Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-AOC HOSHANGABAD M P | HOSHANGABAD | MADHYA PRADESH | L1 | Accepted-AOC L1 | |
| 2 | L2₹2.2 L+₹34,520 (18.2%)Rejected-Finance 357 A NEW CHOUKSEY NAGAR LAMBAKEDA BHOPAL M P | BHOPAL | MADHYA PRADESH | L2 | Rejected-Finance L2 | |
| 3 | L3₹2.3 L+₹42,070 (22.1%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical not as per NIT conditions |
Tender Value
Refer Docs
EMD Value
₹3,940
Closing Date
9 Jul 2021, 6:00 pmClosed
Project Engineer
D 5/2 MIG Mahashweta Nagar, Ujjain
External Electrification work (L.T. Line Extension) for Police chowki Bhawan, Harangaon Distt. Dewas
2021_MPPHC_148864_1
NIT 12/2021-22_2
Open Tender
Electrical Works
Item Rate
30 days
Harangaon
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹3,940
28 Jul 2021
30 Jun 2021
12 Jul 2021
30 Jun 2021
9 Jul 2021
4 Jul 2021
Amount
Supplying and erection of HT/LT over head line single length supports complete with aligning and keeping it in truly vertical position, including digging pit of required size in all type of soil/rocks filling with 1:3:6 cement concrete of 0.60 mtr. dia. around the pole up to ground level including muffing of 0.45 mtr. dia. from ground level to 0.45 mtr. high as per specifications with 20 cm. thick base foundation in 1:4:8 cement concrete as required refilling the pit with boulder and soil as required, including painting of pole with bitumen paint below GL and two coats of red oxide and two coats of aluminium paint or synthetic enamel paint above GL as directed complete as per specification. The depth of burying of pole shall be 1/6th of the length of pole.
PCC POLE 8.0 Mtr Long 140 KGS
H Beam 13 Mtr Long 152x152 or 150x150 mm 37.1 Kg/Mtr. weight
Supplying and fixing of angle / channel / flat iron / RS Joist fittings for over head lines as cross arms / brackets / clamps etc. including nut bolts, required holes, welding, cutting, fabricating with necessary materials including two coats of red oxide and two coats of aluminium or synthetic enamel paint etc. as required.
Supplying and erection of GI/MS stay set complete with stay rod, anchor plate of size 300x300x5mm, thimble, stay clamp, turn buckle, bow tightener etc. with stay wire, strain insulator, nut bolts as per specifications including excavation in all type of soil/ rocks and foundation in cement concrete 1:3:6 of required size and other necessary materials complete as required as per specifications.
GI Stay Rod 16mm dia 1.8 m long with 7/3.15mm stay wire for LT line
GI Stay Rod 20 mm dia 1.8 m long with 7/3.15mm stay wire for LT line
Supplying, laying, testing and commissioning of XLPE insulated and PVC sheathed heavy duty power cable confirming to IS 7098/Part-I/88 with latest amendments, 1100 volts grade armoured cable of approved make with aluminium solid / stranded conductor. The cable shall be laid in air/in existing pipe/in existing cable trench/on existing cable tray with clamp as required as per specifications including providing of metal/PVC cable identification tags at both ends and every 10 Mtr. length of cable with inscriptions there on.
ABC Cable 3x50+1x35+1x16 Sqmm
Supplying and fixing street light with high power LED of 1 to 3 W each assembled on single MCPCB, system lumens output with efficacy>90 lm/W. luminiare having color temp 6500K & 50000 burning hrs life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF 0.95 & surge protection 3KV. Housing made of pressure die cast aluminium with heat resistant flat glass / Lens type, IP65 protection. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer manadatory i/c 50mm.dia G.I. Pipe bracket upto 2 mtr. long in required angle/shape, connection lead, testing etc to complete the job. 2 Yrs Guarantee certificate from manufacturer A-90 W
Supplying Fixing And Testing Junction Box busbar Loaded Complete As per Required by MPSEB Required.
Supplying installing, fixing, testing and commissioning hanging clamp as per MPPKVVCL specification completed.
Supplying installing, fixing, testing and commissioning suspention clamp as per MPPKVVCL specification completed.
Supplying installing, fixing, testing and commissioning Dead end clamp as per MPPKVVCL specification completed.
Supplying installing, fixing, testing and commissioning piercieng connector as per MPPKVVCL specification completed. A.Type-I
(1) The contractor is responsible for approval fo transformer/sub station/HT/LT lines/ Testing of LTCT. Meter, form competent authority of Electrical Inspector and energy station/commissioning of sub station HT/LT lines and necessary shut down form MPMKVVCO. No extra payment will be done for this job (2) Quantities/ items may increased/ decrease as per site conditions. (3) Ready to carryout maintenance work if failure of any equipment i.e. transformer, Line in colony within 5 year period from the date handing over. (4) All Material for use in External Electrification work of as per approved List attached.
PRABHU ELECTRICALS
Pankaj Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .