| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAccepted-AOC | ₹2.8 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹2.8 Cr+₹5.4 L (1.93%)Rejected-Finance UNIT 4A 4TH FLOOR MAYUR GARDEN OPP OF RAJIV BHAWAN ABC BUS STOP BHANGAGARH G S ROAD GUWAHATI KAMRUP M 781005 | KAMRUP METRO | ASSAM | 781005 | ₹2.8 Cr+₹5.4 L (1.93%) | L2 | Rejected-Finance L2 BIDDER |
| 3 | L3₹3.1 Cr+₹32.0 L (11.5%)Rejected-Finance 184 NEAR GOODWAY TAILORS PRITHVIPURA RASAL ROAD BRIDGE JODHPUR RAJASTHAN 342006 | JODHPUR | RAJASTHAN | 342006 | ₹3.1 Cr+₹32.0 L (11.5%) | L3 | Rejected-Finance L3 BIDDER |
| 4 | L4₹4.4 Cr+₹1.7 Cr (59.7%)Rejected-Finance GODREJ GENESIS BUILDING UNIT NO 609 PLOT NO XI 6TH FLOOR BLOCK EP GP SECTOR V SALT LAKE KOLKATA 700091 | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹4.4 Cr+₹1.7 Cr (59.7%) | L4 | Rejected-Finance L4 BIDDER |
Tender Value
₹2.8 Cr
EMD Value
₹5.7 L
Closing Date
14 Nov 2022, 12:00 pmClosed
CGM PP and D
1st floor,Bijulee Bhawan, Guwahati-1
Turnkey Construction of 01 No. of 132kV Railway Traction Bay at 220kV Namrup GSS, AEGCL including Supply of Bay Equipment and line bay materials and associated works etc
2022_AEGCL_27364_1
AEGCL_Namrup
Open Tender
Electrical Works
Turn-key
210 days
Namrup
Please refer Tender documents.
8 documents required · 8 mandatory
₹5,000
₹5.7 L
7 Jan 2023
14 Oct 2022
15 Nov 2022
15 Oct 2022
14 Nov 2022
22 Oct 2022
Amount
Circuit Breakers with mounting structures and terminal connectors etc.as applicable as per specification
132 kV Gang operated outdoor SF6 Breakers
SIEMENS made Control & Relay Panel with Automation (Simplex Type) complete with BCU, ethernet switch and all accessories as required for SAS integration.
For 132 kV Feeder Capable of integration into Existing SAS at Namrup GSS
Current Transformers (1-phase) with terminal connectors, marshelling box etc. as per specification
132 kV, 400-200/1-1-1-1-1 Line CT
Isolators with insulators, terminal connectors, structures complete etc. as per specification
132 kV horizontal centre break isolator With Single Earth Switch (3-phase)
132 kV horizontal centre break isolator Without Earth Switch (3-Phase)
Lightning Arrester with terminal connectors etc. as per specification
132 kV Lightning Arrester
Post Insulator with terminal connectors etc. as per specification
132 kV Post Insulator
132 kV CVT with terminal connectors etc as per specfication.
Supply of Mounting structures with mounting & foundation bolts as per drawings supplied for
132 kV Line CT
132kV Isolator With Single Earth Switch
132kV Isolator Without Earth Switch
132kV Lightning Arrester
132kV Post Insulator
132kV CVT
Supply and Design of Bay Steel Structures including nuts, bolts, spring washers etc. except equipment mounting structures
Column
Column Type 'C1' ( 3 Nos.) [ 2317.41 Kg/ per Column ]
Column Type 'C2' ( 4 Nos.) [ 1913.04 Kg/ per Column ]
Beams
Beam Type 'B1' ( 6 Nos.) [ 751.77 Kg/ per Beam ]
Supply of Power Cables
Supply of Control Cables
Supply of ACSR Zebra Conductor
Supply of ACSR Panther Conductor
Disc Insulator Strings complete with all hardware fittings, clamps etc.
10 Disc Tension Insulator String(90KN)
9 Disc Suspension Insulator String(90KN)
Supply of Earthing System Materials
Main Earth mat (65x12 mm GI Flat)
65x12 GI flat for risers, equipment earthing, column earthing etc.
50x6 GI flat Earthing conductor for earthing of indoor L.T & control panels, Junction box, Marshalling boxes, cable trenches etc.
40 mm Dia. 3mtr long M.S. rod earth electrode (driven) with test link for each tower with earth peak, LAs & CVTs.
Supply of Bay Marshalling Kiosk along with mounting structure
Clamps and Connectors
PG Clamp With Connectors and all hardware fittings sutiable for ACSR Panther Conductor
T Clamp With Connectors and all hardware fittings sutiable for ACSR Panther Conductor
Tee Connector Rigid through Type alongwith all hardware fittingsfor 132kV LA and sutiable for ACSR Panther Conductor
Tee Connector Rigid through Type alongwith all hardware fittingsfor 132kV CVT and sutiable for ACSR Panther Conductor
Supply of ABT meter as per specification
Supply of 220 Volt Battery Bank, charger, DCDB & 415 V ACDB
Supply of 220 Volt 400 Ah VRLA Battery bank with battery stand and all other fittings and accessories as per specification
Supply of 220 Volt Battery charger with all fittings and accessories as per specification
Supply of 220 Volt DC DB, with all fittings and accessoreies as per specification
Supply of 415 Volt, 500 A, 3-ph cubicle type indoor floor mounted, auxiliary service board, with all fittings and accessoreies as per specification
Supply of 48 Volt Battery Bank, charger, DCDB
Supply of 48 Volt 150 Ah VRLA Battery bank with battery stand and all other fittings and accessories as per specification
Supply of Automatic float and float cum boost charger 50 A suitable for 48 V 150 Ah VRLA Battery & charger with all fittings and accessories and shall be as per specification
Supply of 48 Volt DC DB, with all fittings and accessoreies as per specification
132kV main Bus extension
Supply of Tension Clamps
Supply of TEE Clamps for zebra conductor
Isolator clamp for single zebra
PI clamps for single Zebra
UPG clamps for single Zebra
Double Zebra and connecting Single Zebra clamps (Twin Tee)
Double Zebra and connecting Single Panther clamps (Twin Tee)
Space of Zebra
Nuts & bolts with washer etc.
132kV Transfer BUS Extension
Supply of Tension Clamps
Supply of TEE Clamps for Panther conductor
Isolator clamp for single panther
PI clamps for single Panther
UPG clamps for single Panther
Nuts & bolts with washer etc.
Mandatory Spares
For 132 kV SF6 Circuit Breakers
Interrupter
Tripping Coil
Closing Coil
Spring Charging Motor
SF6 gas density monitoring device
Set of sll type of gasket used with sealing agent
Circuit Breaker operating mechanism cabinet with all fittings and accessories
SF6 gas filled cylinder-12kg
For Control & Relay panels
Over current relay
Earth fault relay
Distance protection Relay
Master Trip Relay
Ethernet Switch
OFC cable 15 mtr length with termination equipment
132kV Lightning Arrester
132kV , 400-200/1-1-1-1-1 Line CT
132kV, isolator moving and fixed contact
Terminal connectors for 132kV CT
Terminal connectors for 132kV isolator
Tee Clamp to suit "Single Zebra" to "Single Zebra Conductor"
Tee Clamp to suit "Single Panther" to "Single ACSR Panther"
Fire Fighting equipments
25 Kg Capacity FE DCP type, trolley mounted
FE CO2 6.5 kg capacity, wall mounted
Fire Buckets (12 Nos. with stand in one set)
Supply and installation of 2TON 5star AC
Supply of Measuring instruments
Digital Earth Resistance Meter
Earth Stick
Description of Work / Item(s)
Amount
Circuit Breakers with mounting structures and terminal connectors etc.as applicable as per specification
132 kV Gang operated outdoor SF6 Breakers
SIEMENS made Control & Relay Panel with Automation (Simplex Type) complete with BCU, ethernet switch and all accessories as required for SAS integration.
For 132 kV Feeder Capable of integration into Existing SAS at Namrup GSS
Current Transformers (1-phase) with terminal connectors, marshelling box etc. as per specification
132 kV, 400-200/1-1-1-1-1 Line CT
Isolators with insulators, terminal connectors, structures complete etc. as per specification
132 kV horizontal centre break isolator With Single Earth Switch (3-phase)
132 kV horizontal centre break isolator Without Earth Switch (3-Phase)
Lightning Arrester with terminal connectors etc. as per specification
132 kV Lightning Arrester
Post Insulator with terminal connectors etc. as per specification
132 kV Post Insulator
132 kV CVT with terminal connectors etc as per specfication.
Supply of Mounting structures with mounting & foundation bolts as per drawings supplied for
132 kV Line CT
132kV Isolator With Single Earth Switch
132kV Isolator Without Earth Switch
132kV Lightning Arrester
132kV Post Insulator
132kV CVT
Supply and Design of Bay Steel Structures including nuts, bolts, spring washers etc. except equipment mounting structures
Column
Column Type 'C1' ( 3 Nos.) [ 2317.41 Kg/ per Column ]
Column Type 'C2' ( 4 Nos.) [ 1913.04 Kg/ per Column ]
Beams
Beam Type 'B1' ( 6 Nos.) [ 751.77 Kg/ per Beam ]
Supply of Power Cables
Supply of Control Cables
Supply of ACSR Zebra Conductor
Supply of ACSR Panther Conductor
Disc Insulator Strings complete with all hardware fittings, clamps etc.
10 Disc Tension Insulator String(90KN)
9 Disc Suspension Insulator String(90KN)
Supply of Earthing System Materials
Main Earth mat (65x12 mm GI Flat)
65x12 GI flat for risers, equipment earthing, column earthing etc.
50x6 GI flat Earthing conductor for earthing of indoor L.T & control panels, Junction box, Marshalling boxes, cable trenches etc.
40 mm Dia. 3mtr long M.S. rod earth electrode (driven) with test link for each tower with earth peak, LAs & CVTs.
Supply of Bay Marshalling Kiosk along with mounting structure
Clamps and Connectors
PG Clamp With Connectors and all hardware fittings sutiable for ACSR Panther Conductor
T Clamp With Connectors and all hardware fittings sutiable for ACSR Panther Conductor
Tee Connector Rigid through Type alongwith all hardware fittingsfor 132kV LA and sutiable for ACSR Panther Conductor
Tee Connector Rigid through Type alongwith all hardware fittingsfor 132kV CVT and sutiable for ACSR Panther Conductor
Supply of ABT meter as per specification
Supply of 220 Volt Battery Bank, charger, DCDB & 415 V ACDB
Supply of 220 Volt 400 Ah VRLA Battery bank with battery stand and all other fittings and accessories as per specification
Supply of 220 Volt Battery charger with all fittings and accessories as per specification
Supply of 220 Volt DC DB, with all fittings and accessoreies as per specification
Supply of 415 Volt, 500 A, 3-ph cubicle type indoor floor mounted, auxiliary service board, with all fittings and accessoreies as per specification
Supply of 48 Volt Battery Bank, charger, DCDB
Supply of 48 Volt 150 Ah VRLA Battery bank with battery stand and all other fittings and accessories as per specification
Supply of Automatic float and float cum boost charger 50 A suitable for 48 V 150 Ah VRLA Battery & charger with all fittings and accessories and shall be as per specification
Supply of 48 Volt DC DB, with all fittings and accessoreies as per specification
132kV main Bus extension
Supply of Tension Clamps
Supply of TEE Clamps for zebra conductor
Isolator clamp for single zebra
PI clamps for single Zebra
UPG clamps for single Zebra
Double Zebra and connecting Single Zebra clamps (Twin Tee)
Double Zebra and connecting Single Panther clamps (Twin Tee)
Space of Zebra
Nuts & bolts with washer etc.
132kV Transfer BUS Extension
Supply of Tension Clamps
Supply of TEE Clamps for Panther conductor
Isolator clamp for single panther
PI clamps for single Panther
UPG clamps for single Panther
Nuts & bolts with washer etc.
Mandatory Spares
For 132 kV SF6 Circuit Breakers
Interrupter
Tripping Coil
Closing Coil
Spring Charging Motor
SF6 gas density monitoring device
Set of sll type of gasket used with sealing agent
Circuit Breaker operating mechanism cabinet with all fittings and accessories
SF6 gas filled cylinder-12kg
For Control & Relay panels
Over current relay
Earth fault relay
Distance protection Relay
Master Trip Relay
Ethernet Switch
OFC cable 15 mtr length with termination equipment
132kV Lightning Arrester
132kV , 400-200/1-1-1-1-1 Line CT
132kV, isolator moving and fixed contact
Terminal connectors for 132kV CT
Terminal connectors for 132kV isolator
Tee Clamp to suit "Single Zebra" to "Single Zebra Conductor"
Tee Clamp to suit "Single Panther" to "Single ACSR Panther"
Fire Fighting equipments
25 Kg Capacity FE DCP type, trolley mounted
FE CO2 6.5 kg capacity, wall mounted
Fire Buckets (12 Nos. with stand in one set)
Supply and installation of 2TON 5star AC
Supply of Measuring instruments
Digital Earth Resistance Meter
Earth Stick
Description of Work / Item(s)
Amount
Erection, testing & commissioning of Circuit Breakers including laying & terminating of LT power and control cables as required
132 kV Gang operated SF6 Breakers
Erection, testing & commissioning of Control & Relay Panels including laying & terminating of LT power and control cables as required
For 132 kV Feeder compatible with existing SAS (SIEMENS) at Namrup GSS
Erection, testing & commissioning of Current transformers including laying & terminating of control cables as required
132 kV, 400-200/1-1-1-1-1 Line CT
Erection, testing & commissioning of Isolators including laying & terminating of LT power and control cables as required
132 kV With Single Earth Switch
132 kV Without Earth Switch
Erection, testing & commissioning of Lightning Arrester including including laying & terminating of control cables as required
132 kV Lightning Arrester
Erection, testing & commissioning of Post Insulator including including laying & terminating of control cables as required
132 kV Post Insulator
Erection, testing & commissioning of CVT including including laying & terminating of control cables as required
132kV CVT
Erection of Mounting structures for different terminal equipments as required for
132 kV Line CT
132kV Isolator With Single Earth Switch
132kV Isolator Without Earth Switch
132kV Lightning Arrester
132kV Post Insulator
132kV CVT
Erection of Switchyard Lattice Steel Columns
Column Type 'C1' ( 3 Nos.) [ 2317.41 Kg/ per Column ]
Column Type 'C2' ( 4 Nos.) [ 1913.04 Kg/ per Column ]
Erection of Switchyard Lattice Steel Beams
Beam Type 'B1' ( 6 Nos) [ 751.77 Kg/ per Beam ]
Integration of Control Relay Panel into the existing Substation Automation System (SAS) of SIEMENS made at Namrup GSS.
Hoisting of Insulator strings, Stringing of Conductors, GI shield wire etc including supply of disc insulator strings, clamps, GI stranded shield wire, connectors etc. As required for whole scope of works
Installation of earthing system with GI flats, electrodes etc. For present scope of area
Construction of Cable Trenches including supply of all materials and labour as per specification and drawing
C Type Trench with supply and installation of cable tray(300mm wide)
D Type Trench(sand filled)
Illumination
Design and installation of outdoor illumination system for the 132kV bay area (consisting of minimum 10 Nos. of LED lamps with fittings etc.) as per specification including supply of all materials.
Erection of Bay Marshalling Kiosk as per drawings and specifications including construction of foundation inclusive of supply of all foundation Materials and Labour as directed.
Erection, testing and Commissssioning of ABT Meter as per specification
Erection, testing and Commissssioning of 220 Volt Battery Bank, charger, DCDB & 415 V ACDB
220 Volt 400 Ah VRLA Battery bank with battery stand and all other fittings and accessories as per specification
220 Volt Battery charger with all fittings and accessories as per specification
220 Volt DC DB, with all fittings and accessoreies as per specification
415 Volt, 500 A, 3-ph cubicle type indoor floor mounted, auxiliary service board, with all fittings and accessoreies as per specification
Erection, testing and Commissssioning of 48 Volt Battery Bank, charger, DCDB
48 Volt 150 Ah VRLA Battery bank with battery stand and all other fittings and accessories as per specification
Automatic float and float cum boost charger 50 A suitable for 48 V 150 Ah VRLA Battery & charger with all fittings and accessories and shall be as per specification
48 Volt DC DB, with all fittings and accessoreies as per specification
Stringing of Conductors etc. for extension of 132kV Main Bus and transfer bus As required for whole scope of works
Providing 80 mm thick 1:4:8 PCC base of switchyard as per specification & drawings including supply of all materials
Providing 100mm thick gravelling of switchyard as per specification & drawings including supply of all materials
Description of Work / Item(s)
Amount
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Circuit Breaker (1 Set)
Excavation (16.21 Cum per breaker)
Filling (10.73 Cum per breaker)
Brick Soiling (8 Sq.m per breaker)
Formwork (15.36 Sq.m per breaker)
PCC (0.46 Cum per breaker)
RCC (4.22 Cum per breaker)
Reinforcement (209.75 Kg per breaker)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Current Transformer ( 3 Nos.)
Excavation (4.29 Cum per CT)
Filling (3.48 Cum per CT)
Brick Soiling (1.82 Sq.m per CT)
Formwork (6.56 Sq.m per CT)
PCC (0.10 Cum per CT)
RCC (0.52 Cum per CT)
Reinforcement (86.18 Kg per CT)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV CVT (3 Nos.)
Excavation (4.29 Cum per CVT)
Filling (3.48 Cum per CVT)
Brick Soiling (1.82 Sq.m per CVT)
Formwork (6.56 Sq.m per CVT)
PCC (0.10 Cum per CVT)
RCC (0.52 Cum per CVT)
Reinforcement (86.18 Kg per CVT)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Isolators With/ Without Earth Switch ( 3 Sets)
Excavation (25.13 Cum per Isolator)
Filling (20.40 Cum per Isolator)
Brick Soiling (11.81 Sq.m per Isolator)
Formwork (16.11 Sq.m per Isolator)
PCC (0.72 Cum per Isolator)
RCC (2.83 Cum per Isolator)
Reinforcement (246.07 Kg per Isolator)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Lightning Arresters( 3 Nos)
Excavation (3.52 Cum per LA)
Filling (2.75 Cum per LA)
Brick Soiling (1.56 Sq.m per LA)
Formwork (3.88 Sq.m per LA)
PCC (0.08 Cum per LA)
RCC (0.54 Cum per LA)
Reinforcement (46.65 Kg per LA)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for 132kV Post Insulator ( 10 Nos)
Excavation (3.52 Cum per PI)
Filling (2.75 Cum per PI)
Brick Soiling (1.56 Sq.m per PI)
Formwork (3.88 Sq.m per PI)
PCC (0.08 Cum per PI)
RCC (0.54 Cum per PI)
Reinforcement (46.65 Kg per PI)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for Lattice Steel Column ( Columns Type (C1), 3 Nos.)
Excavation (149 Cum per Column)
Filling (33 Cum per Column)
Formwork (14.19 Sq.m per Column)
PCC ( 2.444 Cum per Column)
RCC (8.59.Cum per Column)
Reinforcement (668.2Kg per Column)
Brick Soiling (24.44 Sqm per Column)
Construction of Foundation Including. Supply of All Foundation Materials & Labour as required for Lattice Steel Column ( for 132kV lightning posts 2 Nos. & supporting Column Type (C2), 4Nos)
Excavation (110.55 Cum per Column)
Filling (97.229 Cum per Column)
Formwork (23.96 Sq.m per Column)
PCC ( 1.79Cum per Column)
RCC (8.59.Cum per Column)
Reinforcement (855.89 Kg per Column)
Brick Soiling (25.5 Sqm per Column)
Water Sump Pit as per site requirement
Construction of new switchyard approach road with paver block as per site requirement.
Land development and site cleaning: Earth filing , removal of tree stumps, roots, permanent and temporary structures, and existing switchyard approach road,foundations, decomposed organic matter, slush, mud etc. and backfiling to make the land profile even and compact as per requirement of the site alongwith disposal of excess soil and unwanted materials outside the campus as directed.
D KUMAR AND COMPANY
HI-TECH CORPORATION
ABN Tower and Transmission Private Limited
Jayanta Khaund
ABN Tower and Transmission Private Limited
HI-TECH CORPORATION
D KUMAR AND COMPANY
Jayanta Khaund
ABN Tower and Transmission Private Limited
D KUMAR AND COMPANY
HI-TECH CORPORATION
ABN Tower and Transmission Private Limited
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .