| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹10.5 L+₹65,250 (6.65%)Rejected-AOC | L2 | Rejected-AOC Other than lowest | |
| 3 | L3₹10.5 L+₹73,005 (7.45%)Rejected-AOC | L3 | Rejected-AOC Other than lowest | |
| 4 | L4₹11.6 L+₹1.7 L (17.8%)Rejected-AOC | L4 | Rejected-AOC Other than lowest | |
| 5 | L5₹12.3 L+₹2.5 L (25.0%)Rejected-AOC 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L5 | Rejected-AOC Other than lowest |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
20 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER (AF) THOISE
GARRISON ENGINEER (AF) THOISE 19 FBSU, c/o 56 APO, PIN 937219
REPAIR REPLACEMENT AND CONVERSION OF LED TUBE LIGHT FITTINGS BUILDING LIGHTS AND BULK HEAD FITTINGS AT AF STN THOISE UNDER GE AF THOISE
2022_MES_541961_1
GEAF/T-21/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GARRISON ENGINEER (AF) THOISE
As per tender documents
7 documents required · 7 mandatory
₹500
GE AF Thoise
₹26,000
Yes
28 Sept 2022
30 Jul 2022
23 Aug 2022
30 Jul 2022
20 Aug 2022
6 Aug 2022
60 days
Amount
S&F in repair/replacment of LED tube light fitting, 20/ 24 watt, indoor decorative high lumen batten, including LED lamp 20/ 24 Watt more than 6500 K (yellow/white) and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- LHEXACP7IN1S022/ equivelent in Crompton/ Philips
S&F in repair/replacment of Inverter type LED tube light fitting, 20 watt, indoor decorative high lumen batten, including LED lamp 20 Watt more than 6500 K (yellow/white) having back up of 4 Hrs and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- LHEXACP7FN1W020/ equivalent in Crompton/ Philips/SYSKA
S&F in repair/Replacment GLAMAX SMART BATTEN (Tuneable White) browse through the colour options, alter the brightness indoor decorative high lumen batten, including LED lamp 20 Watt more than 6500 K (yellow/white) with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- LHLDAMNDUA8R020/ equivalent in Crompton/ Philips/SYSKA
S&F in repair/Replacment LED tube light fitting, 09/ 10 watt, indoor decorative high lumen batten, including LED lamp 09/ 10 Watt (yellow/white) and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- LHEXBTP7IN1W009/ Compact cat part No- L-599(Marina Square)/ Crompton cat part No- LDL-10-CDL/equivalent in SYSKA/Philips .
S&F in repair/Replacment LED bulb, B22 base, 9/10 watt,complete all as specified and as directed by Engineer-In-Charge. Make: Crompton/Havells/Philips/Osram
S&F in repair/Replacment T Bulb 10/12 Watt LED Bulb Base B22 Cool day Light complete all as specified and as directed by Engineer-In-Charge. Make Havells/Philips/Crompton/Havells.
S&F in repair/replacment of Decorative Wall light, gold finish fixture with white glass diffuser suitable for 7.5 W LED filament lamp E27 base. with connecting electrically to ceiling rose, complete all as specified and as directed by Engineer-In-Charge. Make: Havells Cat Part No -LHFOAKD1TZ1D060, Equivalent in Philips, Osram and Crompton.
S&F in repair/Replacement Surface mounted spotlight 7 W LED 6500 K in matt finish for premium aesthetics complete all as specified and as directed by Engineer-In-Charge. Make Havells Cat Pat No LHEEGBPGPH1W007 in equivalent in Crompton/Philips/SYSKA
S&F in repair/ replacment Flood Lights with best in class design & Robust heat sink along with class leading IP, IK & Surge of 30 W LED 6500 K protections for long lasting performance complete all as specified and as directed by Engineer-In-Charge. Make :- Havells Cat Part No LHEECNP7PB6J030 and Equivalent in Philips/Crompton/SYSKA
S&F in repair/ replacment Street / Bldng Security Lights with best in class design & Robust heat sink along with class leading IP, IK & Surge 30 W LED 6500 K protections for long lasting performance complete all as specified and as directed by Engineer-In-Charge. Make :- Havells Cat Part No LHEXAYP7PN6K030 and Equivelen in Philips and Crompton
S&F Ceiling Light 36W Aura-I pairs super bright LED's with highly efficient light smoothing optics to deliver superior illumination and energy savings complete all as specified and as directed by Engineer-In-Charge. Make - Crompton Greaves, Cat part No- LCPL-36-CDL(2x2)/equivalent models of Havell's/Philips/SYSKA
S&F in repair / Replacement of Decorative gate light Upto 1 N x 7 W LED Lamp - Moon 150 made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22 base complete all as specified and as directed by Engineer-In-Charge. Make :- Havells Cat Part No LHFXBON1TN5Q008 equivalent models of Havell's/Philips/SYSKA
S&F in repair / Replacement of Decorative, surface mounting, dome shaped pendant in green & black finishes Upto 7.5 W A60 LED Filament Lamp Black complete all as specified and as directed by Engineer-In-Charge. Make: Havells Cat Part No LHFHDPE1TN1K020 equivalent models of Havell's/Philips/SYSKA
Supply & Fixing in repair of sub main wiring with two runs of single core 2.5 Sq mm PVC insulated sheathed stranded copper conductor 650 / 1100 V grade with colour code and one run of 2.5 Sq mm ( 22 / 0.3 mm ) single core PVC insulated copper conductor green colour cable as earth continuity conductor drawn in and including PVC casing and capping of suitable size with all necessary fixture/accessories, and complete all as specified and directed at site by Engr-in-charge. Note :Two runs of 2.5 Sqmm copper cable, one run of earth wire of 2.5 Sqmm copper cable shall be measured & paid as one length.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .