Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹92.5 LAccepted-AOC 322 AGGARWAL MODERN BAZAR C 33 LAWRENCE ROADS DELHI 110035 | DELHI | NORTH WEST DELHI | DELHI | 110035 | ₹92.5 L | L-1 | Accepted-AOC ok |
| Sl No | Description | Qty | Unit | M/s KRP Engineering Pvt. Ltd. L1 |
|---|---|---|---|---|
| 1.00 | Supply, erection and commissioning of 10Cs. V.T. Axial flow Pump having lift 25±1ft, around 980 RPM, Including MS delivery of 8 mm thickness (approx length - 70 feet each) & bend complete in all respect as per site requirement & specification approved by technical committee (Annexure - A). | 2 | No. | 19,85,000 ₹39.7 L |
| 2.00 | Supply, erection and commissioning of induction motor of 60 HP suitable for 10 Cs VT axial flow pump (mentioned at Sr no. 01), 45 KW, 980 RPM, 415V, 3 phase, 50 Hz bearing SKF /FAG, IE-2 as per specifications and site requirements (Annexure - B). | 2 | No. | 5,92,000 ₹11.8 L |
| 3.00 | Supply, erection and commissioning of 05Cs. V.T. Axial flow Pump having lift 25±1ft, 1440 RPM Including MS delivery of 8 mm thickness (approx length - 70 feet each) & bend complete in all respect as per site requirement & specification approved by technical committee (Annexure - A). | 1 | No. | 12,60,000 ₹12.6 L |
| 4.00 | Supply, erection and commissioning of induction motor of 40 HP, 1440 RPM, suitable for 05 Cs VT axial flow pump (mentioned at Sr no. 03), 30 KW, 415V, 3 phase, 50 Hz bearing SKF /FAG, IE-2 as per specifications and site requirements (Annexure - B). | 1 | No. | 3,45,000 ₹3.5 L |
| 5.00 | Supply, errection and commissioning of LT Panel as per IP-54 with 01no incomer ACB 600 Amp 4 pole, 01no voltmeter, 01no ammeter and 03Nos. outgoings/bus bars so that it can be connected to 03No ATS starters with stand of MS Channel/angle (1 feet height from floor level) as per approved specification (as per Annexure-C) | 1 | No. | 14,35,000 ₹14.3 L |
| 6.00 | Supply of 70HP fully Automatic ATS Starter 415 V, 50 Hz with contractors of 120A/80A/60A for 60HP motor with minimum incomer MCCB 200amp, meters, relays, indicators complete in all respect with degree of protection IP-55 and with canopy including connection and small item like thimble, nut bolts, lugs etc with stand of MS angle 50x50x6 mm of 1 feet height from floor level and with allied accessories as per makes and specification.(as per Annexure-C) | 2 | No. | 4,55,000 ₹9.1 L |
| 7.00 | Supply of 50HP fully Automatic ATS Starter 415 V, 50 Hz with contractors of 80A/52A/52A for 40HP motor with minimum incomer MCCB 125amp, meters, relays, indicators complete in all respect with degree of protection IP-55 and with canopy including connection and small item like thimble, nut bolts, lugs etc with stand of MS angle 50x50x6 mm of 1 feet height from floor level and with allied accessories as per makes and specification.(as per Annexure-C) | 1 | No. | 3,85,000 ₹3.9 L |
| 8.00 | Supply, errection and commissioning of LT cable 3.5 core - 300 Sq mm Aluminium Conductor, XLPE insulated, Armored cable from Transformer to Motor Control Centre. | 70 | Mtr. | 4,200 ₹2.9 L |
| 9.00 | Supply, errection and commissioning of LT cable 3 core - 35 Sq mm Copper Conductor, XLPE insulated, Starter to Motor & incomer to starter. | 80 | Mtr. | 440 ₹35,200 |
| 10.00 | Providing and fixing of chemical earthing by digging 200 mm bore, 10 ft depth complete with copper electrode, copper strip for MCC panel complete in all respect as per site requirement | 1 | No. | 1,75,000 ₹1.8 L |
Updated dates
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
2 Feb 2026, 1:00 pmClosed
Executive Engineer, W.S. Mech. Division, Rewari
Executive Engineer, W.S. Mech. Division, Rewari
Supply, erection and commissioning of 02 No - 10Cs and 1 No. 5Cs AFVT Pumps along with motors and 01 no. MCC/ LT Panel at Rajpura Khalsa Flood Pump House
2026_HRY_498941_1
285/6-A dated 22.01.2026
Open Tender
Electrical Work/ Equipment
150 days
Executive Engineer, W.S. Mech. Division
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
₹1.7 L
29 Apr 2026
24 Jan 2026
2 Feb 2026
24 Jan 2026
2 Feb 2026
24 Jan 2026
Supply, erection and commissioning of 10Cs. V.T. Axial flow Pump having lift 25±1ft, around 980 RPM, Including MS delivery of 8 mm thickness (approx length - 70 feet each) & bend complete in all respect as per site requirement & specification approved by technical committee (Annexure - A).
Supply, erection and commissioning of induction motor of 60 HP suitable for 10 Cs VT axial flow pump (mentioned at Sr no. 01), 45 KW, 980 RPM, 415V, 3 phase, 50 Hz bearing SKF /FAG, IE-2 as per specifications and site requirements (Annexure - B).
Supply, erection and commissioning of 05Cs. V.T. Axial flow Pump having lift 25±1ft, 1440 RPM Including MS delivery of 8 mm thickness (approx length - 70 feet each) & bend complete in all respect as per site requirement & specification approved by technical committee (Annexure - A).
Supply, erection and commissioning of induction motor of 40 HP, 1440 RPM, suitable for 05 Cs VT axial flow pump (mentioned at Sr no. 03), 30 KW, 415V, 3 phase, 50 Hz bearing SKF /FAG, IE-2 as per specifications and site requirements (Annexure - B).
Supply, errection and commissioning of LT Panel as per IP-54 with 01no incomer ACB 600 Amp 4 pole, 01no voltmeter, 01no ammeter and 03Nos. outgoings/bus bars so that it can be connected to 03No ATS starters with stand of MS Channel/angle (1 feet height from floor level) as per approved specification (as per Annexure-C)
Supply of 70HP fully Automatic ATS Starter 415 V, 50 Hz with contractors of 120A/80A/60A for 60HP motor with minimum incomer MCCB 200amp, meters, relays, indicators complete in all respect with degree of protection IP-55 and with canopy including connection and small item like thimble, nut bolts, lugs etc with stand of MS angle 50x50x6 mm of 1 feet height from floor level and with allied accessories as per makes and specification.(as per Annexure-C)
Supply of 50HP fully Automatic ATS Starter 415 V, 50 Hz with contractors of 80A/52A/52A for 40HP motor with minimum incomer MCCB 125amp, meters, relays, indicators complete in all respect with degree of protection IP-55 and with canopy including connection and small item like thimble, nut bolts, lugs etc with stand of MS angle 50x50x6 mm of 1 feet height from floor level and with allied accessories as per makes and specification.(as per Annexure-C)
Supply, errection and commissioning of LT cable 3.5 core - 300 Sq mm Aluminium Conductor, XLPE insulated, Armored cable from Transformer to Motor Control Centre.
Supply, errection and commissioning of LT cable 3 core - 35 Sq mm Copper Conductor, XLPE insulated, Starter to Motor & incomer to starter.
Providing and fixing of chemical earthing by digging 200 mm bore, 10 ft depth complete with copper electrode, copper strip for MCC panel complete in all respect as per site requirement
The above rates are inclusive of all kind of taxes including GST and other expences like F.O.R. destination and inclusive of all incidental charges, enroute & at destination. Nothing extra shall be paid separately. Terms & Conditions as mentioned in Bid document in Price Schedule.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.37 MB
BOQ_577510.xls
BOQ • 0.30 MB
Untitled.pdf
Other Document • 4.69 MB
Download all tender documents and submit your bid