Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC OIL INDIA LTD GATE NO 02 PO UDAYAN VIHAR GUWAHATI ASSAM | KAMRUP METRO | ASSAM | 781001 | L1 | Accepted-AOC Validated (Lowest bidder) | |
| 2 | L2₹37.6 L+₹2.0 L (5.72%)Rejected-Finance | L2 | Rejected-Finance Not validated (Other than lowest bidder) | |
| 3 | L3₹43.9 L+₹8.3 L (23.3%)Rejected-Finance GARH ROAD MEERUT UTTAR PRADESH 250002 INDIA | MEERUT | UTTAR PRADESH | 250002 | L3 | Rejected-Finance Not validated (Other than lowest bidder) | |
| 4 | L4₹45.5 L+₹9.9 L (27.8%)Rejected-Finance HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | L4 | Rejected-Finance Not validated (Other than lowest bidder) | |
| 5 | L5₹54.3 L+₹18.7 L (52.5%)Rejected-Finance HOUSE NO 129 BASISTHA ROAD BASISTHA CHARIALI PO BASISTHA GUWAHATI 781029 ASSAM | KAMRUP METRO | ASSAM | 781029 | L5 | Rejected-Finance Not validated (Other than lowest bidder) |
| Sl No | Description | Qty | Unit | DEEP CONSTRUCTION L6 | PRITHWI BUILDERS L5 | S. R. TRADING L1 | M/S K NATH AND CO. L3 | M/S M.G ENTERPRISE L2 | M/S SEWAK SINGH L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for Stequa PACK PRO V2 Automatic erosion feed enabled water sanitizer / conditioning treatment station with proportional dosing arrangement consisting of: 1) Replacement with following attachments:- a) Station Holding Assembly b) Water Inlet Regulator c) Overflow Vent d) Drain valve e) Fluid Level controller with In-built Level Switch f) Sludge Level Gauge g) Station Base Assembly with Station Base Buffer h) Material of construction: Non-metallic thermoplastic i) Maximum Temperature: 45°C j) Capacity: 100 litres k) Shape: Cylindrical 2) Replacement with following attachments of Station Hood Assembly with multi-cavity arrangement as under:- a) Custom cover b) Refill Cavity Lids c) Electrically powered drive unit with pressure resistance up to 10 Bars d) Maximum Discharge: 100 LPH e) Material of construction: Non-metallic f) Maximum Temperature: 45°C g) Shape: Circular h) Cavity Lids storage bin 3) Automation assembly with accessories Compatibility: Stequa 411 AE Refill including necessary testing and commissioning as directed complete all as specified and as directed. Make: Declibac or equivalent MES approved make. | 4 | Each Set | 2,85,000 ₹11,40,000 | 2,55,000 ₹10,20,000 | 1,00,000 ₹4,00,000 Lowest | 2,12,000 ₹8,48,000 | 1,50,000 ₹6,00,000 | 2,20,000 ₹8,80,000 |
| 2.00 | Supply only plastic cylindrical sealed disposable sanitiser refill containing solid Chlorine for disinfection of drinking water, with arrangement for controlled release of disinfectant in water, suitable for operation through recommended dosing system. Replacement indication: visual & weight variation Water contact orifice design: Sealed when dry, exposed upon immersion Operation type: Non-contact, non-inhalatory Cylinder dia: 2.5 inches ± 0.5 inches Cylinder height: Minimum 10.0 inches ± 0.5 inches complete all as specified and directed. Make: Declibac or equivalent MES approved make | 21 | Each Set of 20 refills | 39,500 ₹8,29,500 | 35,700 ₹7,49,700 | 20,000 ₹4,20,000 Lowest | 35,000 ₹7,35,000 | 25,000 ₹5,25,000 | 32,000 ₹6,72,000 |
| 3.00 | M&L for Testing of Raw water at main pump house and personal PH Following parameters is tested on regular basis from any recogonised Govt lab or authoeised lab and Testing certificate is submitted to GE Guwahati Complete as directed by Engr in charge. General: Colour, Odour, Temperature, pH, Electrical Condductivity (EC), Disolved Oxygen (DO), Turbidity, Total Dissolved Solid (TDS),
Nutrients : NO3, PO4
Demand Parametete: Bio-chemical oxygen Demand (BOD), Chemical Oxygen Demand (COD)
Major ions: Sodium (NA+), Potassium (K+), Calcium (Ca++), Magnesium (Mg++), Carbonate (CO3), Bicarbonate (HCO3), Magnesium (Mg++), Carbonte (CO3), Bicarbonate (HCO3), Chlorie (CL), Sulphate (SO4-),
Other inorganic: Other location specific parameeters
Microbiological: Faecal Coliforms/Thermotolerent coliforms
Metals: s,Cd,Hg,Zn,Cr,Pb,Ni,Fe,Mn, Ag, Cu,Se. Raw water at the intake point/Jack well for surface water sources at the Once a year complete all as specified and directed. | 1 | Each job | 11,200 ₹11,200 | 9,180 ₹9,180 | 9,000 ₹9,000 | 7,000 ₹7,000 Lowest | 7,000 ₹7,000 Lowest | 8,500 ₹8,500 |
| 4.00 | M&L for Testing of Raw water at main pump house and personal PH Following parameters is tested on regular basis from any recogonised Govt lab or authoeised lab and Testing certificate is submitted to GE Guwahati Complete as directed by Engr in charge.
General: Colour, Odour, Temperature, pH, Electrical Condductivity (EC), Disolved Oxygen (DO), Turbidity, Total Dissolved Solid (TDS),
Nutrients : NO3
Demand Parametete: Bio-chemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD)
Major ions: Sodium (NA+), Potassium (K+), Calcium (Ca++), Magnesium (Mg++), Carbonate (CO3), Bicarbonate (HCO3), Chloride (Cl), Sulphate (SO4-).
Other inorganic: Other location specific parameters
Microbiological: Faecal Coliforms/Thermotolerent coliforms Quarterly sampling complete all as specified and directed. | 2 | Each Job | 9,850 ₹19,700 | 9,180 ₹18,360 | 8,000 ₹16,000 | 7,000 ₹14,000 Lowest | 7,000 ₹14,000 Lowest | 7,500 ₹15,000 |
| 5.00 | M&L for Testing of Treated water at main pump house and personal PH Following parameters is tested on regular basis from any recogonised Govt lab or authoeised lab and Testing certificate is submitted to GE Guwahati Complete as directed by Engr in charge. General: Colour, Odour, Temperature, pH, Electrical Condductivity (EC), Disolved Oxygen (DO), Turbidity, Total Dissolved Solid (TDS),
Nutrients : NO3, PO4
Demand Parametete: Bio-chemical oxygen Demand (BOD), Chemical Oxygen Demand (COD)
Major ions: Sodium (NA+), Potassium (K+), Calcium (Ca++), Magnesium (Mg++), Carbonate (CO3), Bicarbonate (HCO3), Magnesium (Mg++), Carbonte (CO3), Bicarbonate (HCO3), Chlorie (CL), Sulphate (SO4-),
Other inorganic: Other location specific parameeters
Microbiological: Faecal Coliforms/Thermotolerent coliforms
Metals: s,Cd,Hg,Zn,Cr,Pb,Ni,Fe,Mn, Ag, Cu,Se. water samples are to be collected from water teatment plant and at various point within the distribution system, including at the consumer end at the Once a year complete all as specified and directed. | 1 | Each job | 9,850 ₹9,850 | 9,180 ₹9,180 | 9,000 ₹9,000 | 7,000 ₹7,000 Lowest | 7,000 ₹7,000 Lowest | 7,500 ₹7,500 |
| 6.00 | M&L for Testing of Treated water at main pump house and personal PH Following parameters is tested on regular basis from any recogonised Govt lab or authoeised lab and Testing certificate is submitted to GE Guwahati Complete as directed by Engr in charge.
General: Colour, Odour, Temperature, pH, Electrical Condductivity (EC), Disolved Oxygen (DO), Turbidity, Total Dissolved Solid (TDS),
Nutrients : NO3
Demand Parametete: Bio-chemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD)
Major ions: Sodium (NA+), Potassium (K+), Calcium (Ca++), Magnesium (Mg++), Carbonate (CO3), Bicarbonate (HCO3), Chloride (Cl), Sulphate (SO4-).
Other inorganic: Other location specific parameters
Microbiological: Faecal Coliforms/Thermotolerent coliforms. water samples are to be collected from water teatment plant and at various point within the distribution system, including at the consumer end Quarterly sampling complete all as specified and directed. | 2 | Each job | 9,850 ₹19,700 | 9,180 ₹18,360 | 8,000 ₹16,000 | 7,000 ₹14,000 Lowest | 7,000 ₹14,000 Lowest | 7,500 ₹15,000 |
| 7.00 | M&L for complete removal of old existing filter media (sand,silex and pebbles) from filtration plant of personal pump house and throughly cleaning, washing the inner surface of filtarion bed and PVC pipe line (lateral and header pipes) by removing all dust particles by means of soda, bleaching powder etc by using steel wire brushes or steel scrapers comple all as specified and as directed. | 1 | Each Job | 9,850 ₹9,850 | 9,180 ₹9,180 | 5,000 ₹5,000 Lowest | 6,500 ₹6,500 | 7,000 ₹7,000 | 7,500 ₹7,500 |
| 8.00 | Material and labour for filter media Sand of size 0.45mm to 0.70mm spreading in layers size wise with filter media as per sample approved by GE complete all as specified and as directed. | 0.8 | Cum | 4,850 ₹3,880 | 4,080 ₹3,264 | 8,000 ₹6,400 | 3,000 ₹2,400 | 2,000 ₹1,600 Lowest | 3,500 ₹2,800 |
| 9.00 | Material and labour for filter media of Fine silex of size 1mm to 2mm spreading in layers size wise with filter media as per sample approved by GE complete all as specified and as directed. | 0.5 | Cum | 4,750 ₹2,375 | 4,080 ₹2,040 | 800 ₹400 Lowest | 3,000 ₹1,500 | 2,000 ₹1,000 | 3,500 ₹1,750 |
| 10.00 | Material and labour for filter media of Coarse silex of size 3mm to 4mm spreading in layers size wise with filter media as per sample approved by GE complete all as specified and as directed. | 0.5 | Cum | 4,650 ₹2,325 | 4,080 ₹2,040 | 800 ₹400 Lowest | 3,000 ₹1,500 | 2,000 ₹1,000 | 3,500 ₹1,750 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
17 Feb 2026, 6:00 pmClosed
GE GUWAHATI
GE GUWAHATI, PO SATGAON, DISTT KAMRUP - 781027
REPAIR MAINT OF CHLORINATION PLANTS, ELECTRICAL PANELS, VALVES AND VALVE PITS AND CONNECTED ITEMS IN ALL PUMP HOUSE AND REPAIR/REPLACEMENT OF INTERNAL WIRING WITH FITTING FIXTURES AT OTM ACCN BASISTHA UNDER GE GUWAHATI
2026_MES_750096_1
8594/E8
Open Tender
Civil Works
Item Rate
180 days
GUWAHATI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE GUWAHATI
₹80,000
Yes
6 Mar 2026
27 Jan 2026
19 Feb 2026
27 Jan 2026
17 Feb 2026
10 Feb 2026
27 Jan 2026 - 3 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for Stequa PACK PRO V2 Automatic erosion feed enabled water sanitizer / conditioning treatment station with proportional dosing arrangement consisting of: 1) Replacement with following attachments:- a) Station Holding Assembly b) Water Inlet Regulator c) Overflow Vent d) Drain valve e) Fluid Level controller with In-built Level Switch f) Sludge Level Gauge g) Station Base Assembly with Station Base Buffer h) Material of construction: Non-metallic thermoplastic i) Maximum Temperature: 45°C j) Capacity: 100 litres k) Shape: Cylindrical 2) Replacement with following attachments of Station Hood Assembly with multi-cavity arrangement as under:- a) Custom cover b) Refill Cavity Lids c) Electrically powered drive unit with pressure resistance up to 10 Bars d) Maximum Discharge: 100 LPH e) Material of construction: Non-metallic f) Maximum Temperature: 45°C g) Shape: Circular h) Cavity Lids storage bin 3) Automation assembly with accessories Compatibility: Stequa 411 AE Refill including necessary testing and commissioning as directed complete all as specified and as directed. Make: Declibac or equivalent MES approved make. | 4 | Each Set | - | - |
| - | Supply only plastic cylindrical sealed disposable sanitiser refill containing solid Chlorine for disinfection of drinking water, with arrangement for controlled release of disinfectant in water, suitable for operation through recommended dosing system. Replacement indication: visual & weight variation Water contact orifice design: Sealed when dry, exposed upon immersion Operation type: Non-contact, non-inhalatory Cylinder dia: 2.5 inches ± 0.5 inches Cylinder height: Minimum 10.0 inches ± 0.5 inches complete all as specified and directed. Make: Declibac or equivalent MES approved make | 21 | Each Set of 20 refills | - | - |
| - | M&L for Testing of Raw water at main pump house and personal PH Following parameters is tested on regular basis from any recogonised Govt lab or authoeised lab and Testing certificate is submitted to GE Guwahati Complete as directed by Engr in charge. General: Colour, Odour, Temperature, pH, Electrical Condductivity (EC), Disolved Oxygen (DO), Turbidity, Total Dissolved Solid (TDS),
Nutrients : NO3, PO4
Demand Parametete: Bio-chemical oxygen Demand (BOD), Chemical Oxygen Demand (COD)
Major ions: Sodium (NA+), Potassium (K+), Calcium (Ca++), Magnesium (Mg++), Carbonate (CO3), Bicarbonate (HCO3), Magnesium (Mg++), Carbonte (CO3), Bicarbonate (HCO3), Chlorie (CL), Sulphate (SO4-),
Other inorganic: Other location specific parameeters
Microbiological: Faecal Coliforms/Thermotolerent coliforms
Metals: s,Cd,Hg,Zn,Cr,Pb,Ni,Fe,Mn, Ag, Cu,Se. Raw water at the intake point/Jack well for surface water sources at the Once a year complete all as specified and directed. | 1 | Each job | - | - |
| - | M&L for Testing of Raw water at main pump house and personal PH Following parameters is tested on regular basis from any recogonised Govt lab or authoeised lab and Testing certificate is submitted to GE Guwahati Complete as directed by Engr in charge.
General: Colour, Odour, Temperature, pH, Electrical Condductivity (EC), Disolved Oxygen (DO), Turbidity, Total Dissolved Solid (TDS),
Nutrients : NO3
Demand Parametete: Bio-chemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD)
Major ions: Sodium (NA+), Potassium (K+), Calcium (Ca++), Magnesium (Mg++), Carbonate (CO3), Bicarbonate (HCO3), Chloride (Cl), Sulphate (SO4-).
Other inorganic: Other location specific parameters
Microbiological: Faecal Coliforms/Thermotolerent coliforms Quarterly sampling complete all as specified and directed. | 2 | Each Job | - | - |
| - | M&L for Testing of Treated water at main pump house and personal PH Following parameters is tested on regular basis from any recogonised Govt lab or authoeised lab and Testing certificate is submitted to GE Guwahati Complete as directed by Engr in charge. General: Colour, Odour, Temperature, pH, Electrical Condductivity (EC), Disolved Oxygen (DO), Turbidity, Total Dissolved Solid (TDS),
Nutrients : NO3, PO4
Demand Parametete: Bio-chemical oxygen Demand (BOD), Chemical Oxygen Demand (COD)
Major ions: Sodium (NA+), Potassium (K+), Calcium (Ca++), Magnesium (Mg++), Carbonate (CO3), Bicarbonate (HCO3), Magnesium (Mg++), Carbonte (CO3), Bicarbonate (HCO3), Chlorie (CL), Sulphate (SO4-),
Other inorganic: Other location specific parameeters
Microbiological: Faecal Coliforms/Thermotolerent coliforms
Metals: s,Cd,Hg,Zn,Cr,Pb,Ni,Fe,Mn, Ag, Cu,Se. water samples are to be collected from water teatment plant and at various point within the distribution system, including at the consumer end at the Once a year complete all as specified and directed. | 1 | Each job | - | - |
| - | M&L for Testing of Treated water at main pump house and personal PH Following parameters is tested on regular basis from any recogonised Govt lab or authoeised lab and Testing certificate is submitted to GE Guwahati Complete as directed by Engr in charge.
General: Colour, Odour, Temperature, pH, Electrical Condductivity (EC), Disolved Oxygen (DO), Turbidity, Total Dissolved Solid (TDS),
Nutrients : NO3
Demand Parametete: Bio-chemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD)
Major ions: Sodium (NA+), Potassium (K+), Calcium (Ca++), Magnesium (Mg++), Carbonate (CO3), Bicarbonate (HCO3), Chloride (Cl), Sulphate (SO4-).
Other inorganic: Other location specific parameters
Microbiological: Faecal Coliforms/Thermotolerent coliforms. water samples are to be collected from water teatment plant and at various point within the distribution system, including at the consumer end Quarterly sampling complete all as specified and directed. | 2 | Each job | - | - |
| - | M&L for complete removal of old existing filter media (sand,silex and pebbles) from filtration plant of personal pump house and throughly cleaning, washing the inner surface of filtarion bed and PVC pipe line (lateral and header pipes) by removing all dust particles by means of soda, bleaching powder etc by using steel wire brushes or steel scrapers comple all as specified and as directed. | 1 | Each Job | - | - |
| - | Material and labour for filter media Sand of size 0.45mm to 0.70mm spreading in layers size wise with filter media as per sample approved by GE complete all as specified and as directed. | 0.8 | Cum | - | - |
| - | Material and labour for filter media of Fine silex of size 1mm to 2mm spreading in layers size wise with filter media as per sample approved by GE complete all as specified and as directed. | 0.5 | Cum | - | - |
| - | Material and labour for filter media of Coarse silex of size 3mm to 4mm spreading in layers size wise with filter media as per sample approved by GE complete all as specified and as directed. | 0.5 | Cum | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
8594Tender.pdf
Tender Documents • 0.66 MB
BOQ_840099.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .