SE VGTPS
VGTPS, Ramanathapuram - 623536
Periodical, running and breakdown maintenance of 50TR Centralized HVAC system, 15TR package unit, Split AC Units, Window AC and Ventilation system for the period of Six months from 01.04.2021 to 30.09.2021
2021_EB_194802_1
SE/VGTPS/RMD/WC.NO.166/20-21
Open Tender
Miscellaneous Works
Works
180 days
VGTPS
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹4,100
Yes
24 Feb 2021
9 Feb 2021
24 Feb 2021
9 Feb 2021
23 Feb 2021
9 Feb 2021
180 days
Amount
Periodical Maintenance
Charges for routine inspection for any abnormal noise, leak in 50TR centralized AC units of MCR or in the 15TR AC package unit including attending minor defects as per the direction of Engineer in-charge
Charges for checking and cleaning AC plant inlet and outlet ducts including checking damper operation, lubrication in the AHU of MCR as per the direction of Engineer in-charge
Inspection of AHU in 50 TR centralized AC system for removing 2sets of evaporator Air intake filters for cleaning with air and water, re fixing evaporator air intake places etc., as per the direction of Engineerin-Charge
Charges for cleaning evaporator coil fins in the AHU of MCR with water and air as per the direction of Engineer in-charge.
Charges for cleaning of external condenser coil fins with water & air in the 50TR centralized AC units of MCR and normalizing as per the direction of Engineer in-charge
Inspection of AHU blowers for replacement of worn out parts if any, assembling of the blowers, alignment of the blower with motor etc., as per the direction of Engineerin-Charge
Inspection of 50 TR centralized AC system, if any defects/leakages noticed in drain line to be attended and cleaned as per the direction of Engineer-in-Charge.
Inspection of AHU in 50 TR centralized AC system for adjustment of belt tension / replacement of belts if necessary (belts will be supplied by the TANGEDCO) as per the direction of Engineerin-Charge.
Inspection of AHU of 50 TR centralized AC unit, for assessment of internals of gas expansion valve, rectification of fault/replacement by new gas expansion valve supplied by the TANGEDCO as per the direction of Engineer-in-Charge.
Charges for visual inspection of condenser fan of condensing unit of 50TR Centralized AC units for proper functioning of the unit or decoupling & coupling of condenser fan motor in case of failure to facilitate rewinding works by Electrical maintenance division and normalizing as per the direction of Engineer in-charge
Charges for checking and cleaning AC plant inlet and outlet ducts including checking damper operation, lubrication in the 15TR Switch yard AC package unit as per the direction of Engineer in-charge
Charges for removing/replacing 3sets (3Nos/set)of filters in 15 TR AC package unit in switchyard, inspection and cleaning with air and water, re fixing the filters as per the direction of Engineer in-charge.
Charges for cleaning evaporator coil fins in the 15TR AC Package unit with water and air as per the direction of Engineer in-charge
Charges for cleaning of external condenser coil fins with water & air in the 15TR AC Package unit and normalizing as per the direction of Engineer in-charge
Charges for visual inspection of blower & blower bearings for any abnormality, replacement of blower bearings (supplied by the TANGEDCO), if necessary in the 15 TR Switchyard AC package unit and normalizing as per the direction of Engineer in-charge
Charges for visual inspection for any defects/leakages and attending defects/leakages at drain lines of 15TR Switchyard Package AC unit and normalizing as per the direction of Engineer in-charge.
Charges for visual inspection for tightness/belt tension, adjustment of belt tension replacement of belts if necessary (belts will be supplied by the TANGEDCO) in the 15 TR Switchyard AC package unit and normalizing as per the direction of Engineer in-charge
Charges for visual inspection and assessment of internals of gas expansion valve, rectification of fault/replacement by new gas expansion valve (supplied by the TANGEDCO), if necessary in the 15 TR Switch yard AC package unit and normalizing as per the direction of Engineer in-charge.
Charges for visual inspection of condenser fan of condensing unit of 15 TR AC system for proper functioning of the unit or decoupling & coupling of condenser fan motor in case of failure to facilitate rewinding works by Electrical maintenance division and normalizing as per the direction of Engineer in-charge
Inspection of split AC / Tower AC units, for leak testing using N2 gas and refilling of R22 gas (N2 & R22 gasses will be supplied by the TANGEDCO) as per the direction of Engineerin-Charge.
Inspection of split AC / Tower Ac units, for removal of air filters, inspection and cleaning of air filter elements as per the direction of Engineerin-Charge.
Inspection of split AC / Tower AC units, for opening of external covers of condenser and evaporator, inspection of condenser coils and thorough cleaning etc., as per the direction of Engineerin-Charge.
Charges for disassembly, inspection, cleaning of air filter, condenser unit and attending defects in blower fan (if any), compressor in the window 1.5TR AC units and normalizing as per the direction of Engineer in-charge.
Charges for replacement of failed compressor, refilling of R22 Gas, leak testing and normalizing in the window AC unit including joining of inlet and outlet copper pipes by bracing method for 6 Nos of joints of size upto 16mm dia as per the direction of Engineer in-charge.
Inspection and cleaning of air filters / fresh air supply grills in ventilation units of cable spreader room, etc., as per the direction of Engineerin-Charge
Inspection of ventilation blower of cable spreader room for attending minor defects and adjustment of belt tension/replacement of belts in the Blower, replacement of worn out parts, assembling of the blowers alignment of the blower with motor, greasing and normalizing, etc.,as per the direction of Engineerin-Charge.
Breakdown Maintenance
Charges for complete overhauling of 50TR capacity Reciprocating AC compressor. Disassembly the Compressors into its components, thorough cleaning of parts, replace the worn out parts, drain the old oil and top up the new oil, reassemble the compressor and carryout N2 pressure test to the required pressure and vacuum testing and R22 gas charging, testing and normalizing as per the direction Engineer In charge. (The required spares, lube oil, N2 and R22 gas will be supplied by TANGEDCO).
Charges for breakdown work in 50TR capacity AC Compressor unit including decoupling the motor by releasing the coupling, dismantling the external covers of compressor unit, inspection of compressor internals for any damages, replacement of suction/discharge reeds, if necessary, attending minor rectification works and refilling of R22 gas, motor to compressor alignment checking as per the direction of engineer in charge. (The required spares, lube oil, N2 and R22 gas will be supplied by Board).
Charges for breakdown work in 50TR capacity AC Compressor condensing unit (ACU-50-A model, Voltas make 5H66 & 5H60) including dismantling of the condenser fan, visual inspection for any external damages, through cleaning of fins of tubes with air and water and checking the complete unit with 1.25 times of the operating pressure with N2, attending any leak by brazing, reassembling coils, structure, fan and commissioning all complete as per the direction of Engineer in-charge
Charges for breakdown work in Air Handling unit of MCR including dismantling of external covers of AHU, removal of Air Filters, inspection/replacement of Gas Expansion Valve, visual inspection for any damages in evaporator coil, leak testing with N2 Gas, attending leak if any by brazing, thorough cleaning of evaporator coil with air & water, Refilling of R22 gas, testing and normalizing as per the direction of Engineer in-charge. (N2 and R22 gas will be supplied by TANGEDCO).
Charges for breakdown work in 15TR capacity semi hermetic AC compressor by disassembly of the compressor external covers, inspection of Gas Expansion Valve, dryer & evaporator coil, thorough cleaning of evaporator coil fins with air & water, draining of old compressor oil and topup with new oil, N2 pressure test to the required pressure and vacuum testing,attending leak if any by brazing and R22 gas changing all complete and normalizing as per the direction of Engineer in charge. (The required spares, lube oil, N2 and R22 gas will be supplied by TANGEDCO).
Charges for breakdown work in 15TR capacity semi hermetic AC compressor condensing unit including dismantling of external covers of condensing unit, condenser fan, visual inspection for any damages/ leaks, thorough cleaning of fins with air & water, N2 pressure test to the required pressure and vacuum testing, attending leak if any by brazing and R22 gas changing all complete and normalizing as per the direction of Engineer in charge. (The required spares, lube oil, N2 and R22 gas will be supplied by TANGEDCO)
Charges for Disassembly of Tyre Coupling of 50 TR AC Compressor in centralized system Inspection of all parts, cleaning, rectification / renewal of parts, re-assembly (Coupling Tyre, spares will be supplied by the TANGEDCO) normalizing as per the direction of Engineer - in - charge.
Charges for overhauling the Ventilation Damper, checking the damper open/ close position and its blades / replacing the wornout parts / blades, inspecting the Ducts / replacing the corroded portion of the ducts for the Cable gallery Room,etc., as per the direction Engineerin-charge. The required spares will be supplied by the TANAGEDCO.
Charges for breakdown work in Ventilation system by removing the belt, pulley & bearings for any damages, replacement of pulley/bearings, if necessary, cleaning the blower (or) decoupling & coupling of motor, alignment checking, assembling & normalizing as per the direction of Engineer in - charge
stage.html
html • 0.01 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .