Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC VILL POST GOASI DIST PURNEA BIHAR 854301 | PURNEA | PURNEA | BIHAR | 854301 | L1 | Accepted-AOC Being lowest quoted amount | |
| 2 | L2₹9.7 L+₹44,936 (4.87%)Rejected-Finance | L2 | Rejected-Finance Being highest quoted amount. | |
| 3 | L3₹9.8 L+₹60,735 (6.58%)Rejected-Finance | L3 | Rejected-Finance Being highest quoted amount. | |
| 4 | L4₹10.0 L+₹80,310 (8.71%)Rejected-Finance | L4 | Rejected-Finance Being highest quoted amount. | |
| 5 | L5₹10.0 L+₹81,807 (8.87%)Rejected-Finance | L5 | Rejected-Finance Being highest quoted amount. |
Tender Value
₹9.0 L
EMD Value
₹17,960
Closing Date
30 Oct 2024, 6:00 pmClosed
AGE (I) AF PURNEA
AGE (I) AF PURNEA, P.O - CHUNAPUR AIR FIELD, DIST- PURNEA BIHAR, PIN CODE- 854303
REPAIR REPLACEMENT TO INTERNAL WIRING AND CONNECTED WORKS AT CERTAIN OTM ACCN IN DOMESTIC AND TECHNICAL AREA AT AF STN PURNEA UNDER AGE I AF PURNEA
2024_MES_678863_1
8099/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Purnea
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
AGE (I) AF PURNEA
₹17,960
Yes
18 Nov 2024
9 Oct 2024
1 Nov 2024
9 Oct 2024
30 Oct 2024
23 Oct 2024
Amount
Taking down carefully copper/alluminium point, wiring (light, fan, socket or power) complete including fixtures and fitting such as switches, ceiling roses, pendants, regulator socket light fitting etc, removing materials to store for keeping in safe custody for or for taking credit (credit for above items should be made as per condition seperately) and makeing good disturbed surfaces of walls , floors etc.complete all as specified and as directed.
M&L for concealed point wiring complete with 1.5 sq mm FRLSH, PVC insulated multi stranded copper conductor single core cable 1100 volts grade,drawn into non metalic PVC rigid conduit medium grade of suitable size and conduit accessories fixed on wall, floor, roof etc. and including provision of PVC insulated 1.5 sq mm copper conductor for each continuity and connected to common earth dolly and pressed steel terminal boxes made out of 1.6 mm thick modular metal flush boxes concealed in wall and modular cover plate with frame for housing the switches socket outlet etc all as specified and directed by Engineer-in-Charge for one light point/ fan point controled by one one way 6 Amp switch .complete all as specified and as directed. Note :- (i) Cost of PVC conduit, cutting chases of wall, making good disturbed wall surfaces including finishing with cement mortor (1:4), matching with existing colour/paint of surface are deemed to be included in the quoted rate.complete all as specified and as directed. (ii) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
All as per item No.2 here- in-above but for one 3 pin socket outlet 5 Amps on independent board ,complete all as specified and as directed.
All as per item No.2 here- in- above but for one 3 pin socket outlet 5 Amp on same board with other switches, complete all as specified and as directed.
Material and labour wiring for socket out let on independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and as directed.
Material and labour for point wiring for light point/ fan point one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FR cables in and including suitable size PVC casing and caping (ISI marked) , including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FR PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. Note :- (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
All as per item No.09 here-in-above but for One 3 pin 5 Amps socket out let points on independent board,complete all as specified and directed.
All as per item No.09 here-in-above but for 5 Amp socket on same board with other switches.complete all as specified and directed.
Material and labour point wiring for one socket outlet on independent board controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated Unsheathed FRLS cables in and including suitable size PVC casing and caping (ISI marked) , including pressed steel terminal switch boxes,3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable as earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. Note :- (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
Supply and fixing switch piano flush type 6 amps 230 volt single pole one way complete all as specified and as directed.
Supply and fixing switch socket combination multipurpose 2 in 1, 5 pin 6 amps 230 volt flush type complete all as specified and as directed.
Supply and fixing socket outlet 2 in 1 , 3 pin 6 Amps, 230/240 volt flush type complete all as specified and as directed.
Supply and fixing 6 Amp /16 Amp switch socket combination multipurpose 5 in 1, 6 pin, 230 volt flush type with fuse & neon indicatorcomplete all as specified and as directed.
Supply and fixing ceiling rose surface bakelite three terminal (65 x 50)mm complete all as specified and as directed.
Supply and fixing eletronic fan regulator step type AC 240 volt 50 Hz complete all as specified and directed.
Supply and fixing bell push flush type 5 Amps complete all as specified and as directed.
Supply and fixing bell ding dong AC 230 volts, single pole complete all as specified and as directed.
Supply & fixed lamp holder, PVC/polycarbonate type with back plate straight or anfular suitable for batten fittings complete all as specified. and directed.
Supply and fix 15 Watts LED bulb minimum 100 lumen/watt, complete all as specified and directed.
Supplying and fix two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked), concealed, including 4 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified. Note :- (i) Cutting chases for conceal conduit in walls / ceilings and making good to match with the existing surface shall be deemed included in unit rate of this item). (ii) Two runs of 4.0 sq mm cable, one run of PVC conduit and one run of 4 sq mm copper wire shall be measured as one unit length.
Supplying and fix two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC casing and caping (ISI marked) including 4 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified. Note :- (i) Two runs of 4.0 sq mm cable, one run of PVC casing capping and one run of 4 sq mm copper wire shall be measured as one unit length.
Supplying and fix two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC casing and caping (ISI marked) including 6 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified. Note :- (i) Two runs of 6.0 sq mm cable, one run of PVC casing capping and one run of 6 sq mm copper wire shall be measured as one unit length.
S&F in replacement of street light bracket made out of GI pipe light grade 40 mm dia 1.5 mtr long bent to required shape as directed and fixed to pole complete with two coats of aluminium paint over a coat of red oxide primer incl clamps and nut, bolts and washersm, complete all as specified and as directed .
S&F building secuirity light 25 watt endura citylite platinum new generation energy saving & environmental friendly long life versatile presuure die-cast aluminium IP 65/66 roadway luminaire with high power LED source with acrylic cover including taking down old light fittings.complete all as directed by Engineer-in-Charge.
Supply and fix LED lights fitting 1x 18W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, including taking down old light fitting , complete all as specified and as directed ..
Fixing only round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size,complete all as specified and as directed ..
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 2 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed by Engineer-in-Charge.
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed by Engineer-in-Charge.
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact,complete all as directed by Engineer-in-Charge.
Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Triple pole and neutral 415 V, 16 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact, complete all as directed.
Supply and fixed in repairs epoxy powder coated sheet metal enclosure VTPN DB 16 Way double door with Incoming MCCB 250 A, Triple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact, complete all as directed.
Supply and fixed in repairs MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs MCB SPN 6 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs MCB TPN 63 Amps, 'C' series 10kA, 415 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 25 x 4 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall complete shown and as described in electrical plate No.3 of SSR Part I 2009.complete all as specified and directed and testing on completion. Note :- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii)Testing to be carried out by the contractor in presence of Enge-in-Charge, (iii) T&P and testing instrument (meger)to be provided by the contractor at own cost.
Taking down existing unservicebale service earth continuity conductor or main earthing lead and supply and fixed 4 mm dia GI earth lead with clamp, connection complete all as specified.
Taking down ceiling fan any size from its location including disconnecting from ceiling rose, after removing carefully false ceiling wherever necessary and removing blades, opening of fan and cleaning of bush / ball bearing with kerosine oil, filling up ball bearing with grease and mobile oil and changing of capacitor, bush bearing, locking nut, screw, split pin, check nut, rubber real wherever required tightening of stator up and bottom cover in position; washing body, blades, canopies with detergent soap powder; preparation of old painted surfaces by filling cavaties with suiatble filler and applying one coat of spray painting to fan (white or any other approved shade) and writing MES No. etc ,testing and re - hanging fan and false ceiling in position and making electric connection complete all as specified and as dtrected. (Note:- spare wherever required to be replaced shall be deemed included in the unit rates of this item).
Dismantling of exhaust / wall mounted/ table fan of any size from its location including disconnecting wherever necessary and removing blades, opening of fan and cleaning of bush / ball bearing with kerosine oil, filling up ball bearing with grease and mobile oil and changing of capacitor 2.5 mfd locking nut, screw, split pin, washing body, blades, with detergent soap powder; preparation of old painted surfaces by filling cavaties with suiatble filler and applying one coat of spray painting to fan (white or any other approved shade) and writing MES No. etc ,testing nd making electric connection complete all as specified and directed. (Note:- spare wherever required to be replaced shall be deemed included in the unit rates of this item).
Taking down ceiling fan/exhust fan/wall mounted/pedestal fan any size from its location including disconnecting from ceiling rose, after removing carefully false celing wherever necessary and removing blades, rewinding of fan coil with super quality, super enameled copper wire of suitable gauge and heat vernishing and refixing the same in original position including greasing of moving parts and replacement of capacitor 2.5 MFD and testing complete all as specified and directed.
S&F in repair plastic ventilation exhaust fan 200/250 mm sweep with louver and all asssesories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing connected with twin core twisted flexible copper conductor (23/0.0076) of size complete all as specified and directed. Note:- Cost of cutting and making hole for fixing exhaust fan shall be deemed to included in quoated rates. MAKE:-HAVELLS / USHA / ORIENT / BAJAJ.
S&F in repairs 0.5 sqmm two core copper conductor flexible unsheathed multistranded for electric connection of fan to ceiling rose including necessary connection complete all as specified and directed.
S&F in repair MS clamp made out of 25 mm x 6 mm thick flat iron, including nuts and bolts, washers and "S" hook made out of 25 mm dia MS round bar, complete all as specified and directed.
S&F in repair MS down rod for ceiling fan made out of 20mm dia MS tube 1mm thick wall thickness including drilling holes as required complete all as specified and directed.
Taking down geyser of 50/35/25 ltrs capacity from its position after disconnecting connection , opening of geyser to take out inner tank , soldering at two to three places to stop leakage and also scraping , brushing down old paint with emery paper and apply two coats of white paint using spray machine spray painting and including writing of MES No by black paint, complete all as specified and as directed.
Dismantling of unserviceable air release valve and Supply & fix air release valve suitable for 15mm GI pipe complete all as specified and as directed.
Dismantling of unserviceable vaccum release valve from geyser and Supply & fix new vaccum release valve matching to exist one, complete all as specified and as directed.
Dismantling of existing unserviceable apparatus plate and Supply & fix new copper apparatur plate match to the existing one with rubber gasket suitable for 50 ltrs geyser, complete all as specified and as directed.
All as per item No 47 here-in-above but for 25/35 ltrs capacity.complete all as specified and as directed.
S&F in repair glass wool suitable for geyser, complete all as specified and as directed.
Dismantling of existing unserviceable heating element from geyser and Supply & fix new heating element of 1.5 kw 230 volt at including testing and complete connection all as specified and as directed.
All as per item No 50 here-in-above but of 2.0 kw 230 volt element.complete all as specified and as directed.
Dismantling of existing unserviceable thermostat of geyser and Supply & fix new thermostat matching to exist one including all connection,testing etc. complete all as specified and as directed.
Dismantling of existing unserviceable plug top and Supply & fix 15 amp plug top complete with all connection, complete all as specified and as directed.
Dismantling of exist unserviceable bottom cover of geyser with plate and Supply & fix new bottom cover with plate matching to exist one for 25/50 ltrs capacity, complete all as specified and as directed.
Taking down geyser of 25 ltrs to 35 ltrs capacity from its position after disconnecting of existing water connection for taking out the unserviceable inner tank by opening the geyser and Supply & fix new inner tank and refixing in position after assembling and testing, complete all as specified and as directed.
All as per item No 55 here-in-above but of capacity 50 ltrs.complete all as specified and as directed.
Supply & fix in repair PVC Connection pipe 15 mm dia 60 cm long heavy duty with two Nos brass chromium plated union,complete all as specified and as directed.
Supply and fixing in replacment swith flame proof rotary type with termination box in LM-6, 16Amp single pole 250 volts complete all as specified and as directed.
Supply and fixing in replacment of flame proof fan regulator complete all as specified and as directed.
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and as directed.
M/s. S. Chandra Enterprises (BID ID -3153262)
M/s. Rakesh Roshan (BID ID -3152908)
M/S RAM DAS (BID ID -3152949)
M/S SATISH KUMAR SINGH & SONS (BID ID -3153722)
[email protected] (BID ID -3153664)
M/S. KESHAB CHANDRA GHOSH (BID ID -3153645)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .