| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹26.4 L+₹2.4 L (9.77%)Rejected-Finance 79 MAHATMA GANDHI MARKET SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹32.9 L+₹8.8 L (36.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹35.4 L+₹11.3 L (46.9%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹44.6 L+₹20.5 L (85.3%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
31 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(I)866EWS CARNICOBAR
GE(I)866EWS CARNICOBAR
PROVISION OF ALL WEATHER GROUND TRAINING SHELTER WITH TOILETS FOR SECURITY AND QRT PERSONNEL AT AF STN CARNICOBAR
2021_MES_492106_1
8549/21-22/E8
Open Tender
Civil Works
Item Rate
180 days
AREA UNDER GE(I)866EWS CARNICOBAR
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE(I)866EWS
₹48,000
Yes
5 Feb 2022
3 Dec 2021
6 Jan 2022
3 Dec 2021
31 Dec 2021
18 Dec 2021
60 days
Amount
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exc 1.5 mtr deep and getting out complete all as specified
Material and Labour for PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation filling & mass concrete complete all as specified.
Returning, filling in and including spreading, levelling watering and well ramming in layers, each layer not exceeding 25 cm thick complete all as specified.
Removal of surplus spoil to a distance not exceeding 50 mtr and depositing where directed at a of level not exceeding 1.5 mtr above the starting point complete all as specified.
M&L for providing precast cement concrete (1:3:6) type C1 using 20mm graded stone aggregate as in block masonary with solid blocks, exc 10cm in width and setting in cement mortar 1:6 complete all as specified and as directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wires (annealed) not less than 0.9 mm dia or secured with clips complete all as specified and as directed.
M&L for TMT bars 6mm to 8mm dia, cut to length bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends abd binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for reinforced cement concrete M-20 (nominal mix) (1:1.5:3) using 20mm graded stone aggregates as in column, plinth beam and litel beam complete all as specified and as directed.
M&L for providing formwork to the sides of column, plinth & lintel beam for flat surface of concrete of rough finished surface of concrete complete all as specified and as directed.
M&L for providing reinforced cement concrete M20(Nominal Mix) (1:1.5:3) (using 20mm graded stone aggregate) as slabs supportede on walls, beams and column in flooors, roofs, landing, balconies, canopies, deck slab and in shelves complete all as specified and as directed.
M&L for providing formwork to the suspended slab such as roof slab, floor slab, landing and similar work not exceeding 20mm thick (Horizontal or sloping) for rough finished, flat surface of concrete complete all as specified and as directed.
M&L for 15mm rendering in cement mortar (1:4) on roof surfaces mixed with water proofing compound @3Kg/50Kg of cement or as per manufecturer's instruction ,finished the surface even and smooth without using extra cement all as directed by Engineer in Charge. Note: Water proofing compound shall be measured & paid seperetely)
M&L for water proofing treatement to RCC roof slab including parapet comprising with the following course of treatement/ specifications from bottom to top:- (a) Applying bituminous primer @ 0.40 ltrs per sqm over plastered surfaces of roof including parapet surfaces. (b) One layer of APP based polymeric membranes of approved manufacturers, 3 mm thick, weight not less than 3.6 kg/sqm, reinforced with non woolen polyster fabric or weight not less than 150 gms/sqm. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet walls and shall be finished by a membrane flashing. Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer's instructions. (ii) A minimum overlap of 100 mm and 75 mm should be made in the end sides of polymeric membranes respectively and sealed all overlaps and joints as manufacturer's instructions. (c) Applying two coats of Aluminium paint on top of APP membranes.
Supply only integeral water proofing compound ,ISI marked, best quality complete all as specified
M&L for rendering 15 mm thick cement plaster in CM (1:6) on fair faces of brick work or concrete surfaces of wall and finishing the surface even and smooth (without using extra cement) complete all as directed by Engineer in Charge.
M&L for rendering 15mm thick cement plaster in CM (1:4) on fair faces of brick work or concrete surfaces of wall and finishing the surface even and smooth (without using extra cement) complete all as directed by Engineer in Charge.
M&L for rendering 10 mm thick cement plaster in CM 1:3 on fair faces of brick work or concrete surfaces of ceiling and finishing the surface even and smooth complete all as directed by Engineer in Charge.
M&L for preparation of new surfaces of wall and applying two coat of oil bound distempering over one coat of primer including chalk whiting complete all as specified and as directed.
M&L for preparation of new plastered surface of walls and applying two coats of antifungal acrylic emulsion paint over a coat of acrylic emulsion primer complete all as specified and as directed.
M&L for preparation of new plastered or unplastered surface of ceiling and applying three coats of white wash complete all as specified and as directed
M&L for hardcore of broken stone or boulders gauge n exc. 63mm, deposited, spread and levelled in layers n exc.15 cm thick, watered and rammed to a true surface complete all as directed by Engineer in Charge.
M&L 75 mm thick plain cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in flooring complete all as specified and as directed by Engr-in-Charge.
S&F solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS sqare tube, all as directed.
S&F factory made, solid panel PVC door shutter, 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frames shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame at site as specified.
S&F100mm size of stainless steel butt hinges, medium weight, cold rolled complete all as directed by Engineer in Charge.
S&F 100mm size extruded aluminium alloy handles, fabricated type complete all as directed by Engineer in Charge.
S&F 150mm size aluminium, anodised barrel tower bolt of extruded section complete all as directed by Engineer in Charge.
S&F non skid coloured ceramic colour tiles 400mm X 400mm X 7 to 8mm thick in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick cement screed bed in CM 1:4 complete all as specified and as directed
S&F coloured glazed ceramic colour tiles 450mm X 350mm X 7 to 8mm thick in vertical surfaces set and jointed in neat cement slurry and pointed in coloured cement to match including rendering 10mm thick in cement plaster 1:4 complete all as specified and as directed.
S&F aluminium frames for doors, windows, ventilators with one or more rebates including joining joining cleats for fixing etc complete all as specified and as directed.
S&F anodised aluminium window and ventilator shutter, side hung type type without sash bars, aluminium section weighing 0.55 kg/m including necessary joining cleat, glazing clips, rubber neoprene packing, anodised aluminium snap beading, scews anodised aluminium fittings such as peg stay 150mm long (01 No), hinges type B-21 100mm long (02 No) suitable handle (01 No) complete all as specified and as directed.
S&F 5.5 mm thick frosted sheet glass,ordinary quality and glazing with oil puttyin square not exceeding 0.5 sqm each pane complete all as specified and as directed.
S&F brass cromium brass plated fancy type bib taps 15 mm bore screwed down screwed for iron pipe or for brass complete all as specified and directed
S&F PTMT grating with 100mm dia with or with out waste hole complete all as specified and directed
S&F pillar taps cast copper alloy with capstan head chromium plated fancy type screwed down high pressure with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed (dia of bore 15mm) fixed in repair.
S&F angle valve 15mm dia bore chromium plated cast copper alloy with long shank and cup (concealed type) complete all as directed by Engineer in Charge.
S&F PVC waste pipe as in repair 32 mm dia having length of 450 mm complete all as specifieid.
S/F in repair Vitreous China wash down water closet pan (pedestal pattern), size 550x400mm but including brackets, coupling and waste pipe complete all as specified and directed.
M&L SWG drain pipes of 100 mm bore grade ‘A’ laid in trenches and jointed and tested complete all as specified & directed by the Engineer-in-Charge.
M&L Concrete bed to drain pipe including packing under hanching against the side of pipes, 100 mm bore, in cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) after laying and testing of pipe complete all as specified and directed.
M&L for PCC(1:2:4) type B-1 using 20mm graded stone aggregate as in haunching and bed in manholes and PCC bend for top of manhole brick work etc complete all as specified and directed.
M&L precast RCC (1:2:4), type B1 (using 20mm graded agg) as in cover slabs, set in cement mortar (1:6) complete all as directed by Engineer in Charge.
S&F PVC (SWR) pipes 110mm dia single socketed in length with rubber ring joints liad in trenches or in floors complete all as specified and as directed.
S&F 110 mm dia PVC (SWR) bends any radius complete all as specified and as directed.
S&F 110 mm dia PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and as directed.
S&F 110 mm dia PVC (SWR) Gully trap any radius complete all as specified and as directed.
S&F in repairs wash basins, vitreous china white size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets, cutting for and pinning in ends of brackets complete all as specified and as directed
S&F tubular towel rail, brass chromium plated, 20mm dia, D type, 60Cm long between flanges complete all as specified and as directed.
S&F PVC Connections 15mm size 600mm long with PTMT nuts complete all as specified and as directed.
S&F Waste coupling 32mm bore for wash hand basin cast copper alloy complete all as specified and as directed.
S&F PVC (SWR) floor trap oulet dia 110mm, plain with grating including jointing with solvent cemet complete all as specified and as directed.
S&F Soap dish, vitreous china white, approximated sixe 160 x 160 x 90 mm complete all as specified and as directed.
S&F GI Tubing medium grade 15mm bore laid in trenches and as wall complete including cuttings chases in walls and making good, cutting portion all as specified and directed.
S&F rotational moulded polythyene 500 litrs water storage tanks cylindrical vertical with closed top, HDPE double layered , hoisted and fixed in position including 20mm dia float valve brass fitting complete all as specified and directed.
S/F in repair PVC valveless, syphonic action type, flushing cistern low level, white, with inlet, ball valve,float and handle including brackets capacity 10 ltr complete all as specified and directed.
Surface dressing n exc 15cm deep in any type of soil all as directed by Engineer in Charge.
M&L 100 mm thick cement concrete 1:4:8, type C2 (using 40mm graded stone aggregate) as in flooring complete all as specified and as directed.
Exacavation in post holes (or similar holes) each n exc 0.5 cum getting out returing filling in and ramming earth or broken rubble mixed with earth around in layers removing surplus soil to distance n exc 50 m and making good surface of loose /soft soil complete all as directed by Engineer in Charge.
M&L for plain cement concrete 1:2:4 Type B2 (using 40mm graded aggregate) as in foundation, filling and mass concrete complete all as directed by Engineer in Charge..
S&F steel work in tabular truss including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS-1161-1979 of grade St-240 complete all as specified and as directed.
S&F plates (plain or chequered) Channels, square, cut or notched (ordinary and counter sunk) forming holes without any attachment of Fe-410-W (Grade E-250) quality B complete all as specified and as directed.
S&F mild steel works such as wind ties for roof including securing with bolts etc and similar work using rolled section confirming to Fe-290 Gde E-165 complete all as specified and as directed.
S&F prepainted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength 550 MPA as in roof covering in roof covering incudingl ridge fixed with self tapping screws / L type or J type hook as specified.
All as per Sl item No 64 here-in-before but as in ridge / flashing board of width and girth not less than 610mm.
M&L for preparation of new or previously untreated steel surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide primer complete all as specified and as directed
M&L for 20mmbre GI pipe medium grae including necessary fittings, laid in trenches/wall/floors complete all as specified & directed byEngineer in Charge.
M&L for insersion of Tee and tal piece to existing pipe lines and jointing with and including materias all as directed by Engineer in Charge.
M&L for Gun Metal Glob or gate vave of size 20mm dia with iron wheel head, screwed both ends for iron pipe and fixed including taking out of old valv complete all as directed by Engineer in Charge.
M&L Providing cement concrete 1:2:4 type B-1 using 20 mm graded aggregate as in kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 - 2006 of 60 mm thickness, M-35 Grade including with grey cement and pigment complete all as specified and as directed.
S&F Mild steel screw bolts (machine made) 5 to 10mm dia of shank with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or squarae nut, n.exc 5cm long complete all as specified and as directed.
S&F in repair Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed.
M&L Vetrified Ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match ,light shade, incl 15 mm thick screed bed in CM (1:6) complete all as specifeid and directed.
M&L for point wiring with 1.5 sqmm PVC insulated unsheathed copper conductor multistranded 1100 volts grade single core including one single core 1.5 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor (colour green)drawn through and including PVC casing and capping with all accessories fixed to all type of electrical fittings and earth terminals /earth dolly, complete with PVC rectangular block and rawl plugs fixed to walls / ceilings/ roofs with & including. 3mm thick MS sheet fabricated terminal boxes , flush mounted for mounting of switches , switch socket combination , fan regulator etc as required with 3mm thick hylam sheet top cover all as specified & as directed for the following :- .
One light /Ceiling fan/Exhaust fan point controlled by one Switch and regulator or without regulator.
One 3 pin switch socket 5 Amps independent board.
One 3 pin switch socket 5 Amps same board.
All as per item No.73 above but with using 2.5 sqmm PVC insulated multi stranded copper conductor for independent switch socket out let 3 pin 15 Amps Points.
Supply & fixing switch piano 5 Amps, single pole, AC, 230 Volts, flush type, ISI Mark.
Supply & fixing switch socket combination out let 5 pin 5 Amps flush type.
Supply & fixing Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal.
Supply and Fixing Ceiling rose siz 65x50mm, three terminal, 3 phase / PVC / polycarbonate, isolated body.
S&F LED light fittings 18/20watt with electronic driver ultra slim with extruded poly arbonate difuser for glare free light distribution including connecting u wth white twin core flexible cord , Make: Havells Lumiline Cat part No-LHEXBQP6IN1W018 or equivalent model in Philips/Crompton/Bajaj as approved.
S&F exhaust fan 300mm sweep suitable for single phase 230/240 volt, 50 Hz, AC supply complete with louveres shutter including fixing / grouting in wall and including connecting three core 1.5sqmm copper conductor flexible cble from ceiling rose to exhasut fan complete all as specified & directed by Engineer in Charge.
S & F sheet metal enclosure for MCB, DB, Double door, SPN, 8 ways, 240 Volts with 200 Amps rated bus bar all as specified.
S & F sheet metal enclosure for MCB, DB, Double door, SPN, 4 ways, 240 Volts with 200 Amps rated bus bar all as specified.
S & F MCB SP 06 Amps to 32 amps 240 volts all as specified.
S& F MCB SPN ,32 Amps, 240 volts all as specified.
Material and laboure PVC insulated ,armoured,heavy duty electric cable ,LTUG, with aluminium conductor ,1100 volts grade ,cross sectional area 10 sq mm ,4 core all as directed by Engr-in-charge. Note : Earth work shall be measured & paid seperetely.
Supply and laying of DWC Pipe of size 50/38 for cable protection complete with coupler etc. all as specified and directedby Engr-in-charge.
M&L for earthing complete with GI earth plate electrode of size 600mx600mmx6 mm, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr deep below normal ground level, connected to GI earth wire 4 mm by by means of bolts, nuts, check nuts and washers of GI earth wire and connected to earthing test point / distribution board/equipments or any other indicated situation all as shown in electrical plate No 3 of SSR Part I (2009) and testing on completion including necessary excavation in any type of soil, returning filling, removing of soil and 1.5 mtr length GI medium grade 20mm dia pipe with funnal and wire mesh, PCC chamber of (1:2:4) type B1 using 20 mm grade stone aggregate, 40 mm thick RCC 1:2:4 type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 150mm c/c on both ways pre cast chamber cover with lifiting handle 16mm dia round bars, Gi pipe medium grade 15 mm dia for earth wire protaction including charcol, common salt complete all as specified and directed. (Note:- GI earth wire above to 7.5 mtr long shall be measured and paid separetly)
Gulmarg Electrical Service
KML CONSTRUCTION
CS CONSTRUCTION
M/s Karbhagam Sales Agency
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .