Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹7.8 L+₹39,988 (5.41%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹8.5 L+₹1.1 L (15.2%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹8.7 L+₹1.3 L (17.9%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹8.9 L+₹1.5 L (19.9%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹9.7 L
EMD Value
₹19,400
Closing Date
28 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (R)
AGE(I) CIF(R)
PROVN OF ADDN/ALTERATION TO ROOF SHEET TO BLDG NO. T-24 AND T-32 AT MANJAKOT UNDER AGE (I) CIF (R).
2023_MES_587428_1
AGE(I)/R-04/2023-24
Open Tender
Civil Works
Item Rate
120 days
Manjakot
Class E and above and category a (i)
8 documents required · 8 mandatory
₹500
AGE (I) CIF (R)
₹19,400
Yes
13 May 2023
29 Mar 2023
3 May 2023
29 Mar 2023
28 Apr 2023
13 Apr 2023
Amount
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) exc.1.50 Sqm but n exc. 4 Sqm each all as specified.
Pressed steel frames factory made for doors out of 1.25mm thick PBI sheet with one of more rebates including necessary flat iron lugs, hinges, lock strike plate, hinges etc complete, size of frame 125x60mm complete all as specified and directed
S & F 30 mm thick second class hard wood factory made plain, framed, panelled shutters (two numbers of panels) with lock rail and panel of 9 mm BWP commercials ply or 12 mm veneered particle board on both faces. The size of rails and size as per IS:1003 (Part-I), Kiln seasoned & chemically pressure treated, complete all as specified and directed.
S & F 30 mm thick second class hard wood factory made glazed and skelton shutters, open rebated and prepared to receive glass/wire, gauge, etc. (without sash bars), edges of framing plain, chamered or rounded, fitted with cut and mitred beads for securing glass, etc. Size of memebers of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) for doors, complete all as specified and directed.
S & F Floor door stopper of aluminium alloy body and tongue , anodised , with hard drawn steel spring, over all length of cover plate 140 mm , complete all as specified and directed.
S & F 125 mm extruded aluminium alloy handles, fabricated type, anodisedand, complete all as specified and directed.
S & F 150 mm aluminium anodised barrel tower bolt of extruded section and fixed,complete all as specified and directed.
S&F 300 mm mild steel oridinary rat tail rod pattern springs including roller and roller plates, complete all as specified and directed.
S&F mild steel sliding door bolts 300mm long, plate type, stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified.
S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples including fixing with beads, nut bolts, welding, etc complete all as specified.
Hacking out old broken glass (any thickness,size,quality or description) from wooden frames or stone concrete or brick surrounds,glazed with putty or fixed with beads, complete all as specified.
S & F 3.0 mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5sqm in each pane, complete all as specified.
Dismantling of steel (Corrugated, semicorrugated, etc) sheets in roof coverings, M&L pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws. Sheet colour approved by Engineer-in-Charge complete all as specified and directed.
Dismantling of steel (plain) sheets in roof coverings, S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding/ridges to wall, fixed with self tapping screws complete all as specified and directed.
Demolition of Brickwork or stone/ boulders masonry built in cement or cement lime mortar incl all quions, arches, pillars, etc but excluding ashlar facing, dressed stone work and precast concrete articles, M&L Brickwork with old size subclass 'B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 all as specified.
M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified.
Taking down cement plaster on brick or concrete surface and description including raking out joints Hacking for key scrubbing down with water, M&L Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement mixed with and including two coats of cement base paint over a coat of primer on newly plastered surface of wall including preparation of surface and curing after applying each coat complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces any description including raking out joints hacking for keys scrubbing down with water, M&L Rendering 10mm thick in cement mortar 1:6 on fair aces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement including preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of primer, complete all as specified and directed.
M&L for applying one coat of oil bound distemper on walls including preparation of old plastered surfaces complete all as specified.
Material & labour for one coat of cement base paint including preparation of old surface to match the shade as per colour scheme as approved by Engr-in-Charge.
S&F 110mm bore PVC rainwater (SWR) drainage pipe single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends any radius, complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern),CI pipe including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
M&L for mild steel rolled work as in roof trusses ( framed) , trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing( Beam, tee, angle, channel or flat sections ) including distance pieces, cleats etc. , conforming to grade Fe 410-S, complete all as specified and directed.
Prepration of new or previously steel surfaces any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint/camouflaged pattern, complete all as specified and directed.
Prepration of new wood or wooden based new or previously untreated surface of any description, over 10 cm width or gridth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
Demolition of cement concrete ( unreinforced) in ground floors and pavings n exe 15 cm thickness. ( below or above ground level) all as specified.
M&L 75mm thick plain cement concrete type D-2, 1:4:8 (using 40mm graded crushed stone aggregate) as in Sub base/Plinth protection all as spd and directed.
S&F steel window/ventilator with tubular frame factory made double shutter of size 79mmx39mm, 16 guage rectangular tubular frame with side hung shutter glazed and guaged with glazing bars 23x3mm flat iron including projecting type hinges with steel handles and steel peg stay dovetailed or welded including necessary locking arrangement complete, incl one coat of red oxide primer complete all as specified and directed. (Wire guage and glass shall be measured and paid seperately)
S&F in position suspended false ceiling system using E-grid suspended ceiling grid system. The size of grid shall be 600 x 600mm with GI frame work main runner 38 x 24mm cross tee 25 x 24mm and wall angle 24x24mm, using 4 mm thick ceiling panel laminated with PVC film on front face and foil back availabel in due drop texture as per IS-2095, part-I-1996, fixid in the grid of E-grid suspended ceiling grid system duly suspended by 4mm dia GI bar hanger from the purlins of the roof with butter fly clips all as directed and as approved by Engr in Charge and dismantling wall and ceiling board (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including fillets,Complete all as specified and directed by Engineer-in Charge.
M&L for 20 - 25 mm thick cement concrete chequred tiles 30cm x 30 cm, machine pressed, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over 15 mm thick screed bed in CM 1:6 complete all as specified.
S&F in repair stainless steel curtain rods 20 mm dia including brackets with cut hole suitable for 20 mm dia rod fixed with screws and gutties in wall, including end caps with wall ornament and fixed to curtain rod with screws of design/shape all as directed and as approved by Engr in Charge.
S&F Mild steel framed work such as grills, gratings using square/round bar with ends of bars shoulders/welded drilling holes for fixing of guard bars all as specified.
Dismantling of floor tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises, M&L non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for Point wiring complete with 1.5 Sqmm single core multi stranded copper conductor cable PVC insulated unsheathed cable 1100 volt grade enclosed and including PVC casing and capping with fittings and accessories fixed to walls/ceiling by means of PVC rowl plugs fasteners with cadmium plated screws all as per IS including hard wood board PVC board and 3mm thick laminated sheet top covers including 1.5 Sqmm copper PVC insulated unsheathed continuous earth wire and connected to common earth dolly for the following:-
One light/ fan point point controlled by one switch 5 Amp.
Supply and fixing of modular switch single pole one way 6 Amps 1 module complete all as specified and directed
Supply and fixing in replacement PVC/polycarbonate ceiling rose 65X50 mm two to three terminals complete all as specified.
M&L of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 4 Sq mm and one run of 4 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including PVC casing and caping with necessary accessories complete all as directed. Note : 2 Runs of 4 sqmm cable and one run of 4.00 sqmm earth wire with PVC rigid conduit shall be measured as on length.
Supply & Fix Ultra slim modern recess mounting luminaire with high performonging LEDs suitable for mounting with armstrong/grid ceiling of 2`x2` of 36 watt and connecting up with three core copper conductor cable of suitable size, complete all as specified and directed. Make Havells Cat part No.STRATO2X2PLR36WLED830MOD or equivalent cat part of make as specified in list of make here-in-after.
Supply and fix of exhaust fan made of steel body AC single Phase, 230V, 50 Hz,RPM 1400, Copper winding of sweep 300mm with. Blades, frame and louvers complete all as specified.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of ₹ 29,950.00 during AOC Note:- Tenderers shall not quote for this Schedule
Kalsi Engineers and contractors
M/s Anil Engineers & Builders
SUBASH CHANDER SHARMA AND SONS
HUSSAIN ENTERPRISES
NATIONAL TRADING COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .