| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹31.0 L+₹2.1 L (7.12%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹31.7 L+₹2.8 L (9.70%)Rejected-Finance 5 L LEHAL COLONY PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹32.1 L+₹3.2 L (11.2%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹32.4 L+₹3.5 L (12.1%)Rejected-Finance KATTI GHATI SHIV COLONY ALWAR ALWAR RAJASTHAN 301001 | ALWAR | RAJASTHAN | 301001 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
17 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (A) Jaisalmer
HQ CWE (A) JAISALMER-345001
REPAIR AND MAINT OF PERIMETER SECURITY LIGHTS UNDER GE (A) AT MIL JAISALMER
2024_MES_639488_1
84174/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
JAISALMER
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (A) Jaisalmer
₹94,000
Yes
29 Feb 2024
29 Jan 2024
19 Feb 2024
29 Jan 2024
17 Feb 2024
12 Feb 2024
29 Jan 2024 - 5 Feb 2024
Amount
Taking down defective street light/ flood light/post top lantern fitting of any size /type/capacity any Watt from height of pole/walls/high mast of any location up to 16M height for repair work and fixing back after repair work including checking, inspecting, testing and commissioning complete all as specified and directed by Engineer-in-charge. Note :- (a) Spares like LED Driver,surge protector etc. shall be measured and paid as supply only separetely under relavant items of schedule'A' (b) Necessary tools like mobile ladder & other T&P required etc shall be arranged by the contractor without any extra cost. (c) The rate quoted deemed to be inclusive for minor repair parts like nuts, bolts, cirle clips , clamps etc required if any at site.
Supply only electronic driver for LED light fitting, LED out put power 30 watt, input voltage range : 170 - 300 volt AC , out put voltage DC as per make/ model range : 24 volt to 110 volt, make as per site requirement complete all as specified and directed by Engineer-in-charge.
All as per Item No 2.00 here-in-before but capacity 45 watt
All as per Item No 2.00 here-in-before but capacity 60 watt
All as per Item No 2.00 here-in-before but capacity 70 watt
All as per Item No 2.00 here-in-before but capacity 90 watt
Supply only Surge Protector 10KV for street light fitting, Normal voltage input range : 170- 300 volt complete all as specified.
Labour only for making unserviceable street/security lights/solar light serviceable placed at pole by disconnection / Isolating power supply either from pole junction box or by disconnecting overhead jumpers and carrying out de-carbonization / de-sulphation at connection points with overhead conductor / light fitting / junction box terminal including replacement connection wire complete all as specified and directed by Engineer-in-charge. Note : - Cable shall be measured and paid separately under relevant items "supply only"
Supply And Fixing Led Street Light Of Capacity 45 Watt, Including making electrical connection to the fitting with suitable size of wire,Having Pressure Die Cast Aluminium Housing, Ip-66 Having Efficiency Of ≥ 100 Lumens/Watt, Operating Voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D < 10 % , Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver Also. The Fitting Must Be Suitable For 35 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements ) Including Connecting Up With Three Core Twisted Flexible Copper Conductor Cable With Suitable Size, Mounting Pipe/Bracket , Nut, Bolts And Accessories Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. complete all as specified and directed by Engineer-in-charge.
Supply And Fixing Led Street Light Of Capacity 60 Watt, Including making electrical connection to the fitting with suitable size of wire,Having Pressure Die Cast Aluminium Housing, Ip-66 Having Efficiency Of ≥ 100 Lumens/Watt, Operating Voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D < 10 % , Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver Also. The Fitting Must Be Suitable For 35 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements ) Including Connecting Up With Three Core Twisted Flexible Copper Conductor Cable With Suitable Size, Mounting Pipe/Bracket , Nut, Bolts And Accessories Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. complete all as specified and directed by Engineer-in-charge.
S&F Led Flood Light Fitting 250 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy >= 120lm/W And Total Lumens Output Must Be = 30,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F > 0.95, , Cct – 5700k, Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X Frlsh Wire, Including Disconnected & Taking Down Old Unserviceable Light complete all as specified and directed by Engineer-in-charge. Make : Crompton Cat part No CFS-250-57-30 D-HL2-GL-NSG or equivalent make and model as approved by GE.
S&F Led Flood Light Fitting 400 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy >= 120lm/W And Total Lumens Output Must Be = 30,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F > 0.95, , Cct – 5700k, Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X Frlsh Wire, Including Disconnected & Taking Down Old Unserviceable Light complete all as specified and directed by Engr-in-Charge Make : Crompton Cat part No CFS-506-400-57-60D-GL-NSG or equivalent make and model as approved by GE.
S&F Led Flood Light Fitting 200 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy >= 120lm/W And Total Lumens Output Must Be = 30,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F > 0.95, , Cct – 5700k, Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X Frlsh Wire, Including Disconnected & Taking Down Old Unserviceable Light complete all as specified and directed by Engineer-in-charge. Make : Crompton Cat part No CFS-501-200-57-60D-SL-GL-NSG or equivalent make and model as approved by GE.
Supply only in replacement of PVC insulated, sheathed weather proof, copper conductor of size 1.5 sqmm, 3 core complete all as specified and directed by Engineer-in-charge.
Supply only in replacement of PVC insulated, sheathed weather proof, aluminium conductor of size 6 sqmm, 2 core complete all as specified and directed by Engineer-in-charge.
M&L in replacement of PVC conduit 20 mm, heavy duty rigid non metallic including of all tee, bends, elbows etc complete all as specified and directed by Engineer-in-charge.
Supply, transportation fixing and errection of prestressed cement concrete pole in repair 9 metre long, minimum cross section 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class -10 confirming to IS-1678 and including making alternate white and black strips 30 cm height up to 1.5 mtr from ground level with two coats of synthetic enamel paint over a coat of primer and Dismantling of old UNSV /broken PCC LT pole including bracket,security light,junction box,service cable and coping of pole and reuse the same accessories if in good condation complete all as specified and directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate in foundation for PCC poles/struts including necessary form work complete all as specified and directed by Engineer-in-charge.
M & L for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation of PCC pole /stay assembly including necessary form work up to groud level complete all as specified and directed by Engineer-in-charge.
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) for pedestal/coping/plinth of poles, including necessary form work finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
Taking out UG LT cable of any size/any core complete all as specified and directed by Engineer-in-charge.
Supply, laying, test and commissioning in repair of LT UG ,XLPE insulated, heavy duty, 1100V grade of electric cable size 50 Sqmm 3.5 core with aluminium conductor ,served with an inner sheathing of PVC tape armoured eith galvanized steel wire or tape and overall PVC sheathed, laid in trench or passing through pipe, making all connection with and including provision of necessary glands ,lugs,bushing etc as required complete all as specified and directed by Engineer-in-charge. Note : Earthwork excavation sand cushioning ,Jodhpur stone patti, GI protcetion pipe shall be measured and paid separately in their respective items.
All as per Item No 22.00 here-in-before but size 10 Sqmm 2core
All as per Item No 22.00 here-in-before but size 10 Sqmm 4core
All as per Item No 22.00 here-in-before but size 16 Sqmm 4core
All as per Item No 22.00 here-in-before but size 25 Sqmm 4core
All as per Item No 22.00 here-in-before but size 35 Sqmm 3.5 core
Relaying /Refixing only existing XLPE insulated , Armoured , Electric Power UG Cable (Heavy Duty), 1100 Volt Grade , Nominal Cross sectional area 50 Sqmm 3.5 Core complete all as specified and directed by Engineer-in-charge.
All as per Item No 28.00 here-in-before but size 10 Sqmm 2core
All as per Item No 28.00 here-in-before but size 10 Sqmm 4core
All as per Item No 28.00 here-in-before but size 16 Sqmm 4core
All as per Item No 28.00 here-in-before but size 25 Sqmm 4core
All as per Item No 28.00 here-in-before but size 35 Sqmm 3.5 core
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc not exceeding 10 sqm on plan and getting out in Soft/Disintegrated rock complete all as specified and directed by Engineer-in-charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in Soft/Disintegrated rock complete all as specified and directed by Engineer-in-charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for laying 40 to 50 mm thick roughly hammer dressed jodhpur stone patti cable cover 25 cm to 30 cm wide and not exc 60 cm long each laid dry abuting with each other with maximum gap between adjacent patti/ slabs not exc 10 mm complete all as specified and directed by Engineer-in-charge.
Relaying only of existing Stone Patti cable cover in Trenches for Under Ground Cable Protection (Serviceable Materials obtained from Item No. 21.00 here-in-before) complete all as specified and directed by Engineer-in-charge.
M/L for sand for cushioning with layers of sand 8 cm before laying of cable & 15 cm after laying of cable (total 23 cm ) in trenches, duly punning to a thickness of 18 cm for cable protection complete all as specified and directed by Engineer-in-charge. Note :- Thickness after punning shall be measured for payment.
Supply & fix in repair 40 mm bore GI tubing light grade in trenches or on pole for cable protection complete all as specified and directed by Engineer-in-charge.
Supply & fix in repair 50 mm bore GI tubing medium grade in trenches or on pole for cable protection complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repair of pole mounted junction box of outer size 300x200x120mm made out of FRP body (hot mulded type) with IP-66 protection and locking with screws alongwith 6 Amp rating MCB SP-01 No, up to 50 Amp rated 4 pole connector suitable to insert the cable size up to 25 sqmm x 4 core -02 No and din rail suitable for mounting the MCB/Connector etc complete in side box and duly fixed with 25x3mm FI clamps with nut bolts of suitable size on steel tubular pole/PCC/RCC pole including cable glands, aluminum lugs/thimbles for incoming and out going cables and complete all as specified and directed by Engineer-in-charge.
S&F in repair, galvanised iron bracket of 'medium grade' pipe 40 mm bore, length 1.20m, bend to required shape with 2 Set clamps made of 40x6mm FI and suitable size of bolts, nuts & washers, etc duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
Supply & fix MCB, single pole, 16-32 Amp, 240 Volts, 'C' Curve 10KA including dismantling old unserviceable MCB complete all as specified and directed by Engineer-in-charge.
Supply & fix MCB, SPN, 32 Amp, 240 Volts, 'C' Curve 10KA including dismantling old unserviceable MCB complete all as specified and directed by Engineer-in-charge.
Material and labour for straight through (Heat Shrinkable) cable jointing kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 10/50 SQmm including dismantling the old burnt cable joint termination complete all as specified and directed by Engineer-in-charge.
Material and labour for preparation of old painted surface of LT Concrete electric pole of any size by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior , synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height 1.5 mtr above the ground level, including painting the cross arms/bracing support on poles with a coat of aluminium paint, silver colour aluminium paint with coating of primer and writing of identification Nos with proper stencil cut etc as per directions by Engr-in-Charge.
Supply and fix Din type HRC fuse link of Required rating 32A/63A/100A Suitable for HG type 20H/2 complete all as specified and directed by Engineer-in-charge. Make :-Seimens/L&T/Havells.
S&F in repairs Nature switch (using infrared sensor technology) based automatic street light control panel. The panel should be enough to take three phase load of 25 kw.Nature switch operation should be based on natural light luxes. required illuminance level switching ON is <=60 and for Switching OFF >=10 lux. the senser should be have a part night operation facility of min 4HRS to max 12 hrs . The senser along with suitable 3 phase load of 25 KW with 3 nos contractor ,3 nos Incoming MCBs of 63 Amps and outgoing MCBs of 63 Amp and circuit wire copper of min 16 Sqmm and should be enclosed in a pole /wall mountig Rust proof ,Electric shock proof ,Termite proof and FR grade thermoplastic polycarbonate enclouser (with hinged lid) conforming to IP66 protection.The circuit should also have provision gor Manual or Auto operation complete all as specified and directed by Engineer-in-charge. Make :- Kakatiya Energy system, sw , Indoasian, L&T
Supply & fix DX3 Power contactor suitable for power supply 40 Amps 4 pole 4 NO Contactor including making electrical connection to the contactor complete all as specified and directed by Engineer-in-charge.
Supply & fix DX3 Power contactor suitable for power supply 63 Amps 4 NO Contactor including making electrical connection to the contactor complete all as specified and directed by Engineer-in-charge.
M&L for Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate complete and matching with the surroundings complete all as specified and directed by Engineer-in-charge.
Note :- (i) Contractor has to arrange his own vehicles along with mounted hydraulic ladder/articulated & telescopic boom lift arrangement for attending the complaint throughout jaisalmer cantt area. (ii) Contractor shall depute minimum 2 staff daily to attend and rectify the complaint. if not, Contractor shall have to bear a penalty of Rs 50.00 per complaint or maximum of Rs 500 per day on this account (iii) Complaints has to attend and rectify the complaint/defect irrespective of no of trips/Complaints as alloted by Eng-in-Charge. (iv) Complaint should be attend in Night also (v) Contractor has to arrange telescopic boom lift for maintenance at height of 15m at his own cost. No extra payment will be paid by department.
Manisha Enterprises
M/s Shree Construction Company
M/s Rohit Construction Co.
M/s Yash Electrical and Maintenance
M/S SUMAN ENTERPRISES
SHOBHIT BUILDERS
GITANSH ENGINEERS AND COMPANY
new india engineers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .