Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
15 Apr 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Officer
Shrirampur Municipal Council, Shrirampur
As per NIT Er.No.4
2021_DMA_648286_3
SMC_ELE_Signal_2021-22_1
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Shrirampur
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
₹5,000
17 Apr 2021
2 Apr 2021
16 Apr 2021
2 Apr 2021
15 Apr 2021
2 Apr 2021
90 days
Amount
Servicing and maintenance charges for automatic traffic signal of microprocessor based or solid state controller for a Month, for 3 Chowk. (C.Shivaji Chowk, M.Gandhi Chowk, Siddhivinayak Chowk)
Providing and fixing of Master PCB required for repair and replacement spares of microprocessor based of solid state controller as per requirement with all required materials, taxes in force transportation charges at the work site
Providing and fixing of MCB 10A. singal pole required for repair and replacement spares of microprocessor based of solid state controller as per requirement with all required materials, taxes in force transportation charges at the work site
Providing and fixing of Display PCB required for repair and replacement spares of microprocessor based of solid state controller as per requirement with all required materials, taxes in force transportation charges at the work site
Providing and fixing of PVC terminal block 10A, 2*12 required for repair and replacement spares of microprocessor based of solid state controller as per requirement with all required materials, taxes in force transportation charges at the work site
Providing and fixing of Out Put PCB required for repair and replacement spares of microprocessor based of solid state controller as per requirement with all required materials, taxes in force transportation charges at the work site
Supplying and laying of multi core armoured solid copper conductor PVC insulated & Sheathed cable of 4 Core 1 sq.mm c/s area as per J.S.1554 standard.
Supplying and laying of multi core armoured solid copper conductor PVC insulated & Sheathed cable of 14 Core 1 sq.mm c/s area as per J.S.1554 standard.
Supplying and laying of multi core Unarmoured solid copper conductor PVC insulated & Sheathed cable of 3 Core 1 sq.mm c/s area as per J.S.1554 standard.
Supplying and laying of multi core Unarmoured solid copper conductor PVC insulated & Sheathed cable of 7 Core 1 sq.mm c/s area as per J.S.1554 standard.
Supplying and laying of multi core Unarmoured solid copper conductor PVC insulated & Sheathed cable of 14 Core 1 sq.mm c/s area as per J.S.1554 standard.
Excavation of concrete/Damber road for laying cable.
Rewiring of controller
Removal of 8’’ dia& 12’’dia single aspect lamp lead
Removal of 8’’dia &12’’dia double aspect
Removal of 8’’dia &12’’dia triple aspect
Removal of RTS controller box
Cable joint kit
Supplying and fixing M.S Controller box
Supplying of traffic signal pole assembly complete with 100mm inner dia,pipe(B class) including providing M.S base plate of size 200mm*200mm*10mm thick welded with bottom of pole flanged FRP cap at top, the pole painted with 2 coast of zinc chromate primer and in addition bituminous painting for the bottom 1.5m portion of pipe,providing cable entry bole etc. Complete. For 6.00 mtrs. Long pole
Supplying of traffic signal pole assembly complete with 100mm inner dia,pipe(B class) including providing M.S base plate of size 200mm*200mm*10mm thick welded with bottom of pole flanged FRP cap at top, the pole painted with 2 coast of zinc chromate primer and in addition bituminous painting for the bottom 1.5m portion of pipe,providing cable entry bole etc. Complete. For Cantilever pole 11mtrs.long.
Supply of 300mm dia FRP/polycarbonate signal head assembly including installation accessories like flexible pipes, conduits ,zincpassivated brackets. Framework PVC insulted connection wire complete. For Single aspect
Installing the controller on c.c 1:2:4 Pedestal, 60 cm above G.L. of suitable size testing and commissioning ith any number of phases including earth station as per I.S. rules etc.
Erection of traffic signal pole in 60 cm*60 cm*1.0m deep pit with 1:1:5:3 cement concrete and providing coping of30cm dia in c.c. plastering finishing curing. For Normal pole
Erection of traffic signal pole in 60 cm*60 cm*1.0m deep pit with 1:1:5:3 cement concrete and providing coping of30cm dia in c.c. plastering finishing curing. For Cantilever pole
Local earthing of signal/street light pole when used as traffic signal pole with 10m length of 10 SWG G.I. wire loop being kept at minimum of 2m below G.I. etc complete as per I.S rules
Painting of signal pole with 2 coats .of synthetic enamel paint of approved colour For Normal pole
Painting of signal pole with 2 coats .of synthetic enamel paint of approved colour For Normal pole For Cantilever pole
Mounting of 200mm/300mmF.R.P./polycarbonate traffic signal heads on the pole and wiring the same to the tag block in pole cap/junction box with ferruled pin type plug termination etc. Complete. For Normal Pole and Single aspect
Mounting of 200mm/300mmF.R.P./polycarbonate traffic signal heads on the pole and wiring the same to the tag block in pole cap/junction box with ferruled pin type plug termination etc. Complete. For Normal Pole and double aspect
Mounting of 200mm/300mmF.R.P./polycarbonate traffic signal heads on the pole and wiring the same to the tag block in pole cap/junction box with ferruled pin type plug termination etc. Complete. For Normal Pole and Triple aspect
Supply &fixing of Red LED retrofit
Supply &fixing of Amber LED retrofit
Supply &fixing of Green LED retrofit
Supply &fixing of PED Green LED retrofit
Supply &fixing of PED Red LED retrofit
Supply& fixing of Down Counter PCB.
Supply&Fixing of Down Counter Box.
Supply & Fixing of 50mmDWC of HDPE Pipe
Supply& fixing of SMPS 24V/10A.
Supply & Fixing of power supply 1A
Supply & installation of 2 & 1/2 dight Countdown Timer suitable for traffic singnals including Ac/ Dc controller and compatible with traffic singnal controller .with traffic singal controller .it should be mounted on traffic singal pole with necessary clamps
Repairing of Rectrofiting (any type)
Repairing of 5 volt and 24 volt SMPS Power supply board
Repairing of LDS card / RTC Driver card/ Node controller for microprocessor controller
Repairing of CPU card / Mother board card for microprocessor controller
Removal of singal pole assembly
Supply and installation of 300 mm diapolycarbonate traffic signal rhetrofit prismatic lenses with appropriate colour
Supply installation commissioning of advanced micro – processor / microcontroller based automatric traffic singal controller system housed in 16 SWG fabrication water proof vandal proof and splash proof powder coated pacivated and painted with two coats of enamel paint the controller should be installed on cement concrete pedestral 60 cm above ground leval of suitable size with necessary earthing provision
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .