Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹57.4 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹57.7 L+₹28,184.41 (0.49%)Admitted-Finance | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | N K Enterprises L1 | ANAND KUMAR L2 |
|---|---|---|---|---|---|
| 1.00 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. | 268.88 | M2 | 15 ₹4,033.23 | 12.73 ₹3,422.87 Lowest |
| 2.00 | Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible brush, roller or spray for water proofing coating as per manufacturer specifications with following steps -(a)surface preparation :-Provrding and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joinis such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with ceme nt slurry including all material, labour, tools complete.
(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqm/coat For the purpose of measurment the entire treated surface will be measured."
(c) :2nd Coat :- To apply the 2nd coat of two component acrylic modified ready to use, flexible cementitious material right angle to the '1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kgl Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." After three days of drying the 2nd coat , the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification lo be done as per satisfation of E/I,. the water proof coating to be protected from damage before screed over it. Watqrproofing Brand Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2K/MYK Aqraiin TG Product Performance - Chemical Base Part A. Acrylic copolymer, Part B Specially graded cementitious powder Density 1.6 kg/l (mixed density) at +27oC Tensile Strength 2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength 2N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% wilh Fibre Cloth (Accordrng to ASTM D 2370)
(d) Protection of treated surface with PCC :- The treated surface shourd be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope (1:120) towards the rain outlets in alternatepanels of 2 mtx2mt keeping 6 mm gap between the panel joint. lntegral water proofing admixture conforming to lS 2645 @ of 100 ml per bag ofcement to be added in the screed concrete (paid separately for this ltems).-All corners shall be chamferd with 150mm X 150 mm fillet. The rain water outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface slrould be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / MYK Schomberg / Dr Fixit/Fosroc. | 1,662.07 | M2 | 350 ₹5,81,723.45 Lowest | 392 ₹6,51,530.26 |
| 3.00 | Covering of treated surface wrth PCC :- Providing 25 mm thick Cement Concrete M20(1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of F M 2 5 to 3 including screening,shuttering,and mixing cement concrete in mixer with admixture of integral water proofing and placing in position, striking curring, taxes and royality all complete as per building specifiction and direction of E/l.Panels that has been left should be casteci next day.-there should be 6 mm gap between Panels.Brand Sika Plastocrate plus, MYK proof WP10, Fosroc- Conplast X421ic , Dr Fixit Pidiproof LW+ | 1,662.07 | M2 | 150 ₹2,49,310.05 | 143.64 ₹2,38,739.3 Lowest |
| 4.00 | Taking down old door and window shutters including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. | 65 | Each | 28 ₹1,820 | 26.75 ₹1,738.75 Lowest |
| 5.00 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. | 88.35 | M2 | 135 ₹11,927.52 | 112.47 ₹9,936.95 Lowest |
| 6.00 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. | 180.53 | M2 | 120 ₹21,663.6 | 102.57 ₹18,516.96 Lowest |
| 7.00 | Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush shutters doors and windows with black board core blended with high quality phenol formal dbhydes synthetic resin both side commercial veneered of standard make with oxidised iron fittings etc. all complete as per building specification and direction of E/I. | 18.24 | M2 | 1,300 ₹23,709.4 | 1,146.22 ₹20,904.76 Lowest |
| 8.00 | Supplying, fitting and fixing glass panes including supplying putty, beads and nails after taking out old and broken glass panes and disposal of debris all complete as per building specification and direction of E/I.
4mm plain | 35.69 | M2 | 450 ₹16,058.25 Lowest | 462.19 ₹16,493.25 |
| 9.00 | Easing and adjusting door and window shutters with chaukhats in old work complete as per specification and direction of E/I. | 95 | Each | 80 ₹7,600 | 66.89 ₹6,354.55 Lowest |
| 10.00Supplying, fitting and fixing oxidised iron fittings of approved quality and make to doors and windows all complete as per building specification and direction of E/I. | |||||
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
21 Jun 2021, 11:00 amClosed
Nodal Officer
e-Procurement Cell, Office of the Superintending Engineer, Building Construction Department, Chotanagpur Circle, Line Tank Road, Ranchi.
Renovation of Main Hospital, IPD Ward and Nurse Hostel of MESO Hospital at Arki, Block-Arki, Dist.-Khunti For the Year-2021-22
2021_BCD_49523_1
BCD/SECNC/02/BCD,Div, Khunti/2021-22 Date-20.04.20
Open Tender
Civil Works
Works
185 days
Khunti
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
E.E, BCD, Building Division Khunti
₹1.4 L
Yes
28 Jun 2021
8 May 2021
23 Jun 2021
8 May 2021
21 Jun 2021
8 May 2021
Amount
Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible brush, roller or spray for water proofing coating as per manufacturer specifications with following steps -(a)surface preparation :-Provrding and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joinis such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with ceme nt slurry including all material, labour, tools complete. (b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqm/coat For the purpose of measurment the entire treated surface will be measured." (c) :2nd Coat :- To apply the 2nd coat of two component acrylic modified ready to use, flexible cementitious material right angle to the '1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kgl Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." After three days of drying the 2nd coat , the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification lo be done as per satisfation of E/I,. the water proof coating to be protected from damage before screed over it. Watqrproofing Brand Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2K/MYK Aqraiin TG Product Performance - Chemical Base Part A. Acrylic copolymer, Part B Specially graded cementitious powder Density 1.6 kg/l (mixed density) at +27oC Tensile Strength 2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength 2N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% wilh Fibre Cloth (Accordrng to ASTM D 2370) (d) Protection of treated surface with PCC :- The treated surface shourd be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope (1:120) towards the rain outlets in alternatepanels of 2 mtx2mt keeping 6 mm gap between the panel joint. lntegral water proofing admixture conforming to lS 2645 @ of 100 ml per bag ofcement to be added in the screed concrete (paid separately for this ltems).-All corners shall be chamferd with 150mm X 150 mm fillet. The rain water outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface slrould be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / MYK Schomberg / Dr Fixit/Fosroc.
Covering of treated surface wrth PCC :- Providing 25 mm thick Cement Concrete M20(1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of F M 2 5 to 3 including screening,shuttering,and mixing cement concrete in mixer with admixture of integral water proofing and placing in position, striking curring, taxes and royality all complete as per building specifiction and direction of E/l.Panels that has been left should be casteci next day.-there should be 6 mm gap between Panels.Brand Sika Plastocrate plus, MYK proof WP10, Fosroc- Conplast X421ic , Dr Fixit Pidiproof LW+
Taking down old door and window shutters including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush shutters doors and windows with black board core blended with high quality phenol formal dbhydes synthetic resin both side commercial veneered of standard make with oxidised iron fittings etc. all complete as per building specification and direction of E/I.
Supplying, fitting and fixing glass panes including supplying putty, beads and nails after taking out old and broken glass panes and disposal of debris all complete as per building specification and direction of E/I. 4mm plain
Easing and adjusting door and window shutters with chaukhats in old work complete as per specification and direction of E/I.
Supplying, fitting and fixing oxidised iron fittings of approved quality and make to doors and windows all complete as per building specification and direction of E/I.
100mm Butt Hinge
250mm Tower Bolt
Providing two coats of synthetic enamel paint of approved shade and make over old wooden surface including cleaning the surface after removing dirt scales, smokes, grease and sand papering, including coat of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing two coats of synthetic enamel paint of approved shade and make over old wooden surface including cleaning the surface after removing dirt scales, smokes, grease and sand papering, including coat of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing two coats of synthetic enamel paint of approved shade and made over steel surface thoroughly, scaffolding and taxes all complete as per building specification and direction of E/I.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/I.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
15mm dia
20mm dia
25mm dia
Providing and fixing male ended 15mm dia brass bib cock of approved quality with extra socket all complete as per specifiation and direction of E/I.
Providing and fixing brass C.I. stop cock of approved quality all complete as per specification and direction of E/I.
Brass Stop Cock - 15mm dia
20mm dia
S/F/F the following items complete with all materials as per specification and direction of E/I.
Glass Shelf with C.P. Brass rail 600x125mm
Mirror of 4mm thick plate glass mirror with hard wood backing or 3mm ply wood board - 600x450mm
C.P. Brass towel rail 20mmx600mm with bracket container
C.P. Brass liquid shop container
Supplying labour, tools and tackels for cleaning filled and choaked main hole, septic tank, inspection chamber, gullay pits, sewerage tank with all lift and disposal of spoils upto a lead of 50M all complete as per specification and direction of E/I.
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing. 30 mm thick plain PVC door shutters
S/F/F viterious white glazed earthen ware wash hand basin of parry or hindustan or any other ISS approved make supported on painted CI or RS brackets 32mm CI brass waste 15mm dia CI body brass spindle stop cock of approved quality of weight not less than 350grms 32mm PVC waste pipe 750mm long with brass coupling at one end and making plumber joints etc all complete as per specification and direction of E/I.
S/F/F 40mm high viterous white glazed earthen EWC with P trap of parry hindustan or any other approved ISS make including supplying and fixing 15 litres CI mosquito proof low down flushing cistern of approved make with complete fittings with CI handle and RS or bracket with telescopic flush pipe with brass coupling and plumber joints spindle stop cock of approved quality wieght not less than 450grms 15mm pVC alkathene pipe 45cm long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cockoo or other ISS make with hinges or screws etc painting pipe and cistern etc with 2 coats of approved paint over a coat of red oxide priming all complete job.
Supplying, fitting and fixing flat back or angular lipped front vitreous white glazed earthenware urinal of “Hindustan” “Parry” or any other approved I.S.S make with 5 liters capacity C.I. automatic flushing cistern of reliance for any other I.S.S. approved make with all fitting with C.I or R.S brackets, standard size G.I flush pipe with fitting clamps, 15 mm C.I body brass spindle stop cock of approved quality weight not less than 400 grms,15 mm P.V.C alkathene pipe 450 mm long with brass coupling at both ends and doing plumber joints including painting of exposed part with 2 coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/I.
Supplying, fitting and fixing viterous white glazed earthen ware indian squating type 600 x 350 mm urinal plate of Parry Hindustan or any other I.S.S. approved make with internal flushing rim 100 mm white glazed earthen ware channel about 1m long 5litre capacity C.I. automatic flushing cistern of reliance or any other approved make with fittings C.I. or R.S. brackets 15 mm & 45 cm long P.V.C. alkathene pipe standard G.I. flush pipe for back and front with spreader fitting and brass coupling etc. 15mm C.I. body brass spindle stop cock weight not less than 450 grms. all complete including painting of exposed part with 2 coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/l.
600 mm x 350 mm size large
Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100 mm H.C.I., "p" trap 15 litres C.I.. or C. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32 mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I. body brass spindle stop cock of weight not less than 50 grms. 15 mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. 450mm long with 12.50 litre low level PVC cistern
Supplying, fitting and fixing H.C.I. pipes with ear of approved make confirming to I.S.I-1729 including supplying nails and bobbins shorts pieces, cutting loose collars lead and yarn for making lead caulked joints, cutting pipes of size including earth work or scaffolding where necessary etc. all complete as per specification and direction of E/I.
100 mm dia
75 mm dia
Supplying and fixing H.C.I fittings of approved make confirming to I.S.S. 1729 including supplying nails and bobbins lead and yam for making lead chaulked joints including earth work or providing scaffolding as the case may be all complete as per specification and direction of E/I.
H.C.I Single junction with door but without ear except socket
100 mm dia (Wt. 10.5 Kg. app.)
80 mm dia (Wt. 7 Kg)
H.C.I Heal Rest Bend
100 mm dia (Wt. 5.5. Kg. app.)
80 mm dia (Wt. 4 Kg. app.)
H.C.I double junction with door and ear
100 mm dia (Wt. 15.5 Kg. app.)
80 mm dia (Wt. 8.5 Kg. app.)
H.C.I bend with door and ear
100 mm dia (Wt. 6.5 Kg app.)
75 mm dia (Wt. 4.5 Kg app.)
Floor trap with gratings
100 mm dia
H.C.I Plain bend with ear
100 mm dia (Wt. 5.5 Kg app.)
75 mm dia (Wt. 3.75 Kg app.)
Supplying materials and labour for painting the exposed H.C.I. pipe and fitting with two coats of approved paint over a coat of red oxide primer etc all complete as per specification and direction of E/I.
100mm dia
80mm dia
Providing and laying vitrified floor tiles in diiierent sizes (thickness to be specified by lhe manufacturer) with water absorption less than 0.08% and conforming to lS 15622 of approved make in all colours and shades laid on 20mm thick cement mortar 1:4 (1 cement:4 coarse sand) jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A&B) and disposal of excavated earth as obtained to a distance upto 50M including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shurbs, all complete as per approved design, building specification and direction of E/I.
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume)
Providing designation 75B one brick flat joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
Providing P.C.C. M-150 with nominal mix of (1:2:4) in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking curing, taxes and royalty all complete as per building specification and direction of E/I.
Supplying M.S. angle of difference size in mm as per IS 226 of approved quality with 10% of contractor profit all complete job.
a) 50x50x6 (GR-A)
b) 65x65x6 (GR-A)
c) 75x75x6 (GR-A)
Labour for fabricating, erecting, hoisting and fixing in position structural steel work in R.S. joist, channel, Angle, Tee, flat, plate lattice member, built up compound section in column, girder, strait case or truss including cost of gusset plates, holding down bolts, anchor plates at all heights and depths, bolting, welding (machining wherever necessary) with applying a priming coat of red lead paint all complete as per approved drawing, building specification and direction of E/I.
Providing primer one coat of red lead paint of approved make over new steel surface & Providing two coats of synthetic enamel paint of approved shade and made over steel surface including preparing the surface after cleaning, removing rust, dirt scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes as complete as per building specification and direction of E/I. (Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification)
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12873SUB HEAD : 12- ROOFING metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
Labour for fitting and fixing G.C.I. or C.A. sheet roofing in proper slope including the cost of “J” or “L” hooks, limpet and bitumen washers, carriage of sheets to work site, and taxes etc. all complete as per building specification and direction of E/I.
Labour for fitting and fixing G.C.I. or C.A. sheet ridge including the cost of etc. all complete as per building specification and direction of E/I.
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250 apron including cost of earthwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly paltered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. all complete as per direction of E/I.
Providing RCC M-200 with nominal mix of (1:1.5:3) in lintel with approved quality of stone chips (20mm to 6mm size), graded and clean coarse sand of F.M. 2.5 to 3 including screening, centering, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing ( but excluding the cost of reinforcement ), taxes and royalty all complete as per building specification and direction of E/I.
Providing RCC M -200 with nominal mix of (1:1.5:3) in stiffners with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of FM 2.5 to 3 including screening, shuttering, mixing all complete as per building specification and direction of E/I.
Providing RCC M200 with nominal mix of (1:1.5:3) in roof slab with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 (but excluding the cost of reinforcement) including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking, curing (excluding cost of reinforcement), taxes and royalty all complete as per building specification and direction E/I.
Providing designation 75 B Brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of FM 2 to 2.5 including providing 10 mm thick mortar joints, costs of screening, materials, scaffolding, raking out joints to 15 mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing etc excluding carriage of MS Rods (TMT Fe 415) (Straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wore, removal of rust, placing the rods in position all complete as per building specification and etc. as per direction of E/I.
Filling in foundation trenches and plinth in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 m and lift of 1.5 m all complete as per building specification and direction of E/I (mode of measurement compacted volume)
Supplying, fitting and fixing 20 gauge G.C.I. sheet gate fitted on M.S. Angle frame of size 60x60x6mm including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Bend - 110mm
Shoe - 110mm
Carriage of materials from nearest approved sourses of supply including loading into trucks and unloading from truck and stacking properly at work site etc. all complete job as direction of E/I.
Bricks leads up to (1K+7P) K.M
Local Sand leads up to 3 K.M
Sand leads up to 8 K.M
Stone Chips leads up to 22 K.M
Stone Metal leads up to 20 K.M
Earth leads up to 3 K.M
Wiring for light point/exhaust fan point/call bell point with 1.5 sq.mm FRPVC insulated copper conductor single core cable in surface/recessed PVC conduct with piano type switch phenolic laminated sheet suitable size PVC/G.I. box etc as required.
Group B
Group C
Supplying and fixing following piano type switch/socket on the existing switch box/cover inlcuding connections as required.
5/6 amps one way switch
3 pin 5/6 amps socket outlet
Wiring for light/power plug with 2x4 sq.mm FRPVC insulated copper conductor single core cable in surface/recessed PVC conductor single core cable for loop earthing as required.
Wiring for circuit/submain wiring along with the following size pvc/insulated copper conductor single core cable in surface/recessed PVC conductor single core cable for loop earthing as required.
2x2.5 sq.mm + 1x2.5 sq.mm earth wire
2x6.0 sq.mm + 1x6.0 sq.mm earth wire
Supplying and fixing suitable size G.I./PVC box surface or in recess with phenolic laminated sheet cover in front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps piano type switch in connection painting etc as required.
Supplying & fixing 6 amps to 32 amps rating 240 volts "B" series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCBDB complete with connection testing and commissioning etc.
6/32 amps, single pole "B" series
40 amps single pole "B" series
Supplying & fixing following way single pole neutral sheet MCB distribution board 240 volts on surface/recess complete with tinned copper busbar neutral busbar earth bar din bar detachable gland plate interconnection phosphatized powder painted with complete job.
8 way single door
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the in existing cubicle pannel board with ISI marked HRC fuse including drilling holes in cubicle board making connection etc.
63 amps, TP&N
Supplying & fixing following rating TP&N 415 volts residual current circuit breaker having a sensitivity current circuit breaker having a sensitivity current upto 300 milliamprer in the existing MCBDB complete with connection testing and commissioning etc.
Installation testing and commissioning of ceiling fan including wiring the down rods of standard length (up to 30cm) with 1.5 sq.mm FRPVC insulated copper conductor single core cable etc as required.
Earthing with G.I. earth pipe 4.5 mtr long 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal and salt as required.
Supplying and fixing 8 SWG copper wire at 0.50 Mtr below ground level for conductor earth electrode including soldering etc as required.
Providing & fixing of lighting conductor final made of 25mm dia 300mm long copper tube having single pole at top with 85mm dia 3mm thick copper base plate including holes etc as required.
Reverting sweating and soldering lighting conductor taps/G.I. taps as required.
Providing & fixing of G.I. tap of 20mm dia 3mm thick on parapet or surface of wall for lighting conductor etc as required.
Providing & fixing of G.I. tap of 20mm dia 3mm thick on parapet or surface of wall for lighting conductor etc as required.
Supplying fixing of exashust fan complete job.
Supplying fixing of 1x28 W tube light with all complete job.
Supplying fixing of 36/40 W tube light fitting with all complete job.
Supplying fixing of bulk head with 9/10 watt CFL/LED with all complete job.
Supplying fixing of Ceiling rose 2 plate 5 Amps with all complete job.
Supplying fixing of Ceiling fan 48" dia DGS & D rate with all complete job.
Main Panel - Supplying, designing, manufacturing, installation, testing, fitting, fixing and commissioning in correct alignment position effecting proper connection of all incomers and outgoing of PDB panel of 14 SWG CRCA sheet (2mm) steil IP-54 floor mounting cubical type LT panel suitable for operation ofn 415V, 50Hz, 3Ph, AC supply and fault level 35KA. Apporexmate size (shall be given at the time of work order) with front operated construction including seperate fabrication arrangement for fixing of swithgears and meters.
Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of FM 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, ranking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 125mm thick reinforced designation 75A brick work in CM (1:4) in super structure with approved quality of clean coarse sand of FM 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15 mm depth, cutting, taxes and royalty but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.
S/F/F of C.I. cover with frame for manhole & inspection chamber with all complete job.
Add 12 % GST (in Basic Rate must fill 12)
Add 1% Labour Cess (in Basic Rate must fill 1)
ANAND KUMAR
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .