Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 CrAdmitted-Finance | ₹33.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹34.5 CrAdmitted-Finance | ₹34.5 Cr | L2 | Admitted-Finance |
| 3 | L3₹35.2 CrAdmitted-Finance | ₹35.2 Cr | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Guigui Kamei L3 | Yumkham Subhaschandra Meetei L2 | M/S KIM and Sons Constructions and Equipments L1 |
|---|---|---|---|---|---|---|
| 1.00SH (I) :- Civil Works | ||||||
| 2.00 | Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5 m including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m (a) Loose/soft soil. | 178.5 | cum | 120 ₹21,420 | 120 ₹21,420 | 120 ₹21,420 |
| 3.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. | 59.5 | cum | 120 ₹7,140 | 120 ₹7,140 | 120 ₹7,140 |
| 4.00 | Filling in plinth with sandy soil under floors i/c watering, ramming, consolidating and dressing complete | 479.33 | cum | 1,010 ₹4.8 L | 1,010 ₹4.8 L | 1,000 ₹4.8 L |
| 5.00 | Filling in plinth with granular material under floors including watering ramming, consolidating and dressing complete. | 200.45 | cum | 1,180 ₹2.4 L | 1,180 ₹2.4 L | 1,180 ₹2.4 L |
| 6.00 | Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering.mm size). a)1:4:8 (1cement:4 c/sand:8 graded stone aggt. 20 mm size) | 57.37 | cum | 9,450 ₹5.4 L | 9,450 ₹5.4 L | 9,190 ₹5.3 L |
| 7.00 | b)1:3:6(1cement:3 Kanhaighat c/sand:6 graded stone aggt. 20 mm size) | 186.15 | cum | 10,140 ₹18.9 L | 10,140 ₹18.9 L | 9,855 ₹18.3 L |
| 8.00 | Providing and laying Bitumen felt of approved quality. | 444.52 | sqm | 53 ₹23,559.56 | 53 ₹23,559.56 | 50 ₹22,226 |
| 9.00 | Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7 kg per sqm on damp-proof course after cleaning the surface with brushes and finnal with a piece of cloth lightly soaked in Kerosene oil. | 455.34 | sqm | 140 ₹63,747.60 | 140 ₹63,747.60 | 130 ₹59,194.20 |
| 10.00 | Reinforced cement concrete work in foundation footings, bases of columns etc. and mass concrete, excluding cost of centering, shuttering and reinforcement (a) 1:1:2 (1 Cement : 1 Kanhaighat coarse sand :2 graded stone aggregate 20 mm nominal size). | 64.44 | cum | 14,750 ₹9.5 L | 14,750 ₹9.5 L | 14,345 ₹9.2 L |
Tender Value
₹30.3 Cr
Closing Date
6 Apr 2021, 1:00 pmClosed
Executive Engineer-I, MPHC Ltd.
MANIPUR POLICE HOUSING CORPORATION LIMITED (A GOVT. OF MANIPUR UNDERTAKING) IMPHAL, MANIPUR.
Setting up of IT-SEZ Building - I (Balance Work) (SH I. Civil work. SH II. Electrical and Allied Works).
2021_MPHCL_1319_1
No. e-Tender 12/EE-I/MPHC/2020-21
Open Tender
Civil Works
365 days
As Per Tender Document
Please refer Tender documents.
11 documents required · 11 mandatory
₹25,000
A/C of MPHC Ltd. Imphal.
Exempted
27 Jul 2023
16 Mar 2021
6 Apr 2021
17 Mar 2021
6 Apr 2021
28 Mar 2021
18 Mar 2021 - 27 Mar 2021
Amount
SH (I) :- Civil Works
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5 m including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m (a) Loose/soft soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Filling in plinth with sandy soil under floors i/c watering, ramming, consolidating and dressing complete
Filling in plinth with granular material under floors including watering ramming, consolidating and dressing complete.
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering.mm size). a)1:4:8 (1cement:4 c/sand:8 graded stone aggt. 20 mm size)
b)1:3:6(1cement:3 Kanhaighat c/sand:6 graded stone aggt. 20 mm size)
Providing and laying Bitumen felt of approved quality.
Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7 kg per sqm on damp-proof course after cleaning the surface with brushes and finnal with a piece of cloth lightly soaked in Kerosene oil.
Reinforced cement concrete work in foundation footings, bases of columns etc. and mass concrete, excluding cost of centering, shuttering and reinforcement (a) 1:1:2 (1 Cement : 1 Kanhaighat coarse sand :2 graded stone aggregate 20 mm nominal size).
Extra for layingconctrete in or under water and /or liquid mud i/c cost of pumping or bailing out water and removing slush etc. complete.
Reinforced Cement Concrete work in walls (any thickness) i/c attached plasters, buttresses, plinth & string courses, filets etc upto floor two level but excluding the cost of centering and shuttering & reinforcement.(a) 1:1:2 (1 Cement : 1 Kanhaighat coarse sand :2 graded stone aggregate 20 mm nominal size). (a) Upto floor two level
(b).Above floor two level
(c).Second floor level
(d).Third floor level
(e).Fourth floor level
(f).Fifth floor level
(g).Terrace floor level
Reinforced cement concrete work in suspended floors, roofs landing,shelves & their supports balconies, lintels,beams, plinth beams, girders, bressumers and cantilevers upto floor two level excluding cost of centering, shuttering and reinforcement.(a) 1:1:2 (1 Cement : 1 Kanhaighat coarse sand :2 graded stone aggregate 20 mm nominal size). (a) Upto floor two level
(b).Above floor two level
(c).Third floor level
(d).Fourth floor level
(e).Fifth floor level
(f).Terrace floor level
(g).Mumty floor level
(h).Machine Room level
Reinforced cement concrete work in columns, pillars, piers, abutments, post and struts upto floor two level but excluding the cost of centering-shuttering & reinforcement. (a) 1:1:2 (1 Cement : 1 Kanhaighat coarse sand :2 graded stone aggregate 20 mm nominal size).size). (a) Upto floor two level
(b)Above floor two level
C) Second Floor level
(d)Third Floor level
(e)Fourth Floor level
(f)Fifth Floor level
(g)Terrace floor level
(h)Mumty level
Reinforced Cement Concrete work in staircase (excluding landing) except spiral staircase i/c finishing and plastering the exposed surfaces with cement mortar 1:3 (1 cement:3-fine sand) to give a smooth and even surface preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centering, shuttering and reinforment with (a) 1:1:2 (1 Cement : 1 Kanhaighat coarse sand :2 graded stone aggregate 20 mm nominal size). (a).Upto floor two level.
(b)Above floor two level
c)Second Floor level
d)Third Floor level
e)Fourth Floor level
f)Fifth Floor level
(g)Terrace floor level
(h)Mumty level
Extra for providing and mixing water proofing materials in cement concrete work in the proportion recommended by manufactures
Reinforcement for RCC work I/c bending binding and placing in positionA). Tor steel bar
Applying cement slurry in R.C.C. slabs or cement concrete work using 2.75 kg/sqm for receiving cement concrete floor i/c roughening, cleaning etc complete.
Providing form works i/c centering and shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 m and removal of the same for in-situ reinforced concrete and plain concrete work in (Using 12mm shuttering ply) a). Foundation,footings,bases of columns etc.and mass concrete
b). Flat surface such as soffits of suspended floors,roofs landings and the like.(a)floors etc. upto 200 mm in thickness
c). Columns, pillars , post and struts (square, rectangularor polygon in plain)
e).Sides and sofitt of beams , beam haunching, cantilevers , girders,bressumers and lintels not exceeding 1m in depth.
f).Staircase with sloping or stepped, soffits i/c risers and stringes excluding landing.
g).Vertical surface such as wall (any thickness), partitions and the like i/c attached pilasters, buttresses, plinth & string courses and the like
h)Edges of slab and breaks in floor walls i)under 20 cm wide
2nd class (Local first class) brickwork in foundation and plinth in cement mortar 1:3(1cement :3 Kanhaighat coarse sand)
Extra for brick work in superstructure above plinth level upto 1st floor.
2nd class (Local first class) brickwork in superstructure in cement mortar 1:3(1cement :3 Kanhaighat coarse sand). (a).First floor level
(b).Second floor level
(c).Third floor level
(d).Fourth floor level
(e).Fifth floor level
(f) Terrace floor level
(g) Mumty level
Half brick masonry 2 nd class (Local first class) in cement mortar 1:3(1cement :3 Kanhaighat coarse sand) in superstructure. (a) Upto Floor two level
(b).First floor level
(c).Second floor
(d).Third floor level
(e).Fourth floor level
(f).Fifth floor level
(g).Terrace floor level
Providing and fixing stainles steel railing complete as per Architectural drawing and design.
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing and laying 80 mm thick factory made cement concrete interlocking paver block (Rubber Moulded) of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design / shape laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand etc. all complete as per the direction of the Engineer-in-charge.
Granite stone slab flooring over 20 mm( average ) thick base of cement mortar 1 : 6 ( 1 cement : 6 coarse sand ) laid and jointed with grey cement slurry including rubbing and polishing complete with -Granite slab 20 mm slab thick.(A)60 X 120 cm
12.5 mm thick granite tiles in risers of steps , skirting , dado walls and pillars laid on 10 mm thick base of cement mortar 1 : 3 ( 1 cement: 3 coarse sand ) laid and jointed with grey cement slurry including rubbing and polishing complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 20 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), including grouting the joint with white cement& matching pigments etc. complete. 600x600mm Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 20 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), including grouting the joint with white cement& matching pigments etc. complete. 600x600mm
Extra for nosing in granite stone for treads
Providing and laying non skid vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.
Colour glazed tiles 10 mm thick in skirting risers of steps & dado on 10 mm thick cement plaster 1:3(1 cement:3 coarse sand) & jointed with white cement slurry.
P/F false ceiling at all height i/c providing and fixing of frame work made of special sections,power pressed from M.S. sheets and galvanised with zinc coating of 120gm/sqm(both side inclusive)as per IS 277 and consisting of angle cleats of size 25mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm,at 1200 mm c/c,one flanged fixed to the ceiling with dash fastener 12.5 mm dia. x 50 mm long with 6 mm dia. bolts,other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and and other end of hanger fixed with intermediate G.I. channels 45x 15 x 0.9mm running at the spacing of 1200 mm c/c,to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm,at 450mm c/c,shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia. x 230mm long G.I. wire at every junction,i/c fixing perimeter channels 0.5 mm thick 27mm high having flangrs of 20mm and 30mm long,the perimeter of ceiling fixed to the wall/partition with the help of rawl plugs at 450mm centre,with 25mm long dry wall screws @ 230mm interval,i/c fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screwsof size 3.5x25mm at 230mm c/c i/c jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes,finishing with jointing compoung in 3 layers covering upto 150mm on both sides of the joint and two coats of primer suitable for the board,all as per manufacturer's specification and also i/c the cost of making openings for light fittings,grills,diffusers,cutouts made with frame of perimeter channels suitably fixed,all complete as per drawings,specifications and direction of the Engineer in charge but excluding the cost of painting with (II) 12.5 mm thick tapered edge Mineral fibre board (Armstrong brand Dune RH99)
Providing & fixing on wall face PVC(Double socketed) rain water pipe i/c filling the joints with spun yarn soaked in neat cement slurry & cement mortar 1:2(1 cement:2 fine sand).(a).100mm dia
Providing & fixing M.S. holder bat clamps embedded in & i/c cement concrete blocks 112.5 mm X 112.5 mm of 1:2:4 mix (1 cement:2 coarse sand:4 hard stone bollast 20 mm & down gauge).
Supply,fabrication and erection of uPVC Doors,Widows of required size as per Architectural design fixed with fixing clips or with expansion hold fasteners i/c filling up gaps at top, bottom and sides with required gasket etc. with 5mm clear Non Toughened Glass with sealant in between the joint to make leak proof complete. a).Dark Oak Colour Classic Premuim Series.
Providing and fixing 5mm colour coated structural glazing with Black anodized nose aluminium section with 5mm thick tempered color gass (sub frame to be fixed on mother frame)etcc. complete as per the architectural drawings and the directions of engineer-in-charge. a)-With structural glass panes of 5mm thickness
12 mm cement plaster 1:3 (1 cement:3 Dhanshree fine sand).
15 mm cement plaster 1:3 (1 cement:3 Dhanshree fine sand).
Painting on wall with (two coats) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
30 mm thick ferrocement roof treatment (Wooden float finished) in cement mortar 1:3 (1cement:3 coarse sand) on top of roof reinforced with a layer of M.S. wire mesh/M.S. expanded metal 20x6mm strands separated by 6 mm dia M.S.Rod @ 75cm c/c applying two coat of water proofing membrane of approved quality
Providing, mixing and applying priming coat of approved polymer bonding as per specification and direction of Engineer-in-Charge complete
Supply and fixing of Aluminium Composite panel of standard make mounted on aluminium frames in tray system complete with all necessary fixing arrangement,joints sealed with structural sealant Dow Corning or wacker silicon 789 or approved quality complete with . A.3mmx0.25mm board using aluminium hollow rectangular section. I)..50x25x1.20mm
Steel work in built up trusses including cutting , hoisting , fitting in position & applying a coat of approved steel primer red oxide zinc chrome primer conforming to IS : 2074 - 1979 welded & bolted including special washer etc. complete., a ) Electric resistant welded tube (Conforming to IS : 1611- 1979 )
Corrugated Fibre Sheet 24 B.G. fixed with galvanised iron J or L hooks 8 mm dia G.I. limpet & bitumen washer complete, excluding the coat of purlins rafter & trusses.
Providing toughned and laminated glass sheet roofing 6mm thick with necessary fittings as directed by the Engineer in Charge i/c fixing devices as required on slope roof e/c the cost of trusses and purlins.
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm nominal size) in pavement roads taxi-tracks and runaways laid to be required slopes and camber including compaction, tamping, finishing and curing complete.
Providing and fixing white glazed European type water closet pane Indian make with 10 cm HCI trap 12.5 litre low level C.I. flushing cistern of approved made with fittings R.S or C.I brackets 32 mm diameter telescopic flush pipe with fittings and clamps 25 mm G.I. overflow pipe with spiral & mosquito proof coupling of approved Municipal design G.I. pull-chain complete i/c painting of cistern & fittings cutting and making good the walls & floors. a)W.C.pan with ISI marked black solid plastic seat and lid
Providing and Fixing wash basin of white glazed earthen ware (Indian make) with R.S. or C.I. brackets painted white 1 central 12.5 mm C.P. brass pillar tapes, 32 mm rubber plugs and C.P. brass chain 32 mm C.P. brass waist-of standard pattern 32 mm diameter M.I. or C.P. brass traps and unions complete i/c cutting and making good the walls (Indian fittings). (a) 630 x 450 mm
Providing and fixing urinal basin of white glazed earthen ware Indian make with 5.0 L. C.I. automatic flushing cistern with fittings R.S. or C.I. brackets standard size flush pipe spreader with brass union & G.I. clamps complete i/c painting of cistern & fittings, cutting & making good the walls and floors. (a) Flat back Urinal (i) 610 x 400 x 380 mm
Providing and fixing soap container of glass with C.P. lid and brackets fixed to wooden cleats with C.P. brass screws.
Providing and fixing 600 x 450 mm bevelled edge mirror of Indian make superior glass (of approved quality) quality complete with asbestos sheet ground, fixed to wooden cleat with C.P. brass screws and washers.
Providing and fixing 610 x 20 mm Diplomat brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screws
Providing and fixing C.P. brass toilet paper holder
Providing and fixing brass stop cock of superior quality. (a) 25 mm diameter
Providing and fixing C.P. bib cock of superior quality. (a) 20 mm diameter (Delux Sona)
Providing and fixing 100 mm H.C.I. soil vent pipes. (a) 100 dia pipe
Providing and fixing WATER STORAGE TANKS (Sintex) G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube i/c hoisting a height of 10 m above ground level. (a) 2000 litres net capacity storage tanks
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR 7.4 UV stabilized & anti-microbial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings i/c trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (External work). (a) PN- pipe, 40 mm OD
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR 7.4 UV stabilized & anti-microbial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings i/c fixing the pipe the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,). (a) 25 mm dia
(b) 16 mm dia
P/F PVC soil waste and vent pipe (external). (a) 160 mm dia
P/f PVC soil waste and vent pipe (internal) (a) 110 mm dia
P/F PVC traps with 100 mm inlet and 100 mm outlet of self cleaning design with HCI screwed down of hinged grating with or without vent arm complete i/c cost of cutting and making good the walls and floors.
P/F 160 x 160 x110 mm PVC branch of the reqd. degree with access doors, insertion rubber washer 3 mm thick bolts and nuts complete.
P/F 100 mm PVC bend of the required degree with access door insertion rubber washers bolts and nuts etc. complete..
P/F 160 mm PVC bend of the required degree with access door insertion rubber washers bolts and nuts etc. complete.
P/F 100 x 100 x 100 mm PVC branch of the reqd. degree with access doors, insertion rubber washer 3 mm thick bolts and nuts complete.
Providing and fixing 20 mm thick Teak wood panelling over wooden frame work consisting of batten 50 mm x 38 mm and finishing work complete.
B. Ground Sump & Drain Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5 metres including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres. H/D soil
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering.1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Reinforced cement concrete work in walls (any thickness) i/c attached pilasters, buttresses, plinth and string courses, fillets etc. upto floor two level i/c finishing and plastering the exposed surface with cement mortar (1:3) (1 cement: 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.1:1:2 (1 cement: 1 coarse sand: 2 graded stone aggregate 20 mm nominal size).
Reinforcement for RCC work i/c bending , binding and placing in position complete in Tor-steel bars
Providing form works i/c centering and shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 m and removal of the same for in-situ reinforced concrete and plain concrete work in (a)Vertical surface such as walls (any thickness), partition and the like i/c attached pilasters, buttresses, plinth and the string courses and the like
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:3 (1 cement: 3 coarse sand)
15mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
C) : Construction of Septic Tank E/work in excavation in foundation, trenches or drains i/c dressing of sides and ramming of bottom lift upto 1.50 m i/c getting out the excavated soil and disposal of surplus soil as directed within a lead of 50m (a) Hard/dense soil.
Providing and laying cement concrete in foundation & plinth excluding the cost of centering & shuttering. a) 1 : 4 : 8 (1 Cement: 4 coarse sand: 8 graded stone aggregate: 40 mm nominal size).
b) 1:2:4 (1cement:3 Kanhaighat c/sand:6 graded stone aggt. 20 mm size)
Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7 kg per sqm on damp-proof course after cleaning the surface with brushes and finnal with a piece of cloth lightly soaked in Kerosene oil.
Reinforced cement concrete work in foundation footings, bases of columns etc. and mass concrete, excluding cost of centering, shuttering and reinforcement, a)1:1:2 (1 cement: 1 coarse sand: 2 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness) i/c attached pilasters, buttresses, plinth and string courses, fillets etc. upto floor two level but excluding cost of centering, shuttering and reinforcement. a)1:1:2 (1 cement: 1 coarse sand: 2 graded stone aggregate 20 mm nominal size).
Reinforced Cement Concrete work in suspended floors, roofs landing, shelves & their supports balconies, lintels, beams, plinth beams, girders, bressumers and cantilevers upto floor two level but excluding cost of centering, shuttering and reinforcement a)1:1:2 (1 cement: 1 coarse sand: 2 graded stone aggregate 20 mm nominal size). a) 1 : 1.5 : 3 (1 cement :1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Applying cement slurry in R.C.C. slabs or cement concrete work using 2.75 kg/sqm for receiving cement concrete floor i/c roughening, cleaning etc complete.
Reinforcement for R.C.C. work i/c. bending, binding and placing in position complete a) Tor steel bars.
Providing form works i/c centering and shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 m and removal of the same for in-situ reinforced concrete and plain concrete work in (Using 12mm shuttering ply). a). Foundation,footings,bases of columns etc.and mass concrete.
b) Flat surface such as suspended floor, roofs landings and the like i)floors etc. upto 200 mm in thickness
g).Vertical surface such as wall (any thickness), partitions and the like i/c attached pilasters, buttresses, plinth & string courses and the like
e).Sides and sofitt of beams , beam haunching, cantilevers , girders,bressumers and lintels not exceeding 1m in depth.
c)Edgesof slabs and breaksin floor walls i) Under 20cms wide.
2nd class (local first class)brickwork in cement mortar 1:3(1cement :3 Kanhaighat coarse sand) in superstructure.
Honeycomb brick work (75 mm) thick with first class brick in cement mortar 1:4 (1 cement: 4 coarse sand)
Proving and fixing C.I. cover for manhole and chambers. (a) 600 x 450 (heavy duty 38kg).
15 mm cement plaster 1:3 (1 cement:3 dhanashree fine sand) finished with a floating coat of neat cement.
Providing and fixing HCI traps with 100 mm inlet and 100 mm outlet of self cleaning design with HCI screwed down of hinged grating with or without vent arm complete i/c cost of cutting and making good the walls and floors.
Providing and fixing 100 mm HCI terminal guard.
Providing and fixing 100 mm HCI collar
SH (III):- Electrical & Allied Works
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit with modular type switch, modular plate suitable size GI box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as reqd.
1. Group A
2. Group B
3. Group C
Wirig for twin control light point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way switch, modular plate, modular type switch stuitable size GI box and earthing the point with 1.5mm2 FR, PVC insulated copper conductor single cre cable etc.
Wiring for light point / power plug with 2x4mm2 FR PVC insulated copper conductor single core cable in surface / recessed PVC along with 1 no. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing as reqd.
Wiring for light point / power plug with 4x4mm2 FR PVC insulated copper conductor single core cable in surface / recessed PVC along with 1 no. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing as reqd.
Wiring for power plug with 2x6mm2 FR PVC insulated copper conductor single core cable in surface / recessed PVC along with 1 no. 6mm2 FR PVC insulated copper conductor single core cable for loop earthing as reqd.
Wiring for Circuit / Sub main wiring along with earth wire with ( the following sizes of ) FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit etc, as reqd. (a) 2x1.5mm2 + 1x 1.5 mm 2 earth wire
(b) 2x2.5mm2 + 1x 2.5 mm 2 earth wire
(c) 2x4mm2 + 1x 4 mm 2 earth wire
(d) 4x4mm2 + 2x 4 mm 2 earth wire
(e) 4x6mm2 + 2x 6 mm 2 earth wire
S/F Pre-coated electronic box type luminaries with decorative and caps FTL 1x36/40w lamp complete with all accessories i/c connection etc, as reqd.
S/F Surface / recess mounting extracted aluminum CFL mirror optics luminariesHSG superior finish extracted aluminum body anodized aluminum reflector(BJSM-218 CFL).
S/F Vertical down lighter with CFL 1x10/13 white powder coated CRCA ring, bright finished reflector i/c connection etc. (Ref.538536 BJDR 110/113 WEB/VI, D type CFL 1x10/13W).
S/E Wall/ Ceiling mounting T5 lamp luminaries T5 1x14W for task/Accent light grey powder coated elegant designed extracted aluminum housing with swivel type arrangement (BJHL-114T5SL).
S/F Horizontal down lighter D type CFL 2x18 white powder coated CRCA ring, bright finished reflector (Ref.530806, BJDR 218 HW 2EB/complete with connection etc.
S/F 48” sweep (1400mm) AC ceiling fan complete with down rod canopy 3( three) blades but without regulator etc as reqd.
S/F stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc.
S/F 305mm sweep exhaust fan complete with all accessories i/c connection etc.
S/F (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc, as reqd. (a) 5/6 amps switch
(b) 15/16 amps swich
(c)5/6 amps socket outlet
(d) 15/16 amps socket outlet
(e) 2 way 5/6 amp switch
S/F following module (125mm x75mm) GI box along with modular base and cover plate for modular switch in recess as reqd (a). 4 way
(b). 1 or 2 way
Supply installation and commissioning of Industrial type Metal clad20A, 230V plug socket, 20A DP MCB with etal enclosure complete with wiring, pin, cap, chain etc.
S/F (Following way) 3 pole and neutral,sheet steel MCB distribution board, 240V on surface/ recessed complete with tinned copper bus bar neutral bus bar,earth bar, din bar, detachable gland plate, interconnection, phosphatized and powder paintedincluding earthing etc, as reqd. (but without MCB/ RCCB/ Isolator). (a). 6 way (4+18 single door horizontal type.
(b). 4 way (4+12 single door horizontal type.
P/F (following ratting 3 pole 230V0) moulded case circuit breakers (MCCB) AC-415V having a sensitive current up to 300 MA in the existing MCB DB complete with connection testing and commissioning etc, (a). 25 Amp up to 50 amp 3 pole 230V 300MA
S/F 5 amp to 32 amp rating 230V ‘B’ series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc, as reqd. (a). Single pole
S/F (following way) single/double pole and neutral, sheet steel MCCB distribution board, 240V on surface / recessed complete with tinned copper bus bar neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphatized and powder painted including earthing etc, as reqd (but without MCB/RCCB/Isolator). (a). 8 way single door.
S/F Double pole 20 amp rating 230V ‘B’ series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc, as reqd.
MAIN POWER PANEL (Loc: OUTDOOR SUBSTATION ELECTRIC ROOM)
Supply Installation testing commissioning of main electrical switch / panel board fabrigated with 14/16G CRCA sheet steel, with standard pre-treatments, pre-coats on anti rust paint and finished with powder coating to the approval of consultants.The panel shall be self powered for trip relay to function independently and panel shall be suitable for indoor installation, Inter locking system as per operation philosophy.which consist the following incoming and out going components.
IN COMING:-
i. 2000 A 4P EDO for EB & DG i/c - 3 nos.
ii. RYB indication lamp 3 Set.
iii. KWH meter with CT (withRS-484 port) 3 Set.
iv. Digital multimeter for A.V.F to measure single phase &3 phase parameters 3 Set.
v. EF/OC relay 3 Set.
vi. UV/OV relay 3 Set.
vii. ELR with CBCT 3 Set.
viii. TPN aluminum sleeved bus bar set 2500 Amp. rated. 1 Set.
OUT GOING
1. i. 1000A 4P EDO ACB with Microprocessor control for Main L.T. panel 1 no.
ii. RYB indication lamp 1 Set
iii. Digital multimeter for A.V.F to measure single phase &3 phase parameters 1 No.
iv. ELR with CBCT 1 Set
2. i. 1000A 4P EDO ACB with Microprocessor control for AC panel 1 no.
ii. RYB indication lamp 1 Set.
iii. KWH meter with CT (withRS-484 port) 1 Set.
iv. Digital multimeter for A.V.F to measure single phase &3 phase parameters 1 No.
v. ELR with CBCT 1 Set
3. i. 800A 4P MCCB with Microprocessor control for capacitor panel 1 no.
ii. RYB indication lamp 1 Set.
iii. 12 chanel APFC controller with matched CT- 1 Set.
iv. Digital multimeter for A.V.F to measure single phase &3 phase parameters 1 No.
v. ELR with CBCT 1 Set
4. 63 Amp TPN MCB for OLTC etc. 5 nos
MAIN LT PANEL (GROUND FLOOR ELECTRICAL ROOM)
Supply Installation testing commissioning of main electrical switch board of fabrigated with 14/16G CRCA sheet steel, with standard pre-treatments, pre-coats on anti rust paint and finished with powder coating to the approval of consultants.The panel shall be self powered for trip relay to function independently and panel shall be suitable for indoor installation, Panel shall be to the specicifications, drawing and to the approval of Architect/ Consaltant.
IN COMING:-
i. 1000 A 4P EDO ACB 1 no.
ii. RYB indication lamp 1 Set.
iii. KWH meter with CT (withRS-484 port) 1 Set.
iv. Digital multimeter for A.V.F to measure single phase &3 phase parameters 1Set.
v. EF/OC relay 1 Set.
vi. UV/OV with relay 1 Set.
vii. ELR with CBCT 1 Set.
viii. TPN aluminum sleeved bus bar set 2500 Amp. rated. 1 Set.
OUT GOING
1. i. 630A TPN MCCB with Microprocessor control for Main Distribution panel 1 no.
ii. RYB indication lamp 1 Set
iii. KWH meter with CT (withRS-484 port) 1 Set.
iv. Digital multimeter for A.V.F to measure single phase &3 phase parameters 1No.
v. ELR with CBCT 1 Set
2. i. 630A TPN MCCB with Microprocessor control for Essential load panel (Lifts, STP, Fire, UPS, Em- lighting, Pump panel) 1 no.
ii. RYB indication lamp 1 Set.
iii. KWH meter with CT (withRS-484 port) 1 Set.
iv. Digital multimeter for A.V.F to measure single phase &3 phase parameters 1No.
v. ELR with CBCT 1 Set.
3. i. 400A TPN MCCB with Microprocessor control for future 1 no.
ii. RYB indication lamp 1 Set.
iii. KWH meter with CT (withRS-484 port) 1 Set..
iv. Digital multimeter for A.V.F to measure single phase &3 phase parameters 1 No.
v. ELR with CBCT 1 Set
4. i. 250A TPN MCCB with Microprocessor control for spare 1 no.
ii. RYB indication lamp 1 Set.
iii. KWH meter with CT (withRS-484 port) 1 Set..
iv. Digital multimeter for A.V.F to measure single phase &3 phase parameters 1 No.
v. ELR with CBCT 1 Set.
5. 63 Amp TPN MCB spare 4 nos.
Supply Installation testing commissioning of main electrical switch / panel board fabrigated with16G CRCA sheet steel, with standard pre-treatments, pre-coats on anti rust paint and finished with powder coating to the approval of consultants.The panel shall be self powered for trip relay to function independently and panel shall be suitable for indoor installation, Inter locking system as per operation philosophy.which consist the following incoming and out going components.
IN COMING:-
i. 800 A TPN MCCB Microprocessor based 1 no.
ii. RYB indication lamp 1 Set.
iii. Digital multimeter for A.V.F to measure single phase &3 phase parameters1 Set.
iv. 12 channel APFCR 1 no.
v. TPN aluminum sleeved bus bar set 1000 Amp. rated. 1 Set.
OUT GOING
i. 200A rated , 25 KA FCI TP&N, MCCB 2 nos
ii. 100A rated , 25 KA FCI TP&N, MCCB 2 nos
iii. 63A rated , 25 KA FCI TP&N, MCCB 4 nos
iv. 100 KVAR rated capacitor 2nos.
v. 50 KVAR rated capacitor 2nos
vi. 25 KVAR rated capacitor 4nos
vii. 200 A TP&N contactor with O/L release 2 nos.
viii. 100 A TP&N contactor with O/L release 2 nos.
ix. 50 A TP&N contactor with O/L release 4 nos
x. OFF/ON built in illuminated PB 8 Sets.
xi. 7% de-tuned inductive filter 8 nos. exhaust fans for each capacitor compartment 8 nos.
Supply Installation testing commissioning of main distribution panel board fabrigated with16G CRCA sheet steel, with standard pre-treatments, pre-coats on anti rust paint and finished with powder coating to the approval of consultants.The panel shall be self powered for trip relay to function independently and panel shall be suitable for indoor installation, Inter locking system as per operation philosophy.which consist the following incoming and out going components.
IN COMING:-
i. 630 A 4 pole COS 1 no.
ii. 630 A TPN MCCB Microprocessor based 1 no.
iii. RYB indication lamp 1 Set.
iv. Digital multimeter for A.V.F to measure single phase & 3 phase parameters 1 no.
v. EF/OC relay 1 no.
vi. UV/OV relay 1 no.
vii. ELR with CBCT 1 Set.
TPN aluminum sleeved bus bar 100A rated 1 Set.
OUT GOING
i. 160 A TPN MCCB for fire panels 1no.
ii. 125 A TPN MCCB for UPS panels 2 nos
iii. 100 A TPN MCCB for STP, Pump panels 4 nos.
Supply Installation testing commissioning of main distribution panel board fabrigated with16G CRCA sheet steel, with standard pre-treatments, pre-coats on anti rust paint and finished with powder coating to the approval of consultants.The panel shall be self powered for trip relay to function independently and panel shall be suitable for indoor installation, Inter locking system as per operation philosophy.which consist the following incoming and out going components.
IN COMING:-
i. 630 A TPN MCCB Microprocessor based 1 no.
ii. RYB indication lamp 1 Set.
iii. Digital multimeter for A.V.F to measure single phase & 3 phase parameters 1 no.
iv. EF/OC relay 1 no.
v. UV/OV relay 1 no.
vi. ELR with CBCT 1 Set.
vii. TPN aluminum sleeved bus bar 100A rated 1 Set.
OUT GOING
i. 63 A TPN MCCB for floor distribution panels 15 nos.
ii. 40A TPN MCB for basement/other LDBs 3 nos.
Supply Installation testing commissioning of main distribution panel board fabrigated with16G CRCA sheet steel, with standard pre-treatments, pre-coats on anti rust paint and finished with powder coating to the approval of consultants.The panel shall be self powered for trip relay to function independently and panel shall be suitable for indoor installation, Inter locking system as per operation philosophy.which consist the following incoming and out going components.
IN COMING:-
i. 63 A TPN MCCB 1 no.
iii. RYB indication lamp 1 Set.
iv. Digital multimeter for A.V.F to measure single phase & 3 phase parameters 1 no.
v. ELR with CBCT 1 Set.
vi. TPN aluminum sleeved bus bar 100A rated 1 Set.
OUT GOING
i. 40 A TPN MCCB for PDBs 3 nos. ii. 32A TPN MCB for LDBs 3 nos.
Supply Installation testing commissioning of main distribution panel board fabrigated with16G CRCA sheet steel, with standard pre-treatments, pre-coats on anti rust paint and finished with powder coating to the approval of consultants.The panel shall be self powered for trip relay to function independently and panel shall be suitable for indoor installation, Inter locking system as per operation philosophy.which consist the following incoming and out going components.
IN COMING:-
i. 125 A TPN MCCB 1 no.
ii. RYB indication lamp 1 Set.
iii. Digital multimeter for A.V.F to measure single phase & 3 phase parameters 1 no.
iv. ELR with CBCT 1 Set.
v. TPN aluminum sleeved bus bar 250A rated 1 Set.
OUT GOING
i. 63 A TPN MCCB for PDBs 7 nos for UPS floor distribution panels
Supply Installation testing commissioning of main distribution panel board fabrigated with16G CRCA sheet steel, with standard pre-treatments, pre-coats on anti rust paint and finished with powder coating to the approval of consultants.The panel shall be self powered for trip relay to function independently and panel shall be suitable for indoor installation, Inter locking system as per operation philosophy.which consist the following incoming and out going components.
IN COMING:-
i. 63 A TPN MCCB 1 no.
ii. RYB indication lamp 1 Set.
iii. Digital multimeter for A.V.F to measure single phase & 3 phase parameters 1 no.
iv. ELR with CBCT 1 Set.
v. TPN aluminum sleeved bus bar 250A rated 1 Set.
OUT GOING
i. 32 A TPN MCCB for PDBs 7 nos for UPS DBs
Supply & Laying of 400 sq.mm 3.5 core 1100V rated armoured aluminum conductor PVC insulated cable (Unistar/KEI/ Havells/Polycab make)
Supply & Laying of 400 sq.mm 3.5 core 1100V rated armoured aluminum conductor PVC insulated cable (Unistar/KEI/ Havells/Polycab make)
Supply & Laying of 300 sq.mm 3.5 core 1100V rated armoured aluminum conductor PVC insulated cable (Unistar/KEI/ Havells/Polycab make)
Supply & Laying of 240 sq.mm 3.5 core 1100V rated armoured aluminum conductor PVC insulated cable (Unistar/KEI/ Havells/Polycab make)
Supply & Laying of 25 sq.mm 4 core 1100V rated armoured aluminum conductor PVC insulated cable .
Supply & Laying of 50 sq.mm 3.5 core 1100V rated armoured aluminum conductor PVC insulated cable .
Supply & Laying of 10 sq.mm 4 core 1100V rated armoured aluminum conductor PVC insulated cable .
Supply & Laying of 150 sq.mm 3.5 core 1100V rated armoured aluminum conductor PVC insulated cable .(Unistar/KEI/ Havells/Polycab make)
Supply & Laying of 16 sq.mm 4 core 1100V rated armoured aluminum conductor PVC insulated cable
Laying & Fixing of 1 no.PVC insulated PVC sheathed power cable of 1.1KV grade of size not less than 25 sq.mm but not exceeding 120sq.mm on surface as reqd.
Laying & Fixing of 1 no.PVC insulated PVC sheathed power cable of 1.1KV grade of size not less than 120 sq.mm but not exceeding 400sq.mm on surface as reqd.
Laying of 1 no. PVC insulated PVC sheathed power cable of 1.1KV grade of size not less than 25 sq.mm direct in ground i/c excavation sand cushioning protective covering and refilling the trenches etc.
Laying of 1 no. PVC insulated PVC sheathed power cable of 1.1KV grade of size not less than 25 sq.mm but not exceeding 120 sq.mm direct in ground i/c excavation sand cushioning protective covering and refilling the trenches etc.
Laying of 1 no. PVC insulated PVC sheathed power cable of 1.1KV grade of size not less than 120 sq.mm but not exceeding 400 sq.mm direct in ground i/c excavation sand cushioning protective covering and refilling the trenches etc.
Laying of 1 no. additional PVC insulated PVC sheathed power cable of 1.1KV grade of size not less than 25 sq.mm but not exceeding 120sq.mm direct in same trench in one tier horizontal formation i/c excavation, sand cushioning, protective covering and refilling the trench etc.
Laying of 1 no. additional PVC insulated PVC sheathed power cable of 1.1KV grade of size not less than 120 sq.mm but not exceeding 400sq.mm direct in same trench in one tier horizontal formation i/c excavation, sand cushioning, protective covering and refilling the trench etc.
Supply & laying of 4 core 16 sq.mm PVC insulated PVC sheathed (H/duty)armoured cable with aluminum conductor for working voltage 1100 V IS : 1554 (Pt-I)from transformer OLTC to Main power panel in LT room for Tap changer power ( Unistar/ KEI/ Havells/Polycap make only).
Supply & laying of 18C 2.5 sq.mm PVC insulated PVC sheathed (H/duty) armoured cable with copper conductor for working voltage 1100 V IS : 1554 (Pt-I) from transformer OLTC to RTCC for Tap position indication in LT room ( Unistar/ KEI/ Havells/Polycap make only).
Supply & laying of 4 core 4 sq.mm armoured PVC insulated copper cable for linking transformer marshalling box and OLTC & VCB ( Unistar/ KEI/ Havells/Polycap make only).
CABLE TERMINATION.
Supplying and making end termination with glands including aluminum/copper lugs and other joining materials for following size of PVC insl. And PVC sheathed/XLPE aluminum/copper conductor cables 1100V gradxe multicore. 1. 3.5C 400 sq.mm size for PVCA cable with aluminum lugs end termination.
2. 3.5C 300 sq.mm size for PVCA cable with aluminum lugs end termination
3. 3.5C 185/240 sq.mm size for PVCA cable with aluminum lugs end termination
4. 3.5C 150 sq.mm size for PVCA cable with aluminum lugs end termination
5. 3.5C 50 sq.mm size for PVCA cable with aluminum lugs end termination
6. 3.5C 25 sq.mm size for PVCA cable with aluminum lugs end termination
7. 3.5C 16 sq.mm size for PVCA cable with aluminum lugs end termination
8. 3.5C 10 sq.mm size for PVC cable with copper lugs end termination
9. 18C 2.5 sq.mm size for copper cable with lugs end termination.
10. 4C 2.5 sq.mm size for copper cable with lugs end termination.
Supply fabrication installation of steel support elements/ laddertype cable tray etc. for installation using light MS sections including 3 course of anti rust paint and two coats of finish colour.
Construction of cable trench with brick wall and covered with precast heavy RCC slab permiting heavy truck passage. The trench shall have 50x5 ms ISA grouted into both side of the walls with flat surface top at an interval of 1000mm in2 tiers for cable support as per drawing & specification. a. 1000wx1000d for Transformer/Kiosk/Panel
b. 600wx1000d for incoming – RM/HTPanels
c. 450wx1000d for DG/AMF/Power Panels
Making cable trench excavating in each of size—providing 10cm sand cushion below and above the cable, covering further with class-1 burnt bricks protection and back filling to neighbouring levels for HT cables. a. 450wx750d for AC plant/Main LT panel/Maoin power panel.
b. 3000wx750d for External lighting
Supply Installation testing commissioning of 1KVA inverter for emergency lighting in each floor with battery back up of 30 minutes. The unit shall consist of automatic changeover system. When the EB power failes immediately the inverter supply should come ON and cut out when the DG supply of EB supply comes ON. The bettary shall be kept changing all the time. MCB shall be provide on incomer and outgoing for protection.
SAFETY ITEMS
22mm thick HT Rubber Mat 600x1000mm size with ISI mark suitable for spreading in front of the Electrical Panel.
6mm thick HT Rubber Mat 600x1000mm size with ISI mark suitable for spreading in front of the Electrical Panel.
CO2 fire extinguisher 2 KG. rating with accessories.
Rescucition Chart
First Aid box (Standerd)
EARTHING
Earthing with copper plate 600mm x600mm x3mm thick i/caccessories and providing masonry enclosure with copper plate having locking arrangement and watering pipe etc(but without charcoal or coke& salt)
Extra for using salt & charcoal for G.I. or copper plate earth electrode as reqd.
P/F 25mm x5mm copper strip in 40mm dia. GI pipe from earth electrode as reqd.
Providing and fixing earth bus of 25mm x 5mm copper strip on surface or in recess for connection.
P/F 8 SWG dia. Copper wire on surface on in recessed for loop earthing along with existing recessed conduit wiring etc, as reqd.
P/F GI tape 32mm x6mm on surface or in recess for connection etc
EXTERNAL ELECTRICAL WORKS
Supply Installation testing and commissioning of 11KV ring units as per approvals of ESCOM. The unit shall consist of 3 panels set having 630Amp. VCBs with self powered tripping devices and with earth switch, all weather, self standing design using 14G CRCA sheet & ISMC bottom frame (ESCOM i/c PORTION to ESCOM requirement).
Supply Installation testing and commissioning of 11KV ring units as per approvals of ESCOM. The unit shall consist of HT metering cubicle and 3 panel set having 630Amp. VCBs with self powered tripping devices and EFOC relay all weather, self standing design using 14G CRCA sheet & ISMC bottom frame (SVHK control PORTION )
Supply and laying of 240 sq.mm 3 core, 11KV rated XLPE cables inHT section of the sub station for EB incomer to ESCOM RMU/Transformer.
Supply Installation commissioning of HT cable joining and termination of 240 sq.mm 3 core cable using heat shrinkable kit Raychem as per specification.
Supply Installation testing and commissioning of Outdoor type 11/0.415 KV, 1250 KVA, 3 phase, 50 Hz, vector group Dyn-11 ONAN cooled copper wound Transformer , ON load lap changer (OLTC/RTCC) to cater to voltage variation range of +5% to – 7.5% in 18/19 steps, first filling of oil, suitable cable termnation boxes on both sides ( suitable for 11KV, 3 corex240 sq.mm XLPE side for 5 nos 400 sq.mm 3.5 core cable) complete with standard fittings and accessories as per IS:2028/1977 upto date amendments, including buchholz relay oil temperature indicator, winding temperature indicator marshalling box etc and other standard accessories as per technical specifications including 1st fill of oil & 100 litres spare.
Supply Installation testing and commissioning of LT Kiosk on the secondary side of transformer consisting of 2000A 4 pole MDO ACB with self powred tripping facility, space and terminal extension suitable for 6+6 nos 400 sq.mm 3.5 core PVCA cable for cable termination, 14/16 G CRCA sheet steel fabricated outdoor type all weather proof panel.
STREET LIGHTING
Supplying with fitting & fixing of 1x18W CFL/400mm tall integral type with lamps, luminaire consisting of single piece integral epoxy grey powder coated housing with gasket. Decorative transluscent toughned glass enclosure. Similar to C&G make SONARA post top decorative luminaire CPFT-18/x8 W CFL.
Supply, Installation, Testing & commissioning of Solar light having the following.
i. Output equivalent to 30W CFL with 4260 Im.
ii. Emitting lamp: 9 W high power LED lamp.
iii. Lumens : 1260 LM
iv. SMF Battery : 12V40 Ah (Make Exide)
v. Solar photovoitaic module : 12V,45Wp
vi. Monocrystline solar module.
vii. Working hours: 12 Hours @ Night time.
viii. Autonomy backup: 3 days back up in monsoon time period.
ix. Switching : Dust to dawn systems or option switch ON/OFF.
x. Pole height & size: 5 meters, 75mm OD, 3mm thickness.
xi. Accessories: Countroller, Mounting clamp, connectors etc.
xii. Coverage Area : 12x5 mtr.i.e 60 sq.mtr.
Supply, Installation, Testing & commissioning of 4x250W flood light on a suitable 9 mtr height pole outdoor mounting all weather proof, non integral type with 250W HPSV with control gear in a separate all weather proof enclosure. To be installed in Car parking area as per drawing and specification, painting complete.( At 4 location s covering outdoor area).
LIGHTENING CONDUCTOR
Early streamer electronic lightening protection system including lightening finial self chaging unit mounting MS frame work, RP copper cable, isolating switch at ground level earthing station complete for 50m radius protection ABB/Seimens/ Alltech.
Aviation obstruction neon red light fitting with pipe frame work and wiring from the lift panel room complete ready to use.
S/F 25 amp air conditioner power plug point i/c 4 modules metal box on surface or in recess 4 modules plate and cover in fornt, 25 amp modular starter 25amp modular socket outlet and 25amp plug i/c connection etc, as reqd.
S/F 1.5TON capacity split type air conditioner (Diamond, 3 star, 5G 29, G-SC 18 FD3 WJH) complete without voltage stabilizer.
S/F Indo voltage correcvtor automatic / stabilizer, 5 KVA (140-280 V) for air conditioner.
S/F 1TON capacity split type air conditioner (Diamond, 3 star, 5G 28, G-SC 12 FD3 WJH) complete without voltage stabilizer.
S/F Indo voltage correcvtor automatic / stabilizer, 3 KVA (140-280 V) for air conditioner
S/F 25 ltr water heater (Geyser) AC-2 KW vertical type with all accessories including connection etc
(B) SITC of HVAC
A. Equipment
Supply, installation in position,testing, commissioning of High Wall & Cassette (both indoor andOutdoor units) complete with filters, DX cooling coils connected to DX condensing units.
a) 17 TR Ductiable UNITS
b) 11 TR Ductiable UNITS
B. Piping
Supplying, installing, testing, commissioning of UPVC pipes complete with fittings and ‘U’ traps for CondensateDrain Piping with supports, and thermal insulation as per specifications. a) 32 mm dia.
Supplying, installing, testing, commissioning of copper pipes complete with fittings for Refrigerant Piping with supports, and thermal insulation as per specifications
C.GI DUCTING
a) 22G DUCTING
b) 24G DUCTING
c) 26G DUCTING
d) INSULATION
Supply & Installation of Volums control Dampers.
Supply & Installation of canvas connection for inddor units.
Supply & Installation of Fresh air dampers.with bird screen Cowl.
Supply & Installation of butterfly dampers 250 dia..
Supply & Installation of boxes.
Supply & Installation of supply Air Diffusers of size 595x595 to Suite false ceiling grid and neck size of 450x450.
Supply & Installation of supply Air Diffusers of size 595x595 to Suite false ceiling grid and neck size of 450x451.
Supply & Installation of Toilet grils 150x150.
Supply & Installation of Toilet Exhaust inline fans of 600 efm &25mm static.
D. ELECTRICAL WORK
CABLE,CABLE TRAY & TERMINATION
Supply, Laying of stranded copper Cable of following sizes.
a) 8 core x 1.5 sq. mm
b) 2 core x 2.5 sq. mm
c) Supply & Installation of MS stand for Outdoor units.
C) SITC of CCTV
Supply Installation testing commissioning of CCTV system.
a) Dome / Bullet camera 3.2 mm IR 1.3 MF x compatible with false ceiling mount and suitable for single cable (Power & Video transmission to DVR).
b) Multi core screened cables to match the above camera.
c) 32 Channel DVR with networking complete with power pack 32 in 1 video in 1 boardband LED screen complete ready to use with CC cameras.
d) Flat screen LCD monitor 42” size with all patch cables associated with DVR and extended second point monitoring.
D) SITC of Passive components of Data Net works, Telephone, Fire Alarm.
Supply Installation, testing commissioning of the following items including end termination.
a. Data socket RJ 45 in 1(DUO) or work stations with all accessories ready to fix.
b. Telephone socket RJ 11 with all accessories ready to fix.
c. CAT-6 data cable for work stations to switch (+ switch to server) including D marking and termination.
d. 2 Pair 0.5 sq.mm telephone cable for dedicated telephone points.
e. 19 mm conduit for telephone wiring from work stations to floor junction box.
f. 25 sq.mm copper flexible earthing cable connecting earth station and server and UPS (2 runs,40m + 40m).
g. 25mm conduit for net wiring from work station to main trough/ Tray.
h. PVC trough to be run in floor/ Ceiling for Cat-6 cable where ever required. The tough to be embedded in floor or run above false ceiling.
Smoke detectors dual type (Heat) addressable with adaptor complete ready to fix.
Twin core matched copper PVC insulated cable suitable for addressable system and connecting all the units and remote indicators including 20 mm PVC conduit with its accessories (FRLS).
Fire alarm panel 16-zone with addressable system UPS with battery, 2 nos. potential free contact for remote switching off power complete ready to use with above system.
Repeating hooter units for all floors linking main alarm panel.
60 KVA UPS units with latest technology components, pure sin wave out put overload short circuit protection with input 3 phase 390V to 450V/output 215V + 1% in each phase, battery backup for 30 Minute with by pass switch, combined working with 2 UPS. Necessary software complete ready to use.
500 intercom line with 6 – input EPABX Seimens / Alctel make working on PC base complete with desk, monitor necessary software / Hardware packages, data logging memory for 30 days all inclusive ready to use.
Krone make junction box with cover and metal enclosure for the following.
a. 500 line Master junction box .
b. 120 line floor junction box.
Sever package for EPABX integration including software
E) SITC of Autometic passenger lift
SITC of Autometic passenger lift , 8 person capacity.
F) SITC OF FIRE PROTECTION
(I) HYDRANT SYSTEM
Same as above for hard rock including blasting.
UNDERGROUND PIPING
Supply, Installation, Testing and Comissioning of Ductile Iron Spun Pressure Pipes (Class K9) with socket and spigot (Tyton) ends suitable for push-on-jointing shall conform to IS 8329/2000. All the pipes shall have ordinary Portland cement mortar lining on the inside and Zinc coating on the outside. The coatings shall conform to IS 8329/2000. Rate should include for laying in the trenches in true alignment and jointing including the cost of rubber gaskette. The Rate should include of all taxes.,
a) 80 mm dia
b) 150mm dia
Supply , delivery and installation of centrifugally cast (spun) Ductile Iron Fittings conforming to IS:9523/2004 having dimensions as given below. The rates mentioned here under are for fiitings, zinc coated externally with inside motar lining (with finishing as per class 13/IS 9523/2004) (Ex-works) Including transportation, taxes and duties etc.
a) 150 x 150 x 80 mm dia Tee
b) 150 mm dia 90 degree Bend
c) 150 x 150 x 150 mm Dia Tee
PIPING ABOVE GROUND
a) 50mm dia
b) 80mm dia
c) 100mm dia
d) 150mm dia
Supply, installation, testing and commissioning of approved make CI butterfly valves with vertical/horizontal gear unit with appropriate handle conforming to IS:13039 with necessary companion flanges, neoprene gaskets (16Kg/sq.cm. pressure rating), nuts and bolts including all the accessories to complete as per the specifications.
a) 50mm dia
b) 80mm dia
c) 100mm dia
d) 150mm dia
Supply, installation, testing and commissioning approved make air release valves with screwed ends confirming to IS 1703 -1977 with unions, etc.including all the necessary fixing materials complete. a) 20mm dia
Supply, installation, testing and commissioning of of scour valves with necessary connecting saddle/Tee include with complete fixing fixing materials as per specifications. a) 50mm dia
Construction of (750mm x 750mm and depth upto 900mm) valve chamber with 230mm thick mm best quality TM bricks in CM 1:4 over a bed of 150mm thick PCC 1:4:8 . Internal wall plastered smooth in CM 1:3 with water proofing compound and external walls plastered rough with sponge finish including curing, back filling of the chamber sides with the excavated soil, disposing of the surplus earth after back filling with initial lead of 30 meters. Providing medium duty cast iron frame and cover etc., complete. ( weight: 110kgs.) as per specification.
Supply, installation, testing and commissioning of Yard Hydrants comprising of the following: (a) 80mm dia pipe fitted with single headed 63mm dia landing valve as per design. (b) Providing 2nos 15mts long 63mm dia CP hose with gun metal male and female instantaneous coupling. (c) 63mm dia branch pipe with gun metal hexogonal detachable nozzle made of instantaneous coupling. (d) Two keys in recess type compartment for break glass. (e) 80 mm dia. GI bend. f) 80mm dia butterfly valve to be fixed in stand pipe (g) 80 mm dia. GIDF stand pipe (1 mtr. below ground + 1 mtr. above ground).
Supplying, installing and commissioning of fire brigade inlet connection conforming to IS 5290 comprising of 4nos. 63mm dia instantaneous couplings complete with CI non-return valve, CI butterfly valve, connected to 150 mm dia Fire hydrant ring main and fire hydrant wet riser pipes & U/G sump
Supplying, erecting & commissioning Fire Hose accessaries comprising of:
19mm dia. reinforced reel 30m length as per IS 5132 fitted with 6.35mm dia nozzle and shut off valve (IS 884 - 1969) . The hose reel shall be recessed swing type with reel drum.The hose shall be provided with coupling as per detailed specifications
Providing and fabricating MS supports in angle iron/plates pipes, channels, etc., as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The cost of galvanization of pipe supports as per specification shall be included in the scope of work.
Supply and fixing of grip bolts of size M12 x 100 mm long in column, ceiling, walls, etc., Rate includes for necessary drilling through column / flooring / ceiling etc., complete.
TOTAL FOR FIRE HYDRANT SYSTEM
FIRE EXTINGUISHERS - FIRST AID
Supply and install in position approved make Dry Chemical Powder Fire Extinguisher complete with chromium plated gun metal union (cap), fitted with braided hose and open nozzle with initial charge of Dry Chemical Powder and gas cartridge complete with bracket and fixing screws. The extinguisher is internally and externally coated with lead tin alloy through hot dip process and cylinder bearing No.IS:2171/1976 and the gas cartridge bearing with ISI certification mark.
a) Capacity - 10Kg.
b) Capacity - 2Kg.
Supply and install in position approved make Liquid Carbon-Di-Oxide type (Water type) Fire Extinguisher of 9 ltrs, capacity of conical shape fitted with chromium plated gun metal nozzle on the top end of the fire extinguisher for discharge of liquid and chromium plated gun metal union (cap) at the bottom with angle fixed in the centre, complete with bracket, fixing screws, spanner and one filling. The extinguisher is internally and externally coated with lead, tin alloy through electrolysis process and bearing IS:940/1976 with ISI certification mark.
Supply and install in position approved make carbon di-oxide fire extinguisher, made of high pressure steel with wheel type valve and one meter long braided high pressure discharge hose which should have a minimum of bursting pressure of 140 Kg/Sq.cm and fitted with ABS discharge born and handles (non-conductor), complete with bracket and steel handle on the body fully charged with ISI certification mark IS:2878/1976.
a) Capacity 2.0 Kg
Supply and install in position approved make AFFF Mechanical Foam Fire Extinguisher, 9 ltrs capacity fitted with chromium plated gun metal cap, plastic coated gas cartridge fitted with braided hose and foam branch complete with brackets and initial charge of Aqueous film forming liquid of 6% concentration as per IS:10204.
Supply and install in position approved make Fire Bucket of 24 Gauge, galvanized steel sheet, standard 9 ltrs, capacity and of round bottom shape, painted white inside black and outside red on the bottom dome with letters "FIRE" in black and gold with wall mounting bracket and screws.
TOTAL FOR FIRE EXTINGUISHERS - FIRST AID
PUMPS AND ACCESSORIES
Pump Driven by Electrical Motor
Supply, erection, testing & commissioning of electrical motor driven end suction back pull out centrifugal pump capable of delivering, 2600 LPM at a head of 56 mts. when running at 2900 rpm directly coupled to TEFC electrical motor of adequate HP to operate on 400/440 V 3 phase, 50 cycles AC supply with a terminal box suitable for reception, common bed plate with necessary anti vibration pads, necessary foundation bolts and accessories, necessary butterfly valves, 150 mm dia. Non return valve as per IS 778 with necessary flanges, neoprene gaskets (10.0 kg/sqcm), pressure guages, pressure switch, foot valve, Y-Strainer air vessel tank connections etc., complete in all respects. (Foundations required shall be done by the civil contractor). Note: 1 For Fire Hydrant & 1 For Sprinkler system.
Pump Driven By Diesel Engine
Supply, installation, testing & commissioning of diesel engine driven pump, horizontal mounted, centrifugal single stage pump, capable of delivering 2600 LPM at a head of 56 m when running at 1800 rpm with adequate BHP automatic diesel engine driven pumpset having the residential silencer system and other accessories like fuel tank, necessary cooling system, foot valve, Y-Strainer necessary butterfly valves, 150 mm dia. Non return valve as per IS 778 with necessary flanges, neoprene gaskets ( 10.0 kg/sqcm), day oil storage tank with piping, valves as per detailed specification and two separate starting mechanisms (automatic starting by battery power, electric starting motor as well as manual starting by electric start motor) with control panel comprising of pressure switch, electronic calibrated relay starter, repeater, relay push button switch for manual starting, common bed plate with anti vibration pads, necessary foundation bolts etc., complete in all respects as per the detailed specifdication. (Foundations required shall be done by the civil contractor).
Supply, installation, testing and commissioning electrically driven Jockey pump of capacity 300 LPM at 56M, head coupled to TEFC electric motor of adequate HP. The motor shall operating on 3Ph 50Hz, 400/440V AC supply with necessary Y-Strainer, 80mm dia non-return valves, 80mm dia gate valves, foundation bolts, PCC footing in 1:2:4 and providing suitable L & T make starter etc., complete. The set shall be fitted on common base frame, anti-vibration pads including foundation, bolts and nuts, Pressure gauge & Pressure switch with inter-connecting wiring etc., complete. etc.., complete as per standard design.
Supplying, fabricating, installing, testing and commissioning of M.S Air Cushion vessel tank of 250mm dia. & 1000 mm. length with necessary inlets, drain connections, 5 nos. automatic gun metal air release valve of 25mm dia. etc.,
TOTAL FOR PUMPS AND ACCESSORIES
FIRE PUMP PANELS AND ACCESSORIES
M.V. CABLES :
Supply and laying of aluminium/copper armoured cable as per specification on existing cable tray with two end terminations with necessary glanding, earthing, etc.
a) 3.0 core 120 sq mm aluminium conductor, armoured cable {PVC/SWA/PVC} (from MCC to 2 Nos. 75 HP motor) (25m)
b) 3.0 core 10 sq mm aluminium conductor, armoured cable {PVC/SWA/PVC} [from MCC to 15 HP motor]. (25mtr)
c) 12 core 2.5 sq mm copper cable for engine (20 Mtr.)
d) 2 core 2.5 sq mm copper cable for pressure switch (20Mtr.)
e) 4 core 2.5 sq mm copper cable for MCC to ESP interlocking. (15Mtr)
f) 2 core 2.5 sq mm copper cable for level indicator (75Mtr)
g) Cable tray supports using perforated type made of MS/GI of required width with bolts and nuts to fabricate the tray to required length. 100 (Kgs)
WIRING
Supply of 1100 V grade PVC insulated copper conductor wires drawn in 16 SWG in 25mm MS conduit with accessories etc as per specification
a) 3.5 core x 120 Sq mm (For Main Electric Pumps)_
b) 4 core x 16 Sq mm (For Jockey Pump)
c) 12 core x 2.5 Sq mm (For Diesel Engine Pump)
d) 2 core x 2.5 Sq mm (For Instrumentation)
ENGINE STARTER PANEL
Supply , erection ,testing & commissioning of wall mounted 24 v control panel to start the fire pump engine automatically as per the following sequence of operation & the auxiliary arrangements.
Engine to start automatically in case of low water pressure secured by the pressure switch with necessary timers , relays etc.
Manual stopping.
Audio visual alarm for :-
Low fuel oil level.
Engine over speed.
High water temperature.
Low lube oil
Engine fails to start
A battery charger with Trickle/Boost arrangements with secondary side tapings at 28, 30, 32 & 34 V equipped with silicon diodes to charge the starting battery of the diesel engine.
MOTOR CONTROL CENTRE (MCC):
Supply, erection, testing and commissioning of Automatic Motor Control Panel comprising generally of the following and fabricated as per specifications.
a) 630 Amps incoming TP MCCB
b) 630 Amps aluminium bus bar as per specification.
c) 63 Amps SFU outgoing feeder for jockey pump.
d) 2 Nos. 320 Amps, SFU outgoing feeder for two nos. main electric pumps.
h) Audio visual alarm system and necessary indicating lamps.
i) Minimum length of 500 mm cable required for cable termination.
TOTAL FOR FIRE PUMP PANELS AND ACCESSORIES
SPRINKLER SYSTEM
Supply, erection, testing, and commissioning of heavy class GI pipes conforming to IS 1239. Pipe specials such as bends, tees, reducers, etc. shall be socket welded fittings. The pipes shall be with welded joints. Rate quoted shall include for necessary pair of flanges gaskets, nuts, bolts, etc., for pipes being suspended from ceiling, beam bottom, clamped on to the walls, etc., complete as per specifications.
a) 25mm dia
b) 32mm dia
c) 40mm dia
d) 50mm dia
e) 65mm dia
f) 80mm dia
g) 100mm dia
h) 150mm dia
Providing, fixing of pipe supports from column/wall or suspenders from roof slab to suit various dia of pipes made out of GI / MS adjustable rods threaded for a sufficient length to adjust the height of support along with clamping arrangement for holding pipes of anchor fastening arrangement design of hanger and should confirm to specification as indicated NFPA 13.
a) 25 mm dia.
b) 32 mm dia.
c) 40 mm dia.
d) 50 mm dia.
e) 65 mm dia.
f) 80 mm dia.
g) 100mm dia
h) 150 mm dia.
Supply, fixing, testing and commissioning of slimseal CI butterfly valves as per detailed specifications complete with vertical/horizontal gear unit with handle, companion flanges, gaskets, nuts and bolts etc., complete confirming to IS: 13039.
a) 150mm dia
b) 100mm dia
c) 80mm dia
d) 65mm dia
e) 50 mm dia
Providing and fixing nominal bore quartzoid bulb type sprinkler 68 Deg.C pendent type sprinkler type including range pipe upto 65 mm dia heavy grade GI pipe confirming to IS 1239 with CI taper special conforming to BS 1641 suspending arrangement with ceiling / wall / beam, clamp clips etc., complete.
Supply of spare sprinklers as per the specifications mentioned in item no. 4.0 above
Supply and fixing pipe supports like channel, angle iron, flats as per drawings/specifications and to suit site condition, including for necessary G.I 'U' clamps, welding, cutting, nuts, washers, etc., rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports.
Supplying, installing, testing and commissioning of flow switch installed on the sprinkler main distribution line capable of sending impulses to the addressable fire alarm panel with necessary contacts of size 4C x 2.5 sq. mm PVC/SWA cabling with necessary monitor module.
Supply, fixing, testing and commissioning of Sprinkler Installation Control Valve consisting of - 1 no. Alarm valve, 1 no. Main stop valve, 1 no. water meter with alarm gong, Pressure guage drain valve and drain piping etc., as per specification. a) 150mm dia
Supply, erection, testing and commissioning of 2 loop micro processor controlled addressable Sprinkler annunciation panel located in pump house with audio visual signals, battery, battery charger, central processing unit, addressable input/output module for connecting cabling, transflow switch, video display unit, printer etc., complete as per detailed specification.
Supply, installation, testing and commissioning approved make air release valves with screwed ends confirming to IS 1703 -1977 with unions, etc.including all the necessary fixing materials complete.
a) 20mm dia
TOTAL FOR SPRINKLER SYSTEM
SIGNAGES
Providing and installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, complete with mirror fasteners.
Signage with printed "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.25cm height letters in red with white back ground.The size of the board shall be 25cm x 25 cm and shall be fixed at the height of 2 mts. from finished floor near Manual call points.
Floor indentification signage ( ie, GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 5 cm with contrasting colour from back ground.Size shall be 15cm x 30cm.
Signage with the following text "FIRE EXIT" at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground.Size shall be 15cm x 60cm.
Providing and fixing in position the signages " FIRE ORDER" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerised cut, PVC non-reflective self adhesive vinyle painted foam board of 2' x 3'.
ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS.
EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY AND ASSEMBLE AT VARIOUS ASSEMBLY POINTS.
IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER.
BE CALM AND DO NOT GIVE ANY ROOM FROM PANIC, WALK, DO NOT RUN.
IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM.
ACTION BY SECURITY/RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM.
ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM.
INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS: 101 / LOCAL FIRE OFFICE NUMBERS
REFER EVACUATION PLAN FROM EVACUATING STANDARD PEOPLE.
GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE.
IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER……..
FIRE FIGHTING AGENCY --------------------------
PHONE : -----------------------
TOTAL FOR SINAGES
FIRE DETECTION AND ALARM SYSTEM (ANALOGUE ADDRESSABLE TYPE)
Main Control Panel
a) 4 Loop Panel
Local Control Panel (Mimic panel)
a) Supply, fixing, testing and commissioning of Local control panel with RS 232 communication interface module and dual stage alarm facilities, complete with all alarms, hooterS, fire/fault indicators, audio/visual signals,conrol modules, rectifier with necessary supporting frame work, auxilliary contacts etc., as per detailed technical specifications.
Repeater Control Panel (RC)
To give audio visual alarms/indications for both fire and fault.
Heat Detectors (Addressable)
Heat detectors grade-1 with solid state design with sensing element with combination of fixed type and rate of rise of temperature, indicating lamp, mounting base etc., as per specification.
Multi sensor Detectors (Addressable)
Multi sensor detectors with dual chamber, solid state design, indicating lamp, mounting base etc., as per detailed specification.
Electronic Hooters
Dual tone electronic hooters as detailed in the technical specification with volume controller. Rate quoted shall include for providing MS box of suitable size for concealing the hooter in the wall.
Manual Call Points (MCP)
Manual call points/push button stations as detailed in the technical specifications with necessary control modules. Rate quoted shall include for providing MS box of suitable size for concealing the MCP in the wall.
Response Indicators
Response indicators with incandescent type and with necessary fixing arrangements.
Supply, fixing, testing and commissioning of Fault Isolator module as per the detailed specifications etc., complete.
Cables
Supplying, testing and commissioning of 1100V grade 1.5 sq.mm PVC armoured copper conductor FRLS control cables as per specification. (The rate quoted shall include necessary cable end terminations with copper lugs, cable glands, crimping identification tags at each end etc., complete)
2 core x 1.5 Sq.mm in 20 mm dia.
10 core x 2.5 Sq.mm
10 x 2.5 sq.mm core cable laid below ground with proper protection. Rate quoted shall include for necessary excavation upto 450 mm depth in all sorts of soil and backfilling.
Supply & fixing of control module which is capable of interfacing with the analogue addressable fire alarm control panel with the lift panel. The control module should be capable for grounding the lift incase of a fire alarm.
Yumkham Subhaschandra Meetei
Guigui Kamei
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
BOQ_1484.xls
BOQ • 0.57 MB
Tender_documents.pdf
Tender Documents • 1.18 MB
Drawing.pdf
Additional Documents • 9.85 MB
Download all tender documents and submit your bid