| 1 | L1₹6.8 LAccepted-AOC 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L1 | Accepted-AOC L1 bidder accepted | |
| 2 | L2₹8.8 L+₹2.0 L (29.2%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹8.8 L+₹2.0 L (29.6%)Rejected-Finance III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L3 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹6.2 L
EMD Value
₹12,420
Closing Date
7 Jun 2025, 6:00 pmClosed
CWE NEW DELHI
HQ CWE NEW DELHI
COMPREHENSIVE, PREVENTIVE AND PERIODICAL MAINT OF LIFTS AT A BLOCK, D BLOCK, P94, E BLOCK AT GE EM RR HOSP, DELHI CANTT10
2025_MES_704495_2
CWE-ND/04/2025-26
Open Tender
Civil Works - Others
Item Rate
365 days
DELHI
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE EM RR HOSP DELHI CANTT
₹12,420
Yes
22 Jul 2025
19 May 2025
9 Jun 2025
19 May 2025
7 Jun 2025
26 May 2025
Amount
Comprehensive, preventive and periodical maintenance of lifts/elevators/dumbwaiters installed in AHRR Complex as mentioned here-in-after, in reliable, safe and efficient manner using latest techniques & expertise consultancy by regularly examining, lubricating and adjusting the mechanical and electrical driving equipment incl replacement of unsv componenents such as, governor sleeve, shaft assembly, bearing / contact, governor jaws, car & hall mechanical buttons, car & hall position indicators, car direction indicators and all other car and landing signal / fixtures, deflectors, counter weight, guide rails, buffers, machines motors, generators, door ropes, ARD system, PCBs, belts, rollers, gears, bearings, solenoids, coils, chock brake shoes, liners, contactors, relays, coils, pushbuttons, door operator VVF drive, VVVF main drive, cardoor safety device, limit switches, governor, hoistway door locks, indicators and other machanical and electrical parts (excpet car cabin, landing door, sheave rim and Srl item No 02 to 10 of Sch 'A') for smooth functioning of elevators and incl all machine works i.e. welding, cutting, drilling, screwing, etc. as and when required, to entire satisfaction of Engineer-in-charge, incl cost of materials complete incl Sunday and holiday all as specified & directed for following Lift(s) / Elevator(s) -
Electric Hospital passneger cum stretcher elevator /lifts of capacity 20 passenger serving (-1+G+4) 6 floors installed at E Block (No 9281) (Make : TKE Elevator) -01 Nos lifts
Electric Hospital passneger cum stretcher elevator /lifts of capacity 26 passenger serving (G+4) 5 floors installed at A Block (No 9248) (Make TKE Elevator) -01 Nos lifts
Electric Hospital passneger cum stretcher elevator /lifts of capacity 20 passenger serving (G+4) 5 floors installed at D Block (No 13557) (Make TKE Elevator) -01 Nos lifts
Electric passneger elevator /lifts of capacity 08 passenger (544 Kgs) serving (G+5) 6 floors installed at P-94 Block (Make Kone Elevator) -01 Nos lifts.
Notes for item No. 1.00 to 1.04: (i) The above maintenance shall be done through OEM of existing lifts. Please also refer Sch 'A' Notes. (ii) The contractor shall have to submit MOU from OEM M/S TKE(for Item No. 1.01 to 1.03) and M/S Kone Elevator(for Item No. 1.04). (iii) The rates quoted shall be inclusive of T&P required for carrying out repairs, stationary for maintenance of record all as specified. (iv) All the cleaning items (Dusting cloths, floor/Glass cleaner, SS steel cleaner, broom etc) shall be provided by the contractor and rates deemed to be included in the quoted rate. Otherwise a penalty of Rs. 100/- per day will be charged. (v) Any items not covered in Sch 'A' (except car cabin, landing door, sheave rim and Srl Item No 02 to 18 of Sch A) shall be deemed to be included in the unit rate quoted for above item for the smooth functioning of lifts and the contractor may quote the rate accordingly. Contractor is expected to inspect the lift before quoting the rate and Lifts will be handed over in the same condition. No claim will be admissible thereof.
Notes for item No. 1.00 to 1.04 (contd.):- (vi) Contractor shall be attending complaints round the clock i.e. 24 hrs. If contractor is not able to rectify the complaint, penalty shall be charged as given below:- (a) up to 1st day- NIL (b) 2nd day- Rs 1000/- day (c) Subsequency for every days - Rs 2000/day. (vii) Contractor shall be responsible to register the day to day complaints of lifts and addressed the same with in the stipulated timeframe and the complaint register will be putup to the JE / Engr-in-charge on daily basis. (viii) The comprehensive / preventive / periodical maint incl fortnightly, monthly, quarterly, half yearly inspection / testing as per service manual or as per IS standard will be submitted to Engr-in-charge. (ix) Contractor shall submit safety security certificate of lifts from OEM in every month as per performa mentioned in tender documents. (x) Adequate arrangements shall be made to dewatering the lift pit as and when water accumulates. Cost Should be included in the quoted rate. Otherwise penality of Rs 500 per day per lift will be recovered from the contractor. (xi) Contractor shall be responsible to update the imp tele number and safety precautions of inside the car cabin of each lifts and update the same time to time.
KONE’s liability to the CUSTOMER for any defects in design, materials or workmanship relating to parts and components shall be limited to the replacement of spare parts or components as defined by this Article. a) Refinishing, repair or replacement of following components are outside the scope of this contract: I. Elevator car enclosure II. Elevator car and landing door panels / gates III. Alarm bell/buzzer IV. Incoming Electrical wiring up to main switches in the m/c room V. Main switches in the m/c room VI. LCD's, Touch Panels, Media Screens VII. Any other equipment or accessory not forming part of the initial supply of the elevator equipment although provided as a necessary accessory by or to the customer .This includes Accessories such as EBD / KRD , Intercom , LAS ,BMS,DCS,E-Link & Group Indicators . VIII. Decorative items including mirror and hand rail Material groups excluded from repair coverage Battery UPS Lights Fan
Supply & fix in replacement of SMF Battery 12 V 18 AH or all as per site requirement complete all as specified & directed.
Supply & fix in replacement of SMF Battery 12 V 7 AH or all as per site requirement complete all as specified & directed.
S&F in replacement MCB TPN 20 Amps complete all as directed.
S&F in replacement MCB TPN 63 Amps complete all as directed.
Supply and fix in repair, of blower by taking down unserviceable blower and replacement of defective part including oiling/greasing and rewinding of blower motor as required complete all as specified and as directed.
Supply & fix in replacement as in shaft light of lift environmental friendly, ultra modren, energy saving LED fitting 20W with all connection incl wiring all as per site requirement complete all as specified and directed.
S&F in replacement cabin light decorative recess mounted round/square fixture (as per existing size and type) in white finish with opal diffuser and electronic driver, suitable for car cabin complete all as per site requirement directed by Engr-in-Charge.
S&F in replacement RCCB in sheet metal enclosure 40 Amps, 300mA, four pole, 415 Volts complete all as directed.
Supply & fix in replacement travelling cable multistranded copper conductor of size 12 core 0.5 sqmm as pe OEM all as directed by Engr-in-Charge.
S&F handle bar of all sides of size 35 mm and above in 20/26 passanger cum stretcher elevator by taking down old unserviceable bar complete all as specified and as directed.
S&F acrylic board for writing lift instruction including writing instruction as directed and fixing the acrylic board inside car cabin with the help of screws/studs complete all as specified and directed.
Material and labour for removal of dust, stain marks, scratches, on stainless steel surface of landing door including landing frame and carry out scrubbing, polishing, buffing of stainless steel polish liquid and buffing toolto give glossy and clean finish to lift cabin surface of 20/26 passanger cum stretcher lift complete all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge.
Demolition of un-reinforced Concrete of any description and in any position not otherwise specifically provided for complete all as specified
M&L rendering 15mm thick in CM 1:4 on external fair faces of brick work or concrete surface to fair and even without using extra cement complete all as specified and as directed
Providing & applying two coats of Acrylic Elastomeric Exterior waterproofing compound of “Dr. Fixit Raincoat” or equivalent approved make and one coat of approved priming coat as per the waterproofing coating manufacturer to vertical wall/floor surfaces at any level and location including scaffolding etc. complete, as per instruction of the Engineer in Charge.
(a) M&L clean the surface, remove dust dirt, loose particles and unsound substrate and providing 20 mm thick cement screed (1:4) mixed with Dr Fixit or equivalent tonic liquid 200 gram/Bag over Dr Fixit or equivalent as approved by GE. (b) Applying primer coat with solvent based Bitumen primer @ 0.5 ltr/sqm. (c ) Dr Fixit or equivalent as approved by GE torch shield water proofing 3mm thick membrane use gas burner to heat substrate, press firmly from lower end to upper and with 100 mm overlap. (d) Heat both over lap with round tipped trowel to seal over lap . Excess compound smoothened, pressed into seam using hot trowel. (e) Seal edges well into grooves & protect with a poly sulphide sealant. (f) M&L hydraulically pressed burnt clay tiles plain size 300X300X19 mm laid over and including 15mm thick screed in CM 1:4 with WPC & pointed in CM 1:3 mixed with crude oil. (Note 1 :- WPC as per manufacturer's instruction shall be deemed to be included in unit rate quoted.) (Note 2 : Water proofing treatment shall be carried out through approved manufacturer's applicator). (g) Uploading of material shall be carried out by mechanical means, use of staircase is strically probihited
Providing and laying cement concrete floor (Indian Patent Stone) 40 mm to 65 mm thick to maintain required slope, P.C.C.(1:2:4) mix using 12.5 mm graded stone aggregate, adding fiber mesh @125 gms/cement bag and sunplex @ 330 gms /cement bag laid in alternate bays troweled smooth on top in neat cement and making lines on the top surface diagonally or square at spacing, curing for minimum 7 days, as directed etc. complete.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
M&L brick work with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 with old size bricks
S&F 4.8mm thick sheet glass, ordinary quality and glazing with oil putty in square n. exc 0.5 sq. m in each pane
M&L for preparation of newly plastered surface of wall and applying two coat of weather proof exterior emulsion extra premium 100% acrylic emulsion as approved over a coat of primer complete all as specified and directed.
S&F of transparent acrylic paper holder using nut/bolts/studs complete all as specified and as directed.
S&F stainless steel plate 5 mm thick for writing lift instruction using engraving/itching method and fixing using nut/bots/studs complete all as specified and as directed
M&L for replacement of earthing with Galvanised Steel earth plate electrode of size 600 x 600 x 6mm thick directly burried in ground (earth pit not less then 4Mtr deep below ground level with tope edge of earth plate not less than 1.5 Mtr below the ground level connected by GI Earth Strip of Size 32x 6mm thick by means of Bolts, Nut,Check Nuts and Washer of GI or Steel GI Pipe 40mm Bore light grade for protection of earthing strip, PCC CHAMBER 1:4:8 TYPE D-1 using 20mm graded stone agg. Internal surfaces of chamber shall be plastered 12mm thick in CM 1:4 funnel with wire guage of 22 guage(0.63mm) 8 mesh per linear inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm grade stone agg. reinforced with 8mm dia TMT Bar @80mm C/C both ways and charcoal dust and common salt all as specified and shown in electrical plate No of 5 of SSR part-I including excavation of earth work, returning , filling, removing surplus soil not exc 50 m and connecting the earthing to an earthing test point as specified and testing on completion.
Supply & fix in repair GI strip 32x6mm, buried in ground or fixed to wall incl saddling etc for loop earthing complete all as specified and directed.
J D ENTERPRISES (BID ID -3316105)
MB Enterprises (BID ID -3305991)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .