Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.1 L+₹2.8 L (22.7%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
6 Jul 2020, 6:00 pmClosed
GE(U) E/M Meerut Cantt
GE(U) E/M Meerut Cantt
TENDER FOR ITEM RATE CONTRACT FOR REPAIR AND MAINTENANCE OF VT/ SUBMERSIBLE PUMP AND MOTORS, PANELS AND CONNECTED WORK AT VARIOUS WATER SUPPLY INSTALLATION UNDER AGE E/M (WS) AT GE(U) E/M MEERUT CANTT.
2020_MES_336393_2
8246
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Meerut Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(U) E/M Meerut Cantt
₹30,000
Yes
21 Sept 2020
20 Jun 2020
13 Jul 2020
20 Jun 2020
6 Jul 2020
20 Jun 2020
Amount
Supplying, laying or fixing, jointing and testing LT PVC insulated and PVC sheathed single core cable , ISI-1554 marked , with copper conductor , heavy duty 1100 Volts grade of 16 sqmm ,complete including taking down of existing unserviceable cable all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT PVC insulated and PVC sheathed single core cable , ISI-1554 marked , with copper conductor , heavy duty 1100 Volts grade of 25 sqmm ,complete including taking down of existing unserviceable cable all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT PVC insulated and PVC sheathed single core cable , ISI-1554 marked , with copper conductor , heavy duty 1100 Volts grade of 35 sqmm ,complete including taking down of existing unserviceable cable all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT under ground electric power cable aid in trenches/ fixed to walls/ laid in floors Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 50 sqmm 3 1/2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT under ground electric power cable aid in trenches/ fixed to walls/ laid in floors Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 70 sqmm 3 1/2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT under ground electric power cable, laid in trenches/ fixed to walls/ laid in floors Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 95 sqmm 3 1/2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
S&F ( in repairs) MCCB, 4 pole, 160 Amps, Icu=35KA, 415 volts, 50 hz, AC , with fixed thermal and magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed. Note: MCB/MCCB/and DBs shall be of same make .
S&F (in repairs) MCCB, 4 pole, 200 Amps, Icu=35KA, 415 volts, 50 hz, AC , with fixed thermal magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed. Note: MCB/MCCB/and DBs shall be of same make .
S&F (in repairs) MCCB, 4 pole, 100 Amps, Icu=25KA, 415 volts, 50 hz, AC , with fixed thermal magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed. Note: MCB/MCCB/and DBs shall be of same make .
S&F ( repairs) Aluminium thimble suitable for LT Aluminium cable of size 70 to120 Sqmm, 3.5 core complete all as spercified and directed.
S&F ( repairs) Copper thimble suitable for LT Aluminium cable of size upto 35 Sqmm, 3.5 core complete all as spercified and directed.
Supplying, fixing and testing ( in repairs) Main switch 4 POLES , 200 Amp side handle with MS sheet enclosure complete all as specified.
Supplying, fixing and testing ( in repairs) 100 Amps, 415V, 4 pole off load changeover switch with sheet metal enclosure, side handle operated , 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing complete all as specified and directed.
Supplying, fixing and testing ( in repairs) 200 Amps, 415V, 4 pole off load changeover switch with sheet metal enclosure, side handle operated , 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing complete all as specified and directed.
Supplying, fixing and testing ( in repairs) 315/320 Amps, 415V, 4 pole off load changeover switch with sheet metal enclosure, side handle operated , 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing complete all as specified and directed.
Dismantiling electric motor carefully from borehole after disconnecting the electric connections from panel board manually or mechanically and transporting both way to work shop and back, installation, refixing, reconnecting at site where directed after necessary repairs carried out and testing complete as directed by Engr-in-Charge for Electric motor 20 to 22.5 HP, 3 phase, 400/ 415 volts, 50 c/s of any make / type. Note:- Repairs and Parts Renewed shall be measured and paid for separately.Quoted rates deemed to include transportation charges including loading and unloading and labour charges for dismantling and refixing complete.
Dismantiling electric motor carefully from borehole after disconnecting the electric connections from panel board manually or mechanically and transporting both way to work shop and back, installation, refixing, reconnecting at site where directed after necessary repairs carried out and testing complete as directed by Engr-in-Charge for Electric motor 50 to 60 HP, 3 phase, 400/ 415 volts, 50 c/s of any make / type. Note:- Repairs and Parts Renewed shall be measured and paid for separately.Quoted rates deemed to include transportation charges including loading and unloading and labour charges for dismantling and refixing complete.
Dismantiling electric motor carefully from boreholel after disconnecting the electric connections from panel board manually or mechanically and transporting both way to work shop and back, installation, refixing, reconnecting at site where directed after necessary repairs carried out and testing complete as directed by Engr-in-Charge for Electric motor 75 HP, 3 phase, 400/ 415 volts, 50 c/s of any make / type. Note:- Repairs and Parts Renewed shall be measured and paid for separately.Quoted rates deemed to include transportation charges including loading and unloading and labour charges for dismantling and refixing complete.
Assessing the repairs to be carried out to the motors after dismantling and carrying out the neccessary repairs to motors by opening the electric motor carefully removing all burnt/wornout coils cleaning the slots and rewinding with super enamelled copper wire of existing size including varnishing two coats, drying and reassembling the electric motor at site and testing the smooth running of the motor on full load for 08 hours continuously for Electric motor of capacity 75 HP 3 phase, 400/ 415 volts, 50 c/s of any size /shape and make. Note: Payment of bearing shall be measured and paid separatly under relevant items .
Assessing the repairs to be carried out to the motors after dismantling and carrying out the neccessary repairs to motors by opening the electric motor carefully removing all burnt/wornout coils cleaning the slots and rewinding with super enamelled copper wire of existing size including varnishing two coats, drying and reassembling the electric motor at site and testing the smooth running of the motor on full load for 08 hours continuously for Electric motor of capacity 50 to 60 HP 3 phase, 400/ 415 volts, 50 c/s of any size /shape and make. Note: Payment of bearing shall be measured and paid separatly under relevant items .
Assessing the repairs to be carried out to the motors after dismantling and carrying out the neccessary repairs to motors by opening the electric motor carefully removing all burnt/wornout coils cleaning the slots and rewinding with super enamelled copper wire of existing size including varnishing two coats, drying and reassembling the electric motor at site and testing the smooth running of the motor on full load for 08 hours continuously for Electric motor of capacity 20 to 22.5 HP 3 phase, 400/ 415 volts, 50 c/s of any size /shape and make. Note: Payment of bearing shall be measured and paid separatly under relevant items .
Lifting of electric motor 22.5 HP to 75 HP capacity from existing position after disconnection of all electrical connection for renewal of U/S bearing and applying grease after removal of old grease and re-installing at site where directed after refilling new grease and reconnecting all electrical connection and testing complete. Note : (a) Necessary payment for bearing shall be measured and paid separately under relevant items if required at site. (b) Quoted rate deemed to include cost of grease as required at site. (c) The contractor shall lift the motors as directed by the dept for normal servicing even no repairs are reqd for the motor.
Renewal of Thrust bearing No. 7220 including dismantling/taking out unserviceable thrust bearing of any make, complete all as specified and directed.
Renewal of Thrust bearing No. 7316 including dismantling/taking out unserviceable thrust bearing of any make, complete all as specified and directed.
Renewal of Thrust bearing No. 29324 including dismantling/taking out unserviceable thrust bearing of any make, complete all as specified and directed.
Renewal of Ball bearing No. 6312 including dismantling/taking out unserviceable thrust bearing of any make, complete all as specified and directed.
Renewal of Ball bearing No. 6316 including dismantling/taking out unserviceable thrust bearing of any make, complete all as specified and directed.
Renewal of Ball bearing No. 6311 including dismantling/taking out unserviceable thrust bearing of any make, complete all as specified and directed.
Renewal of Ball bearing No. 6313 including dismantling/taking out unserviceable thrust bearing of any make, complete all as specified and directed.
Renewal of Ball bearing No. 6309 including dismantling/taking out unserviceable thrust bearing of any make, complete all as specified and directed.
M & L for bearing sheet of motor of capacity up to 75 HP motor including lathe work, brazing etc complete all as specified and directed.
Lifting of vertical turbine pump from existing position any make, type and capacity along with vertical hollow shaft motor, column pipe, top shaft, lineshaft etc and other accessories, after disconnecting electric and water connections complete and stacking aside for repairs complete all as directed by Engr-in-Charge. Item rate deemed to include the cost of trasportation from site to wksp and back , labour and any other tools reqd at site etc. Note:-Parts renewed shall be measured and paid for separately under respective item of Schedule 'A'. BoQ.
Dismantling carefully turbine pump set bowl assembly of any make, capacity upto 50000 GPH and size complete with out damaging any parts of the pump and setting aside in pump house for ascertaining the serviceability of existing parts with the following :- (a) Through dismantling and cleaning of complete bowl assembly items such as CI bowls, impeller, lock collets, bowl bush, suction and discharge case with GM bush including pump shaft. (b) Cleaning of all rotary and stationary parts of pump bowl assembly and making them for their satisfactory run. (c) Re-assembling the complete bowl assembly pump with all existing serviceable parts and renew the worn out unserviceable parts including S & F gasket ,lathe work and balancing of assembly others small nature of indispensable items as required for repairing. Note :- Parts renewed shall be measured and paid for separately under respective item of Schedule 'A'/BoQ at supplied only rates. Cost of labour for fixing of new parts shall be deemed to include in the rate quoted by tenderer.
Supply only CI centrifugally cast bowl assembly complete with gun metal bush ( make as per original manufacturer) for pump of capacity up to 50000 GPH of vertical turbine pump .
Supply only GM impeller ( make as per original manufacturer) for vertical turbine pump of capacity up to 50000 GPH of any type.
Supply only Stainless steel non magnetic pump shaft 25 to 32 mm ( make as per original manufacturer) dia suitable for 6 to 9 stage pumps (Bowl assembly) as directed .
Supply only M.S. line shaft (bright) steel 25 to 32 mm dia 10 Ft long with MS coupling and non magnetic stainless steel sleeve ( make as per original manufacturer) all as specified and directed.
Supply only Shaft coupling / sleeve of high carbon steel for 25 mm to 32 mm dia lineshaft ( make as per original manufacturer) all aspecified and directed.
Supply only GM Bush for suction case of VT pump ( make as per original manufacturer) all aspecified and directed.
Supply only GM Bush for discharge case of VT pump ( make as per original manufacturer) all aspecified and directed.
Supply only CI guide spider heavy duty with rubber bush and check nut suitable for 25 to 32 mm dia lineshaft of 150 mm bore pipe ( make as per original manufacturer) all aspecified and directed.
Supply only CI guide spider heavy duty with rubber bush and check nut suitable for 25 to 32 mm dia lineshaft of 200 mm bore pipe ( make as per original manufacturer) all aspecified and directed.
Supply only Rubber packing for discharge head upto 200 mm bore complete all as specified ( make as per original manufacturer) all aspecified and directed.
Supply only Rubber bush for guide spider for 25 to 32 mm dia lineshaft ( make as per original manufacturer) all aspecified and directed.
Supply only Stainless Steel top shaft not exceeding 32 mm dia and 3 mtr long, duly threaded both ends and made suitable slot for fixing the stainless steel key adjusting nut & lock washer ( make as per original manufacturer) all aspecified and directed.
Supply only CI Centrifugally cast suction case with GM Bush (make as per original manufacturer) all aspecified and directed.
Supply only CI Centrifugally cast discharge case with GM Bush ( make as per original manufacturer) all aspecified and directed.
Supply only Mild steel cold drawn ERW column pipe 3.00 M long, wall thickness not less than 7.2 mm thick, 150 mm bore, both ends flanged with Mild steel column coupling 12 mm thick including welding, flanged joint on both ends complete all as specified and directed by Engr-in-Charge
Supply only Mild steel cold drawn ERW column pipe 3.00 M long, wall thickness not less than 7.2 mm thick, 200 mm bore, both ends flanged with Mild steel column coupling 12 mm thick including welding, flanged joint on both ends complete all as specified and directed by Engr-in-Charge
Supply only Ratchet assembly complete with ratchet plate, ratchet balls hexagonal bolts etc suitable for up to 75 HP electric motor and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Supply only Ratchet plate suitable upto 75 HP VT motor and vertical turbine pump ( make as per original manufacturer) all aspecified and directed..
Supply only GM neck ring suitable for 100mm/150mm/200m dia VT pump and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Supply only PVC rubber Gasket 3 mm thick suitable upto 200 mm bore flanged joints .
Supply only Rubber bowl bush suitable for VT pump set and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Supply only Intermediate bowl bush GM suitable for VT pump set and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Supply only GM Impeller lock collect suitable for VT pump set and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Supply only CI fitting box (Gland box) of suitable type & shape for VT Pump and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Supply only Mild steel bowl bolts of suitable type, shape and size as required as per site of vertical turbine pump and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Supply only Mild steel full threaded bolts of suitable size having hexagonal head with one 3 mm thick washer and nut suitable for jointing 100/150/200 mm bore flanged joints complete all as specified.
Supply only Gun Metal split gland of any size & shape with G I clamp suitable for gland box of VT pump and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Lowering of turbine pump set any type and capacity upto 50000 GPH re-assembling of all accessories and column pipe after cleaning manually including fixing of motor in existing position making all Electrical & water supply connections and adjustment of pump load etc and testing of pump and motor after installation all as directed by Engr-in-Charge.
Cutting, facing of existing mild steel cold drawn ERW column pipe upto 200 mm dia to desired length and re-threading up to 80 mm run to suit existing coupling complete all as directed. Note :- Rate quoted by tenderer shall be deemed to include all transportation charges from site to work shop and back incl loading/unloading.
Cutting, facing of existing mild steel lineshaft up to 32 mm dia to desired length and re-threading up to 80 mm run as directed. Note :- Rate quoted by tenderer shall be deemed to include all transportation charges from site to work shop and back incl loading/unloading.
Cutting existing MS/BS/SS top shaft of size upto 32 mm dia making slot for key and rethreading both ends for required length to suit the coupling and load adjusting shaft nut all as directed by EIC.
Taking out rusted after disorienting old worn pump M S foundation bolt from cement concrete foundation base and fixing by providing new mild steel full threaded bolt of 20 mm dia not exc.300 mm long with proper cement concrete foundation (1:2:4) type B-1 using 20mm graded crushed stone aggregate and makeing the surface smooth to match with existing surface complete all as directed.
Repairing the base of discharge head of VT pump up to 50000GPH by Welding and renewing high carbon steel nut for the base of discharge head, including renewal of mild steel channel complete all as directed.
Renewal of Heavy duty terminal plate made of bakelite suitable for electric motor of capacity 30/40/50/75 HP with brass nuts of suitable size best quality as approved by GE complete all as specified and directed.
Renewal of Terminal plate cover made of CI for fixing over the terminal plate with cover for 30/40/50/ HP electric motor best quality as approved by GE complete all as specified and directed.
Labour for lifting of submersible pump along with flanged column pipe, submersible cable, safety rope etc from the existing bore well by using suitable T&P etc after disconnecting submersible cable from starter making necessary repairs by opening and renewal of parts as required including transportation to market and back for repair complete all as specified & directed for 10HP to 25 HP capacity pumpset. Note: Parts Renewed shall be measured and paid separately
Labour for lifting of submersible pump along with flanged column pipe, submersible cable, safety rope etc from the existing bore well by using suitable T&P etc after disconnecting submersible cable from starter making necessary repairs by opening and renewal of parts as required including transportation complete all as specified & directed for 2HP to 7.5 HP capacity pumpset. Note: Parts Renewed shall be measured and paid separately at supplied only rates under appropriate item(s).
Supply only Gunmetal impellers suitable for 10 to 25 HP Submersible pump
Supply only Gunmetal bush suitable for 10 to 25 HP Submersible pump
Supply only stainless steel sleeve suitable for 10 to 25 HP Submersible pump
Supply only 'C' type bushes for impellers suitable for 10 to 25 HP Submersible pump
Supply only Bowel case suitable for 10 to 25 HP Submersible pump
Supply only stainless steel shaft of standard size complete in all respect suitable for 10 to 25 HP Submersible pump
Supply only Gunmetal impellers suitable for 2 to 7.5 HP Submersible pump
Supply only Gunmetal bush suitable for 2 to 7.5 HP Submersible pump
Supply only stain less steel sleeve suitable for 2 to 7.5 HP Submersible pump
Supply only 'C' type bushes for impellers suitable for 2 to 7.5 HP Submersible pump
Supply only Bowel case suitable for 2 to 7.5 HP Submersible pump
Supply only stainless steel shaft of standard size complete in all respect suitable for 2 to 7.5 HP Submersible pump
Lowering down of submersible pump set along with connected items such as column pipes ,submersible cable by using suitable T&P and reconnecting all electrical connections,commissioning & testing complete all as specified & directed for 10 HP to 25 HP capacity pumpset.
Lowering down of submersible pump set along with connected items such as column pipes ,submersible cable by using suitable T&P and reconnecting all electrical connections,commissioning & testing complete all as specified & directed for 2 HP to 7.5 HP capacity pumpset.
Rewinding of submersible motor electric driven , AC supply with PVC insulated copper wire (ISI marked) as per existing gauge ,including connected works for rewinding .The scope of works includes dismantaling ,removal of old winding wire ,cleaning of slots & rewinding ,reassembling,testing complete all as specified & as directed for 10 HP to 25 HP capacity of pump motors. Note: Other parts required for repair will be measued and paid for separately under respective sch item.
Supply only Gunmetal bush for submersible motor suitable for 10 to 25 HP
Supply only Thurst bearing for submersible motor suitable for 10 to 25 HP
Rewinding of submersible motor electric driven , AC supply with PVC insulated copper wire (ISI marked) as per existing gauge ,including connected works for rewinding .The scope of works includes dismantaling ,removal of old wiring wire ,cleaning of slots & rewinding ,reassembling,testing complete all as specified & as directed for 02 HP to 7.5 HP capacity of pump motors. Note: Other parts required for repair will be measued and paid for separately under respective sch item.
Supply only Gunmetal bush for submersible motor suitable for 2 to 7.5 HP
Supply only Thurst bearing for submersible motor suitable for 2 to 7.5 HP
S & F (in repair) Submersible cable flat ,water proof,PVC insulated,PVC sheathed,3 core,10 sqmm,1100 volts grade ,multistranded copper conductor including making water proof cable joint with submersible motor and normal connections through lugs/thimbles into starter panel complete all as specified and directed.
S & F (in repair) Submersible cable flat ,water proof,PVC insulated,PVC sheathed,3 core,6 sqmm,1100 volts grade ,multistranded copper conductor including making water proof cable joint with submersible motor and normal connections through lugs/thimbles into starter panel complete all as specified and directed.
Disconnecting & taking out/opening of the non-functional 3 phase servo voltage stabilizer of any description in any position for taking out unserviceable / defective wiring & parts, cleaning and servicing complete including renewal of unserviceable parts complete, draining-out of transformer oil for repair work renewal of unserviceable wiring with new copper wire cable of existing size, reassembling ,connecting and testing complete all as specified and directed by Engineer-in-Charge for 3 phase 75 KVA capacity . Notes :- (i) Parts renewed shall be measured and paid for separately under appropriate item of Sch ‘A’ at supply only rates but fixing of the parts replaced/repaired/Renewed is deemed to be included in this item. (ii)Transformer oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly all as directed by the Engineer-in-Charge. (iii) Tenderer Quoted rate shall be deemed to include for all transporting charges including loading/unloading to workshop and back where required complete all as specified.
Disconnecting & taking out/opening of the non-functional 3 phase servo voltage stabilizer of any description in any position for taking out unserviceable / defective wiring & parts, cleaning and servicing complete including renewal of unserviceable parts complete, draining-out of transformer oil for repair work renewal of unserviceable wiring with new copper wire cable of existing size, reassembling ,connecting and testing complete all as specified and directed by Engineer-in-Charge for three phase 50 KVA capacity . Notes :- (i) Parts renewed shall be measured and paid for separately under appropriate item of Sch ‘A’ at supply only rates but fixing of the parts replaced/repaired/Renewed is deemed to be included in this item. (ii)Transformer oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly all as directed by the Engineer-in-Charge. (iii) Tenderer Quoted rate shall be deemed to include for all transporting charges including loading/unloading to workshop and back where required complete all as specified.
Disconnecting & taking out/opening of the non-functional 3 phase servo voltage stabilizer of any description in any position for taking out unserviceable / defective wiring & parts, cleaning and servicing complete including renewal of unserviceable parts complete, draining-out of transformer oil for repair work renewal of unserviceable wiring with new copper wire cable of existing size, reassembling ,connecting and testing complete all as specified and directed by Engineer-in-Charge for three phase 31.5 KVA capacity . Notes :- (i) Parts renewed shall be measured and paid for separately under appropriate item of Sch ‘A’ at supply only rates but fixing of the parts replaced/repaired/Renewed is deemed to be included in this item. (ii)Transformer oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly all as directed by the Engineer-in-Charge. (iii) Tenderer Quoted rate shall be deemed to include for all transporting charges including loading/unloading to workshop and back where required complete all as specified.
Supply only Micro toggle switches all as specified.
Supply only Auto manual switches . all as specified.
Supply only high and low voltage indicator light complete all as specified.
Supply only panel indicator light for main "ON' indication all as specified.
Supply only push button all as specified.
Supply only potential meter all as specified.
Supply only Electronic sensing card (Printed circuit Board all as specified.
Supply only 12 pin connector all as specified.
Supply only rotary mechanism of dimmer through armature motor for capacities of stabilizers 03 phase up to 75 KVA all as specified.
Supply only Servo motor 10 kg torque all as specified.
Supply only RC network for servo motor 10 KG all as specified.
Supply only Trigger Transformer 440 V to 220 V all as specified.
M&L for rewinding of Buck booster transformer with super enamel copper wire including paper insulation packing, varnishing etc including taking out old burnt winding complete all as specified and directed, for three phase 75 KVA capacity of stabilizers all as specified.
M&L for rewinding of Buck booster transformer with super enamel copper wire including paper insulation packing, varnishing etc including taking out old burnt winding complete all as specified and directed, for three phase 50 KVA capacity of stabilizers all as specified.
M&L for rewinding of Buck booster transformer with super enamel copper wire including paper insulation packing, varnishing etc including taking out old burnt winding complete all as specified and directed, for three phase 31.5 KVA capacity of stabilizers all as specified.
M&L for rewinding of Dimmer with super enamel copper wire including paper insulation packing, varnishing etc including taking out old burnt winding complete all as specified and directed, for 30 KVA to 50 KVA capacity of stabilizers all as specified.
M&L for rewinding of Dimmer with super enamel copper wire including paper insulation packing, varnishing etc including taking out old burnt winding complete all as specified and directed, for 75 KVA capacity of stabilizers all as specified.
Renewal of Insulators, vitreous, suitable for voltage stabilizers up to 160 Amps current rating, complete all as specified.
M&L new transformer oil in servo voltge stabilizer to fulfil upto required level. Note: break down value of transformer oil should not be less than dielectric strength 50 KV .all as specified.
M&L for dehydration / filteration of transformer oil in servo voltage stabilizer breakdown value of transformer oil should not less than dielectric strength 50 KV . Note : Contractor will arrange filtration plant machine at site of voltage stabilizer transformer oil dehydration work will be carried out in working condition all as specified.
M&L for preparation of old painted surface of steel / iron of servo voltage stablizer of any capacity by scaping with emery/sand paper,brushing, cleaning, staining grease/oily spots with thinner and applying two coats of superior quality synthetic enamel paint with spray machine over a coat of primer complete all as specified and directed.
Supply & fix Single/reverse phase preventor for motor protection with by pass arrangements to run the motor in case of emergency with low/high voltage cut off and time delay/relay of 1 to 3 sec.including dismantling/taking out of unserviceable phase preventor of any make and type complete all as specified and directed.
Repair to oil immersed Star delta starter any type /make capacity 22.5 HP to 75 HP including renewal of U/S parts and wiring as required to made the starter serviceable condition. Note : Spare parts shall be measured and paid separatly at supply only rates.
Supply only Contact set comprising of 03 Nos moving contacts & 06 Nos. fixed contacts suitable for Oil mimersed star- delta starter upto 75 HPcomplete all as specified and directed.
Supply only Thermal Over load relay of range 65 to 110 Amps (for 3 phase,415 V motor of 75 HP) complete all as specified.
Supply Thermal Over load relay of range 45 to 75 Amps (for 3 phase,415 V motor of 50 HP) complete all as specified.
Supply Thermal Over load relay of range 28 to 36 Amps (for 3 phase,415 V motor of 22.5 HP) complete all as specified.
Supply Power contactor 3 pole above 50 HP upto 75 HP with 415 V/220 V , AC Coil complete all as specified.
Supply Power contactor 3 pole upto 50 HP with 415 V/220V , AC Coil complete all as specified.
Supply Power contactor 3 pole upto 25 HP with 415 V/220V , AC Coil complete all as specified.
Supply only Electronic Timer ET 100, 110/240 Volts, 50 Hz, range 9-30 seconds complete all as specified.
Supply only Thermal timer type GT 200, operating voltage 230/250 Volts, 400/440 Volts, 50 Hz fun 5-18 seconds range complete all as specified.
Supply only Pnematic timer block (star delta) complete all as specified.
S & F in repairs HRC fuse with base 125 Amps,415 Volts,50 Hz ,80 KA all as specified.
S & F in repairs Push button actuators with carrier & contact element of type Flush spring return with 1NO/1NC/2NO block (red/Green colour) all as specified.
S & F in repairs Phase indiactors ,240 V i.e pilot lamp indicators with series Resistor & diode with filament bulb all as specified.
S & F in repairs Digital Amp meter 96 mm square flush mounted type 0-200 Amp,3 phase all as specified.
S & F in repairs Digital volt meter 96 mm square flush mounted type 0-500 volts, 3 phase all as specified.
S & F in repairs tape wounded CT 200/5 Ratio all as specified.
Repair to phase sequence changer of any type /make capacity 22.5 HP to 75 HP including renewal of U/S parts and wiring as required to made the sequencer serviceable condition.
M&L for transporting of unserviceable pump of any capacity bothways from site to repair workshop including dismantling all parts required to carryout repair work and reassembling the same after completion of repair work including testing submersible pump for proper functioning all as specified and directed. for 10 HP to 25 HP pump complete all as specified and directed. Note: Parts renewed shall be measured and paid separately under appropriate items herebefore.
M/S JPS Electrical Engineer & Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .