole 415 V AC, current rating 160 amps,breaking cap 25 KA at 415 V AC = 02Nos (d) Outgoing MCCB four pole 415 V AC, current rating 125 amps, breaking capacity 16 KA at 415 volt (e) LED Multifunction meter flush panel mounting 96x96 mm,having parameters such as V,A,F,PF,KW,KVA, KVAR,KWH,KVAR,neutral currant, (f) LED indicator (R,Y,B) of suitable capacity (g) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (h) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 600/5 amps, 15 VA accuracy class - 3 Set of three
All as per srl item No 12 above but comprising with the following accessories: -EAST POCKET C Main Panel (a) Bus bar electrolytic grade copper strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 1000 amps. (b) ACB four pole 415 V AC, current rating 630 amps, breaking cap 50 KA at 415 volts = 01 No (c) Outgoing MCCB four pole 415 V AC, current rating 250 amps,breaking cap 35 KA at 415 V AC = 02 Nos (d) Outgoing MCCB four pole 415 V AC, current rating 200 amps,breaking cap 25 KA at 415 V AC = 02 Nos (e) Outgoing MCCB four pole 415 V AC, current rating 100 amps, breaking capacity 16 KA at 415 volt = 01 No (f) LED Multifunction meter flush panel mounting 96mm x 96 mm,having parameters such as V,A,F,PF,KW,KVA, KVAR,KWH,KVAR,neutral current, (g) LED indicator (R,Y,B) of suitable capacity (h) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (i) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 1000/5 amps, 15 VA accuracy class - 3 Set of three
All as per srl item No 12 above but comprising with the following accessories: -EAST POCKET C FP-1 (a) Bus bar electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 300 amps. (b) Main Incoming MCCB four pole 415 V AC, current rating 200 amps, breaking cap 25 KA at 415 volts = 01 No (c) Outgoing MCCB four pole 415 V AC, current rating 125 amps,breaking cap 16 KA at 415 V AC = 02Nos (d) Outgoing MCCB four pole 415 V AC, current rating 63 amps,breaking cap 16 KA at 415 V AC = 01 No (e) LED Multifunction meter flush panel mounting 96x96 mm, having parameters such as V,A,F,PF,KW,KVA, KVAR,KWH,KVAR,neutral current,% Load, (f) LED indicator (R,Y,B) of suitable capacity (g) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (h) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 300/5 amps, 15 VA accuracy class – 3 Set of three
All as per srl item No 12 above but comprising with the following accessories: -EAST POCKET C FP-2 (a) Bus bar electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 400 amps. (b) Main Incoming MCCB four pole 415 V AC, current rating 250 amps,breaking cap 36 KA at 415 V AC = 01No (c) Outgoing MCCB four pole 415 V AC, current rating 100 amps,breaking cap 16 KA at 415 V AC = 02Nos (d) Outgoing MCCB four pole 415 V AC, current rating 63 amps, breaking capacity 16 KA at 415 volt -02 Nos (e) LED Multifunction meter flush panel mounting 96x96 mm,having parameters such as V,A,F,PF,KW,KVA ,KVAR,KWH,KVAR,neutral currant, (f) LED indicator (R,Y,B) of suitable capacity (g) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (h) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 400/5 amps, 15 VA accuracy class - 3 Set of three
All as per srl item No 12 above but comprising with the following accessories: -WEST POCKET A Main Panel (a) Bus bar electrolytic grade copper strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 800 amps. (b) Main Incoming MCCB four pole 415 V AC, current rating 500 amps, breaking cap 50 KA at 415 volts= 01 No (c) Outgoing MCCB four pole 415 V AC, current rating 200 amps,breaking cap 25 KA at 415 V AC = 02Nos (d) Outgoing MCCB four pole 415 V AC, current rating 125 amps,breaking cap 16 KA at 415 V AC = 02Nos (e) LED Multifunction meter flush panel mounting 96mm x 96 mm,having parameters such as V,A,F,PF,KW,KVA, KVAR,KWH,KVAR,neutral currant, (f) LED indicator (R,Y,B) of suitable capacity (g) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (h) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 800/5 amps, 15 VA accuracy class - 3 Set of three
All as per srl item No 12 above but comprising with the following accessories: WEST POCKET A FP3,FP4 (a) Bus bar electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 400 amps. (b) Main Incoming MCCB four pole 415 V AC, current rating 200 amps,breaking cap 36 KA at 415 V AC = 01No (c) Outgoing MCCB four pole 415 V AC, current rating 63 amps,breaking cap 16 KA at 415 V AC = 05Nos (d) LED Multifunction meter flush panel mounting 96mm x 96 mm,having parameters such as V,A,F,PF,KW,KVA, KVAR,KWH,KVAR,neutral current, (e) LED indicator (R,Y,B) of suitable capacity (f) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (g) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 400/5 amps, 15 VA accuracy class – 3 Set of three
All as per srl item No 12 above but comprising with the following accessories: -WEST POCKET B Main Panel (a) Bus bar electrolytic grade copper strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 800 amps. (b) Main Incoming MCCB four pole 415 V AC, current rating 500 amps, breaking cap 50 KA at 415 volts = 01 No (c) Outgoing MCCB four pole 415 V AC, current rating 200 amps,breaking cap 25 KA at 415 V AC = 02Nos (d) Outgoing MCCB four pole 415 V AC, current rating 63 amps,breaking cap 16 KA at 415 V AC = 02Nos (e) Outgoing MCCB four pole 415 V AC, current rating 100 amps,breaking cap 16 KA at 415 V AC = 01No (f) LED Multifunction meter flush panel mounting 96mm x 96 mm,having parameters such as V,A,F,PF,KW,KVA, KVAR,KWH,KVAR,neutral currant, (g) LED indicator (R,Y,B) of suitable capacity (h) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (i) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 800/5 amps, 15 VA accuracy class – 3 Set of three
All as per srl item No 12 above but comprising with the following accessories: -WEST POCKET B FP-4, North Main Panel (a) Bus bar electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 300 amps. (b) Main Incoming MCCB four pole 415 V AC, current rating 200 amps,breaking cap 25 KA at 415 V AC = 01 No (c) Outgoing MCCB four pole 415 V AC, current rating 63 amps,breaking cap 16 KA at 415 V AC = 05 Nos (d) LED Multifunction meter flush panel mounting 96mm x 96 mm,having parameters such as V,A,F,PF,KW,KVA, KVAR,KWH,KVAR,neutral currant, (e) LED indicator (R,Y,B) of suitable capacity (f) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron.
Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 300/5 amps, 15 VA accuracy class - 3 Set of three Note for Ser Item No 12 to 35 : (i) ACB shall be of type drawout version,Icu=Ics=Icw=50KA,advance self powered electronic protection unit MP2 & MP4,Neutral Overload Protection - OFF-50 %-100 %,Rotatable Terminals for Horizontal/Vertical Orientation (ii) MCCB shal be of adjustable thermal and magnetic release with Ics=Icu=100% (iii) Drawing shall be approved by GE before Execution of work
Supply and Fixing HT Aerial Bunched Cable XLPE insulated Cable 11000V graded 185x 3c + 150 Sqmm messenger laying/Hanging on the pole/ along the wall with necessary clamping/ hook system, suitable insulating materials and winding confirming to IS:7098 part-2 ,2011 aluminium e.c. grade as per IS-8130/2013 suitable for 50 deg temp complete all as specified and as directed. Note: Unit rate quoted by the contractor includes all fittings required for fixing of ABC cable like suspension clamps, dual and clamps, anchoring clamps, tension clamps, D hook etc.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground (Earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected and including GI strip 32 mmx6mm (upto the body of equipment) by means of brazing, GI bolts, nuts, check nuts and washers, earth plates surrounded by packed layers of coal dust and common salt 15 cm thick all around top and bottom and watering pipe 20 mm bore of GI pipe, light grade including protection pipe of size 40 mm all as shown in Electrical plate No 5 of SSR Part I, testing on completion including PCC 1:2:4 tye B1 using 20mm graded stone aggregate as in pit cover and PCC chamber in PCC 1:3:6 type C-1 using 20mm graded stone aggregate including excavation and earth work, disposal of surplus spoil to a distance n exc 50 m complete all as specified and directed by Engineer-in-Charge
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground (Earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected and including GI wire 4 mm dia (upto the body of equipment) by means of brazing, GI bolts, nuts, check nuts and washers, earth plates surrounded by packed layers of coal dust and common salt 15 cm thick all around top and bottom and watering pipe 20 mm bore of GI pipe, light grade incuding proection pipe of size 25 mm all as shown in Electrical plate No 3 of SSR Part I, testing on completion including PCC 1:2:4 tye B1 using 20mm graded stone aggregate as in pit cover and PCC chamber in PCC 1:3:6 type C-1 using 20mm graded stone aggregate including excavation and earth work, disposal of surplus spoil to a distance n exc 50 m complete all as specified and directed by Engineer-in-Charge
Construction of platform of size 3000mm x 2500mm x 1200 mm for installation of transformer with brick steps on one side, chain link fencing around transformer, fencing should have hinged door and locking arrangements complete all as shown on drawing No CEPZ/C-TD/002/13 sht 2/5 complete all as specified.
Cable route indicator for LT Cables include PCC Work complete, all as specified and directed. Note:- The cable route indicator shall be with circular minimum dia 150 mm and minimum 6 mm thick cast iron plate embossed with "LT cable" riveted to angle iron of (25mm x 25mm x 5mm) of length minimum 60 cm and embedded in PCC 1:2:4 foundation of 30 cm x 30cm x 30cm.
Material and labour for PCC (1:1.5:3) type A1(using 20mm graded stone aggregate )cover slab of size 300mm wide and 600mm height and 100 mm thick oval shape on top .The precast slab shall be embedded 300 mm below GL in PCC(1:3:6) of size 450mmx450mmx450mm) including engraved the words in capital letters of size 5cm height and 2cm width "MES HT 11KV CABLE /CABLE JOINT"including necessary surface finish with plastering 10mm thick in CM(1:3)and two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation of size 310mmx150mmx300mm and removing complete all as directed.
Stay assembly galvanised iron complete with accessories stay rod 18mm dia, 180cm long with two nuts, stay bow 14mm dia and 38cm long with stay plate 300x300x6mm thickmild steel stay thimble and required length including binding to insulator stay bow and stay clamp galvanised iron stary strand wire 7/4mm dia complete all as specified and shown in EP plate No 1 alongwith Loop type insulator ,vitreous porcelin , white brown or green complete all as specified and directed by Engineer in charge.
SECURITY WALL AND FENCING
Filling of crumple joint with 25 mm thick Polystyrene (Thermocol) complete all as specified and directed
Supply and fixing Concertina coil fencing with punched tape concertina coil 600 mm dia stretched to 6.00 mtrs length having 50 nos spiral turns per 6.00 mtrs length ,spiring coil wire (2.59 mm thick) of high tensile strengh of 1620 N/ sqmm with tape (0.52 mm thick ) hot dip galvanised up to 20 microns ,weight of each coil 8.50 kg and fixing the same on existing Y- shaped angle iron with 6 6 Harizantal R.B.T.(Reinforced barbed tape ) wire stud tied with G.I stapple sand G.I clips to retain harizantal, clips shall be @ 5 Nos per 2 sopiral turns approximate 125 clips per coil including necessary bolts complete all as specified and as directed .
Note: The schedule of credit has been attached in tender in Pdf format and amount of credit schedule i.e. Rs 272150.00 shall be deducted from the total amount of BOQ to arrive at the contract sum.
R D Bansal
TRIVENI CONSTRUCTIONS
SATISH AND CO
M/S JIWAN KUMAR MITTAL
PARDEEP ELECTRICALS AND BUILDERS PRIVATE LIMITED
M/S BHATIA BUILDERS AND CONTRACTORS
B S Ranbir and Co
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .