Loading…
Loading…
Tender Value
₹3.7 Cr
EMD Value
₹3.3 L
Closing Date
19 Feb 2026, 5:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
+ Capital Works)
Above/Below/Par
GENL
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less, where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited (for details correction slip no. 01 vide L. No. 2022/CE-I/CT/GCC 2022/Policy dt. 4.07.2022 to be referred.) The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.(For details pl. refer GCC April 2022 with amendment, if any)
The Bid Security shall be deposited either in cash through e-payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure VIA and shall be valid for a period of 90days beyond the bid validity period(For other details GCC april 2022 para 5 of part -I to be referred with amendment,if any)
(a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.(For details pl. refer GCC April 2022 with amendment ,if any)
Similar Nature of works means-Electrification / Rewiring of Service or Residential building / Yard / HT / LT substation work / HT/ LT cable work / street lighting / platform or building lighting management / circulating area Lighting / Electrical overhead power supply work / Electrical pump work etc.
15 conditions · 8 needing a document upload
FOR DOCUMENT TO BE SUBMITTED BY THE TENDERER FOR TENDER ALONG WITH THE OFFER. OFFERS WITHOUT THESE DOCUMENTS WILL BE SUMMARILY REJECTED as detailed given in checklist of tender booklet attached in document.
Documents as per the requirement of financial eligibility criteria: The tenderers shall submit requisite information as per 'Annexure-VIB' indicating Annual Contractual turnover data for the previous 3/4 years, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant / Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Tenderer should submit copy of PAN Card along with their tender.
The Tenderer shall submit copy of Goods and Services tax (GST) Registration Certificate containing GST Registration Number.
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. In case the tenderer is other than Joint Venture (JV) firm, tenderer has to submit all the documents mentioned below, as the case may be: (a) Sole Proprietorship firm : An undertaking on suitable stamp paper to this effect clearly mentioning PAN number. (b) HUF : (i)A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (c) Partnership Firm :(i) A notarised copy of partnership Deed or Copy of Partnership deed registered with the Registrar. (ii) A notarized or registered copy Power of Attorney in favour of the individual to tender for the work, sign the agreement etc. and create liability against the firm. (iii) An undertaking by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry / department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LPP in which they were/are partners/ members. Any Concealment /wrong information in regard to above shall make the ineligible or the contract shall be determined under clause 62 of the standard general conditions of contract.(e) Company registered under Companies Act-2013 : (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation(iii)A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (f) LLP (Limited Liability Partnership ) registered under LLP Act 2008: (i)A copy of LLP Agreement (ii)A copy of Certificate of Incorporation (iii)A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv)An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (g) Registered Society & Registered Trust:(i)A copy of Certificate of Registration (ii)A copy of Memorandum of Association of Society/Trust Deed (iii)A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against Society /Trust.(iv) A copy of Rules & Regulations of the Society.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Augmentation and improvement of Electrical Substations and other load centers over Nagpur division.
NGP--L-2026-T-02
NGP--L-2026-T-02
Open
Works - General
15 Months
Nagpur, Maharashtra
₹0
₹3.3 L
19 Feb 2026
29 Jan 2026
89 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,69,35,547.42 | ||
| — | 100.00 | — | — | ||
| Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 120 sq. mm. aluminium conductor laid in provided trench / pipe. (JNO-100) | — | — | — | 1,82,192 | |
| — | 1200.00 | — | — | ||
| Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 185 sq. mm. aluminium conductor laid in provided trench / pipe. (NGP-1200) | — | — | — | 28,43,328 | |
| — | 700.00 | — | — | ||
| Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 240 sq. mm. aluminium conductor laid in provided trench / pipe. (AQ-500 & BPQ-200) | — | — | — | 19,72,600 | |
| — | 16.00 | — | — | ||
| Supply, erection, testing and commissioning of 11 kV HT outdoor heat shrinkable end terminating Kit suitable for 3 core 95/120/185 Sq.mm Aluminum armoured XLPE cable. (NGP-8 & JNO-8) | — | — | — | 2,08,343.2 | |
| — | 100.00 | — | — | ||
| Providing and erecting Heat shrinkable out door termination kit for 11 kV (E) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification. (AQ-82, BPQ-10) | — | — | — | 16,46,866 | |
| — | 4.00 | — | — | ||
| Supply, erection, testing and commissioninig of Heat Shrinkable Type Straight through Jointing Kit suitable for 3 core 95/120/185 Sq.mm Aluminium armoured XLPE cable. (NGP-4) | — | — | — | 56,238.8 | |
| — | 1200.00 | — | — | ||
| SETC of LT XLPE insulated, armoured, PVC sheathed Allu. Conductor cables size of 4 Core 300 Sq. mm. with aluminium lugs, glands suitable nut bolt etc (AQ-500, BPQ-300 & WR-400) | — | — | — | 14,10,168 | |
| — | 1500.00 | — | — | ||
| SETC of LT XLPE insulated, armoured, PVC sheathed Allu. Conductor cables size of 4 Core 400 Sq. mm. with aluminium lugs, glands suitable nut bolt etc (NGP-1000 & AQ-500) | — | — | — | 20,52,930 | |
| — | 30.00 | — | — | ||
| Providing & erecting heat shrinkable straight through UG cable joint size- 4 core 185- 400 sq.mm. (AQ-10, NGP-10, WR-10) | — | — | — | 92,714.4 | |
| — | 3000.00 | — | — | ||
| Provision of trench in all kind of normal Soil to depth 40x100cm & filling the trench (After laying cable) to bring the original condition. | — | — | — | 2,35,740 | |
| — | 1000.00 | — | — | ||
| Provision of trench in hard rock/soil/road track crossing to depth 40x100cm & filling the trench (After laying to bring the original condition. | — | — | — | 1,71,330 | |
| — | 4000.00 | — | — | ||
| Supply and laying of DWC pipe of in the cable trenches/under track /along the poles/DP structures to be provided including all connected Accessories under other sch itemsDWC pipe of dia 160 mm. | — | — | — | 15,29,880 | |
| — | 300.00 | — | — | ||
| Excavation of thrust pit of size (3 M X4.5 M X 2.5M) 2 nos in hard Murom at both and refilling of pit after laying of cables etc. (AQ-300) | — | — | — | 80,661 | |
| — | 300.00 | — | — | ||
| Horizontal boring of size 10 inch dia 250 mm in Railway embankment for connection to both end. (AQ-300) | — | — | — | 7,25,952 | |
| — | 400.00 | — | — | ||
| Providing and pushing of HDPE pipe confirming to relevant ISI of 8 inch dia and having 4 KGS pressure in horizontally made bore by push method including laying cable inside HDPE pipe. (AQ-300) | — | — | — | 3,22,644 | |
| — | 314.00 | — | — | ||
| Provision of maintenance free earthing as per RDSO specification no. RDSO/PE/ SPEC/ PS/0109- 008(REV'0') complete. | — | — | — | 41,70,277.96 | |
| — | 1200.00 | — | — | ||
| Supply and erection of GI Flat of size 25x3 mm from earth pit with GI nut Bolt suitable size. (If required additional for maintenance free earthing) | — | — | — | 76,596 | |
| — | 16.00 | — | — | ||
| Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. And handing over to section office inclusive of transportation up to 25 km, between site and section office. | — | — | — | 14,971.36 | |
| — | 14.00 | — | — | ||
| Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150mm. thick M- 10 PCC at the bottom and top and 250 mm.thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate.External surface duly plastered by 12 mm thick including watering etc complete. (AQ-10, BPQ-2 & JNO-2) | — | — | — | 2,35,577.86 | |
| — | 1.00 | — | — | ||
| SETC of outdoor, Plinth Mounted, Oil Immersed, oil cooled, copper wound Non-Sealed type (Transformer tank body and cover are bolted) Distribution Transformer, 250 KVA Rating, 11KV/415V, 3-phase, 50 Hz, Primary Winding in Delta and Secondary Winding in Star (Vector symbol- Dyn11), LV cable box, ONAN Cooled Transformer as per IS 1180 (Part 1): 2014/latest with amendment nos. 1,2,3 & 4. Off-load Tap changer for variation of HV Voltage from +5% to -10% in steps of 2.5%, with all standard fittings as per Clause 20.1 of IS 1180 (part 1) and Oil temperature indicator & winding temperature indicators, Drain-cum- sampling valve (3/4 inch nominal size thread, IS:554) of Steel with plug, Energy Efficiency level- 2 or above, conforming to IS 1180 (Part 1): 2014/latest with amendment nos. 1,2,3 & 4 complete. (JNO-1) | — | — | — | 6,01,800 | |
| — | 6.00 | — | — | ||
| SETC of HT 11 KV 800A VCB panel complete to consist of 1 Nos. of Incomer + 2 Nos. of Outgoing Panel. A) 11kV 800A Incomer Panel - 1 Nos. BREAKER: 11kV, 800A, 26.3kA, 30V DC TC CC, 230V AC. CT 200-100/5- 5A. PT Ratio 11KV/v3/110V/v3 volts and All electronic multifunction meter B) 11kV 800A Outgoing panel - 2 Nos. BREAKER: 11kV, 800A, 26.3kA, 30V DC 230V AC. CT 100-50/5-5A. and All electronic multifunction meter. The offered relays shall be multifunction numerical type compatible with RS485/IEC 618050 Modbus protocol required for SCADA communication complete with foundation etc. AQ-5 & JNO-1) | — | — | — | 1,09,22,722.8 | |
| — | 3.00 | — | — | ||
| SETC of LT outdoor Distribution Panel in 16 SWG CRCA Sheet Powder Coated having capacity 1250 Amps aluminium busbar consisting with FP ACB 2x1000 Amp as incoming with 1000 Amp Bus coupler and FP MCCB 2x630 A, 4x400 A, 2x250 A & 2x100A as outgoing along with protection, measuring instrument and other accessories complete with fixing arrangement. (AQ-3) | — | — | — | 18,00,000 | |
| — | 2.00 | — | — | ||
| SETC of LT outdoor Distribution Panel in 16 SWG CRCA Sheet Powder Coated having capacity 1000 Amps aluminium busbar consisting with FP ACB 2x800 Amp as incoming with 800 Amp Bus coupler and FP MCCB 2x315 A, 4x250 A & 4x100 A as outgoing along with protection measuring instrument and other accessories complete with fixing arrangement. (AQ-2) | — | — | — | 10,00,000 | |
| — | 1.00 | — | — | ||
| SETC of LT outdoor Distribution Panel in 16 SWG CRCA Sheet Powder Coated having capacity 1000 Amps aluminium busbar consisting with FP ACB 2x800 Amp as incoming with 800 Amp Bus coupler and FP MCCB 2x400 A, 2x315 A, 2x200 A & 2x100 A as outgoing along with protection, measuring instrument and other accessories complete with fixing arrangement. (WR-1) | — | — | — | 5,00,000 | |
| — | 1.00 | — | — | ||
| SETC of outdoor type LT panel in 16 SWG CRCA sheet powder coated having capacity 1000 A allumination Busbar consisting with FP ACB 2x800A as incoming with 800A Bus coupler and FP MCCB 4x650A, 4x400A & 4x250A as outgoing along with protection, measuring instrument and other accesories complete with fixing arrangement. (NGP-1) | — | — | — | 5,00,000 | |
| — | 1.00 | — | — | ||
| SETC of LT outdoor Distribution Panel in 16 SWG MS sheet Powder Coated having capacity 400 Amps aluminium busbar consisting with incoming 4 pole 2x250 Amp MCCB with automatic change over and O/g 2x200A FP MCCB , 6x125 A FP MCCB and 6x63 FP MCCB along with protection measuring instrument and other accessories complete with fixing. (BPQ-1) | — | — | — | 3,27,198 | |
| — | 300.00 | — | — | ||
| Supply and Spreading of 20 mm ballast in switch yard of different Sub-Station. | — | — | — | 4,22,661 | |
| — | 44.00 | — | — | ||
| Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete. | — | — | — | 24,164.8 | |
| — | 11.00 | — | — | ||
| FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete. | — | — | — | 50,901.4 | |
| — | 12.00 | — | — | ||
| Supply of Digital Clamp on Meter (Tong Tester) | — | — | — | 72,065.88 | |
| — | 30.00 | — | — | ||
| Supply of Safety belt Sefety full body K 102 for working in over head Excise Duty -- LINE (IS 3521:1999). MAKE - KARAM , RAYCHEM,Allen Cooper /SIMILAR. ACCEPTED MAKE/BRAND - ADHOC | — | — | — | 37,343.4 | |
| — | 30.00 | — | — | ||
| Supply of Industrial Safety Helmet as per IS specification no. 2925 or latest, with ISI marking, HDPE material, with air vent/holes, size 520-600 mm, with Rachet fit Adjustable, Chin strap adjustable,Color Yellow with Warranty for one year | — | — | — | 4,979.1 | |
| — | 60.00 | — | — | ||
| Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete. | — | — | — | 49,064.4 | |
| — | 62.00 | — | — | ||
| Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 - 2006 having 2.5 mm thickness upto 11 kV. | — | — | — | 2,70,326.2 | |
| — | 26.00 | — | — | ||
| Supplying, erecting, testing & commisioning GI sheet 1.6mm (16 SWG) caution board of size 250 x 200 mm duly painted with red oxide and enamel paint in marathi and hindi erected at position for HV/EHV (11000 Volts) erecting with compliance to IS 2551-1982. | — | — | — | 5,921.24 | |
| — | 25.00 | — | — | ||
| Providing & Fixing of printed instruction chart for (with minimum 700 x 1000 mm in size) treating persons suffering from electric shock, printed in Hindi, English & Marathi and duly laminated complete. | — | — | — | 4,513.5 | |
| — | 12.00 | — | — | ||
| Preparation of Substation Schematic Diagram on Auto Cad with one set of soft copy and 2 set of hard copy in hard glass frame for display in Sub-Station. | — | — | — | 35,225.76 | |
| — | 50.00 | — | — | ||
| Supply, erection, testing & commissioning of all material and casting of cement concrete foundation/ muffing, concreting in ratio 1:3:6. | — | — | — | 2,49,090 | |
| — | 200.00 | — | — | ||
| Painting of Rail/tubular poles with one coat red oxide and second silver paint. | — | — | — | 1,18,564 | |
| — | 7000.00 | — | — | ||
| "Provision of M.S. Work (i.e. Iron angle,Channel Nut bolt etc.)" | — | — | — | 5,71,690 | |
| — | 10.00 | — | — | ||
| Supply of Analog Earth Tester Hand operated type, 4terminal, Insulation resistance range:0-20 meg ohms with Testing Kit Similar to CIE Mode No: CIE/222, conforming ISS:2992/1987 OR Latest . Make: CIE, WACO,SAKOWA AND KYRITSU Only. | — | — | — | 74,104 | |
| — | 12.00 | — | — | ||
| Hand Held 100 KHz Digital Multimeter Brand: KUSAM-MECO. | — | — | — | 95,760 | |
| — | 2.00 | — | — | ||
| Infrared thermal imaging system (Thermal imaging camera) as per SCR specification Lr. No. E.207/TRD/Genl.Corr. dated 14.12.2023, having touch screen, temperature range from -20 degree celsius to 650degree Celsius, with rechargeable battery bank, telephoto lens & scanned image can be downloaded from USB port to PC, software should be license free so that it can be installed at multiple PC. Material shall procured from OEM or his authorized dealers only. Make- TESTO/FLIR/ FLUKE or similar. | — | — | — | 8,61,400 | |
| — | 12.00 | — | — | ||
| Provision of LED signage board of 8x3 feet PU coated allu. Section single side LED sign board with acrylic sheet with film for station name board. | — | — | — | 3,07,041.36 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Annex.V2024.pdf
GCCwithcorrecton.pdf
Annexure-VA1.pdf
TenderBookletSubstationT02.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .