Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹7.2 L
EMD Value
₹18,100
Closing Date
15 Nov 2023, 10:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Gulbarga Electricity Supply Company Limited
Mahesh D Executive engineer
Estimate for bifurcation of load from overloaded F-7 Nelajeri IP set feeder emanating from 110/33/11 Kv MUSS Mangalore by creating NEW IP set feeder from 110/11 Kv Chilakamukhi MUSS at sharanappa Sidaganahalli IP land in O&M Mangalore Section of Yelburga Sub Division. Under partial turnkey basis. Poles and Conductor, DP Structure, GOS with H-frame will be supplied by GESCOM.
GESCOM/2023-24/EL/WORK_INDENT9
GESCOM/2023-24/EL/WORK_INDENT9
Open
Electrical
Two Tender Document System(Two Cover)
GESCOM SUPERINTENDING ENGINEER CIRCLE OFFICE KOPPALA
4 documents required · 0 mandatory · 4 optional
The bidder should have successfully executed on Total / Partial Turn Key/labour contract/self execution Basis 6.0 Ckt.Kms. of 11KV & above class of lines during the period from FY 2019-20 , 2020-21 & 2021-22 and they must be in successful operation for a period of 12 months as on the date of opening of Techno-Commercial bids. (Enclose certificate about satisfactory completion and successful operation of the line by bidder giving details like name of the work and date of commissioning etc., from the competent authority not below the rank of Executive Engineer/Equivalent cadre
The Bidder should possess valid class-I electrical contractors license issued by Govt. of Karnataka.
The bidder should upload original scanned copy of 1) ESI, 2) EPF Reg. No, 3) Pan No and 4) GST No. issued by the respective competent authorities of the concerned department
The bidder should have achieved annual financial turnover not less than the amount put to tender under this contract in any one year during 5 (Five) financial years i.e, 2018-19, 2019-20 ,2020-21 ,2021-22 and 2022-23. The bidder should upload the Copies of Annual turnover certificate and audited balance sheet, profit and loss account statement duly certified by Chartered Accountant.
The liquid assests should not be older than 60 days as on last date of bid submission consisting of cash at bank plus term deposits in any nationalized / scheduled bank shall not be lesser than 25 percent of of the Amount put to tender the certificate supporting the above shall be issued by the banker duly indicating work indent number and adressing to superintending engineer ele O and M circle GESCOM Koppal OR The credit facility not lesser than 25 percent of Amount put to tender which shall not be older than 60days as on last date of bid submission which shall be supported by a certificate issued by any nationalized, scheduled bank with whom the bidder has banking facilities shall be scan and uploaded. The said originals scanned credit facility certificate should possess the name of the form and tender indent number and the credit facility to be issued in the name of Superintending Engineer Ele O and M Circle GESCOM Koppal. The conditional Credit certificate are laible for rejection.
Department Registration Details
Total value of ELECTRICAL engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing work
List of works for which tenders already submitted
Banker Details
The bidder should upload original scanned copy of Labour Registration Certificate of establishment issued by Department of Labour, Government of Karnataka
The bidder should not have been Black-Listed by ESCOMs/ KPTCL/ any other Government Distribution/ Transmission utilities including PSUs as on date of bid submission. Self-declaration for the same shall be uploaded
The bidder should not have been defaulted/short closed due to non-performance in execution of works against the order placed by ESCOMs/KPTCL/any other Government Distribution/Transmission utilities including PSUs as on date of bid submission. Self-declaration for the same shall be uploaded
Bidder shall have adequate knowledge of the work proposed in the tender, design procedures including quality control and shall have infrastructure and erection facilities and capacity to execute the works. Self-declaration for the same shall be uploaded
₹500
₹18,100
31 Oct 2023
31 Oct 2023
17 Nov 2023
7 Nov 2023
Estimate for bifurcation of load from overloaded F-7 Nelajeri IP set feeder emanating from 110/33/11 Kv MUSS Mangalore by creating NEW IP set feeder from 110/11 Kv Chilakamukhi MUSS at sharanappa Sidaganahalli IP land in O&M Mangalore Section of Yelburga Sub Division. Under partial turnkey basis. Poles and Conductor, DP Structure, GOS with H-frame will be supplied by GESCOM.
Estimate for bifurcation of load from overloaded F-7 Nelajeri IP set feeder emanating from 110/33/11 Kv MUSS Mangalore by creating NEW IP set feeder from 110/11 Kv Chilakamukhi MUSS at sharanappa Sida...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
3_section-ii_(itb) ind no 9.doc
Instructions to Tenderers • 0.10 MB
1_nit ind no 9.doc
Tender Document • 0.11 MB
5_section-iv_(ecc) ind no 9.doc
Others - ECC • 0.09 MB
General terms and conditions.docx
Others - general terms and conditions • 0.06 MB
6_section-v_(scc) ind no 9.doc
Others - SCC • 0.10 MB
4_section-iii_(gcc) ind no 9.doc
Others - GCC • 0.13 MB
Drawings pdf.pdf
Others - DRAWINGS • 1.90 MB
7_volume_vi_annexures_9.doc
Others - ANNEXURES • 0.14 MB
2_section-i_(ifb) ind no 9.doc
Others - IFB • 0.14 MB
BOQ.xls
Others - BOQ • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .