Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹41.9 L+₹4.0 L (10.6%)Rejected-Finance | L2 | Rejected-Finance Higher | |
| 3 | L3₹42.5 L+₹4.6 L (12.2%)Rejected-Finance | L3 | Rejected-Finance Higher | |
| 4 | L4₹43.4 L+₹5.5 L (14.4%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Higher |
Tender Value
₹45,000
EMD Value
₹90,000
Closing Date
30 Nov 2021, 6:00 pmClosed
GE NAMS
GE NAMS KHASA CANTT AMRITSAR
IMPROVEMENT TO LT DISTRIBUTION SYSTEM, LT PANELS, LT OH LINES AND UG CABLE AT GE NAMS
2021_MES_481551_2
GE NAMS - 47 / 21 - 22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NAMS CANTT
Class D
Category b i
6 documents required · 6 mandatory
₹500
Yes
GE NAMS
₹90,000
Yes
28 Dec 2021
12 Nov 2021
1 Dec 2021
12 Nov 2021
30 Nov 2021
16 Nov 2021
Amount
Supply, Install, Testing and Commissioning in replacement of factory made outdoor type dust and vermin proof(IP 54 protection)feeder Pillar LT Panel board cubicle double door hinged type of suitable size 415V AC, 50Hz, fabricated of GP/CRCA sheet 3.15mm(10 SWG) thick machine pressed and angle iron frame 50mm X 50mm X 6mm grouted in PCC 1:2:4 type BI (20mm grade stone aggregated) powder coated in Seven Tank process inside and outside complete including 4 Pole aluminum Bus Bar of suitable size mounted on porcelain insulator ,concealed hinged door with 3Positioning door locking arrangement and enclosed in chamber made out of 2mm sheet thick GP/ CRCA sheet machine pressed and connection from incoming and outgoing electric cable with suitable size thimbles/lugs cable gland with open able shutters on both side and comprising of following (i)MCCB 250 Amps 36KA 4pole with microprocessor release adjustable type of as a incomer-01 (ii) MCCB 36 KA 3P, 160Amp -01 (iii) MCCB 36 KA, 3P 100A -02 (iv) Copper Busbar of 400 Amps phase+Nutral with insulated (v) Digital Ammeter and volt meter of suitable size (vi) LED indicator lamp Red/yellow/Blue colour
Supply, Install, Testing and Commissioning in replacement offactory made outdoor type dust and vermin proof(IP 54 protection) feeder Pillar LT Panel board cubicle double door hinged type of suitable size 415V AC, 50Hz, fabricated of GP/CRCA sheet 3.15mm(10 SWG) thick machine pressed and angle iron frame 50mm X 50mm X 6mm grouted in PCC 1:2:4 type BI (20mm grade stone aggregated) powder coated in Seven Tank process inside and outside complete including 4 Pole aluminum Bus Bar of suitable size mounted on porcelain insulator ,concealed hinged door with 3Positioning door locking arrangement and enclosed in chamber made out of 2mm sheet thick GP/ CRCA sheet machine pressed and connection from incoming and outgoing electric cable with suitable size thimbles/lugs cable gland with open able shutters on both side and comprising of following (i) MCCB 500 Amps 4pole,415 Volt with thermal magnetic release (Manual drawout type) as an incomer-01 (ii) MCCB 36 KA 3P 160Amp -03 (iii) MCCB 36 KA 3P 100Amp -03 (iv) Copper Busbar of 750 Amps phase+Nutral with insulated (v) Digital Ammeter and volt meter of suitable size with suitable CT's. (vi) LED indicator lamp Red/yellow/Blue colour
Supply and installation in repairs, commissioning and testing polycarbonate ASTA CPRI approved OEM made main LT Panel. The panel shall be made of modular polycarbonate thermoplastic enclosure including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of ingress protection IP 65 IN accordance with IEC 60529 & Against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. The gasket shall be internally embedded made of polyurethane. The Panels made by aprroved enclosures in MES & they shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1. The ASTA CPRI report with Approved Drawing shall have mention of following tests performed and passed out satisfactorily - Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits.
The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing] and comprising the following :- (i)MCCB 200 Amps 35KA 4pole with microprocessor release adjustable type of as a incomer-01 (ii) MCCB 36 KA, 3P, 100Amp -03 (iii) Copper Busbar of 300 Amps phase+Nutral with insulated (iv) Digital Ammeter and volt meter of suitable size (v) LED indicator lamp Red/yellow/Blue colour
Supply and installation in repairs, commissioning and testing polycarbonate ASTA CPRI approved OEM made main LT Panel. The panel shall be made of modular polycarbonate thermoplastic enclosures including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of ingress protection IP 65 IN accordance with IEC 60529 & Against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. The gasket shall be internally embedded made of polyurethane. The Panels made by aprroved enclosures in MES & they shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1. The ASTA CPRI report with Approved Drawing shall have mention of following tests performed and passed out satisfactorily - Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits.
The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing] and comprising the following: - (i)MCCB 250 Amps 36KA 4pole with microprocessor release adjustable type of as a incomer-01 (ii) MCCB 36 KA,3P, 100Amp -04 (iii) Copper Busbar of 400 Amps phase+Nutral with insulated (iv) Digital Ammeter and volt meter of suitable size (v) LED indicator lamp Red/yellow/Blue colour
Supply and installation in repairs, commissioning and testing polycarbonate ASTA CPRI approved OEM made main LT Panel. The panel shall be made of modular polycarbonate thermoplastic enclosure including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of ingress protection IP 65 IN accordance with IEC 60529 & Against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. The gasket shall be internally embedded made of polyurethane. The Panels made by aprroved enclosures in MES & they shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1. The ASTA CPRI report with Approved Drawing shall have mention of following tests performed and passed out satisfactorily - Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits.
The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing] and comprising the following: - (i) MCCB 400 Amps 4pole,415 Volt with thermal magnetic release (Manual drawout type) as an incomer-01 (ii) MCCB 36 KA 3P 250Amp -02 (iii) MCCB 36 KA 3P 100Amp -02 (01 Spare) (iv) Copper Busbar of 600 Amps phase+Nutral with insulated (v) Digital Ammeter and volt meter of suitable size with suitable CT's. (vi) LED indicator lamp Red/yellow/Blue colour
Supply and installation in repairs, commissioning and testing polycarbonate ASTA CPRI approved OEM made main LT Panel. The panel shall be made of modular polycarbonate thermoplastic enclosures including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of ingress protection IP 65 IN accordance with IEC 60529 & Against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. The gasket shall be internally embedded made of polyurethane. The Panels made by aprroved enclosures in MES & they shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1. The ASTA CPRI report with Approved Drawing shall have mention of following tests performed and passed out satisfactorily - Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits.
The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing] and comprising the following: - (i) MCCB 400 Amps 4pole,415 Volt with thermal magnetic release (Manual drawout type) as an incomer-01 (ii) MCCB 36 KA 3P 250Amp -02 (iii) MCCB 36 KA 3P 160Amp -01 (iv) Copper Busbar of 600 Amps phase+Nutral with insulated (v) Digital Ammeter and volt meter of suitable size with suitable CT's. (vi) LED indicator lamp Red/yellow/Blue colour
Supply and installation in repairs, commissioning and testing polycarbonate ASTA CPRI approved OEM made main LT Panel. The panel shall be made of modular polycarbonate thermoplastic enclosures including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of ingress protection IP 65 IN accordance with IEC 60529 & Against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. The gasket shall be internally embedded made of polyurethane. The Panels made by aprroved enclosures in MES & they shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1. The ASTA CPRI report with Approved Drawing shall have mention of following tests performed and passed out satisfactorily - Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits.
The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing] and comprising the following: - (i) MCCB 400 Amps 4pole,415 Volt with thermal magnetic release (Manual drawout type) as an incomer-01 (ii) MCCB 36 KA 3P 100Amp -06 (iii) Copper Busbar of 600 Amps phase+Nutral with insulated (iv) Digital Ammeter and volt meter of suitable size with suitable CT's. (v) LED indicator lamp Red/yellow/Blue colour
Supply and installation in repairs, commissioning and testing polycarbonate ASTA CPRI approved OEM made main LT Panel. The panel shall be made of modular polycarbonate thermoplastic enclosures including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of ingress protection IP 65 IN accordance with IEC 60529 & Against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. The gasket shall be internally embedded made of polyurethane. The Panels made by aprroved enclosures in MES & they shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1. The ASTA CPRI report with Approved Drawing shall have mention of following tests performed and passed out satisfactorily - Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits.
The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing] and comprising the following: - (i)ACB 630 Amps 4pole,415 Volt with thermal magnetic release (Manual drawout type) as an incomer-01 (ii) MCCB 36 KA 3P 200Amp -02 (iii) MCCB 36 KA 3P 160Amp -02 (iv) MCCB 16 KA, 3P, 100Aamp -01 (v) Copper Busbar of 1000 Amps phase+Nutral with insulated (vi) Digital Ammeter and volt meter of suitable size with suitable CT's. (vii) LED indicator lamp Red/yellow/Blue colour
Supply and installation in repairs, commissioning and testing polycarbonate ASTA CPRI approved OEM made main LT Panel. The panel shall be made of modular polycarbonate thermoplastic enclosures including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of ingress protection IP 65 IN accordance with IEC 60529 & Against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. The gasket shall be internally embedded made of polyurethane. The Panels made by aprroved enclosures in MES & they shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1. The ASTA CPRI report with Approved Drawing shall have mention of following tests performed and passed out satisfactorily - Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits.
The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing] and comprising the following: - (i)ACB 630 Amps 4pole,415 Volt with thermal magnetic release (Manual drawout type) as an incomer-01 (ii) MCCB 36 KA 3P 200Amp -03 (iii) MCCB 36 KA 3P 160Amp -01 (iv) Copper Busbar of 1000 Amps phase+Nutral with insulated (v) Digital Ammeter and volt meter of suitable size (vi) LED indicator lamp Red/yellow/Blue colour
Supply and installation in repairs, commissioning and testing polycarbonate ASTA CPRI approved OEM made main LT Panel. The panel shall be made of modular polycarbonate thermoplastic enclosures including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of ingress protection IP 65 IN accordance with IEC 60529 & Against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. The gasket shall be internally embedded made of polyurethane. The Panels made by aprroved enclosures in MES & they shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1. The ASTA CPRI report with Approved Drawing shall have mention of following tests performed and passed out satisfactorily - Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits.
The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing] and comprising the following: - (i)MCCB 320 Amps 36KA 4pole with microprocessor release adjustable type of as a incomer-01 (ii) MCCB 36 KA 3P 200Amp -01 (iii) MCCB 36 KA 3P 160A -02 (iv) Copper Busbar of 500 Amps phase+Nutral with insulated (v) Digital Ammeter and volt meter of suitable size with suitable CT's (vi) LED indicator lamp Red/yellow/Blue colour
Supply and installation in repairs, commissioning and testing polycarbonate ASTA CPRI approved OEM made main LT Panel. The panel shall be made of modular polycarbonate thermoplastic enclosures including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of ingress protection IP 65 IN accordance with IEC 60529 & Against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. The gasket shall be internally embedded made of polyurethane. The Panels made by aprroved enclosures in MES & they shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1. The ASTA CPRI report with Approved Drawing shall have mention of following tests performed and passed out satisfactorily - Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current,
Effectiveness of Protective Circuits. The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing] and comprising the following: (i)MCCB 500 Amps 36KA 4pole with microprocessor release adjustable type of as a incomer-01 (ii) MCCB 36 KA, 3P, 250 Amp -02 (ii) MCCB 36 KA, 3P, 160 Amp -01 (iii) Copper Busbar of 800 Amps phase + Nutral with insulated (iv) Digital Ammeter and volt meter of suitable size (v) LED indicator lamp Red/yellow/Blue colour
Note for Srl 2 to 12 above (i) The panel Make should be CPRI approved. (ii) Panel should be manufactured by Manufacturer itself (OEM) and Inspection will be done at the factory premises before dispatch along with “HATCH TEST”. (iii) Before Placing the order the panel drawing should be approved by Engr-In-Charge. (iv) Each angel of panel shall be embaded in 20x20x30 cm PCC 1:2:4 type B1 using 20 mm graded stone aggregate and panel shall be of 450 mm high from ground level .
Supply laying & testing in replcementof cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) LT 1100 volt grade with stranded aluminium conductor of size 300 sqmm 3.5 core complete all as specified and directed.
All as per srl item No 13 here in before but of size 240 Sqmm 3.5 core.
All as per srl item No 13 here in before but of size 185 Sqmm 3.5 core.
All as per srl item No 13 here in before but of size 120 Sqmm 3.5 core.
All as per srl item No 13 here in before but of size 95 Sqmm 3.5 core.
All as per srl item No 13 here in before but of size 70 Sqmm 3.5 core.
All as per srl item No 13 here in before but of size 50 Sqmm 3.5 core.
All as per srl item No 13 here in before but of size 35 Sqmm 3.5 core.
All as per srl item No 13 here in before but of size 25 Sqmm 4 core.
All as per srl item No 13 here in before but of size 16 Sqmm 4 core.
All as per srl item No 13 here in before but of size 16 Sqmm 2 core.
Supply, laying & fixing double wall corrugated (DWC) pipes 50mm outer dia and 38mm inner dia made of high density polythyline (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc complete all as specified and directed.
All as per srl item No 24 here in before but of size 90mm outer dia and 76mm inner dia.
All as per srl item No 24 here in before but of size 77mm outer dia and 63mm inner dia.
S&F in repairs cable end joint kit for 1100 volt, out door type joint complete with all jointing material and accessories suitable for 3.5 / 4 Core cable of size 25 sqmm to 50 sq mm all as directed.
S&F in repairs cable end joint kit for 1100 volt, out door type joint complete with all jointing material and accessories suitable for 3.5 / 4 Core cable of size 70 sqmm to 150 sq mm all as directed.
S&F in repairs cable end joint kit for 1100 volt, out door type joint complete with all jointing material and accessories suitable for 3.5 core cable of size 185 sqmm to 300 sq mm all as directed.
Material and Labour in replacement straight through joint Cold shinkable suitable for 50 to 185 sq mm 3.5 core 1100 volts XPLE cable type complete all as specified and directed.
Exacavation for cable loops near the poles LT Panels transformers, cutting the damages/burnt parts of cable and reconnecting its positions complete with thimbles, nut bolts, sleaves all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI strip of size 32 X 6 mm and 40 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009. Note :- All joints either strip to strip of strip to earth plate are fixed with welded joints.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI wire of size 4 mm dia and 15 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009.
M & L in replacement of MCCB Capacity 630 Amp 50 KA 4 pole adjustable thermal megnate release type with preader and aluminium lugs all as fixed in existing LT Panel.
M & L in replacement of MCCB Capacity 500 Amp 36 KA 4 pole adjustable thermal megnate release type with preader and aluminium lugs all as fixed in existing LT Panel.
M & L in replacement of MCCB Capacity 400 Amp 36 KA 4 pole adjustable thermal megnate release type with preader and aluminium lugs all as fixed in existing LT Panel.
M & L in replacement of MCCB Capacity 250 Amp 36 KA 4 pole adjustable thermal megnate release type with preader and aluminium lugs all as fixed in existing LT Panel.
M & L in replacement of MCCB Capacity 160 Amp 36 KA 4 pole adjustable thermal megnate release type with preader and aluminium lugs all as fixed in existing LT Panel.
M & L in replacement of MCCB Capacity 100 Amp, 16 ka, 3 pole adjustable thermal megnate release type with preader and aluminium lugs all as fixed in existing LT Panel.
M & L in replacement of MCCB Capacity 160 Amp, 36 ka, 3 pole adjustable thermal megnate release type with preader and aluminium lugs all as fixed in existing LT Panel.
M & L in replacement of MCCB Capacity 200 Amp, 36ka, 3 pole adjustable thermal megnate release type with preader and aluminium lugs all as fixed in existing LT Panel.
Supply and fix in repairs APFC relay 8 stage with single CT input CSPF-100-08 complete all as specified and directed.
M&L to repair in replacement of shunt capacitor 5.0 KVAR complete all as specified and directed.
M&L to repair in replacement of shunt capacitor 10.0 KVAR complete all as specified and directed.
M&L to repair in replacement of shunt capacitor 20.0 KVAR complete all as specified and directed.
M&L for capacitor duty power contactor, 3 Pole, 240 Volt AC suitable for 50 kvar capacitor complete all as specified and as directed
M&L for capacitor duty power contactor, 3 /4 Pole, 240 Volt AC suitable for 5 - 7.5 kvar capacitor complete all as specified and as directed
M&L for capacitor duty power contactor, 3 /4 Pole, 240 Volt AC suitable for 10 -15 kvar capacitor complete all as specified and as directed
M&L for capacitor duty power contactor, 3 /4 Pole, 240 Volt AC suitable for 20-25 kvar capacitor complete all as specified and as directed
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white , with letters, figures and conventional skull and bones in signal red and fixed with MS Clamps , bolts and nuts of approved size for LT , 20x 15 cm complete all as specified and as directed.
Material & labour for restrainging ACSR conductor HT/LT providing suitable proper sag all as specified and directed.
Supply & fixing of LT stay assembly comprising of 7/3.15mm galvanized MS stay wire of reqd length, fixed to poles with and including of FI clamps made out of FI 40x6mm and nuts bolts washers of suitable size MS stay bow 14mm dia galvanized 40cm long MS galvanised stay rod threaded with nut 16mm dia 21 Cm long with washers MS stay plate galvanized 230x30x6mm incl necessary Excavation and PCC all as specified and directed by Engr-in charge
S&F pin type porcelain white, brown or green insulator including one galvanized mild steel spindle, two galvanised iron washers & one galvanised nut 50mm height,65mm dia for working pressure 1100 volts grade.all as specified and directed by Engr-in charge
S&F porcelain shakle insulator suitable for 440V complete all as specified and as directged.
Material and labour for ACSR conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators weight of conductor shall be measured straight horizontal distance between centre of two adjacent HT/LT poles and calculating weight of conductor of size length by adding 3% extra for sag jointing jumpers etc complete all as specified and directed.
M & L cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint.
Material and labour for preparing old painted surface of panel board by cleaning removing of old paint by scratching with wire brush / sand paper etc and including denting of broken / rusted surface and applied two coat of synthetic surface enamel paint by spray painting outside surface of panel as existing colour of panel all as specified and directed.
Supply and laying GI steel tubing, 80mm bore, light grade with all fittings, laid in trenches / under roads / along pole / wall for protection of Cable / GI wire / GI strip etc complete all as specified and directed.
Supply and spraying anti vegetation chemical liquid of 1 ltrs bottle complete as per direction of Engr in charge .
Excavation trenches not exceeding 1.5m wide & not exceeding 1.5m in depth for and getting out in any of soil.
Returning, filling including spreading, leveling, watering and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of surplus excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as specified and directed. Note :-Punned down thickness of sand shall be considered for measurement)
M & L for sub class "B" brick covering laid dry flat (width equal to be length of the bricks) over sand cushioning along the length of cable complete all as specified and directed.
M & L in replacement of out door type aluminuam bus bar chamber feeder box of cap 300 Amp, 3 phase, 4 wire, 415 Volts of size 90 x 60 x 45 cm made out of 3.15 mm CRCA Sheet duly painted with two coats of synthetic enameld paint over a red oxide primer and fixed and supported with anlge iron grouted in PCC 1:2:4 upto 0.30 mtr high from ground level all as directed by Engr-In-Charge.
M& L for Aluminium Busbar of 400 Amps with insulation (RYB) and making hole for connecting LT Cable complete with measuring size in LT Panel and cut bus bar to the size and fixed in LT Panel including taking out and making cable cable complete all as specified and as directed
Material and labour in replacement for framing of soft wood notice sign board of size 600 mm X 1200 mm duly framed with 40 mm X 20 mm teek wood fixed with hassan cloth dark green/navy blue in colour fixed and stiched on the board properly in corporated with hanging arrangement with 02 nos hooks complete in all respected as specified and directed by Engr-in-charge
Material and labour in replacement portable tripod stand suitable for white board/ notice board of size 5 feet x 3 feet made of prime quality CRCA steel complete all as specified and as directed
Santokh Singh and Associates
M/s MAHAJAN CONSTRUCTION CO.
kailu construction co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .