Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC MADHYAMOHANBATI RAIGANJ NORTH DINAJPUR WEST BENGAL 733134 | RAIGANJ | NORTH DINAJPUR | WEST BENGAL | 733134 | L1 | Accepted-AOC AOC Accepted | |
| 2 | L2₹4.7 L+₹2,627 (0.57%)Rejected-Finance SARAT PALLY 95 97 BANK COLONY ENGLISH BAZAR MALDA WEST BENGAL 732101 | ENGLISH BAZAR | MALDA | WEST BENGAL | 732101 | L2 | Rejected-Finance Financially Rejected | |
| 3 | L3₹4.7 L+₹4,447 (0.96%)Rejected-Finance FOREST MORE SUBHASGANJ RAIGANJ UTTAR DINAJPUR | RAIGANJ | UTTAR DINAJPUR | WEST BENGAL | L3 | Rejected-Finance Financially Rejected |
Tender Value
₹4.7 L
EMD Value
₹9,370
Closing Date
26 Sept 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer
Assistant Engineer, PWD, Raiganj Electrical Sub-Division Karnajora Raiganj
Urgent Illumination works with allied EI works at the campus of Kaliyaganj State Gen Hospital in the district of Uttar Dinajpur,P.W.D
2024_WBPWD_750828_1
WBPWD/AE/RESD/eNIQ-07/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Kaliyaganj
Please refer Tender documents.
4 documents required · 4 mandatory
₹9,370
Yes
21 Oct 2024
13 Sept 2024
30 Sept 2024
20 Sept 2024
26 Sept 2024
20 Sept 2024
Amount
Supply & Delivery of out door type security light LED fittings (120watt) with necy. arrangement as required.[Make: Philips BRP340 LED 138 CW HO SLC S1 PSU GR/ Havells/equivalent spec of K-Lite/Crompton]
Supply & Delivery of out door type security light LED fittings (45watt) with necy. arrangement as required.[Make: Philips BRP 052 LED 045 CW SLMR FG S1 PSU GR / Havells/equivalent spec of K-Lite/Crompton]
Supply & Delivery of road lighting luminaire 250V, 65 W (Maximum) ( IP 66 ) with peanut lens and high power LED and to ensure uniform distribution, higher spacing between poles and maintenance free system and system lumen output will be minimum 7200 lumen suitable for use with 230Volt 50Hz AC supply etc as required. as directed by EIC.[Make: Philips BRP062 LED 65 W CW SLA S1 PSU / Havells/equivalent spec of K-Lite/Crompton]
S & F 1.5 mts. long header cum bracket suitable for ( 410 S P – 60 pole ) having suitable length and gauge of stiffner and other end having 50 mm. x 50 mm. x 10 mm. angle and 50 mm. x 10 mm .flat iron bar duly welded on header arrangement for fixing flood light and C G box incl. S&F double nuts bolts washers etc. as per direction of the E I C .
Wiring by 3x 1.5 sqmm single core PVC insulated copper wire through polythene pipe from loop box to fitting as per GS. [Make- Finolex/Havells/Gloster]
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
Painting of each Steel Tubular Pole of lengths ( Upto 9 Mtr ) with 2 coats of Aluminium Paint over 1 coat of RO primer as per GS
Providing CC (6:3:1) muffing 600x600x760 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if necessary (Without Loop Box)
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting 250 x 250 x 100mm
Supplying & fixing 32 mm dia medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required.
Supply & Delivery of 1.1 kv grade 2Cx6 sqmm XLPE-armoured AL. cable, as directed by EIC. [Make - Gloster/Havells/RR Kabel]
Supply & Delivery of 1.1 kv grade 4Cx25 sqmm XLPE-armoured AL. cable, as directed by EIC. [Make - Gloster/Havells/RR Kabel]
Fixing of Cable along the lenth of O.H. pole incl. S & F MS pole clamps fabricated from 25 mm x 6 mm MS flat incl. painting
Laying of above 2Cx6 sq.mm. XLPE/Ar. AL Cable on wall/surface incl. S&F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting, as per GS.
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Laying of above cable, in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed, as per GS.
S&F compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of 2Cx6 sqmm XLPE/PVC armoured cable, as per GS.
Do and Do….4 core 25 Sqmm
Finishing the end of 2Cx6 sqmm XLPE/PVC armoured cable by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials, as per GS.
Do and Do….4 core 25 Sqmm
S&F of 250V double door Timer DB [equivalent of 2+8 way SPNDB] with sheet steel enclosure, pnosphitised powder coated neutral bar, DIN rail with IP-43 potection comprising with 1 no. 25A DPMCB ('C' curve 10KA), 2 no. 16A SPMCB ('C' curve 10KA), 1no. Programmable time switch-24 hrs with minimum switching of 15 minutes and 1 no. 18A/25A 2-Pole power contractor with inner-outer plate & internal wiring by suitable size of cu. wire incl. 1 no. Auto-Manual bypass toggle switch and provision for earthing attachment, incl. LED indication light for running condition with mechanical locking arrangement, as directed by EIC.[Make-ABB/L&T/Crabtree]
Supply and delivery of 230V 230mm (9") Exhaust fan with all necessary accessories, as directed by EIC. [Make: EPC Heavy Duty, Usha, CG, Bajaj or equiv Make]
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) for the above Exhaust Fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire & making connection for exhaust fan, as per GS.
Earthing with 50 mm dia ISI-Medium GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level. By ISI-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc as required.
Connecting the equipments to earth busbar including S&F 4 SWG Solid GI(Hot Dip) wire on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
Rate Sholud be including of all type of taxes .
M/S. M. R. ENTERPRISE (BID ID -5621218)
PRITAM MAHATO (BID ID -5617712)
technical_1659470.pdf
PDF • 0.41 MB
techsummary_1659470.pdf
PDF • 0.41 MB
finance_1659470.pdf
PDF • 0.41 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_1659470.pdf
PDF • 0.47 MB
AOC07.pdf
PDF • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .