Shifting and ITC of Floor mounted AC Units i/c providing AC wiring and allied works at CSC Telephone Bhawan, Sri Vijaya Puram.
2024_BSNL_217213_1
50/ED/SVP/2024-25
Open Tender
Electrical Works
Item Rate
30 days
TELEPHONE BHAWAN
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
ACCOUNTS OFFICER CASH
₹8,504
Yes
10 Dec 2024
2 Dec 2024
10 Dec 2024
2 Dec 2024
9 Dec 2024
2 Dec 2024
General servicing & cleaning of 3.0 TR / 1.5 TR Air Conditioner (both indoor and outdoor) by removing all dirt and dust from the fins, and cleaning the fins/tubes with cleaning solution, combing the fins, Cleaning drainage i/c replacing the missing fasteners, lugs, connectors, ferrules, nuts and bolts, checking & tightening the connections, complete as required
Dismantling of 3.0 TR / 1.5 TR type AC unit from the existing position (both indoor and outdoor) with associated support, including pumping down the available refrigerent gas, disconnecting the electrical and mechanical connections, shifting the same to proposed location in the same room etc complete as required
ITC of 3.0 TR / 1.5 TR Split AC unit i/c fixing of out door and indoor unit on the existing wall/angle iron frame, i/c connections with existing wires, leak testing, testing, commissioning etc complete as reqd
S/F of copper refrigerant line combined with 1/2" & 7/8" (nominal) including making thermal insulation with polifoam sheet of not less than 5 mm thick (nominal), supplying and laying 4 core 2.5 sqmm PVC insulated PVC sheathed copper conductor cable, connections etc as required (For 3.0 TR)
Supplying & Charging refrigerent in existing AC unit as per manufacturer recommendations complete as required
Supplying and fixing the following spares in the existing AC units including dismantling the faulty one, fixing, connections with existing wires etc as required. a) Outdoor motor
b) PCB board
c) 4/6 MFD Capacitor
d) Single Phasing Preventer
e) 25A, 3 Pole 3 Phase contactor suitable for operation on 415V, 50 Hz supply
f) Outdoor fan motor with blade
Supplying and Fixing of following size PVC trunking system on the surface of wall / floor / ceiling / on the the existing cable tray with necessary connected accessories like bends, Elbows, Tee, etc as required. [Make MK India / LK or any Similar Superior Make] (a) 25 mm x 12 mm
(b) 32 mm x 12 mm
(c) 50 mm x 16mm
(d) 100 mm x 50mm
Supplying and fixing 3 Way sheet steel MCB enclosure suitable for operation on 230V, 3 Ph AC Supply, on surface/recessed of wall etc as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit/PVC Casing & capping, connections etc as required (a) 2x2.5 Sqmm + 1x2.5 sqmm
b) 4x2.5 sqmm + 2x2.5 sqmm
Supplying and fixing of 4 Way surface/recess mounting, Vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, with provision of MCCB (up to 125A) as incomer, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
b) Triple pole
Supplying and fixing 100A 4 Pole MCCB with 30 kA Breaking capacity, having thremal release range 63-80A, in the existing DB including connections with existing wire/bus link, testing etc as required (M/s L&T DU100H or similar superior make)
Dismantling the unused/unserviceable wiring, conduits, SDB's, light fittings, fans, socket outlets, without disturbing the working of CSC counters, stacking the dismantled items at specified location in the same building etc as required
Supplying and fixing 36 watt LED panel luminaires surface/recessed type, 230V, 50Hz, 1 Ph, including making all electrical connections with suitable size PVC insulated copper conductor wire etc. as required (M/s Cropton Greaves/Havells or SS make)
Supplying and fixing 40 Watt, tower fan with minimum air flow capacity of 2000 cbm/hr, with cord, and speed regulator, complete etc. as required (M/s Philips model: Tower Fan/CX5535/00 or SS make)
stage.html
html • 0.02 MB
finance_240658.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .