Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-Finance 00 OPP RASHMI HOSPITAL RAYA ROAD LAXMI NAGAR MATHURA UTTAR PRADESH 281204 | MATHURA | UTTAR PRADESH | 281204 | ₹1.5 Cr | L1 | Accepted-Finance QUALIFIED FINANCIAL SUMMARY |
| 2 | L2₹1.6 Cr+₹7.8 L (5.27%)Accepted-Finance CHANDAN NAGAR OPP IOCL PERTROL PUMP RAMPUR ROAD BAREILLY UP 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | ₹1.6 Cr+₹7.8 L (5.27%) | L2 | Accepted-Finance QUALIFIED FINANCIAL SUMMARY |
| 3 | L3₹1.6 Cr+₹13.2 L (8.97%)Accepted-Finance | ₹1.6 Cr+₹13.2 L (8.97%) | L3 | Accepted-Finance QUALIFIED FINANCIAL SUMMARY |
Tender Value
₹98 L
EMD Value
₹98,000
Closing Date
17 Jul 2023, 12:00 pmClosed
SE EDC
SHAHJAHANPUR
EXECUTION OF VARIOUS WORK FOR SHIFTING OF LINE FROM NAWADA MODE TO TILHAR AND FATENGANJ TO DATAGANJ VIA NAWADA MODE UNDER THE HEAD FULL DEPOSIT IN EDD TILHAR UNDER EDC SHAHJAHANPUR
2023_MVVNL_813303_3
10(W)/EDCS/2023-24
Open Tender
Miscellaneous Works
Item Rate
30 days
SHAHJAHANPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
SE EDC
₹98,000
Yes
25 Jul 2023
8 Jul 2023
17 Jul 2023
8 Jul 2023
17 Jul 2023
8 Jul 2023
Amount
Carriage of following line material for 11KV line from Store Centre to the site of work including measuring, weighing, loading, unloading at both ends and proper stacking at safe site
STP 11Mtr. long
PCC pole 8.5Mtr. Long
Top channel (125X65X2240MM)
Dropper channel (100X50X2240MM)
MS Angle 75X75X6mmX2028MM with nut
MS T-Off channel (125X65X1300MM)
Cross Bracing MS Angle
11 KV Disc insulators T & C type
11 KV disc fitting T & C type
11 KV disc insulator B&S type
11 KV disc fitting B &S type
11 KV Pin insulator polymer type
11 KV cross arm V type
11 KV F clamp
Transformer 11/0.4KV 25 KVA
Transformer 11/0.4 KV 100 KVA
Stay set complete
MS Earthing rod
ACSR weasel conductor
GI wire 8 SWG for guarding
33 KV XLPE cable 3 X 300 sqmm
33 KV XLPE jointing kit O/D 3X300 sqmm
11 KV XLPE cable 3X185sqmm
11 KV XLPE Jointing Kit O/D type 3X185 sqmm
AB cable (3X50+1X35+1x16)sqmm
AB cable (3X95+1X70+1X16)sqmm
AB cable (3X120+1X95+1X16)sqmm
Erection of the following supports including cutting, making holes, fixing of all types of accessories digging of pits complete in all respect, as per RESSPO drawing.
Single support of PCC pole 8.5 mtr long.
Double pole structure on S.T. Pole 11mtr long complete with bracing.
Double pole structure on PCC. Pole 8.5mtr long complete with bracing.
Installation of transformer of 11/0.4 KV 25 KVA
Installation of transformer of 11/0.4 KV 100 KVA
Concreting of supports at the time of erection of pole (PCC/STP 8.50 MTR/11.00 MTR) in 1:4:8 concrete ratio from bottom of pole to ground level and plinthing of supports upto 300mm above ground level by using cement, sand & coarse aggregate in ratio 1:4:8 as per RESSPO drawing with watering/curing properly upto proper setting of plinthing. All matrial would be provided by the contractor at his own cost.
Erection of stay set with stay wire, stay clamp & stay insulator including with grouting of stay set by concrete of ratio 1:4:8 as per RESSPO norms before back fitting of the pits including binding, climbing, clamping, tightening and nozzeling of stay wire in all respect as per RESSPO norms. All clamps, nuts, bolts, stay insulator, cement. brick, ballast, sand etc would be provided by the contractor at his own cost.
Laying and sagging of 3 phase ACSR weasel conductor from single pole/double pole 11 KV feeder line including jumpering, hoisting, fixing of all type of insulators, binding, jointing and its clamping etc in all respect.
Stringing and sagging of LT ABC bunch conductor of size (3X50+1X35+1x16)sqmm with proper fixing of connector (All type of clamp like suspension,I hook,dead end, connector provided by contractor at his own cost)
Stringing and sagging of LT ABC bunch conductor of size (3X95+1X70+1X16)sqmm with proper fixing of connector( All type of clamp provided by contractor at his own cost)
Stringing and sagging of LT ABC bunch conductor of size (3X120+1X95+1X16)sqmm with proper fixing of connector( All type of clamp provided by contractor)
Earthing of each pole of the line is to be done by inserting the MS earth rod into soil by hammering and properly fastning with GI wire to each support by nut & bolt. Earthing rod must be 0.15Mtr.above from the plinth of the support. All type nut & bolt would be given by the contractor.
Guarding of HT/LT/Telephone Line/ Road/River Crossing etc. by providing G.S Earth wire 7/16 SWG/GI wire No. 8/10 and making net with difference of 1.00 Mtr. Completely including fixing of channel/angle etc. with proper locking at each support as per RESSPO norms. All type nut &bolts, would be given by the contractor at his own cost.
Laying and dressing of 33 KV XLPE 3X300sqmm XLPE cable from D/P or Single pole by excavation of trench in the ground of size 450mm wide, 1000 mm deep providing 150 mm fine sand cushion below the cable. The cable shall be duly protected by bricks, sand and stone slab and refilling and ramping of the left out soil. Spare cable shall be left and buried in the trench in the shape of ring at both ends. (All decentralised material to be provided by contractor)
33 KV Cable laying by drill method in single circuit
33 KV Cable laying by drill method in HDPE Pipe (6" DIA, PE100/PM 160) single circuit (HDPE pipe provided by firm)
Hoisting of 33 KV 3X300 Sq. mm. XLPE cable on double pole in HDPE Pipe (6" DIA, PE100/PM 160) including its jumpering complete along with cost of HDPE Pipe (6" DIA, PE100/PM 160) 3 M long, clamps, nuts and bolts. (HDPE pipe provided by contractor)
Fixing of 33 KV 3x300sqmm O/D
Laying and dressing of 11 KV XLPE 3X185sqmm XLPE cable from D/P or Single pole by excavation of trench in the ground of size 450mm wide, 1000 mm deep providing 150 mm fine sand cushion below the cable. The cable shall be duly protected by bricks, sand and stone slab and refilling and rampinf of the left out soil. Spare cable shall be left and buried in the trench in the shape of ring at both ends. (All decentralised material to be provided by contractor at his own cost)
11 KV XLPE Cable 3X185 SQMM laying by drill method in HDPE Pipe (6" DIA, PE100/PM 160) single circuit (HDPE pipe provided by contractor at his own cost)
Hoisting of 11 KV 3X185 Sq. mm. XLPE cable on double pole in HDPE Pipe (6" DIA, PE100/PM 160) including its jumpering complete along with cost of HDPE Pipe (6" DIA, PE100/PM 160) 3 M long, clamps, nuts and bolts.
Fixing of 11 KV 3x185sqmm O/D
Fixing of 11 KV Cable Marker on the route as per indian standards. The markers shall be as per indian standards with impressed character; (all material would be provided be contractor)
Fixing of danger board and G.I barbed wire on each pole including proper clamping. (All material would be provided by contractor).
Painting of ST POLES of the 33KV/ 11 KV line with one coat of red oxide primer and two coats of aluminium white paint of ISI mark and top danger portion of each support must be painted by providing two coat of Post Office Red Paint (1.5mtr upper portion of support.) Paint and material would be given by contractor to complete of work at his own cost.
Clearing of the line route by cutting of tree branches during erection of line and also upto the time of energisation completely as per direction of site incharge.
Back cartage of old material from different sites to store center, Baibagh, Shahjanpur including loading and unloading. Complete job as per requirement and instruction of JE/SDO concerned.
PART B FATEHGANJ TO DATAGANJ SECTION
Carriage of following line material for 11KV line from Store Centre to the site of work including measuring, weighing, loading, unloading at both ends and proper stacking at safe site
STP 11Mtr. long
PCC pole 8.5Mtr. Long
Top channel (125X65X2240MM)
Dropper channel (100X50X2240MM)
MS Angle 75X75X6mmX2028MM with nut
MS T-Off channel (125X65X1300MM)
Cross Bracing MS Angle
11 KV Disc insulators T & C type
11 KV disc fitting T & C type
11 KV Pin insulator polymer type
11 KV cross arm V type
11 KV F clamp
Transformer 11/0.4KV 25 KVA
Stay set complete
MS Earthing rod
ACSR weasel conductor
GI wire 8 SWG for guarding
11 KV XLPE cable 3X185sqmm
11 KV XLPE Jointing Kit O/D type 3X185 sqmm
AB cable (3X50+1X35+1x16)sqmm
Erection of the following supports including cutting, making holes, fixing of all types of accessories digging of pits complete in all respect, as per RESSPO drawing.
Single support of PCC pole 8.5 mtr long.
Single support of ST pole 11.0 mtr long.
Double pole structure on S.T. Pole 11mtr long complete with bracing.
Double pole structure on PCC. Pole 8.5mtr long complete with bracing.
Installation of transformer of 11/0.4 KV 25 KVA
Concreting of supports at the time of erection of pole (PCC/STP 8.50 MTR/11.00 MTR) in 1:4:8 concrete ratio from bottom of pole to ground level and plinthing of supports upto 300mm above ground level by using cement, sand & coarse aggregate in ratio 1:4:8 as per RESSPO drawing with watering/curing properly upto proper setting of plinthing. All matrial would be provided by the contractor at his own cost.
Erection of stay set with stay wire, stay clamp & stay insulator including with grouting of stay set by concrete of ratio 1:4:8 as per RESSPO norms before back fitting of the pits including binding, climbing, clamping, tightening and nozzeling of stay wire in all respect as per RESSPO norms. All clamps, nuts, bolts, stay insulator, cement. brick, ballast, sand etc would be provided by the contractor at his own cost.
Laying and sagging of 3 phase ACSR weasel conductor from single pole/double pole 11 KV feeder line including jumpering, hoisting, fixing of all type of insulators, binding, jointing and its clamping etc in all respect.
Stringing and sagging of LT ABC bunch conductor of size (3X50+1X35+1x16)sqmm with proper fixing of connector (All type of clamp like suspension,I hook,dead end, connector provided by contractor at his own cost)
Earthing of each pole of the line is to be done by inserting the MS earth rod into soil by hammering and properly fastning with GI wire to each support by nut & bolt. Earthing rod must be 0.15Mtr.above from the plinth of the support. All type nut & bolt would be given by the contractor.
Laying and dressing of 11 KV XLPE 3X185sqmm XLPE cable from D/P or Single pole by excavation of trench in the ground of size 450mm wide, 1000 mm deep providing 150 mm fine sand cushion below the cable. The cable shall be duly protected by bricks, sand and stone slab and refilling and rampinf of the left out soil. Spare cable shall be left and buried in the trench in the shape of ring at both ends. (All decentralised material to be provided by contractor at his own cost)
11 KV XLPE Cable 3X185 SQMM laying by drill method in HDPE Pipe (6" DIA, PE100/PM 160) single circuit (HDPE pipe provided by contractor at his own cost)
Hoisting of 11 KV 3X185 Sq. mm. XLPE cable on double pole in HDPE Pipe (6" DIA, PE100/PM 160) including its jumpering complete along with cost of HDPE Pipe (6" DIA, PE100/PM 160) 3 M long, clamps, nuts and bolts.
Fixing of 11 KV 3x185sqmm O/D
Fixing of 11 KV Cable Marker on the route as per indian standards. The markers shall be as per indian standards with impressed character; (all material would be provided be contractor)
Fixing of danger board and G.I barbed wire on each pole including proper clamping. (All material would be provided by contractor).
Painting of ST POLES of the 33KV/ 11 KV line with one coat of red oxide primer and two coats of aluminium white paint of ISI mark and top danger portion of each support must be painted by providing two coat of Post Office Red Paint (1.5mtr upper portion of support.) Paint and material would be given by contractor to complete of work at his own cost.
Clearing of the line route by cutting of tree branches during erection of line and also upto the time of energisation completely as per direction of site incharge.
Back cartage of old material from different sites to store center, Baibagh, Shahjanpur including loading and unloading. Complete job as per requirement and instruction of JE/SDO concerned.
BHARAT ELECTRICAL TRADERS
NATIONAL CONTRACTOR & GENERAL ORDER SUPPLIER
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .