Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.5 LAdmitted-Finance | ₹41.5 L | L1 | Admitted-Finance |
| 2 | L2₹45.9 LAdmitted-Finance 340 11 M S NATIONAL ENGINEERING CORP 340 11 SATTI STREET ROORKEE ROORKEE HARIDWAR UTTARAKHAND 247667 UDYAM UK 06 0007176 05BFAPA4905A2ZF R M MSME STATUS AS VERIFIED | HARIDWAR | UTTARAKHAND | 247667 | ₹45.9 L | L2 | Admitted-Finance |
| 3 | L3₹46.3 LAdmitted-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | ₹46.3 L | L3 | Admitted-Finance |
| 4 | L4₹51.7 LAdmitted-Finance S NO 259 LOHOGAON ROAD KALWAD PUNE 411032 | PUNE | MAHARASHTRA | 411032 | ₹51.7 L | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Rama Electricals L4 | vedant engineering enterprises L1 | NATIONAL ENGINEERING CORPORATION L2 | Adinath Technical Services L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting all electric cables and connections from the existing VCB's, taking down, depositing in MES store yard and Supply, install & commissioning of 11 KV VCB, 630 Amps with copper bus bar of 50x10mm & rupturing capacity of 315 MVA with sufficient clearance, safety and operation inside the enclosure, CPRI approved including cable termination chamber. VCB shall have following features -
(i) Circuit breaker, Rated Current : 630A, closing and Tripping coil : 240V DC, Spring Charging motor : 230V AC, STC : 26.3KA for 03 sec
a) PT - Three Phase Top Mounted Resin Case PT: 11000V / √3 / 110V / √3 /, Cl 1, 50VA / Cl3P, 50VA.
b) 200-100 /5+5A ; 7.5VA/ CL.1 +7.5 VA / CL. 5P10
c) Digital Ammeter - 96 Sq MM with s/s
d) Digital Voltmeter - 96 SqMM with s/s
e) Digital MFM - 96 Sq MM with s/s
f) 01 No O/C Relay
g) 01 No E/F Relay
h) Electromechanical Type Master Trip Relay
i) Electromechanical Type Aux Relay for Transformer fault
j) Indication Lamps -
VCB – ON --- Red
VCB – OFF --- Green
Auto Trip --- Amber
Trip Ckt. Healthy --- White
Spring charged. --- Blue | 3 | Each | 8,40,000 ₹25.2 L | 5,45,000 ₹16.4 L | 7,15,000 ₹21.4 L | 6,54,192 ₹19.6 L |
| 1.01Item No. 1 Continued :- R, Y, B - Phase Breaker in Service and Breaker in Test k) Breaker Control Switch --T-N-C -Non Lockable type. l) Heater with Thermostat & Switch. m) LR Switch n) P.B. --- Trip Ckt. Healthy Chk o) Panel Illumination Lamp with switch p) Socket with Switch q) MCB & Contactor r) Power pack -- 230VAC to 110VDC s) 8 Window Annunciator with Hooter | |||||||
| 2.00 | Disconnecting all electric cables and connections from the existing VCB's, taking down, depositing in MES store yard and Supply, install & commissioning of 11 KV VCB, 800 Amps with copper bus bar of 50x10mm & rupturing capacity of 315 MVA with sufficient clearance, safety and operation inside the enclosure, CPRI approved including cable termination chamber. VCB shall have following features -
(i) Circuit breaker, Rated Current: 800 A, closing and Tripping coil : 240V DC, Spring Charging motor : 230V AC, STC : 26.3KA for 03 sec
a) PT - Three Phase Top Mounted Resin Case PT : 11000V / √3 / 110V / √3 / , Cl 1 , 50VA / Cl3P, 50VA.
b) 200-100 /5+5A ; 7.5VA/ CL.1 +7.5 VA / CL. 5P10
c) Digital Ammeter - 96 Sq MM with s/s
d) Digital Voltmeter - 96 Sq MM with s/s
e) Digital MFM - 96 Sq MM with s/s
f) 01 No O/C Relay
g) 01 No E/F Relay
h) Electromechanical Type Master Trip Relay
i) Electromechanical Type Aux Relay for Transformer fault
j) Indication Lamps -
VCB – ON --- Red
VCB – OFF --- Green
Auto Trip --- Amber
Trip Ckt. Healthy --- White
Spring charged. --- Blue
R,Y,B Phase
Breaker in Service and Breaker in Test
k) Breaker Control Switch --T-N-C -Non Lockable type. | 1 | Each | 8,40,000 ₹8.4 L | 5,55,000 ₹5.5 L | 7,20,000 ₹7.2 L | 6,69,768 ₹6.7 L |
| 2.01Item No. 2 Continued :- l) Heater with Thermostat & Switch. m) LR Switch n) P.B. --- Trip Ckt. Healthy Chk o) Panel Illumination Lamp with switch p) Socket with Switch q) MCB & Contactor r) Power pack -- 230VAC to 110VDC s) 8 Window Annunciator with Hooter | |||||||
| 3.00 | Supply and fix HT 33 KV out door type gang operated air-break switch suitable for horizontal or vertical mounting, fixed type complete with 9 insulators and with earth switch upto 400 Amps complete all as specified and directed. | 1 | Each set | 47,000 ₹47,000 | 63,000 ₹63,000 | 43,000 ₹43,000 | 52,491 ₹52,491 |
| 4.00 | Supplying, fixing, jointing and testing heat shrinkable cable end joint, Indoor type with and including jointing materials suitable for 11 KV, XLPE cable of size 120 sqmm, 3 core, complete all as specified and directed. | 5 | Each | 3,500 ₹17,500 | 3,400 ₹17,000 | 3,400 ₹17,000 | 3,267 ₹16,335 |
| 5.00 | Supplying, fixing, jointing and testing heat shrinkable cable end joint, out door type with and including jointing materials suitable for 11 KV, XLPE cable of size 120 sqmm, 3 core, complete all as specified and directed. | 4 | Each | 3,500 ₹14,000 | 4,000 ₹16,000 | 3,800 ₹15,200 | 3,869 ₹15,476 |
| 6.00 | Supply, Laying, jointing and testing underground cable heavy duty, 11000 Volts, XLPE (earthed) insulated and sheathed, armoured with multi-stranded aluminium conductor cable, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes complete all as specified and directed of 120 sqmm 3 core size. | 776 | RM | 1,600 ₹12.4 L | 1,550 ₹12.0 L | 1,400 ₹10.9 L | 1,661 ₹12.9 L |
| 7.00 | Supply & lay in trenches double walled corugated HDPE pipe 110 mm dia for protection of under ground cablesincluding pipe couplers with seal, bends, end covers etc complete all as specified and directed | 734.87 | RM | 140 ₹1.0 L | 180 ₹1.3 L | 220 ₹1.6 L | 218 ₹1.6 L |
| 8.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge. | 297.62 | Cum | 120 ₹35,714.40 | 180 ₹53,571.60 | 80 ₹23,809.60 | 180 ₹53,571.60 |
Updated dates
Tender Value
₹47.2 L
EMD Value
₹95,000
Closing Date
18 May 2026, 6:00 pmClosed
CWE DEOLALI
HQ CWE DEOLALI, ONSLOW ROAD, DEOLALI (MH) 422401
AS PER TENDER DOCUMENTS
2026_MES_761040_1
86099/E8
Open Tender
Electrical and Maintenance Works
180 days
GE DEOLALI
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE DEOLALI
₹95,000
Yes
1 Jun 2026
20 Apr 2026
25 May 2026
20 Apr 2026
18 May 2026
4 May 2026
21 Apr 2026 - 27 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Disconnecting all electric cables and connections from the existing VCB's, taking down, depositing in MES store yard and Supply, install & commissioning of 11 KV VCB, 630 Amps with copper bus bar of 50x10mm & rupturing capacity of 315 MVA with sufficient clearance, safety and operation inside the enclosure, CPRI approved including cable termination chamber. VCB shall have following features -
(i) Circuit breaker, Rated Current : 630A, closing and Tripping coil : 240V DC, Spring Charging motor : 230V AC, STC : 26.3KA for 03 sec
a) PT - Three Phase Top Mounted Resin Case PT: 11000V / √3 / 110V / √3 /, Cl 1, 50VA / Cl3P, 50VA.
b) 200-100 /5+5A ; 7.5VA/ CL.1 +7.5 VA / CL. 5P10
c) Digital Ammeter - 96 Sq MM with s/s
d) Digital Voltmeter - 96 SqMM with s/s
e) Digital MFM - 96 Sq MM with s/s
f) 01 No O/C Relay
g) 01 No E/F Relay
h) Electromechanical Type Master Trip Relay
i) Electromechanical Type Aux Relay for Transformer fault
j) Indication Lamps -
VCB – ON --- Red
VCB – OFF --- Green
Auto Trip --- Amber
Trip Ckt. Healthy --- White
Spring charged. --- Blue | - | Each | - | - | |
Item No. 1 Continued :-
R, Y, B - Phase
Breaker in Service and Breaker in Test
k) Breaker Control Switch --T-N-C -Non Lockable type.
l) Heater with Thermostat & Switch.
m) LR Switch
n) P.B. --- Trip Ckt. Healthy Chk
o) Panel Illumination Lamp with switch
p) Socket with Switch
q) MCB & Contactor
r) Power pack -- 230VAC to 110VDC
s) 8 Window Annunciator with Hooter | - | - | - | - | |
Disconnecting all electric cables and connections from the existing VCB's, taking down, depositing in MES store yard and Supply, install & commissioning of 11 KV VCB, 800 Amps with copper bus bar of 50x10mm & rupturing capacity of 315 MVA with sufficient clearance, safety and operation inside the enclosure, CPRI approved including cable termination chamber. VCB shall have following features -
(i) Circuit breaker, Rated Current: 800 A, closing and Tripping coil : 240V DC, Spring Charging motor : 230V AC, STC : 26.3KA for 03 sec
a) PT - Three Phase Top Mounted Resin Case PT : 11000V / √3 / 110V / √3 / , Cl 1 , 50VA / Cl3P, 50VA.
b) 200-100 /5+5A ; 7.5VA/ CL.1 +7.5 VA / CL. 5P10
c) Digital Ammeter - 96 Sq MM with s/s
d) Digital Voltmeter - 96 Sq MM with s/s
e) Digital MFM - 96 Sq MM with s/s
f) 01 No O/C Relay
g) 01 No E/F Relay
h) Electromechanical Type Master Trip Relay
i) Electromechanical Type Aux Relay for Transformer fault
j) Indication Lamps -
VCB – ON --- Red
VCB – OFF --- Green
Auto Trip --- Amber
Trip Ckt. Healthy --- White
Spring charged. --- Blue
R,Y,B Phase
Breaker in Service and Breaker in Test
k) Breaker Control Switch --T-N-C -Non Lockable type. | - | Each | - | - | |
Item No. 2 Continued :-
l) Heater with Thermostat & Switch.
m) LR Switch
n) P.B. --- Trip Ckt. Healthy Chk
o) Panel Illumination Lamp with switch
p) Socket with Switch
q) MCB & Contactor
r) Power pack -- 230VAC to 110VDC
s) 8 Window Annunciator with Hooter | - | - | - | - | |
Supply and fix HT 33 KV out door type gang operated air-break switch suitable for horizontal or vertical mounting, fixed type complete with 9 insulators and with earth switch upto 400 Amps complete all as specified and directed. | - | Each set | - | - | |
Supplying, fixing, jointing and testing heat shrinkable cable end joint, Indoor type with and including jointing materials suitable for 11 KV, XLPE cable of size 120 sqmm, 3 core, complete all as specified and directed. | - | Each | - | - | |
Supplying, fixing, jointing and testing heat shrinkable cable end joint, out door type with and including jointing materials suitable for 11 KV, XLPE cable of size 120 sqmm, 3 core, complete all as specified and directed. | - | Each | - | - | |
Supply, Laying, jointing and testing underground cable heavy duty, 11000 Volts, XLPE (earthed) insulated and sheathed, armoured with multi-stranded aluminium conductor cable, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes complete all as specified and directed of 120 sqmm 3 core size. | - | RM | - | - | |
Supply & lay in trenches double walled corugated HDPE pipe 110 mm dia for protection of under ground cablesincluding pipe couplers with seal, bends, end covers etc complete all as specified and directed | - | RM | - | - | |
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge. | - | Cum | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
86099TENDERDOCSALL.pdf
Tender Documents • 1.99 MB
BOQ_852472.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid