Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55,995Accepted-Finance | L1 | Accepted-Finance 1st Lowest Bidder | |
| 2 | L2₹60,350+₹4,355 (7.78%)Rejected-Finance | L2 | Rejected-Finance 2nd Lowest Bidder | |
| 3 | L3₹60,502+₹4,507 (8.05%)Rejected-Finance 00 HAIDARPUR JAMALPUR ROAD SADAR JAUNPUR UTTAR PRADESH 222001 | JAUNPUR | UTTAR PRADESH | 222001 | L3 | Rejected-Finance 3rd Lowest Bidder |
| Sl No | Description | Qty | Unit | M/S PRABHATT ENGINEERING WORKS L2 | R.K. ENTERPRISES L3 | M/s Meera Enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00The following works to be carried out at 220 KV S/S Motiram Adda, Gorakhpur. | ||||||
| 1.01 | Shifting of New 220 &132KV SF6 Circuit Breaker with accessories etc. to New construted open store and proper stacking with the help of hydra and labour to be arranged by the contractor at his own cost. | 1 | Job. | 9,650 ₹9,650 | 9,651 ₹9,651 | 9,310 ₹9,310 Lowest |
| 1.02 | Shifting of Empty Oil drum (130 Nos approx.), Copper Control Cable difrent size (2.6Km approx.), Conductor difrent size (7Km approx.), 245KV Post Insulator (53Set), 220&132KV Isolator Base (9Set) etc. to New construted open store and proper stacking with the help of hydra and labour to be arranged by the contractor at his own cost. | 1 | Job. | 16,650 ₹16,650 | 16,662 ₹16,662 | 16,170 ₹16,170 Lowest |
| 1.03 | Shifting of 245KV CVT (03 Nos.), 132KV CT&PT (05Nos.), 33KV CT&PT (7Nos.), 33KV VCB (01Nos.), Surge Arrestor 198 &120KV (16Nos.) to New construted open store and proper stacking with the help of hydra and labour to be arranged by the contractor at his own cost. | 1 | Job. | 8,100 ₹8,100 | 8,105 ₹8,105 | 7,840 ₹7,840 Lowest |
| 1.04 | Provinding & Fixing of LED tube light different size as per sample for 220KV,132KV and 33KV Control & Relay Panels, 220KV SF6 Circuit Breaker Marshalling Box, 160MVA T/F-I,II,III Marshalling Box, 20MVA T/F Marshalling Box and 132KV SF6 CB Mechanism Box with all cost of men, material T&P etc required for the completion of work. | 34 | Nos. | 300 ₹10,200 | 301 ₹10,234 | 245 ₹8,330 Lowest |
| 1.05 | Provinding & Fixing of Space Heater as per sample for 220KV SF6 Circuit Breaker Marshalling Box, 160MVA T/F-I,II,III Marshalling Box, 20MVA T/F Marshalling Box with all cost of men, material T&P etc. required for the completion of work. | 10 | Nos. | 700 ₹7,000 | 705 ₹7,050 | 637 ₹6,370 Lowest |
| 1.06 | Provinding & Fixing of limit switch with proper rating & size as per sample for 220KV,132KV and 33KV Control & Relay Panels, 220KV SF6 Circuit Breaker Marshalling Box, 160MVA T/F-I,II,III Marshalling Box, 20MVA T/F Marshalling Box and 132KV SF6 CB Mechanism Box with all cost of men, material T&P etc required for the completion of work. | 25 | Nos. | 350 ₹8,750 | 352 ₹8,800 | 319 ₹7,975 Lowest |
Tender Value
Refer Docs
EMD Value
₹1,000
Closing Date
29 Nov 2025, 10:00 amClosed
Executive Engineer
Office of Executive Engineer Electricity 400 KV Sub Station Division Motiram Adda, Gorakhpur
Provinding And Fixing of Panels Light, Space Heater, Limit Switch And Shifting of Materials to New Constructed Open Store at 220 kV Sub Station Motiram Adda, Gorakhpur Under E400kV S/S Division Gorakhpur.
2025_UPTCL_1088701_1
E-TENDER No. 24/E400KV/SSD/GKP/2025-26
Open Tender
Electrical Works
Item Rate
60 days
EE E400 KV S/S Motiram Adda Gorakhpur
Please Refer Tender Documents
2 documents required · 2 mandatory
₹590
EE E400KV S/S Division Gorakhpur
₹1,000
29 Nov 2025
7 Nov 2025
29 Nov 2025
7 Nov 2025
29 Nov 2025
7 Nov 2025
Amount
The following works to be carried out at 220 KV S/S Motiram Adda, Gorakhpur.
Shifting of New 220 &132KV SF6 Circuit Breaker with accessories etc. to New construted open store and proper stacking with the help of hydra and labour to be arranged by the contractor at his own cost.
Shifting of Empty Oil drum (130 Nos approx.), Copper Control Cable difrent size (2.6Km approx.), Conductor difrent size (7Km approx.), 245KV Post Insulator (53Set), 220&132KV Isolator Base (9Set) etc. to New construted open store and proper stacking with the help of hydra and labour to be arranged by the contractor at his own cost.
Shifting of 245KV CVT (03 Nos.), 132KV CT&PT (05Nos.), 33KV CT&PT (7Nos.), 33KV VCB (01Nos.), Surge Arrestor 198 &120KV (16Nos.) to New construted open store and proper stacking with the help of hydra and labour to be arranged by the contractor at his own cost.
Provinding & Fixing of LED tube light different size as per sample for 220KV,132KV and 33KV Control & Relay Panels, 220KV SF6 Circuit Breaker Marshalling Box, 160MVA T/F-I,II,III Marshalling Box, 20MVA T/F Marshalling Box and 132KV SF6 CB Mechanism Box with all cost of men, material T&P etc required for the completion of work.
Provinding & Fixing of Space Heater as per sample for 220KV SF6 Circuit Breaker Marshalling Box, 160MVA T/F-I,II,III Marshalling Box, 20MVA T/F Marshalling Box with all cost of men, material T&P etc. required for the completion of work.
Provinding & Fixing of limit switch with proper rating & size as per sample for 220KV,132KV and 33KV Control & Relay Panels, 220KV SF6 Circuit Breaker Marshalling Box, 160MVA T/F-I,II,III Marshalling Box, 20MVA T/F Marshalling Box and 132KV SF6 CB Mechanism Box with all cost of men, material T&P etc required for the completion of work.
M/S PRABHATT ENGINEERING WORKS (BID ID -5702325)
R.K. ENTERPRISES (BID ID -5708812)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.28 MB
TECHNICAL_24.pdf
Tender Documents • 1.10 MB
BOQ_1997922.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .