Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAccepted-Finance 334 1 SCHOOLDANGA BANKURA 722101 | BANKURA | WEST BENGAL | 722101 | L1 | Accepted-Finance 1st lowest bidder | |
| 2 | L2₹3.2 L+₹8,410 (2.67%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹4.0 L+₹84,405 (26.8%)Rejected-Finance GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | L3 | Rejected-Finance 3rd lowest bidder |
Tender Value
Refer Docs
EMD Value
₹12,019
Closing Date
14 Aug 2021, 2:00 pmClosed
Office of SE,SWEC,PWD, MIDNAPORE
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.D) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
Construction of Composite office building (Gplus3) under Consumer Affairs Department at Bankura-----Supply, Installation, Testing, and Commissioning of Fire Detection Annunciation system .
2021_WBPWD_337601_1
WBPWD/SE/SWEC/NIQ11/2021-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
BANKURA
Please refer Tender documents.
4 documents required · 4 mandatory
₹12,019
Office of SE / SWEC, PWD, Midnapore
22 Aug 2022
30 Jul 2021
16 Aug 2021
30 Jul 2021
14 Aug 2021
4 Aug 2021
3 Aug 2021
Amount
Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent optical -Thermal multi-criteria detector, Deatiled specification given in Annexure-A .(Approved make : Honeywell/ Siemens / Secutron/ Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton/GST).
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point (MCP).Deatiled specification given in Annexure-A (Approved make : Honeywell/ Siemens / Secutron/ Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton/GST).
Supply, Installation, Testing & Commissioning of Addressable sounders/ stobers/Hooters .Deatiled specification given in Annexure-A . (Approved make : Honeywell/ Siemens / Secutron/ Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton/GST)
Supply, Installation, Testing & Commissioning of Addressable Transponder and Control /Monitor Modules for monitoring flow switches/Fire exit doors /Lift / AHU etc complete as required.Deatiled specification given in Annexure-A (Approved make : Honeywell/ Siemens / Secutron/ Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton/GST)
Supply, Installation, Testing & Commissioning of Microprocessor based Intelligent Addressable Fire Alarm control Panel .(FACP) having expandable and fully networkable features suitable for handling all the detectors and devices for this project. It can be suitably configured according to the OEM loop capacity, Deatiled specification given in Annexure-A . (Approved make : Honeywell/ Siemens / Secutron/ Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton/GST).
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex / RR Kabel/ Polycab) with 20mm NB PVC rigid conduit pipe on the surface of the wall. (Make : Precission-Medium).Deatiled given in Annexure-A.
Supply, Installation, Testing & commissioning of of 7AH - 12 Volt DC battery for standby power supply system for Main FACP, (Make: Exide\Amaron/APC).Deatiled given in Annexure-A.
NOTE :1.The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2. Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done.3. As built drawing shall be submitted in Both soft (CAD) & hard copy format..Drawing shall be approved by the Engineer in charge before the commence of the work. 4. Necessary Certificate from the Competent Authority / Statutory body should be obtained by the executing agency if asked by EIC 5. The work shall be completed in all respect and shall be free from all kinds of defects/deficiencies/damages in equipment, materials, components and other auxiliaries and workmanship from any cause whatsoever for a period of Three years warrenty or, total replacement in case of major defects or fault for both the FACP and the battery. 6.Test Certificates of individual components may be produced if asked by EIC
MAM ENTERPRISE
GLYPTIC
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .