| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC 104 SECTOR 4 PANCHKULA HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134112 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹18.7 L+₹1.5 L (8.42%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹20.1 L+₹2.9 L (16.6%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
21 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(I) 873 EWS
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
SPECIAL REPAIR TO BULDING NO T-339(STD) AND 337 (ENGR STORE) AND MISC WK AT BTC-I OF CBS AND SR TO BLDG NO T-189 (PIT OFFR COOK HOUSE) AT BTC-II MIL STN UNDER GE (I) 873 EWS
2023_MES_580667_2
NIT-81 of 2022-23
Open Tender
Civil Works
Item Rate
240 days
Bhaderwah
As per NIT
7 documents required · 7 mandatory
₹500
GE(I) 873 EWS
₹38,000
Yes
2 May 2023
28 Feb 2023
23 Mar 2023
28 Feb 2023
21 Mar 2023
7 Mar 2023
Amount
Demolition of cement concrete any description (unreinforced) in ground floors and pavings not exceeding 15 cm in thickness (below or above ground level) and disposal of unserviceable materials, debris and rubbish to a distance next 100m complete all as specified and directed.
75mm thick PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in sub base of floors incl form work complete all as specified and directed.
25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in levelling course incl form work complete all as specified and directed.
Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry over and incl 15mm thick screed bed in CM (1:6) and pointed in white or coloured cement to match complete all as specified and directed.
Coloured glazed ceramic tiles of 350x 250x 7mm/450 x 350x 7mm on vertical surfaces set and jointed in neat cement slurry and including 10 mm thick plaster in CM (1:4) and pointed in white or coloured cement to match complete all as specified and directed.
100 mm thick PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub base of flooring complete all as specified and ans directed .
Factory made precast (Rubber moulded) concrete designer chequered tiles any colour, shape and size not less than 30cmX 30cmX 20mm thick (Compressive strength not less than 250kg/Sqm), set jointed and pointed with grey cement and pigment over and including 20mm thick CM 1:6 screed bed or bedding layer complete all as specified and directed.
75mm Cement concrete 1:3:6 ,type C-2 (40mm graded aggregate) for plinth protection laid in slope 1:12 from out of the wall in alternative bays (n exc 2 Sqm) and finished fair on top without using extra cement 6mm wide joints shall be provided throughout thickness of plinth protection, all joints shall be filled with mastic filling comprising of one part of heated bitumen 85/25 grade and 3 parts of sand (all by weight) complete all as specified and directed.
Demolition of brick or stone boulder masonry work built in cement mortar including all quoins, arches, pillars, staging including taking out roots from walls including separation of serviceable material and removal of debries outside cantt area all as specified and directed.
Brick work with sub class 'B' bricks straight or curved on plan exceeding 6 mtr mean radius and built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
PCC 1:2:4, type-B0 using (12.5 mm graded stone aggregate) in lintels upto 1.50m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses upto 60cm in ht, coping, kneelers, apex stones, bed plates, kerbs , water troughs and like including weathering, slightly rounded or chamfered angles throating, as direected etc incl necessary form work complete all as specified and directed.
Demolition of coment concrete (unreinforced) any description and in any position not other wise complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in surface channels and drain etc. including necessary formwork complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moida, mitred/stopped ends etc, complete all as specified and directed.
Add of deduct for each 25mm girth or part thereof over or under 30cm ditto as per above item No 14 complete all as specified and directed.
Material and labour for rendering 15mm thick cement plaster in two layers cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. (WPC will measured separately)
Dismantling of plain or corrugated steel sheeting, any guage, thickness, including nainital or similar pattern roof coverings, ridges, hips , valleys and flashings complete all as specified and directed.
0.63mm thick Galvanised corrugated mild steel sheeting with two corrugation side lap fixed with 'L' type or 'J' types hooks and washers as in roofs, walls etc with grade of Zinc coating 275 complete all as specified and directed.
Re-fixing for 0.63mm thick Galvanised corrugated mild steel sheeting with two corrugation side lap fixed with 'L' type or 'J' types hooks and washers as in roofs, walls etc complete all as specified and directed.
0.80mm thick plain galvanised mild steel sheeting in ridges, hips, valleys gutters, drip and straight flashings complete all as specified and directed.
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling posts or struts embedded in Concrete, brick work, masonry, etc. (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for any position complete all as directed.
Steel work in tubular trusses including special shaped washers etc.complete using ERW or including butt welded tubes conforming to I S 1161-1979 grade St Fe 240 complete all as specified and directed.
Erection and fixing only mild steel work in tubular trusses including special shaped washers etc.complete using ERW or including butt welded tubes conforming to I S 1161-1979 grade St Fe 240 complete all as specified and directed.
Excavating in post holes (or similar holes) each (any type of soil) n exc 0.5 cu. m, getting out, returning, filling and removing of surplus soil where as directed
PCC 1:2:4 Type B-2 (40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed.
Dismantling timber scantlings filletes, rails, posts, rafters, purlins, etc under 40 sq. cm in section, in any position (Unframed work) complete all as specified and directed.
Clean Second class hard-wood in scantlings fixed with nails / screws etc, in any position complete all as specified and as directed.
Preparation of new wooden surfaces applying two coat of synthitic enamal paint over one coat of primer complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulb, insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets including removal of Debries outside Cantt area complete all as specified and directed.
Non asbestos fibre cement building boards 4 mm thickness fixed or laid / inserted to timber/ GI / Aluminium frame work with screws complete all as specified and directed.
Gl frame work of size grid 605x605mm for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners hanged with 3 mm dia GI wire and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed.
12 mm thick prelaminated particle board, interior garde, prelaminated one side with decorative choice lamination,including beading piece around leaf fixed for wall cladding etc with screws to timber frame work complete all as specified and directed.
Re-fixing in same opening chowkhats or frames with shutters (without taking off shutters from the frame) area n exc 1.50 sqm each incl iron mangery complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n exc 4 sqm each incl iron mangery complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) area n exc 1.50 sqm each incl iron mangery complete all as specified and directed.
Pressed steel frames for doors with one or more rebates including necessary fixing lugs hinges, lock stike plate etc, size 165 X 60 mm complete all as specified and directed.
30 mm thick Flush shutters, solid core construction with block boards core and plywood face panels commercial type on both sides complete all as specified and directed.
35mm thick second class hard wood, Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of complete all as specified and directed. framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, with glazing bars, dovetailed or welded complete all as specified and directed.
Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, without glazing bars, dovetailed or welded complete all as specified and directed.
Mild steel pressed handles of size 150mm long, oval type, stove enamelled black complete all as specified and directed.
100 mm long mild steel butt hinges, Medium weight cold rolled mild steel and fixed complete all as specified and directed.
Mild steel barrel tower bolts, stove enamelled black, with bright bolt 200mm long complete all as specified and directed.
Mild steel 250mm long sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with stainless steel wire staples complete all as specified and directed.
Hacking out old broken glass (any thickness, size quality or description from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
3.00mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and directed.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with stainless steel wire staples, fixed in repair complete all as specified and directed.
Preparing of new plastered surfaces and applying two coats of cement base paint over one coat of primer on newly plastered surfaces and on walls all as specified and directed.
Preparing of new steel surface exceeding 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Preparing of old steel surface exceeding 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
25 mm dia CP curtain rod with brackets, stops, side etc, fixed in repair complete all as specified.
Aluminium Hat and coat hooks, solid body, 175mm to 250 mm fixed in repair complete all as specified and directed.
Glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and fuard rail fixed in repair complete all as specified.
Taking up or down steel water tubing and connections 15mm bore including cleaning for refixing or removing to store complete all as specified and directed.
15mm bore galvanized tubing (Medium grade) with all fittings including short lengths, fixed to walls, concealed in wall and ceilings or laid in floors complete with all fittings (such as bends, back nuts, diminishing pieces, caps and plugs, unions etc) all as specified and directed.
S&F in repairs for 15mm bore Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and as directed.
Point wiring with multi stranded copper conductor of size 1.5Sqmm PVC insulated unsheathed FRLS cable in existing concealed conduit and accessories of suitable size including 1.50 Sqmm copper earth wire (green colour) FRLS Cable for one light point or fan point or bell point controlled by one No, one way switch using cable of different insulation colour for colour coding including 3mm thick laminated sheet cover on existing mild steel sheet or cast iron boxes including making good to disturbed surfaces of wall / floor, complete all as specified and as directed.
All as per the description of Serial Item No 60 here-in-before but for one 3/5 pin socket outlet 5 Amp independent, complete all as specified and as directed.
All as per the description of Serial Item No 60 here-in-before but for one 3 pin socket outlet 5 Amp on same board, complete all as specified and directed.
All as per the description of Serial Item No 60 here-in-before but for one 3 pin socket outlet 15 Amp independent board using cable of size 4 Sqm with 2.50 Sqmm copper conductor in green colour for as earth continuity conductor all as specified and directed.
Switch piano, flush type, 5 Amps, single pole, one way, complete all as specified and directed.
Socket outlet 2 in 1, 5 pin, 5 Amps, single pole, one way, complete all as specified and directed.
Switch socket outlet combination universal type, 2 in 1, 3 pin 5Amp flush type, 240 volts, complete all as specified and directed.
Switch socket outlet combination universal type, 2 in 1, 3 pin 5 and 15 Amp, flush type, 240 volts, complete all as specified and directed.
LED light fitting 1x16 watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up cable of copper conductor size 3-core, 23/0.0076 from ceiling rose to light fitting connector complete including taking down old fitting all as specified and directed.
Bulk head luminaries complete with all accessories suitable for and including 1 x 10 Watts LED lamp including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230 Volts 50 Hz, IP 65 complete all as specified and as directed.
LED recess luminaire, 2' x 2' size, 34 watts with high with high efficiency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for roof ceiling including making connection from ceiling rose to fitting with PVC insulated sheathed flexible copper conductor cable of size 0.75 Sqmm complete all as specified and directed.
Ceiling rose surface bakelite three terminals 240 volts complete all as specified and directed.
Sheet metal enclosure factory made single door for DB 240 volts with 200 Amps rated bus bar SPN 8 Way complete all as specified and directed.
MCB SPN 40 to 63 Amp 10 KA 240 Volts, 'C' Series, complete all as specified and directed.
MCB SP 5 to 32Amp 10 KA 240 Volts, 'C' Series, complete all as specified and directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 16 Sqmm 2 core on wall including taking down old cable, complete all as specified and directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point and testing on completion includig dismantling of existing earthing complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Underground DWC pipe of 40mm for cable protection suitable for heavy duty electric cable 1100 V grade coplete all as specified & directed.
Storage water heater (Geyser), vertical type, of 25 ltr capacity of inner tank, outer tank, syphon assembly, thermostat heating element upto 2KW, safety valve etc complete all as per manufacturer design and specifications including making of all fixing arrangements complete having BEE Five Star Rating including grouting of fastner /nuts and bolts and necessary PCC work all as specified and directed. Make:- BAJAJ/Venus / Recold / havells
20mm bore galvanized tubing (Medium grade) with all fittings including short lengths, fixed to walls, concealed in wall and ceilings or laid in floors complete with all fittings (such as bends, back nuts, diminishing pieces, caps and plugs, unions etc) all as specified and directed.
20mm bore gun metal globe or gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete all as specified and directed.
m/s vaid contractor and builders
VEER TRADERS
Bidder Name
m/s vaid contractor and builders
A S CONSTRUCTION
VEER TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .