Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-AOC 427 KACHARI KARCHHANA PRAYAGRAJ UP 212307 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 212307 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹6.0 L+₹39,850 (7.17%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹6.8 L+₹1.3 L (23.1%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹7.7 L+₹2.2 L (39.2%)Rejected-Finance D 2 36 VIBHUTI KHAND GOMATI NAGAR LUCKNOW UTTAR PRADESH 226010 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226010 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹8.6 L+₹3.1 L (55.4%)Rejected-Finance 161 SADAR BAZAR SADAR BAZAR CANTT AYODHYA UP PIN 224001 | AYODHYA | AYODHYA | UP | 224001 | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | His And Her Enterprises L3 | niranjan singh and company L2 | H.P. ENGINEERING L1 | Jairajyadav security services L5 | Lucknow Refrigeration L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fixing in repair LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including suitable bracket and fixing arrangement complete all as specified and as directed. | 20 | Each | 1,600 ₹32,000 | 1,400 ₹28,000 | 1,300 ₹26,000 | 1,220 ₹24,400 Lowest | 3,500 ₹70,000 |
| 2.00 | S & F LED in repair light bulkhead fitting 1x9W/10W IP66 & IK09 integral LED Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including taking down old unserviceable fitting complete all as specified and as directed. | 20 | Each | 350 ₹7,000 Lowest | 500 ₹10,000 | 400 ₹8,000 | 950 ₹19,000 | 998 ₹19,960 |
| 3.00 | S&F in repair/replacement TPN DB suitable for MCB TPN incomer, double door (IP-54), 4 Ways, built- in 200 Amps busbar for neutral link complete suitable for 415 Volts, AC, 50 Hz complete all as specified and as directed. | 3 | Each | 3,600 ₹10,800 | 2,500 ₹7,500 | 2,800 ₹8,400 | 1,600 ₹4,800 Lowest | 4,100 ₹12,300 |
| 4.00 | S&F in repair/replacement TPN DB with suitable for TPN MCB incomer, double door (IP-54), 8 Ways, built- in 200 Amps busbar for neutral link complete suitable for 415 Volts, AC, 50 Hz complete all as specified and as directed. | 3 | Each | 5,500 ₹16,500 | 3,800 ₹11,400 | 3,200 ₹9,600 | 2,200 ₹6,600 Lowest | 5,990 ₹17,970 |
| 5.00 | Supply and fixing repair/replacement sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated SPN 8 way 240 Volts AC complete all as specified and as directed. | 8 | Each | 1,850 ₹14,800 | 1,300 ₹10,400 Lowest | 1,600 ₹12,800 | 1,300 ₹10,400 Lowest | 2,021 ₹16,168 |
| 6.00 | Supply and fixing repair/replacement sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated SPN 12 way 240 Volts AC complete all as specified and as directed. | 8 | Each | 2,250 ₹18,000 | 1,500 ₹12,000 Lowest | 1,700 ₹13,600 | 1,600 ₹12,800 | 2,430 ₹19,440 |
| 7.00 | M&L in repair in repair/replacment submain wiring including taking down with two single core PVC insulated FRLS-H multistrand copper conductor cable of size 04 Sq mm drawn through existing conduit not less than 20 mm size ISI marked with all fittings / accessories and one 2.5 Sq mm FRLS-H multistrand copper conductor cable as continuous earth wire connected to earth dolly including colour coding of copper conductor ie for Phase-Red/Yellow/Blue, Neutral-Black and Earth wire-Green colour complete all as specified and as directed by Engr-in-Charge.
Note :- (i) Two run of single core cable and one run of earth wire will be measured as one length
(ii) All copper conductor shall be connected to MCBs/Switches etc with copper lugs/Thimble | 60 | RM | 200 ₹12,000 | 120 ₹7,200 | 205 ₹12,300 | 100 ₹6,000 Lowest | 350 ₹21,000 |
| 8.00 | All as above ser item No 7 but with PVC casing n caping complete all as specified and as directed by Engr-in-Charge. | 60 | RM | 200 ₹12,000 | 130 ₹7,800 Lowest | 210 ₹12,600 | 160 ₹9,600 | 325 ₹19,500 |
| 9.00 | M&L in repair for point wiring concelaed with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through rigid non metallic conduit not less than 20mm size, medium grade with all necessary fittings, concealed wiring , for one light/fan/socket/bell point controlled by one switch including 1.5 Sq mm PVC insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes/ on PVC rectangular block with 3 mm thick plastic laminated sheet cover of suitable size for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover ,for housing switches, socket outlet, regulator etc. and colour coding of copper conductor ie for Phase-Red/Yellow/Blue, Neutral-Black and Earth wire-Green colour complete all as specified and directed by Engr-in-Charge. | 30 | Point | 400 ₹12,000 Lowest | 400 ₹12,000 Lowest | 450 ₹13,500 | 480 ₹14,400 | 450 ₹13,500 |
| 10.00 | All as above ser item No 9 but with PVC casing n caping complete all as specified and as directed by Engr-in-Charge. | 30 | Point | 400 ₹12,000 Lowest | 400 ₹12,000 Lowest | 450 ₹13,500 | 420 ₹12,600 | 425 ₹12,750 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
22 Nov 2025, 6:00 pmClosed
AGE (I) Ayodhya Cantt
Asst Garrison Engineer (I), Military Engineer Services, Ayodhya Cantt PIN-224001
REPAIR/MAINT/REPLACEMENT OF OLD/UNSV VTPN DB/MCB BUILDING SECURITY LIGHT, SERVICE CONNECTION AND CERTAIN MISCELLANEOUS WORK AT MARATHA LI OTM AND MD ACCN UNDER AGE (I) AYODHYA
2025_MES_738110_1
8400/140/E8
Open Tender
Civil Works
Item Rate
180 days
Ayodhya Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Ayodhya
₹20,000
Yes
11 Mar 2026
1 Nov 2025
24 Nov 2025
1 Nov 2025
22 Nov 2025
15 Nov 2025
Amount
Supply and fixing in repair LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including suitable bracket and fixing arrangement complete all as specified and as directed.
S & F LED in repair light bulkhead fitting 1x9W/10W IP66 & IK09 integral LED Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including taking down old unserviceable fitting complete all as specified and as directed.
S&F in repair/replacement TPN DB suitable for MCB TPN incomer, double door (IP-54), 4 Ways, built- in 200 Amps busbar for neutral link complete suitable for 415 Volts, AC, 50 Hz complete all as specified and as directed.
S&F in repair/replacement TPN DB with suitable for TPN MCB incomer, double door (IP-54), 8 Ways, built- in 200 Amps busbar for neutral link complete suitable for 415 Volts, AC, 50 Hz complete all as specified and as directed.
Supply and fixing repair/replacement sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated SPN 8 way 240 Volts AC complete all as specified and as directed.
Supply and fixing repair/replacement sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated SPN 12 way 240 Volts AC complete all as specified and as directed.
M&L in repair in repair/replacment submain wiring including taking down with two single core PVC insulated FRLS-H multistrand copper conductor cable of size 04 Sq mm drawn through existing conduit not less than 20 mm size ISI marked with all fittings / accessories and one 2.5 Sq mm FRLS-H multistrand copper conductor cable as continuous earth wire connected to earth dolly including colour coding of copper conductor ie for Phase-Red/Yellow/Blue, Neutral-Black and Earth wire-Green colour complete all as specified and as directed by Engr-in-Charge. Note :- (i) Two run of single core cable and one run of earth wire will be measured as one length (ii) All copper conductor shall be connected to MCBs/Switches etc with copper lugs/Thimble
All as above ser item No 7 but with PVC casing n caping complete all as specified and as directed by Engr-in-Charge.
M&L in repair for point wiring concelaed with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through rigid non metallic conduit not less than 20mm size, medium grade with all necessary fittings, concealed wiring , for one light/fan/socket/bell point controlled by one switch including 1.5 Sq mm PVC insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes/ on PVC rectangular block with 3 mm thick plastic laminated sheet cover of suitable size for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover ,for housing switches, socket outlet, regulator etc. and colour coding of copper conductor ie for Phase-Red/Yellow/Blue, Neutral-Black and Earth wire-Green colour complete all as specified and directed by Engr-in-Charge.
All as above ser item No 9 but with PVC casing n caping complete all as specified and as directed by Engr-in-Charge.
All as above ser item No 9 but with existing conduit complete all as specified and as directed by Engr-in-Charge.
All as per item No 9 here-in-above but for one light point controlled by two nos of 2 way switches complete all as specified and as directed by Engr-in-Charge.
All as per item No 9 here-in-before but One 3 pin socket outlet 5/6 Amps on the same board with other switchs with cables 1.5 Sqmm size complete all as specified and directed by Engineer-in-Charge.
All as per item No 9 here – in – before but for one 3 / 5 -pin switch socket outlet 5/6 amps on independent board complete all as specified and directed by Engineer-in-Charge..
All as per item No 9 here – in – before but for one switch socket outlet 15/16 Amps on independent board with 2.5 Sqmm multi stranded and 2.5 Sq mm stranded for earth wire PVC insulated un-sheathed copper cable.
Supply and fix in repair switch piano flush button, single pole, 5/6amps, one way all as specified and as directed by Engr-in-Charge
Supply and fix in repair/replacement switch piano flush button, single pole, 5/6amps, two way complete all as specified and as directed by Engr-in-Charge
Supply and fix in repair socket outlet 3 pin 5A flush type complete all as specified and as directed by Engr-in-Charge
Supply and fix in repair switch piano flush button, single pole, 15A, one way all as specified and as directed.
Supply and fix switch in repair socket combination 2 – in – one, 6A flush type compete all as specified and as directed.
Supply and fixing repair switch socket combination 2 – in – one 16A flush type universal complete all as specified and as directed.
Supply & Fixing repairs ceiling rose surface bakelite 65 X 50 mm three terminal all as specified and as directed.
Supply & fixing Bell repairs push flush type, 5 Amps button all as specified and as directed by Engr-in-Charge
Supply & Fixing Bell, repairs AC 230 Volts single pole including mounting block all as specified and as directed Engr-in-Charge
Supply and fixing in repair LED lights batten fitting 4 Feet 18/20W, 220V, AC batten type with driver, holder including LED tube rod connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing in repair LED lights batten fitting 2 ft 9/10W, 220V, AC batten type with driver, holder including LED tube rod connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing in repair/replacement round shape 18 watt 220 volts AC recessed mounting type CCT- 3000 K/ 6500 K with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete including taking down old unserviceable fitting complete all as specified.
Supply and fixing in repair LED luminaire square shape 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete including taking down old unserviceable fitting complete all as specified and as directed.
S&F in repair/replacement TPN DB suitable for MCB TPN incomer, double door (IP-54), 4 Ways, built- in 200 Amps busbar for neutral link complete suitable for 415 Volts, AC, 50 Hz complete all as specified and as directed.
S&F in repair/replacement TPN DB with suitable for TPN MCB incomer, double door (IP-54), 8 Ways, built- in 200 Amps busbar for neutral link complete suitable for 415 Volts, AC, 50 Hz complete all as specified and as directed.
Supply and fixing repair/replacement sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated SPN 8 way 240 Volts AC complete all as specified and as directed.
Supply and fixing repair/replacement sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated SPN 12 way 240 Volts AC complete all as specified and as directed.
Supply and fixing in repair 415V 10KA 'C' curve miniature circuit breaker MCB of TPN 63-100 AMP in the DB complete with connection testing and commissioning all as specified and directed by Engr-in-Charge.
Supply and fixing in repair amp rating 240V, 10KA 'C' curve miniature circuit breaker MCB of SPN 32-40 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
Supply and fixing in repair amp rating 240V, 10KA 'C' curve miniature circuit breaker MCB of SPN 63 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
Supply and fixing amp in repair rating 240V, 10KA 'C' curve miniature circuit breaker MCB SP 10A to 25A and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
Supply and fixing in repair stepped socket type electronic fan regulator type on the existing phenolic laminated sheet etc as complete all as specified and as directed by Engr-in-Charge
Supply only PVC insulation tape is ideal for low voltage applications such as insulation, sealing, joiniting, fixing and to facilititate colour-coding for safety and identification purpose complete all as specified and as directed.
Supply only white 1.5mm x 2 core twin flat copper wire with triple layer PVC Insulation for electrical connection of light fittings and fixtures including fixing arrangements on laid on walls with clips and clamps complete all as specified and as directed.
Supply only PVC 25/20mm cable nail clips for fixing of conduit laid on walls with necessary fixing arrangement without disturbing existing surface complete all as specified and as directed.
Supply and Fixing exhaust fan, PVC body AC single Phase. 230V of size 200mm sweep with, blades, and frame and louvers including fixing arrangement complete all as specified and directed by Engr-in-Charge.
Supply and Fixing exhaust fan, steel body AC single Phase. 230V of size 450mm sweep heavy duty with, blades, and frame and louvers including fixing arrangement complete all as specified and directed by Engr-in-Charge.
Supply and Fixing exhaust fan, MS steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers including fixing arrangement complete all as specified and directed by Engr-in-Charge.
Supply only non-metallic PVC casing n caping of size 20/25mm connected with boxes junction/ terminal but inclusive of all tees, bends, elbows, reducers, fixing accessories such as couplers, lock nuts, saddles, complete all as specified and and directed.
Supply & fixing in repair single phase two wire single phase digital electrionics energy meters ISI marked in existing meter board / florr panels having current range 10-60 Amp 240 Volt accuracy class 1.0 Make:- Secure/HPL/L&T/Anchor
Supply & fixing in repair single phase two wire three phase digital electrionics energy meters ISI marked in existing meter board / florr panels having current range 10-60 Amp 240 Volt accuracy class 1.0 Make:- Secure/HPL/L&T/Anchor
Supply only DWC flexible conduit pipe 50mm dia black/grey in color complete all as specified and as directed.
Supply only PVC 50mm cable clips for fixing of DWC flexible conduit pipe laid on walls with necessary fixing arrangement without disturbing existing surface complete all as specified and as directed.
Supply and fixing in repair PVC 8 module modular electrical gang box, white/grey in color, standard quality for mounting switches and sockets complete all as specified and as directed.
Supply and fixing in repair PVC 6 module modular electrical gang box, white/grey in color, standard quality for mounting switches and sockets complete all as specified and as directed.
Supply and fixing in repair PVC 4 module modular electrical gang box, white/grey in color, standard quality for mounting switches and sockets complete all as specified and as directed.
Supply and fixing in repair PVC 3 module modular electrical gang box, white/grey in color, standard quality for mounting switches and sockets complete all as specified and as directed.
Supply and fixing in repair PVC 1/2 module modular electrical gang box, white/grey in color, standard quality for mounting switches and sockets complete all as specified and as directed.
Supply and fixing in repair PVC 3 inch dia 5 mm thickness PVC round sheet electrical complete all as specified and as directed.
Supply only LED bulb 9 watt cool white 240V AC 50 Hz complete all as specified and as directed.
Supply only LED bulb 12 watt cool white 240V AC 50 Hz complete all as specified and as directed.
Taking down carefully electric water heater (Geyser) of any make and any capacity from its mounting place opening for inspection compete including back plate, heating element, inner copper tank etc, de-scaling back plate and heating element by cleaning with Sulfuric acid/ de-scaling compound and re-assembling of Geysers after repairs carrying out and re-fixing in same position including making good to disturbed portin of walls with CM (1:3) or PCC (1:2:4 Type B1) and plastering the wall surfaces with CM 1:6 and replacement of old nuts, bolts and rubber gasket etc, complete all as specified and as directed. Note (1) Any type of rubber gasket , rubber washer, screws , insulating tape required shall be deemed to be included in the quoted rate. Note (2) The descaling / cleaning the inner tank including denting and brazing the leakage joints / points till the leakage stops including carrying out minor repair of outer body surface, bottom and top cover complete all as specified and as directed. Note (3) The cleaning of all type dust, stains and painting of geysers with one coat of syntatic enamemel paint by spraying and refixing properly in the same location complete all as specified and directed.
S&F in repair/replacement 2.0 KW capacity Heating Element, Push/ Screw type with round mechanism and facilitate to fixing/holding of thermostate 'O' Ring type' including making electrical connection complete all as specified and as directed by Engineer-in-Charge.
S&F in repair/replacement 1.5 KW capacity Heating Element, Push/ Screw type round mechanism and facilitate to fixing/holding of thermostate with 'O' Ring type' including making electrical connection complete all as specified and as directed by Engineer-in-Charge.
S&F in repair/ replacement for Thermostat/autocut switches for geysers 25/ 50 Ltr capacities including making connection complete all as directed by Engineer-in-Charge.
Taking down defective ceiling fan 1200/1400 mm sweep, checking of faults and refixing the same in original position after gressing and repairing of faults including replacement of unsv components. (Note : Items required for repairing will be measured and paid separately as supply only)
Supply only bearing 6201/6202 suitable for ceiling fan 1200/1400 mm sweep complete all as specified and as directed
M&L for MS fan hanger clamp with suitable bolts, nuts, washers, split pin and rubber reel complete all as specified and as directed
Supply only condenser 2.5 Mfd suitable for ceiling fan 1200/1400 mm sweep with clip complete all as specified and as directed
Rewinding of burnt ceiling fan of 1200/1400 mm sweep with super enamelled copper winding wire as per existing weight complete all as specified
Material and labour for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core, including glands, lugs, nut, bolts, washers as required at site, testing complete all as specified and directed. Note:- (i) XLPE cable shall be laying into the DWC pipe (ii) XLPE DWC pipe shall be measured and paid separately
Supplying and fixing in repair 1100 volts grade heavy duty cable 10 sqmm PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire with two single core cables complete all as specified and as directed.
M&L labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1 : 3 : 6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 5 of MES SSR Part-I and as directed.
niranjan singh and company (BID ID -3479556)
His And Her Enterprises (BID ID -3475741)
Lucknow Refrigeration (BID ID -3479848)
Jairajyadav security services (BID ID -3480424)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
TENDERDOCS.pdf
Tender Documents • 0.70 MB
BOQ_826493.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .