| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest bid. | |
| 2 | L2₹15.5 L+₹57,184 (3.82%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bid. | |
| 3 | L3₹17.1 L+₹2.2 L (14.6%)Rejected-Finance H NO B III 95 MOHALLA GHARTHOLI MISSION ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Other than lowest bid. | |
| 4 | L4₹17.6 L+₹2.7 L (17.9%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bid. | |
| 5 | L5₹18.5 L+₹3.5 L (23.7%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bid. |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
19 Sept 2022, 6:00 pmClosed
GE SOUTH MAMUN
GE SOUTH MAMUN PATHANKOT-145001
REPAIR AND REPLACEMENT OF SECURITY LIGHT, LED FLOOD LIGHT ALONGWITH DAMAGED LT CABLES AND ITS CONNECTED ITEMS AT D-II ZONE AND CBS GHAROTA AREA UNDER GE (S) MAMUN
2022_MES_547221_1
GE(S)/M-18/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE SOUTH MAMUN
AS PER NIT
8 documents required · 8 mandatory
₹500
GE SOUTH MAMUN
₹38,000
Yes
13 Oct 2022
24 Aug 2022
26 Sept 2022
24 Aug 2022
19 Sept 2022
7 Sept 2022
Amount
S&F as in replacement of surge protection device after taking down street light, ISI approved company made as per existing make and size, suitable for LED fittings of capacity upto 150watts anny type and make and refixed the same complete all as specified and directed.
Supply and fixing "as in repair" GI bracket for street light fitting made out of 40mm dia GI pipe light grade 1.2 mtr long each bent to required shape & size as directed by EIC & fixed to pole with and including flat iron clamps 02 Nos made out of 32X 6mm flat iron including GI nuts, bolts &washer and painting of clamps and street light firtting bracket with one coat of red oxide primer, one under coat and one finishing coat with aluminium paint complete all as specified and directed.
Supply and fixing "as in repair" GI bracket for street light fitting made out of 25mm dia GI pipe light grade 1.2 mtr long each bent to required shape & size as directed by EIC & fixed to pole with and including flat iron clamps 02 Nos made out of 32X 6mm flat iron including GI nuts, bolts &washer and painting of clamps and street light firtting bracket with one coat of red oxide primer, one under coat and one finishing coat with aluminium paint complete all as specified and directed.
Supply and fixing as in repair of post top lantern 40 watts 230 volts, 50 Hz mushroom or oval shaped in sothing opal/prismatic finish made up of polycarbonate, suitable for 40 Watt LED, including all accessories, prewired The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Supply and fixing as in repair of 45W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Supply and fixing as in repair of 60W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Supply and fixing as in repair of 70/72W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Note for srl item No 4 to 7 above 1. Driver shall be potted anti-vibration types. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be provided. 3. CRI (Colour Rendering Index) of fixture shall be > 70. 4. CCT (Colour Co-related Temperature of fixture shall be 5700K + 300 K. 5. System Lumen Efficacy shall be > 100 Lm/W. 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. 2 years guarantee shall be provided by contractor supported by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type. 10. The defect liability period of LED light shall be 05 years from the certified date of completion & the contractor shall replace/repair the defective fitting within 07 days after handing over to contractor for replacement/repair. 11. CA No. shall be written on each fitting before installation. 12. The name of manufacturer to be embossed on the fitting. 13. The fittings shall have arrangement so that maintenance required, if any can be carried out from top cover.
Supply and fixing in replacement of old unserviceable copper conductor cable three core PVC insulated and sheathed copper conductor cable of size 1.5 sqmm down through the existing pole/GI pipe bracket complete all as specified and directed.
S&F in replacement cable of size 10 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminiun conductor, served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm suspended with galavnised steel wire, complete all as specified and directed.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated PVC sheathed, armoured heavy duty electric cable , with aluminium conductor of size 16 Sqmm x 2 core complete all as specified and directed. Note:- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
All as per srl item No 11 here-in-before, but cable of size 16 Sqmm x 4 core complete all as specified and directed.
All as per srl item No 11 here-in-before, but cable of size 25 Sqmm x 3.5 core complete all as specified and directed.
All as per srl item No 11 here-in-before, but cable of size 50 Sqmm x 3.5 core complete all as specified and directed.
All as per srl item No 11 here-in-before, but cable of size 95 Sqmm x 3.5 core complete all as specified and directed.
Excavating in trenches in any type of soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out complete all as specified and directed.
Excavating in trenches in any type of soil, n. exc. 1.5 m wide and exc. 1.5 m but n. exc. 3 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and getting out complete all as specified and directed.
Removing excavated material (soil) n.exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
M&L for dry clean fine river sand as in sand cushioning to underground cable 8cm below and 15cm above the cable including punning down of sand layer complete all as specified and directed. Note :- Punned thickness shall only be measured and paid.
M&L for brick protection with sub class 'B' old size brick well burnt laid flat for cable protection abutting each other laid dry with width equal to length of brick complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. Note:- Volume of pole/strut shall be deducted for the purpose of payment.
M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in pedestal/coping including necessary weathering and form work etc complete all as specified and directed. Note:- Volume of pole/strut shall be deducted for the purpose of payment.
Supply and fixing in replacement GI tubing light grade 40 mm bore cut to size and fixed along the pole for cable protection including clamp 02 Nos of size 25x4 mm, nut bolts , washers etc complete all as specified and directed.
Supply and fixing in replacement GI tubing light grade 80 mm bore cut to size and fixed along the pole for cable protection including clamp 02 Nos of size 25x4 mm, nut bolts , washers etc complete all as specified and directed.
Supply and fixing in replacement MCB single pole 240 volts, C series, any rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
Supplying, jointing and connecting "as in repairs" cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting "as in repairs" cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 70 sqmm to 120 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting "as in repairs" cable straight through joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting "as in repairs" cable straight through joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 70 sqmm to 95 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
S&F in replacement optimum adjustable range MCCB FP 415 volts, IEC 60947-II 63 Amps rating with rupturing capacity 25 KA including providing thimble for out going cables and taking out unserviceable MCCB FP of any deccription / type etc. complete from LT Panel, complete all as specified and directed.
S&F in replacement optimum adjustable range MCCB FP 415 volts, 100 Amps rating with rupturing capacity 25 KA including providing thimble for out going cables and taking out unserviceable MCCB FP of any deccription / type etc. complete from LT Panel, complete all as specified and directed.
S&F in replacement electronic LED street light driver ISI marked as approved suitable for LED fittings of cap upto 60 watts any type and make, after taking down the street light and refixing the same complete all as specified and directed.
S&F in replacement electronic LED security light driver ISI marked as approved suitable for LED fittings of cap 60 to 120 watts any type and make, after taking down the street light and refixing the same complete all as specified and directed.
M&L for scraping of old paint from the steel tubular pole 9 Mtr height with out removing accessories, preparation of surfaces repainting the pole with one coat of alternative green and white strips of 30cm each upto 1.5 Mtr height using synthetic enamel paint. Marking the pole number with black enamel paint over yellow circle of dia 100mm. Repainting the remaining pole and iron parts i.e 'U' clamps, channels etc above 1.5 mtr height by applying one coat of alumnium paint, complete all as specified and directed.
M&L for painting of PCC pole 11 mtr height without removing accessories with one coat of alternative green and white strips of 30cm each upto 1.5 Mtr height using synthetic enamell paint . marking the pole number with black synthetic enamel paint over yellow circle of dia 100mm. Painting the steel parts i.e clamps, channels etc by applying one coat of alumnium paint all as required at site, complete all as specified and directed.
Dismantling PCC or steel pole and demolition of PCC, including necessary earth work complete all as specified and directed.
Supply and erecting "as in replacement" of broken pole with prestressed concrete pole 9m long, of size 102mmx172mm at top and 102mmx279mm at bottom, class 10, including zebra painting to PCC poles up to 1.5m height from base of poles with two coats of synthetic enamel paint Ist quality black & yellow colour alternate strips 30cm wide. complete all as specified and directed. Note:- (i) Excavation and earth work and concrete in foundation and pedestal shall be measured and paid for separately. (ii) Rate quoted shall include for disposing off the broken pole ouside the MoD land.
Supply and erecting "as in replacement" in true vertical position steel tubular swaged poles of 9 metres long, type 410 SP-31 complete with cast iron base plate, goose neck bracket, finial taper plug , bolt, nuts & screws as specified and painting internal surface with anti-corrosive paint and external surface painting up to 1.5 m height from base of poles with two coats of synthetic enamel paint Ist quality black & yellow colour alternate strip 30 cm wide over a coat of red oxide primer and remaing portion with two coats of aluminum paint over a coat of red oxide primer, complete all as specified and directed. Note:-Excavation and earth work and concrete in foundation and pedestal shall be measured and paid for separately.
M&L in replacement for stay assembly comprising stay 14 mm dia and 40 cm long stay rod 20 mm dia and 1.8 m long threaded ends with nuts, mild steel plate 30 cm X 30 cm X 6 mm thick and two number of thimble etc. complete with accessories as shown in electrical plate No. 1 of SSR Part-I of 2009 including taking down existing stay assembly complete all as specified and directed. Note:- Loop type insulator, stay clamps, excavation & earh work and concrete shall be measured and paid separately.
M&L for galvanized steel stay wire size 7/ 4.0 mm for stay of poles complete all as specified and directed.
M&L for loop type insulator vitreous, poecelain, white/brown/green, large size, with overall dimensions 65 x90 mm, clearance of hole 16 mm complete all as specified and directed.
S&F as in repalcement of industrial switchgear busbar chambers of 200Amp, 6 way for LT cable any size including necessary PCC/Wall mounting work, cable gland, complete all as specified and directed.
S&F as in replacement digital display astronomical time switch to control various lighting loads according to sunrise and sunset time of current cap rating 16 A AC1 with USB key, 1 change over including backup of 6 year and use of USB key for program download and upload daily, weekly, program complete all as specified and directed.
Supply and fixing in replacement contactor four pole 63 Amps with operating coil voltage 230V with manual operation knob in case of coil failure conforming to cat Part No ETC 463, including suitable size and capacity copper cable and making necessary connections using appropriate copper bus bar or PVC insulated cable with copper conductor and lugs as requiared at site complete all as specified and directed.
S&F as in repalcement danger notice plate factory made of 1.6mm thick mild steel sheet, vitreous enamelled white duly writing, 1100 volt electric line with letters/figures of appropriate size and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed.
M&L for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 25x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetable soil to the remaining 10%,removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed by Engr-In-Charge. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Trimming up of Bushes/ Tree branches all around overhead lines from D-II area and CBS Gharota removing cut branches from site complete all as specified and directed. Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches upto 5 mtr all around the line. Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department. (ii) only effected Span at site shall be measured where tree branches are touching nearly HT/LT lines complete all as specified and directed.
Ashoka Engineers
M/S HIMANSHU BUILDERS
M/S MULTI ENGINEERS
dinesh enterprises
RD Engineers
Bidder Name
Ashoka Engineers
RD Engineers
dinesh enterprises
M/S HIMANSHU BUILDERS
M/S MULTI ENGINEERS
M/S BR ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .