| 1 | L1₹5.4 LAccepted-AOC T 3 HILL CREST APARTMENT BEHIND AMBABAI TEMPLE VASCO DA GAMA GOA 403 802 | VASCO DA GAMA | SOUTH GOA | GOA | 403802 | ₹5.4 L Quoted ₹6.0 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹6.3 L+₹28,705 (4.78%)Rejected-Finance | ₹6.3 L+₹28,705 (4.78%) | L2 | Rejected-Finance BEING NOT L1 |
| 3 | L3₹6.4 L+₹44,255 (7.37%)Rejected-Finance | ₹6.4 L+₹44,255 (7.37%) | L3 | Rejected-Finance BEING NOT L1 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not fulfill NIT criteria |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
21 Dec 2020, 6:00 pmClosed
Garrison Engineer (I) (CG) Goa
Garrison Engineer (I) (CG) Goa HQ Coast Guard DHQ-11 Chicolna PO- Bogmalo Goa 403806
REPAIR MAINTENANCE OF INTERNAL ELECTRIFICATION AT TECHNICAL AREA COAST GUARD BUILDINGS UNDER GE (I) (CG) GOA
2020_MES_396231_1
8153/GOA/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Tech area Hansa South Goa
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer (I) (CG) Goa
₹14,000
Yes
6 Mar 2021
18 Nov 2020
24 Dec 2020
18 Nov 2020
21 Dec 2020
5 Dec 2020
18 Nov 2020 - 26 Nov 2020
Amount
Taking down aluminium/copper point wiring (light, fan, socket or power) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials for taking credit (credit for above items should be made as per conditions seperately) and making good the disturbed surface complete all as specified and directed.
Taking down unserviceable high bay/Flood/Hanger/ any type of light fitting from hangar upto 18 mtr height and refixing after replacement of new spares like Ballasts, Ignitor, capacitor, lamp & holders ,. etc and refix the same after repair work in the existing place incl replacement of minor spares which is not covered under this schedule complete all as specified and directed. Note: New Spares will be measured & paid seperately under respective item of 31,32,33,35.
M&L point wiring complete with 1100 volt grade PVC insulated unsheathed multistranded 1.5 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC casing and capping medium grade of size 25/20 mm, etc fixed on wall/ceiling including provision of 1.5 sqmm PVC unsheathed copper conductor and connected to earth dolly, including provision of pressed steel terminal box with 3mm thick plastic laminated sheet top cover for housing switches sockets etc concealed on wall testing complete all as specified and directed.
One light point controlled by one switch
One call bell point controlled by bell push
One fan/exhaust fan point controlled by one switch & regulator
One 5 Amps socket on independent board
One light point controlled by two, two way switches.
All as per item No 3 above but one power point complete with 2.5 sqmm copper cable drawn through and incl casing and capping of suitable size and one run of 1.5 sqmm copper cable of upto earth dolly earthing for 15 Amps socket outlet independent including testing complete all as specified and directed.
S & F switch piano, flush type single pole, one way 5 Amp complete all as specified and directed.
S & F switch piano, flush type single pole, two way 5 Amp complete all as specified and directed.
S & F switch socket combination 2 in 1, 5 pin, 6 Amp flush type complete all as specified and directed.
S & F switch socket combination 2 in 1, 5 pin 15 amp flush type universal complete all as specified and directed.
S & F industrial socket with single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 25 Amp complete all as specified and directed.
S & F ceiling rose 3 terminal, 230 volts, PVC polycarbonate, isolated body complete all as specified and directed.
S&F call bell ding dong, AC, 230 volts, single phase, 50 HZ complete all as specified and directed.
S & F bell push 5 Amp flush type complete as per code 95133 complete all as specified and directed.
S & F stepped type electronic fan regulator 230 V, 5 Step complete all as specified and directed.
S&F lamp holder angle / battern type, insulated body complete all as specified and directed.
M & L sub main wiring with two runs of single core 4 Sqmm FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & incl PVC casing caping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 4 Sqmm single core FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc including taking down the old unservicible one complete all as specified and directed. (Note :- Two runs of cable, one run of earth continuity conductor and one run of PVC casing caping/conduit shall be measured as one unit)
All as per item No 15 here in before, but 4 run of single core 6 sqmm and two run of 6 sqmm cables as earth continuity conductor including taking down the old unservicible one complete all as specified and directed.
S&F in repairs MCB DB SPN, double door, 8 ways complete all as specified and directed.
S&F in repairs MCB DB TPN, double door, 4 way, 415 volts complete all as specified and directed.
S&F in repairs MCB TPN, 'C' series, 63 Amp, 415 volts, 50 Hz, 10 KA complete all as specified and directed
S&F in repairs MCB, SP, 'C' series, 06 to 32 Amp, 230 volts, complete all as specified and directed.
S&F in repairs, MCB, SPN, 06 to 32 Amp, 230 volts, complete all as specified and directed.
S & F in repairs for RCCB , DP, 25 Amp, 100 mA, 230 volts, 50 HZ, 10 KA breaking capacity complete all as specified and directed.
S & F in repairs LED tube light fitting 1 x 18 W, 230V wall mounted integrated batten, 4 ft LED module shall confirm to IS 16103 and shall bear BIS certification marking complete with all accessories internally pre- wired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and directed.
Supply and fix in repairs LED lamp 9W, 230V, insulated body, with back plate for batten fitting complete all as specified and directed.
Supply and fix LED in repairs security light luminaire 1 x 36 W with pressure die cast aluminium housing, heat resistant glass, IP 65 protection & better optics for uniform distribution including fixing bracket made of GI tubing medium grade 40 mm dia, 1.5 mtr long with flat iron clamps, nuts, Bolts, washers etc and connecting up from ceiling rose using 3 core 1.5 sqmm flexible copper conductor cable complete all as specified and directed.
S & F in repairs LED Backlit panel 36W '2x2 ' recess mounting luminaire suitable for armstrong/grid/ Pop ceiling complete with separate electronic driver & high brighteness SMD Leds complete all as specified and directed.
Supply and fixing in repairs 400W integrated industrial highbay luminaires with diecast aluminium control gear housing & spun anodised aluminium reflector, anodized Aluminum narrow beam reflector ( closed version ) complete with copper ballast, capacitor, glass and all accessories including 400W MH lamp complete all as specified and directed including taking down old fitting complete all as specified and directed.
S&F in repairs Hangar obstruction light fitting single LED type without lens colour red suitable to 230 V AC protection weather proof IP55 as per IS2147 sealed against water and dusts complete all as specified and directed. (Make: Bajaj cat Part No BGAV 302 LED or similar in work as mentioned in Particular specification here in after).
S&F in repairs rectangular LED flood light 200W with innovative thermal management and available with multiple optics made in pressure die cast housing and equipped with IP66 protection , giving electric connection and testing complete all as specified and directed.
S & F in repairs LED highbay 200W with fin ventilation technology for better thermal management and with cutting edge LED technology, giving electric connection and testing complete all as specified and directed. (Make as per Bajaj Cat No. BGHB 200W LED G IV or similar in make as mentioned in Particular specification here in after) .
Supply only metal halide single ended 250W clear tubular lamps (MH set) of complete all as specified and directed. (Make : Bajaj cat Part No LHLQABIGUI60250 or similar in make as mentioned in Particular specification here in after).
Supply only in repair heavy duty copper ballast for HPMV 250W high bay fitting complete all as specified and directed. (Make Bajaj cat Part No LHBG08125036 or similar in make as mentioned in Particular specification here in after)
Supply only ignitor suitable for SV & MH lamp 250-400W complete all as specified and directed. (Make Bajaj cat Part No LHGEAJENNNA1999 or similar in make as mentioned in Particular specification here in after)
S&F in repair CMRI certified LED flameproof 1 x 20 W LED tube light fixture complete all as specified and directed. (Make: Bajai cat part No BJEXFTL 136 or similar in make as mentioned in Particular specification here in after)
Supply only capacitor 33 mfd, 250V complete all as specified and directed. (Make Philips,C & S, Havells)
S&F in repairs DB 6 way TPN powder coated sheet enclosure fitted with bus bar, DIN channel, neutral link & earthlink complete all as specified and directed.
S&F in repairs vertical DB 6 way TPN with provision for TP MCCB N3 frame upto 200A in 25KA, 35 KA,as incomer, powder coated sheet enclosure fitted with bus bar, DIN channel, neutral link & earthlink complete all as specified and directed. (Make cart part No CSDBTPNVFDD06 of C & S or similar in make as mentioned in Particular specification here in after)
S&F in repairs MCCB 4 pole,415 volt,fixed type, 160 amps with breaking capacity 36 KA complete all as specified and directed.
S&F in repairs MCCB 4 pole,415 volt,fixed type, 200 Amps with breaking capacity 36 KA complete all as specified and directed.
Taking down unservicible ceiling/exhaust fan and opening the body cover of ceiling fan/exhaust fan, any type, any make and cutting the existing winding without damaging the stator removing the coil insulation and putting new wire of suitable gauge with correct number of turns of auxiliary and main winding, and removing old damged bearings of any capacity and fixing new bearings, varnishing and baking complete and soldering new lead of copper wire three core cables of size 23/0.0076 testing, refixing and commissioning complete including transportation from area of AGE B/R Goa to workshop complete all as specified and directed for the following sizes (Note:- Ball bearing should be measured & paid seperately in given schedule item)
Ceiling Fan 1200mm sweep
Exhaust fan up to 300 mm sweep
Exhaust fan up to 150 mm sweep
Supply only ball bearing suitable size for ceiling fan/pedastal fan/air circulator and any make complete all as specified and directed.
Supply and fix in repairs capacitor of the following capacity including removing old one complete all as specified and directed.
Supply and fix in repairs rubber reel with MS nut Bolt, split/quarter pin for hanging ceiling fan suitable for C/fan complete all as specified and directed.
Supply and fix in repairs anchor fastener bolt suitable for Exhaust fan complete all as specified and directed.
S & F in repairs Mild steel black conduit medium grade including all fittings & Fixcture,boxes (junction/terminal) etc fixed on wall, ceiling/roof/structure etc for hanger lightening complete of the size 20 mm dia complete all as specified and directed.
star freeze service
Indobuildenterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .