Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹2.6 L
Closing Date
16 Apr 2021, 4:00 pmClosed
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2021_PWDJK_122246_1
Fresh e-NIT No.EDJ/01 of 2021-22 Dated 10-04-2021
Open Tender
Electrical Works
Item Rate
25 days
Sunderbani
please refer to NIT
2 documents required · 2 mandatory
₹0
Exempted
19 Apr 2021
10 Apr 2021
17 Apr 2021
11 Apr 2021
16 Apr 2021
11 Apr 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in partially laid surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing surface / recessed medium class PVC conduit G.I.boxand providing and fixing of, 2 way modular switch, modular plate and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 Sq. mm + 1 X 1.5 Sq. mm earth wire
2 X 2.5 Sq. mm + 1 X 2.5 Sq. mm earth wire
2 X 6 Sq. mm + 1 X 6 Sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
15/16 amp switch
Indicator 5/6Amp
5 Amp Plug Top
15 Amp. Plug Top
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and drawing 1x 1.5 sqmm FRLS PVC insulated copper conductor single core cable in th existing surface/ recess PVC conduit for invertor wiring as required
1X1.5 SQMM INVERTOR WIRING
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator).
16 way Double Door
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
SPN 63 Amp
Single Pole 6/10/16 Amp
Supply, installation, testing & commissioning CPRI Approvedof GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly and having ROHS certification GI Electrode Earthing should be maintinance free and does not require regular manual addition of water GI Electrode and providing and laying of 2 Nos. of 25 x 5 mm G.I strip from G.I rod upto the panel. The earthing pit should be covered with PVC cover.
Supplying and fixing of Angle/Batten Holder(Metal ring) polycarbonate including making complete connections etc as required alonhg-with providing and fixing of 15watt LED Bulbs (Havells).
Supply and fixing of led type 4 feet long batten tube light 20 Watt
Supplying & fixing 70 watt LED street/Flood light fitting with 10KV Built-in SPD complete with the suitable size of GI pipe bracket duly embedded in the wall/parapet including connections etc as required.
Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz including connections etc. as required.
Ceiling fan 1200 mm sweep
Providing and fixing of twin core PVC aluminium cable 16 sqmm.
Mohd Shafi
M/S VAARIS ENTERPRISE
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .