Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.7 LAccepted-AOC R O KHREW TEH PAMPORE DISTT PULWAMA PIN 191103 J K | PULWAMA | JAMMU AND KASHMIR | 191103 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹6.0 L+₹14,520 (2.48%)Rejected-Finance FIRDOUS ABAD BATMALOO SRINAGAR PIN 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | L-2 | Rejected-Finance Not being L-1. | |
| 3 | L-3₹6.9 L+₹1.0 L (17.9%)Rejected-Finance SANAT NAGAR SRINAGAR PIN 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | L-3 | Rejected-Finance Not being L-1. | |
| 4 | L-4₹7.4 L+₹1.6 L (27.2%)Rejected-Finance KRAL PORA BAGH I MEHTAB NEAR MANCHOWA PETROL PUMP DISTRICT BUDGAM 190019 J K | BUDGAM | BUDGAM | J K | 190019 | L-4 | Rejected-Finance Not being L-1. | |
| 5 | L-5₹7.5 L+₹1.6 L (28.2%)Rejected-Finance | L-5 | Rejected-Finance Not being L-1. |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
5 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 861 EWS
GE 861 EWS c/o 56 APO
REPAIR AND MAINT OF CENTERALISED AC SYSTEM AT KHUNDRU UNDER AGE EM INSTALLATIONS OF GE 861 EWS
2024_MES_640714_1
GE861 EWS-71/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 861 EWS
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹18,000
Yes
30 Mar 2024
5 Feb 2024
12 Mar 2024
5 Feb 2024
5 Mar 2024
20 Feb 2024
Amount
Comprehensive maintenance of Package type AC Plant of capacity 3 X 24TR comprising of following equipment mentioned below complete all as as specified and directed. (a) Scroll type Compressor -6 No (b) Compressor motor -06No (c) Fan motor -02 No (d) Air handling unit with blower motor -01No (e) Electrical control panel cubical type floor mounted complete with main switch, MCCBs, MCB's, voltmeter, Ammeter, auto matic star delta starter for compressors, AHU, pumps, etc. complete-01 Set. (f) Air supply duct with grill diffusers, dampers and heater back of each complete-01Set (g) MS piping, valves, pressure gauge, temperature gauge, complete-01Set. (h) Digit type thermometer-01Set (j) Oil tank, Expansion Tank, Glycol Tank (k) Chiller motor, Boiler motor, Oil tank motor
M&L for servicing by dismantling/ disconnecting taking out worn/defective parts each Job carefully after unscrewing nut, bolts, clean thoroughly and repair/replacement of defective parts to make fully serviceable of 03x Boiler of capacity 85000KCL testing complete all as specified and directed.
M&L for taking down unsv burnner form oil fired hot water generator and replacing it with new burner for boiler of capacity 85000K.cal, automatic monoblock burner assembly, complete all as as specified and directed.
M&L for refilling of Glycol of chillar plant with with anti freeze properties, of glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrel. Note: the glycol concentrate shall be mixed with potable water supplied by contractor and filled in central pipe line after proper leak test of entire circuit, the glycol water mixture ratio be 40:60 and freezing temperature should be (-) 25° C. or complete all as specified and directed.
M&L for taking out old/burnt winding from Glycol circulation pump 3 HP and cleaning with CTC solution and rewinding the electric moter with super enameled heavy duty copper winding wire existing gauge and existing Nos of turn with and including insulation material insulation paper, varnish and baking up till the complete insulating dried included transport charges etc, complete all as as specified and directed.
M&L for taking out old/burnt winding from oil circulation pump/Chiller fan upto 2 HP and cleaning with CTC solution and rewinding the electric moter with super enameled heavy duty copper winding wire existing gauge and existing Nos of turn with and including insulation material insulation paper, varnish and baking up till the complete insulating dried included transport charges etc, complete all as as specified and directed.
M&L for taking out old/burnt winding from compressor Motor 13.62 KW and cleaning with CTC solution and rewinding the electric moter with super enameled heavy duty copper winding wire existing gauge and existing Nos of turn with and including insulation material insulation paper, varnish and baking up till the complete insulating dried included transport charges etc, complete all as as specified and directed.
M&L for Over hauling of Monoblock pump set of capacity upto 3 HP after removing from the base plate, disconnecting from pipe line, dismantling the pump set, replacing unserviceable gland packing, gun metal bush bearing water seal applying grease, vaibration pad etc. complete and reassembling the pump set connecting with pipe line reconnection of electric supply, including nuts bolts, gaskets etc. complete testing of pumps for smooth functioning complete all as specified and directed
M&L for Refilling of refrigerant 402R in chillar including pressure testing for 72 Hrs complete nitrogen flushing, complete all as as specified and directed.
M&L for repair /replacement of chiller relay suitable for 24 TR Chiller unit present on site, complete all as as specified and directed.
M&L for checking and overhauling the compressor unit of chiller non functional items should be replaced by contractor, complete all as as specified and directed.
M&L for for disconnecting condenser for descaling, plugging them & providing of 15mm tee out let for local circulation of mild acid solution in the condenser (separate container and small pump set to circulate diluted acid solution to be used) PH value of solution to be circulated & to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be used for descaling purpose after 2 to 3 hours of cleaning if ph value remains less than flush with fresh water mixed with sodium carbonate tubes and cleaning after closing the end covers, circulating diluted acid solution as specified above, to maintain PH value as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure of capacity 3x 24 TR plant complete all as specified & directed by Engineer-in-Charge.
M&L for pumping down the chiller plant to preserve the existing in refrigerant gas & leak testing of plant by charging of nitrogen gas in to entire plant & monitoring for 24hrs to find the leakages, rectification of leak by brazing & replacement of necessary gasket packing where ever required including copper tubes of suitable size vacumising of the plant by vacum pump & keeping 24hrs for pressure testing including rectification of leakages if any finally recharging of existing refrigerant gas to the plant and topping up of refrigerant if required to maintain the standard pressure complete testing of the plant for smooth functioning complete all as as specified and directed.
M&L for complete servicing of the AHU unit of cooling/Hot coils and AHU filters by dismantling the filter section, damper section, blower section complete cleaning and removal of the dust particles and cleaning the chocked fins, by using the appropriate chemicals, flushing till removel of the complete chocking across the cooling/hot coils, make free for air flow across the coil, to improve the efficiency of the cooling/hot coils including necessary rust proofing to the bottom base tray, coil tray, renewal of rusted bolts and nuts, refixing back the dismantled parts complete all as as specified and directed.
M&L for removing the existing fully chocked/unserviceable micro filter of AHU and supply and fixing new mirco filter with HDPE 400 media 10 micro rating filters to AHU's outer size 610(H)x610(Wx50mm(D) including renewal of nuts,bolts and washer complete all as as specified and directed.
M&L for taking out burnt winding from 10 HP motor of AHU and cleaning with CTC solution and rewinding the electric motor with super enameled heavy duty winding wire of existing gauge and existing Nos of turn with and including insulation material insulation paper, varnish and baking up till the complete insulating dried, included transport charges etc, complete all as as specified and directed.
M&L for taking down the damaged V-Belts of size B-42 and supply & fix V-Belts with suitable slack adjustment and alignment complete all as specified and directed.
M&L for dismantling and removing of old unserviceable control wiring and renewaling of control wiring with inter lock system using suitable copper wiring of existing size with from panel board to compressor, pump and blower motor, starter heater humidistat anti freez thermostat etc including control switches cut out of suitable make complete including lugs necessary indication bulbs, holder fuse carriers and termination and testing of control wiring with inter lock system to the entire satisfaction of Engineer-in-Charge. NOTE : Size of cable wire should with stand the current rating of pumps/motors etc
M&L for repair/replacement of mild steel fuel gas chimeny made out of 3mm thick mild steel sheet, 6 mtr long 150mm dia of the plant room including connection to independent boiler, inside bldg fiber glass insulation wool of 24kg/cum with alluminium cladding complete all as specified and directed.
M&L for lagging for the 20mm GI tubing in external water supply of plumbing all around with 25mm thick bonded mineral wool pre-formed. SNAPON pipe section of density 144 Kg/Cum conforming to IS-9842 or equivalent and provided chicken wire mesh netting 25gauge 20mm meshing and plaster of Peris 3 to 5 mm thick all around the mesh after breaking old unsv/ broken lagging complete all as specified and directed.
M&L for lagging to pipes used in external water supply of plumbing all around with 25mm thick bonded mineral wool pre-formed. SNAPON pipe section of density 144 Kg/Cum conforming to IS-9842 or equivalent and provided chicken wire mesh netting 25gauge 20mm meshing and plaster of Peris 3 to 5 mm thick all around the mesh after breaking old unsv/ broken lagging all as specefied and directed by Engineer in charge .
M&L for lagging to pipes used in external water supply of plumbing all around with 25mm thick bonded mineral wool pre-formed. SNAPON pipe section of density 144 Kg/Cum conforming to IS-9842 or equivalent and provided chicken wire mesh netting 25gauge 20mm meshing and plaster of Peris 3 to 5 mm thick all around the mesh after breaking old unsv/ broken lagging complete all as specified and directed.
S&F in replacement of old damaged / unserviceable ball valves of size 25mm dia,screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed connection pipes complete all as specified and directed.
S&F in replacement of old damaged / unserviceable ball valves of size 15mm dia,screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed connection pipes complete all as specified and directed.
S&F in replacement of old damaged / unserviceable butter fly valves of size 65mm dia,made out of cast iron complete all as as specified and directed.
S&F in replacement of old damaged / unserviceable butter fly valves of size 50mm dia,made out of cast iron complete all as specified and directed.
S&F in replacement of Y strainer ofsize 50mm with fittings nt bolts gasket & all fixing arrangement complete all as specified and directed.
M&L for taking down old unserviceable insulation from any surface and supply and fix nitrile rubber insulation of one layer of 19mm thickness closed cell nitrile elastomeric insulation of density not less than 24 kg/m3 and sealing the joints by weather proof tape complete all as specified and directed.
Supply and Fixing in replacement of the dial type Pressure Gauges of 100mm dia withcocks and syphon complete withcomplete all as specified and directed.
Supply and Fixing in replacement of Temperature Gauges of size 50/65 mm dia complete with all fittings etc complete all as specified and directed.
Supply and Fixing in replacement of automatic air purfier valves of nominal size 25mm complete all as specified and directed.
S&F in replacement of three way motorised mixing valve with actuator, temperature sensor & controller etc complete all as as specified and directed.
S&F Duly insulated with 25mm thick closed cell elastomeric insulation 30 to 40 Kg/m3density for Hot/ Chilled fluid pipes & Glycol Expansion tank all as specified and directed
S&F in replacement of Digital level indicator for Glycol flud tank etc complete all as specified and directed.
S&F in replacement of Digital level indicator for Day oil storage tank etc complete all as specified and directed.
S&F in replacement Vibration pads for pumps etc complete all as specified and directed.
S&F in replacement of Locking arrangement and PVC transparant pipe of reqired lenth with suitable fixing arrangement etc for Glycol Expansion Tank etc complete all as specified and directed.
Supply and fix in replacement power contactors, MNX25 three phase, 415V complete all as specified and directed.
Supply and fix in replacement Auxliary contactors 1NO+1NC three phase, 415V complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to galvanised iron strip 25×4mm means of bolts, nuts check nut & washers of galvanised iron or steel & connected to main switch including complete excavation and earth work in soft/loose soil and disposal of surplus soil to a distance not exc 50 meters, PCC Chamber (1:3:6) type C-2 precast RCC cover with frame, funnel wire mesh, 20mm bore light grade galvanised iron or steel pipe for water, charcoal or coke and salt in alternative layers of 15cm compacted thickness all round the earth electrode complete alll as shown in electrical plate No 3 of SSR part-I including welding with suitble electrode and testing complete all as directed. NOTE :- (i) Main earthing strip from earth plate electrodeto test point upto length of 7.5 mtrs length shall deem to be included in the unit rate quoted against this item. (ii) M&L Tubing GI med grade 40mm dia for protection of earthing strip and passing the Road/passes and etc.shall deem to be included in the unit rate quoted against this item. (iii) On testing after completion if the desired resistenance is not obtained the contrator shall redo the earthing without any extra cost to the department .
Supply and layning in replacement of old damaged/ rusted MS black ERW pipe class 'C' of size 32 mm heavy for HSD line inclding cost of bends, reducer, flanges, nuts, bolts etc complete all as specified and directed. Note : Welding is deemed to be included in this rate.
Supply and layning in replacement of old damaged/ rusted MS black ERW pipe class 'C' of size 25 mm heavy for HSD line inclding cost of bends, reducer, flanges, nuts, bolts etc complete all as specified and directed. Note : Welding is deemed to be included in this rate.
Supply and layning in replacement of old damaged/ rusted MS black ERW pipe class 'C' of size 65 mm piping complete with fitting dly nslated with 25mm thick nitrile insulation duly insulated thickness mentioned there in with closed cell elastomeric inslation 30 to 40 kg/m3 density covered with shirnk polyethlene sheet etc complete all as specified and directed. Note : Welding is deemed to be included in this rate.
Supply and layning in replacement of old damaged/ rusted MS black ERW pipe class 'C' of size 50 mm piping complete with fitting dly nslated with 25mm thick nitrile insulation duly insulated thickness mentioned there in with closed cell elastomeric inslation 30 to 40 kg/m3 density covered with shirnk polyethlene sheet etc complete all as specified and directed. Note : Welding is deemed to be included in this rate.
Supply & fixing in replacement of grill diffusers made of size 250mm dia large format adustable jet diffuser with plate made ot of aluminium, powder coated with all monting arrangements complete all as specified and directed
S&F testing and commissioning in replacement of damper actuator/smoke senser of motorised spring return Actuator for device pto 0.8 sq mtr with control panel smoke senser & temperture senser complete all as specified and directed
Supply, installation, testing, & commisioning in replacement of Humidifier of capacity 5ltrs/Hrs ultra sonic electric Atomizing humidifier emits fine emits fine mist into duct with isolation brass gate valve complete all as specified and directed Note : The system shall comprise as required and for automatic operation as per specification.
VEDA INFRASTRUCTURE
M/S BHAT ENGINEERING WORKS
M/S RATHER CONSTRUCTION CO
M/S LATIF AHMED MIR
M/s GHULAM NABI HAJAM
Top Mind Industries Pvt Limited
Asian Marketing Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .