| 1 | L1₹20.9 LAccepted-AOC 44B CIRCULAR GARDEN REACH ROAD KOLKATA 700 023 | KOLKATA | WEST BENGAL | 700023 | L1 | Accepted-AOC Being L1 bidder. | |
| 2 | L2₹22.6 L+₹1.7 L (7.92%)Rejected-Finance 51 1 FULBAGAN ROAD BAGHAJATIN KOLKATA 700086 WEST BENGAL | KOLKATA | WEST BENGAL | 700086 | L2 | Rejected-Finance Rejected due to higher than L1 biidder. Amount considered after deduction of schedule of credit amount i.e. Rs. 31830.00 | |
| 3 | L3₹23.0 L+₹2.0 L (9.75%)Rejected-Finance 1 9 | PRAYAGRAJ | UTTAR PRADESH | 211001 | L3 | Rejected-Finance Rejected due to higher than L1 biidder. Amount considered after deduction of schedule of credit amount i.e. Rs. 31830.00 | |
| 4 | L4₹27.7 L+₹6.7 L (32.1%)Rejected-Finance | L4 | Rejected-Finance Rejected due to higher than L1 biidder. Amount considered after deduction of schedule of credit amount i.e. Rs. 31830.00 | |
| 5 | L5₹30.5 L+₹9.5 L (45.5%)Rejected-Finance 6A BANAMALI GHOSHAL LANE KOLKATA 700034 | KOLKATA | WEST BENGAL | 700034 | L5 | Rejected-Finance Rejected due to higher than L1 biidder. Amount considered after deduction of schedule of credit amount i.e. Rs. 31830.00 |
Tender Value
₹28.1 L
EMD Value
₹56,260
Closing Date
31 Dec 2020, 6:00 pmClosed
GE CENTRAL, KOLKATA
Garrison Engineer (Central) Kolkata, T-37, Napier Road, Hastings, Kolkata-700022
SPECIAL REPAIRS TO UG CABLE GATE LIGHTS SECURITY LIGHTS AND OTHER ALLIED WORKS AT AFCB AND VARIOUS MINOR AND REVENUE WORKS UNDER GEC KOLKATA
2020_MES_397183_2
8325
Open Tender
Miscellaneous Works
Item Rate
180 days
Kolkata
As per tender documents
10 documents required · 10 mandatory
₹500
GE CENTRAL KOLKATA
₹56,260
Yes
16 Jan 2021
15 Dec 2020
2 Jan 2021
15 Dec 2020
31 Dec 2020
19 Dec 2020
15 Dec 2020 - 18 Dec 2020
Amount
Surface excavation n.exc 30 cm deep and averaging 15 Cm deep and getting out in soft / loose soil complete all as specified and as directed.
Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc. for laying of XLPE cables and other works and getting out in soft / loose soil. complete all as specified and directed.
All as per Item No.3 above but for each additional 1.5m or part thereof in depth beyond the first 1.5 m
Excavating in post holes (or similar holes) each n. exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25Cm, watering and removing surplus soil to a distance n. exc 50m and making good surface in soft/loose soil as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 Cm as in soft / loose soil complete all as specified and directed.
Removing excavated material of soft / loose soil not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Material and Labour for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge. Note:- Thickness after punning down shall be measured for payment.
Material and Labour Cutting holes into or through brick n.exc 150 Sqcm in walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and directed.
Supply and laying in trenches Bricks, sub class 'B' over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge.
Material and Labour Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Material and Labour Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Material and Labour Plain cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Material and Labour Plain cement concrete 1:2:4, type B-1 (using 40 mm graded stone aggregate) as in coping of poles / struts and other similar location including necessary formwork complete all as specified and directed.
Supply and fix aluminium anodised powder coated three track sliding window frame with shutters ( two panels of glazed shutter and one panel of wire mesh shutter) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements etc. complete and glazing with 5 mm thick tinted glass to aluminium frame work using rubber gasket and stainless steel wi\re cloth of 0.36mm nominal dia of wire fitted with screws and washer. The section of frame and shutter is as under complete all as specified and as directed:- (A) Sections for frame (i) Top and sides 123mmx 29.70mmx 1.50mm thick not less than 1.50Kg /m (ii) Bottom 123 x 29.70 x 1.50 mm thick not less than 1.502 Kg /m. (B) Sections for shutter (i) 'H' section 39 x 20 x 1.50 mm thick (ii) 'Interlock' section 39 x 20 x 1.50 mm thick (iii) 'H' section 41 x 20 x 1.10 mm thick . Note:- Cost of wire cloth and glazing shall deemed to be included in the rate quoted by the tenderer.
Supply and fix Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
Supply and fix Anodised aluminium anodised window and ventilator shutters, sliding / side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21 100mm long (2 Nos) suitable handle (1 No) including 4.8mm thick tinted glass, ordinary quality and glazing with aluminium / wooden beading in Square exc 0.50 Sqm in each pane complete all as specified and directed by Engineer-in-Charge. Note:- Cost of glazing shall deemed to be included in the unit rate quoted by the tenderer.
Material and Labour for Mild steel Framed work as Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
Supply and Fix Mild steel work as Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-410W(GdeE-250) qualityB complete all as specified and as directed.
Supply and fix Mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Supply and fix Rolled mild steel plate Fe-290 ( Gde-E-165) ( Plain or chequered) with riveted, bolted or welded attachment etc complete all as specified and as directed.
Supply and fix Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete
Supply and fix Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Supply and fix Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Material and Labour for 75 mm thick, plain cement concrete 1:4:8, type D2 (using 40 mm graded stone aggregate) as in sub base of floor complete all as specified and directed.
Material and Labour for 40 mm thick, plain cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate) as in flooring/ pavings, etc complete all as specified and directed.
Material and Labour for 25 mm thick, plain cement concrete 1:2:4, type B0 (using 12.5 mm graded stone aggregate) as in flooring complete all as specified and directed.
Roughening of surface of old concrete floor by picking, sweeping, cleaning and washing down with water to remove dust etc complete all as specified and as directed.
Materials and labour for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm, in floors etc,set and jointed in neat cement slurry and jointed in white or coloured cement to matcht as on vertical surfaces such as skirtings, dados, risers etc over 10mm thick backing course in CM 1:4 complete all as specified and directed.
Materials and labour Glazed ceramic colour tiles in vertical surfaces such as skirtings, dados, risers etc of size 300 x 200 x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement ot match the tiles over and including 10mm thick backing course in CM 1:4 for receiving tiles complete all as specified and as directed.
Material and Labour Preparation of new steel surfaces of any description, over 10 Cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint of any colour/ tint over a coat of red oxide primer complete all as specified and directed.
Material and Labour Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
Materials and labour Preparation of newly plastered wall surfaces of any description and applying two coats of acrylic distemper of any colour / tint over a coat of primer and 3mmn thick wall care putty complete all as specified and directed.
Supply and fix Stainless steel kitchen plate rack made out of 1.00mm thick sheet for size 775mm x 750mm x 250mm fixed on wall with screw, washers complete all as specified and as ditected. Make:- Blue Star Cat Part No. SSKPR-314 or equivalent make as specified in Particular specification.
Materials and Labour Scrapping, cleaning and preparation of surfaces of all electric pole and applying black bituminious paint to the section of 15Cm x 15 Cm on 2 m from ground level for writing MES no/ pole no of size 15mm x 120mm in white synthetic enamel paint for each pole complete all as directed by Engineer-in-Charge.
Supply and fix LED flood light luminaries of 80 Watt with made in pressure diecast housing and high opt out emitter LED and IP66 proction complete all as specified and as directed including takig down old unserviceable flood light.
Supply & fix 15mm bore stop cock, cast copper alloy, chromium plated , screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
Supply and fix Straight through XLPE cable jointing kit 1100V ( Earthed) grade for indoor termination heat shrinkable type complete with jointing materials and accessories suitable for XLPE armoured aluminium conductor cable of size 25 Sqmm to 50 Sqmm 3.5 core complete all as specified and as directed.
Supply and fix Straight through XLPE cable jointing kit 1100V ( Earthed) grade for indoor termination heat shrinkable type complete with jointing materials and accessories suitable for XLPE armoured aluminium conductor cable of size 70 Sqmm to 150 Sqmm 3.5 corecomplete all as specified and as directed.
Material and labour Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size including taking down old unserviceable Danger notice plate complete all as specified and directed.
Supply and fix On load Changeover switch 125 Amps, 4 pole with advance neutral open execution type including taking down old unserviceable one.
Supply and fix LED driver with operating voltage 180-270V AC 50/60 Hz output voltage 36V DC / 2.8 Amps power factor 0.95 driver DC/2.8 Amps including taking down old unserviceable one by taking down Led street light / security light and refixing in the same position after necessary fault finding/ repairs complete all as directed by Engineer-in-Charge.
Supply and fix CP connection 600 mm long fixed to 15mm GI pipe complete all as specified and directed.
Supply and Fix Aluminium strips 25mmx 3mm with saddles and fixing screws etc for roof conductors and down conductor above ground complete all as specified and as directed.
Supply and fix GI strip of size 32 x 6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as directed .
Materials and labour Earthing complete with galvanised steel earth plate electrode 60 Cm x 60 Cm x 6.00 mm thick buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strips 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip projected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 Cm c/c both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I earth pit with all accessories complete all as specified and as directed. Note:- Main earthing lead beyong 7.5m shall be measured and paid against relevant item of these schedule.
Materials and labour Earthing complete with galvanised steel earth plate electrode 60 Cm x 60 Cm x 6.00 mm thick buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strips 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip projected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 Cm c/c both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I including taking out of old unserviceable earth pit with all accessories complete all as specified and as directed. Note:- Main earthing lead beyong 7.5m shall be measured and paid against relevant item of these schedule.
Supply and fix Air termination aluminium single pointed rod 12 mm dia, 300 mm long complete all as specified and as directed.
Supply and fix Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 nos 8mm dia 25mm long hex head screw complete all as specified and as directed.
Material and labour Point wiring with PVC insulated and unsheathed FRLS grade cable single core multistranded copper conductor 1.5 Sqmm size, 1100 volts grade cable confroming to IS - 694 1990 drawn through and including PVC casing and caping of suitable size with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 1.5 Sqmm multistranded PVC insulated FRLS grade and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one switch scoket outlet 5 amps / fan point on independent board complete all as specified and as directed.
Material and labour Point wiring with PVC insulated and unsheathed FRLS grade cable single core multistranded copper conductor 2.5 Sqmm size, 1100 volts grade cable confroming to IS - 694 1990 drawn through and including PVC casing and caping of suitable size with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 2.5 Sqmm multistranded PVC insulated FRLS grade and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one 15 Amps switch scoket combination point on independent board complete all as specified and as directed.
Material and Labour Concealed Point wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core, unsheathed, copper conductor cables drawn through and including PVC conduits Concealed in walls, ceiling etc with all fittings and accessories of PVC conduits 20mm dia, ISI marked, medium grade (like Tee, bend etc.) complete fixed to walls/ceiling etc. with and including 1.5 Sqmm (nominal area) FRLSH PVC insulated, unsheathed, multistranded, single core, copper cable green in colour as in earth continuity wire connecting to common earth point and 1.6 mm thick mild steel sunken terminal boxes of suitable size with 3 mm thick hylam sheet top cover fixed with suitable size of brass screws for mounting switches, sockets, regulators etc complete for one light point Flame proof complete including cutting, chasing the surface and then making good the same in CM 1:3 complete all as specified and directed by the Engr-in-Charge.
Supply and fix Switch socket combination multipurpose 2 in 1, 3 pin 5 /6 Amps 230 volt flush type complete all as specified and as directed.
Supply and fix Switch socket combination multipurpose 2 in 1, 3 pin 5 /15 Amps 230 volt flush type complete all as specified and as directed.
Supply and fix Switch piano flush type, single pole one way 6 Amps complete all as specified and as directed.
Supply and fix Ceiling rose surface bakelite three terminals 230 volts complete all as specified and as directed.
Supply and fix Electronics fan regulator, step type, AC 120/ 280 Volts, white / Ivory finish complete all as specified and as directed.
Supply and fix Metal Industrial Exhaust fan 300mm, 1400 RPM, 230 Volts, 50 Hz, single phase TURBO HDEF ISI marked, grey colour including louvers and cutting of existing wall to the size of exhaust fan and making good the disturbed surfaces complete all as specified and as directed.
Supply and fix Padestal fan 450mm sweep, rated power 160 watts, rated speed 1400 RPM complete all as specified and as directed.
Supply and fix Wall mounted fan 400mm sweep, 230 volts, 50 Hz, single phase including testing and commissioning complete all as specified and as directed. Make:- Havells Airboll Hi speed or equivalent model as specified in Particular specification.
Supply and fix Wall mounted fan 300mm sweep, 230 volts, 50 Hz, single phase including testing and commissioning complete all as specified and as directed. Make:- Havells Swing Desire or equivalent model as specified in Particular specification.
Supply and fix Ceiling fan AC Single Phase 240 Volts of size 1400mm sweep, 400 RPM metal body and 3 blade, powder coated mettallic finish including fastner, nuts, bolts for fixing properly including all fixing arrangements complete all as specified and asd irected. Make:-Havells SS-390 or equivalent model from make as specified in PS.
Supply and fix Flame proof LED tube light fittings, 16/ 20 watt, 230V, box type epoxy powder coated CRCA sheet housing with relector cover channel with electronic ballasts, bipin holders connector block etc complet with all accessories including necessary connection complete all as specified and as directed.
Supply and fix Flame and water proof Rotary switch with cable termination box in LM6 upto 16 Amps single pole ON/OFF complete all as specified and as directed.
Supply and fix MCB 6 to 32 Amps, SP, 240 Volts , 'C' curve braking capacity 10 kA as directed by the Engr-in-Charge.
Supply and fix MCB 6 to 32 Amps, SP, 240 Volts , 'C' curve braking capacity 10 kA including taking down old unserviceable one as directed by the Engr-in-Charge.
Supply and fix MCB 63 Amps, TP, 240 Volts , 'C' curve braking capacity 10 kA including taking down old unserviceable one as directed by the Engr-in-Charge.
Supply and fix MCB 32 Amps, TP, 240 Volts , 'C' curve braking capacity 10 kA including taking down old unserviceable one as directed by the Engr-in-Charge.
Supply and fix MCCB, 250 Amps, 36kA, four pole with thermal and magnetic release including necessary connection including taking down old unserviceable one complete all as specified and as directed Make:- As specified in list of make given in Particular specification here in after.
Material and Labour for repair LT panels/LT feeder piller boxes by carrying out through check all eletrical connections, lugs, busbar voltmeter, ammeter, cableglands, insulator on busbar, and tighting all connections properly with proper size of new nut bolts washer as per the site requirements and insulation of busbar with colour code insuation tapes and preparation of surfaces internal and external of panels/feeder piller boxes by cleaning with dry cloth/removal dust particles by using air blower and scratching the old painted surfaces as directed and painting two coat of synthetic enamel paint over a coat of red oxide prime rand writting existing letters/numbers or as directed and repair the existing PCC basement of the feeder piller box/LT panel as per site requirement or directed and preparation of old decorated/concrete surfaces and applying one coat of cement base paint and testing complete with all electrical connection made all as specified and directed by the Engr-in-Charge.
Supply and fix New generation energy saving and environmental friendly long life LED street light luminaries 45 watt with 32mm dia light grade GI pipe bent to shape of 45º 1.5 m long, made up of pressure die cast aluminium housing with high power LED as lighting source and lens separate driver compartment with IP66 protection including taking down the defective bldg security light complete all as specified and as directed by the Engr-in-Charge.
Supply and fix New generation energy saving and environmental friendly long life LED street light luminaries 90 watt with 32mm dia light grade GI pipe bent to shape of 45º 1.5 m long, made up of pressure die cast aluminium housing with high power LED as lighting source and lens separate driver compartment with IP66 protection including taking down the defective bldg security light complete all as specified and as directed by the Engr-in-Charge.
Supply and fix GI pipe, 40mm bore, light grade for protection & passing of LT cable fixed to pole/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 40mm bore dia all as specified & directed at site including taking out old unserviceable one.
Supply and fix GI pipe, 50mm bore, light grade for protection & passing of LT cable fixed to pole/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 50mm bore dia all as specified & directed at site including taking out old unserviceable one.
Supply and fix GI pipe, 80mm bore, light grade for protection & passing of LT cable fixed to pole/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 80mm bore dia all as specified & directed at site including taking out old unserviceable one.
Supply and fix Centrifugal pump of capacity 15 HP, 2900 RPM of discharging 25 LPS at 22 M head electric motor AC 3 phase 415 Volts 50 Hz including PCC type B2 for basement including taking down old unserviceable one complete all as directed by Engineer-in-Charge. Note:- Pump shall be deposited into MES storeyard.
Supply and fix Rotational moulded water storage tank three layers , 500 Ltrs capacity, ISI marked, cylindrical vertical with close top, hosted and fixed in position with 20mm dia PTMT ball cock with aluminium rod complete including taking down old unserviceable one.
Suppluy and fix Decorative fountain underwater LED light 10 watt 12 Volt water proof as per site requirement or testing complete all as directed by enginner-in-Charge including taking down old unserviceable one.
Taking out unserviceable UG cables of any type and any sizes from trenches etc and removing from the site of work complete all as specified and directed. Note:- (i) Serviceable bricks obtained shall be stacked properly for re-use. (ii) Excavation and earth work shall be measured and paid separately under relevant item of these schedule.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 185 Sqmm 3.5 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 95 Sqmm 3.5 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 35 Sqmm 3.5 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 10 Sqmm 2 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and fix Time Switch FM/1 QUARTZ type QT ( Daily) Voltage 240V, contact ratings 16A, 250 volts AC (resistive) single phase including taking down old unserviceable one.
Supply and fix LED decorative post top lantern, 35/40 Watt capacity for energy efficient conservation upto 50% and with eco friendly lighting system with all accessories and necessary connection including taking down old unserviceable one complete all as specified and as directed. Make:- As specified in list of make given in Particular specification here in after.
Supply and Fix in repairs Land scape Lighting 10 watt ( LED Bollard) of IP 65 rated inverted pyramid type with soft 360º light distribution with necessary PCC base of type B1, 1:2:4, using 20mm graded crushed stone aggregates complete all as specified and as directed.
Supply & Fixing in replacement aviation obstruction light in yellow coloured die cast aluminium alloy housing with built in 75 VA step up transformer, heat resistant, clear thick glass dome mounted on hinged die-cast aluminium ring secured to the body by two studs and wing nuts with neon spiral lamp plugged into spring loaded high tension nylon socket and wired upto the terminal block having degree of protection- IP 54 including dismantling and taking down existing unserviceable/worn out aviation light from RCC over head tank of height not more than 21.0 Mtr complete in all respect as specified and directed. Make:- Cat part No BJAOL 1with neon lamp of Make- BAJAJ or equivalent model as specified in PS
Supply and fix Galvanized iron pipe, 15mm bore, medium grade with all fittings, laid in floor , walls and ceiling complete all as specified & directed.
Supply and fix Storage type water heater ( Geyser) 25 Ltrs capacity, energy efficient SPHP tecnology, vertical type, AC single phase, 230 Volts, 50 Hz including holdfasts and wall fasteners complete all as specified and as directed. Make:- Venus model 25 SD or Havells Puro Plus GHWAPFTIV025 equivalent model as specified in particular specification.
Materials and labour Sub main wiring with 2 runs of single core PVC insulated FRLS unsheathed stranded copper conductor of size 4 Sqmm and one run of PVC insulated FRLS unsheathed multistrand copper conductor of size 4 Sqmm as earth lead drawn in and including PVC casing caping complete all as specified and as directed. Note:- Two runs of 4 Sqmm conductor as main and one run of 4Sqmm conductor for earthing with one run of PVC casing caping shall be measured as one unit.
supply and fix MCB plug and socket SPN enclosure with two pin and earth plug and socket complete with MCB SP, 6-32 Amps, 10kA, 'C' series complete all as specified and as directed.
Materials and Labour Cutting pipeline of size 50mm to 25mm bore and making connection with 20mm bore pipe including GI tee complete all as directed by Engineer-in-Charge.
Materials and Labour Cutting the existing road / path etc for taking of cable including proction pipe of any size and length and making good the disturbed surfaces with PCC type D2( 1:4:8, using 40mm graded crushed stone aggregates) complete all as directed by Engineer-in-Charge.
Supply and fix decorative street light pole, asthetically designed, decorative, hot dipped galvanised mild steel step pole with grey powder coated finish including taking down old unserviceable one complete all as specified and as directed. Make:- Havells Cat Part No. 6MPE or equivalent model from Surya/ CG.
Supply and fixing of junction pole box made of high quality thermoplastic polycarbonate (shock proof ,rust free,corrosion free,acid and chemical resistant,fire retardant, having high impact strength, of IK 9, made of halogen and silica free recyclable material IP66/67 degree of protection UV resistant, having high graded internally embedded gasket made of poly urethane should withstand glow wire test at 960 c centigrade should be flame retradant and self extingushing with switch gear assemblies as per IEC-439-1 the junction box should have 4 power terminal of 25 Sqmm and earth terminal along witha SP MCB of 6 Amp fitted in it the dimension of box shall be 205x255x112in mm (LxHxD) make hensel KF 2500 G make of MCB L&T. and fixing to tubular /PCC pole using MS flat of size 25x3mm with suitable nuts and bolds after taking down old unserviceable one. Make:- Hensel KF 2500 G or equivalent model of make:- RMC/ Universal
NUPUR CONSTRUCTION
K.P Construction Co
CHOWDHURY SMALL INDUSTRIES
AUTO ELECTRICALS
DIPAK ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .