Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance NOT AVAILABLE | Admitted-Finance |
| 2 | Admitted-Finance HARIYANA BHAWAN NEAR MAA SHARADA MANDIR CHOWK RAM NAGAR COLONY BOKARO JHARKHAND 827013 | BOKARO | JHARKHAND | 827013 | Admitted-Finance |
| 3 | Admitted-Finance 149 BINDA PUR D K MOHAN GARDEN UTTAM NAGAR JANAK PURI C 1 WEST DELHI DELHI 110059 UDYAM DL 10 0026593 | WEST DELHI | DELHI | 110059 | Admitted-Finance |
| 4 | Admitted-Finance B 157 MANSAROVAR GARDEN NEW DELHI 110015 | WEST | DELHI | 110015 | Admitted-Finance |
| 5 | Admitted-Finance 15 CANAL ROAD ROORKEE ROORKEE HARIDWAR UTTARAKHAND 247667 | HARIDWAR | UTTARAKHAND | 247667 | Admitted-Finance |
Tender Value
₹65.2 L
EMD Value
₹1.3 L
Closing Date
31 Jul 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
PRINCIPAL, RAM LAL ANAND COLLEGE
PRINCIPAL, RAM LAL ANAND COLLEGE
E-TENDER FOR CONSTRUCTION OF A HALL FOR COMPUTER LAB AT RAM LAL ANAND COLLEGE, NEW DELHI.
2023_DU_762573_1
RLAC/2023/441
Open Tender
Miscellaneous Works
Item Rate
180 days
As Per Tender Documents
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
PRINCIPAL, RAM LAL ANAND COLLEGE
₹1.3 L
Yes
8 Aug 2023
19 Jul 2023
1 Aug 2023
19 Jul 2023
31 Jul 2023
19 Jul 2023
Amount
NOTE: ITEMS MENTIONED AS 0 (ZERO) QUANTITY ARE RATE ONLY ITEMS. PLEASE QUOTE THE RATES FOR THOSE ITEMS. CIVIL WORKS
Demolishing mud phaska/Brick Coba/ Existing Water proofing with floor finish etc. complete in terracing and disposal of material within 50 metres lead.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Dismantling stone and tile work in floors, roof and walls laid in cement mortar including removal of cement mortar and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. For all thickness of stone and tiles .
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. Including plaster/wall tile/wall cladding In cement mortar
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 25 mm average thickness
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). FOR RCC CILL ON EXISTING BRICKWALL + RCC BEAM AND LINTEL
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete all Levels. Thermo-Mechanically Treated bars. (Only TATA Or SAIL)
Centering and shuttering including strutting, propping etc. and removal of form for all works at all levels: Foundations, footings, bases of columns, Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. Suspended floors, roofs, landings, balconies and access platform , Lintels, beams, plinth beams, girders, bressumers and cantilevers, Columns, Pillars, Piers, Abutments, Posts and Struts, Stairs, (excluding landings) except spiral-staircases, Weather shade, Chajjas, corbels etc.,including Edges of slab and breaks in floor & wall
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-Incharge complete in all respect. SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer.
RE-BAR WORK : Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 300mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of Hilty HIT-RE 500 V3 make all complete as per direction of Engineer-In-Charge. a)10mm dia.
RE-BAR WORK : Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 300mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of Hilty HIT-RE 500 V3 make all complete as per direction of Engineer-In-Charge. a) 12mm dia.
RE-BAR WORK : Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 300mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of Hilty HIT-RE 500 V3 make all complete as per direction of Engineer-In-Charge. a)16mm dia.
RE-BAR WORK : Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 300mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of Hilty HIT-RE 500 V3 make all complete as per direction of Engineer-In-Charge. a) 20mm dia
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : i) Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener (Hilti/Fischer make) of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 120 mm
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Providing and fixing for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Only Glazing and paneling to be paid for separately) For fixed portion i)Anodised OR Powder coated aluminium (minimum thickness of powder coating 50 micron) for 3MM thick PATAM DOOR FRAMES AND PATAM WINDOW FRAMES )
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) i) Anodised OR Powder coated aluminium (minimum thickness of powder coating 50 micron)
Supply of Hollow metal fire rated doors as per IS 3614 part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI for maximum rating of 2hrs tested . Individual Test certificates should also be available for glass used in vision lites confirming the required fire ratings /panels being a part of the fire door assembly. Doors should be finished in Thermosetting Powder Coating desired RAL Shades.Door frame shall be Single rebate profile of minimum size 100mm X 57 mm made out of 1.20mm minimum thick galvanized steel sheet. 100x57 Frames shall be Butt jointed and field assembled with self bolted. The frames should be finished with Thermosetting Powder Coating in desired RAL Shade. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Door leaf shall be minimum 46mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 0.8 mm minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be Honeycomb treated with Viper FRS 881 LH. All doors NSD 12046 shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be 5 mm thick keralite glass of size 200*320 mm of saint gobain make Clear Door size: 1: (1500mm X 2400mm) Double Leaf
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands finished with 1mm thick Laminate on both faces of shutter : (Flush door only of Duro/Green/Century/Virgo make and laminate only of Merino, Sundek, Century, Duro make) 35 mm thick including ISI marked 3 no.s 4 inch long Heavy Duty Stainless Steel butt hinges for each single shutter with necessary SS screws complete.
Extra for providing melamine polish finished C.P. teakwood lipping size 35mmx 12 mm size on all four edges of flush door shutters (over all area of door shutter to be measured).
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square
Providing and fixing HILTI HRD-UGT 14 Fastner for fixing the Aluminium Frame to the Masonary Walls ( 3 each on both side jambs and Two on the top).
Providing and fixing bright finished heavy duty SS tower bolts (barrel type) with necessary SS screws etc. complete (Only Dorma/Dorset/Hafle/Hettich Make)
Providing and fixing bright Golden Locks 8" LONDON-R Brass Door Handle & Lock in SS finish complete:
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. (Only of Godrej/Hettich/Dorset/Dorma)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the manufacturers specifications/architectural drawings /directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item): With Toughened Glass of 6mm thickness
Filling the gap in between aluminium frame & adjacent RCC/ Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
Structural steel work riveted, bolted or welded in built up sections, tubular sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. CONTRACTORS SHALL HAVE THEIR COMPLETE ARRANGEMENTS FOR HEAVY EQUIPMENT LIKE CRANE, GANTRY, PULLY HOIST ETC. TO LIFT HEAVY STRUCTURAL MEMBERS FOR WHICH NOTHING EXTRA SHALL BE PAYABLE. CONTRACTORS NEEDS TO SUBMIT COMPLETE METHODOLOGY FOR ERECTING OF STRUCTURAL MEMBERS AND LAYING OF SHEETING AND ANY DAMAGE TO EXISTING STRUCTURE SHALL BE MADE GOOD BY CONTRACTOR WITHOUT ANY EXTRA COST TO COLLEGE. The contractor shall submit a Shop drawing of the Computer Lab Structure along with a Structure Stability Certificate for the Computer lab structure issued by a registered structure engineer along with a copy of the registration certificate of the structure engineer
FALSE CEILING COMPLETE AS PER DSR 2021 ITEM NO. 12.45.3 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) .........including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge Including the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board
2' x 2' GRID FALSE CEILING COMPLETE AS PER DSR 2021 ITEM NO. 12.52.4 Providing and fixing tiled false ceiling of specified materials of size 2'x2' in true horizontal level, suspended on inter lockingmetal grid of hot dipped galvanized steel sections............12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS:2095 part I, of size 2'x2', having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. Heavy Duty T GRID OF - India Gysum 12mm thick high NRC Ceiling Tile of Armstrong , India Gypsum or Gyproc Make
SS 304 Friction Stay in existing aluminium windows: Providing Fixing a pair of 400 mm stainless steel 304 GRADE friction stays of EBCO HILOAD make in existing aluminium windows Including removal of old friction stays.
Providing and Installing 83 mm / 100MM thick PUF insulated Sandwich Walls / Roof Panel with 0.5m thick PPGi sheet on both sides for ceiling. Roof panel shall be of JINDAL KINGSPAN or Llyod PU Panel System or Metecno make only. Contractor will submit the PUF Panel Sample , Shop Drawing and Color Catalogue for approval from the college authorities before procurement of materials
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Flashings/ Aprons.( Upto 600 mm)
Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gm/m²
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade (Basic cost Rs. 110 per sqft) Area of slab upto 0.50 sqm
Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc.,complete. (Kajaria, Orient, Somani, Asian Make Only). Basic cost of tile before tax Rs. 70/- per Sq. Ft. Size of Tile 1200 x 600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, dado, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. (Kajaria, Orient, Somani, Asian Make Only). Basic cost of tile before tax Rs. 70/- per Sq. Ft. Size of Tile 1200 x 600 mm
12 mm cement plaster with 6mm groove at all RCC & Brick work Joints. (Junctions of all RCC and brick shall be provided with chicken wire mesh of 150 mm width on either side of the junction before plastering) 1:3:3 (1 cement: 3course sand: 3 fine sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand) with 6mm groove at RCC & Brick work Joints. (Junctions of all RCC and brick shall be provided with chicken wire mesh of 150 mm width on either side of the junction before plastering)
External painting works: External painting works at all heights and levels as per procedure mentioned including 1) Surface preparation (scrapping, sanding, cleaning) 2) A liberal coat of Wall Primer as per manufacturers specification 3) Painting 2 or more coats of Exterior Weather Proof Paint in various colors (Asian/ ICI /Shalimar/ Berger/ Nerolac) 4) Horizontal surfaces like the tops of chajjas and parapets must be given an additional coat for greater protection Contractor’s scope includes all materials, tools & plants, paint brushes & rollers of approved makes, ropes, lifts, ladders, safety equipment’s, scaffolding and all other equipment’s as may be required to complete the works successfully. (The rates include all labour, materials and items of work required to complete the work successfully up to the satisfaction of the owner)
Internal painting works: Internal painting works at all heights and levels as per procedure mentioned including 1) Surface preparation (scrapping, sanding, cleaning) 2) One coat of Wall Primer as per manufacturers specification 3) Coat of White cement based putty (JK/BIRLA) 4) One liberal coat of wall primer over wall putty 5) Painting 2 or more coats of Premium acrylic emulsion of interior grade, having VOC content less than 50 grams/ litre in various colors (Asian/ ICI /Shalimar/ Berger/ Nerolac) Contractor’s scope includes all materials, tools & plants, paint brushes & rollers of approved makes, ropes, lifts, ladders, safety equipment’s, scaffolding and all other equipment’s as may be required to complete the works successfully. (The rates include all labour, materials and items of work required to complete the work successfully up to the satisfaction of the owner)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
DOUBLE SCAFFOLDING COMPLETE AS PER DSR 2021 ITEM NO. 24.2 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height.......... The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge . The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
SCAFFOLDING NET COMPLETE AS PER DSR 2021 ITEM NO. 26.81 Providing and fixing Scaffolding net of required width made of high density Polyethylene UV …......The Scaffolding net shall be the property of the contractor on completion of the work
TEMPORARY BARRICADING COMPLETE AS PER DSR 2021 ITEM NO. 16.81 Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/bracings covered with 1.63mm thick MS sheet. ..........Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer?in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work)
FURNITURE WORKS
Wiring for the light points with 1.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires of approved make in concealed or surface mounted 25 mm dia 16 gauge MS Conduit including providing and fixing of 6 amps single pole modular switch of approved quality colour make & design in 1.6 mm thick GI box and earthing of fixtures and the outlet box with 1.5 sq.mm PVC insulated copper conductor stranded flexible "FRLS" wire. (including circuit wiring from DB to switch Board) Primary point as above.
Wiring for the light points with 1.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires of approved make in concealed or surface mounted 25 mm dia 16 gauge MS Conduit including providing and fixing of 6 amps single pole modular switch of approved quality colour make & design in 1.6 mm thick GI box and earthing of fixtures and the outlet box with 1.5 sq.mm PVC insulated copper conductor stranded flexible "FRLS" wire. (including circuit wiring from DB to switch Board) Secondary point (Controllling switch and GI box included in item no. 52)
Wiring for ceiling fan point with 1.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible "FRLS" wires in concealed or surface mounted 25 mm dia 16 gauge MS conduits, including providing fan hook box, 6 amps switch and 300 watts electronic step type fan regulator of approved make in GI box and earthing the fan and outlet box with 1.5 sq. mm. PVC insulated copper conductor stranded flexible FRLS wire.(including circuit wiring from DB to switch Board).
Wiring for 250 volts single phase and neutral 16 amps modular switch socket outlet with universal pins with 3 x 4 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible "FRLS" wire in concealed or surface mounted 25 mm dia 16 gauge MS conduit / existing raceway including providing and fixing of 16 amps 3 pin modular switched sockets of approved make and design in 1.6 mm thick GI box with grid plates and earthing the third pin of each socket outlet with 4 Sq mm PVC insulated copper conductor stranded flexible "FRLS" wire. (including circuit wiring from DB to switch Board) Primary point for 16 amps switched socket outlet
Wiring for 250 volts single phase and neutral 16 amps modular switch socket outlet with universal pins with 3 x 4 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible "FRLS" wire in concealed or surface mounted 25 mm dia 16 gauge MS conduit / existing raceway including providing and fixing of 16 amps 3 pin modular switched sockets of approved make and design in 1.6 mm thick GI box with grid plates and earthing the third pin of each socket outlet with 4 Sq mm PVC insulated copper conductor stranded flexible "FRLS" wire. (including circuit wiring from DB to switch Board) Secondary point looped with primary point.
Wiring for 250 volts single phase and neutral 6 amps modular switch socket outlet with universal pins with 3x2.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible "FRLS" wire in concealed or surface mounted 25 mm dia 16 gauge MS conduit / existing raceway including providing and fixing of 6/16 amps 3 pin modular switched sockets of approved make and design in 1.6 mm thick GI box with grid plates and earthing the third pin of each socket outlet with 2.5 Sq mm PVC insulated copper conductor stranded flexible "FRLS" wire. Primary point for 6 amps switched socket outlet
Wiring for 250 volts single phase and neutral 6 amps modular switch socket outlet with universal pins with 3x2.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible "FRLS" wire in concealed or surface mounted 25 mm dia 16 gauge MS conduit / existing raceway including providing and fixing of 6/16 amps 3 pin modular switched sockets of approved make and design in 1.6 mm thick GI box with grid plates and earthing the third pin of each socket outlet with 2.5 Sq mm PVC insulated copper conductor stranded flexible "FRLS" wire. Secondary point looped with primary point
Wiring for 250 volts single phase and neutral 16 amps polycarbonate industrial 3 pin (IP 65/66) socket outlet with 16 amps double pole MCB in a poly carbonate enclosure of approved size and design with 3x4 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible "FRLS" wires in concealed or surface mounted 25 mm dia 16 gauge MS Conduit, including providing and fixing of 16 amps socket and DP MCB (IP 65/66) in poly carbonate enclosure and earthing of third pin of the socket with 4 sq.mm PVC insulated copper conductor stranded flexible FRLS wire.
Wiring for Exhaust fan point with 1.5 sq. mm. insulated copper conductor 1100 volts grade stranded flexible "FRLS" wires of approved make in concealed or surface mounted 25 mm dia 16 guage MS Conduit including providing and fixing of 6 amps flush mounted switch at the normal switch level in 2 mm thick GI box and 6 amps 3 pin flush mounted socket near exhaust fan and earthing of exhaust fan through the third pin of the socket outlet and GI box with 1.5 sq. mm. PVC insulated copper conductor flexible "FRLS " wire.
Providing and fixing in position the following 2mm thick FRLS PVC rigid conduits concealed or exposed as called for including all accessories i.e. bends, junction boxes, with cover plates of approved make and design. 20 mm dia PVC conduit
Providing and fixing in position the following 2mm thick FRLS PVC rigid conduits concealed or exposed as called for including all accessories i.e. bends, junction boxes, with cover plates of approved make and design. 25 mm dia PVC conduit
Supplying of following 1100 volt grade XLPE insulated PVC sheathed copper conductor armoured cable as per specification. 4 core 6 sq. mm
Supplying of following 1100 volt grade XLPE insulated PVC sheathed copper conductor armoured cable as per specification. 3 core 6 sq. mm
Supply, installation, testing and commissioning of the following cubicle type 1.6 mm thick CRCA sheet steel enclosed and partitions to segregate phases recessed in wall or surface mounted final distribution boards of the following description. Distribution board shall be powder coated and double door construction and in four tier configuration. 8 way, Double door TPN DB with 12 No 10/16/20/32 amps SP MCB as outgoing and 3 No. 32 amps DP RCCB’s of 100 mA leakage current including 1 No. 16 amps 4 Pole MCB as incomer & separate neutral link for each phase and earth bar.
RACEWAY Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 40 mm depth X 1.6 mm thickness
RACEWAY Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 240 mm width X 40 mm depth X 1.6 mm thickness
RACEWAY Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 40 mm depth X 1.6 mm thickness
CABLE TRAY Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
CABLE TRAY Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 200 mm width X 50 mm depth X 1.6 mm thickness
CABLE TRAY Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying, fixing, testing and commissioning of 8 SWG GI wire including all necessary fixing accessories and effecting connections..
Chemical Earthing with 3mtr. long 250 Microne Copper bonded UL listed Rod including accessories and providing masonary enclosure with cover plate having locking arrangement and 50Kg. Chemical etc as required.
Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required.
LIGHTING FIXTURES Supply, installation, testing and commissioing of the following lighting fixtures and fans with all fixing accessories etc. as required. Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supply, installation, testing and commissioing of Propeller fan upto 300 mm sweep of approved make complete with louvars and all accessories as required.
Supply and fix wall mounting Fluorescent tube light fitting, 1x 28w, 230V Energy efficient T5, Box type, epoxy powder coated CRCA sheet housing with reflector cover channel, with electronic ballasts, bipin holders, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.(make bajaj- cat no. 160483) or equivalent model in philips adn CG
Supply & Fixing of 36 watt 600mmx600mm recess/surface made of Steel sheet body with power coating of required colour complete as required. (Philips/ Osram/ Wipro / Havells VENUSNEOHE2X2PLR18-42WLED830MOD)
SITC of Recessed mounted 15 watt LED down lighter made up of high pressure die cast aluminium housing complete as required. (Equivalent to Havells INTEGRANEODLR12WLED840S)
Sansun Contractors Pvt.Ltd
M/S KUBER BUILD TECH
NCI Global Infratech
S KUMAR AND COMPANY
Baljeet Builders and Interior Decorators
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .