Tender Value
₹2.4 Cr
EMD Value
₹2.7 L
Closing Date
6 Feb 2026, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SIGNAL
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less ; where V = Advertised value of the tender in crores of Rupees N = Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure- I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited. : Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any work in connection with Signaling Installation and which includes relay wiring and laying & termination of cables. O R Any Signaling work involving Supply, installation, testing & commissioning of AFTC/DAC/MSDAC/UFSBI/BPAC system. Note 1: Tenderer may be required to submit the schedule of those works, Completion/Performance Certificates of which have been submitted by him/her in support of 30/40/60 % (as the case may be) criterion of similar nature of work. Note 2: a. Submission of 'Undertaking by the tenderer' that the equipment for EI or Axle Counter or AFTC or UFSBI shall be procured from RDSO approved sources and installation, testing and commissioning for EI of Axle Counter or AFTC or UFSBI shall also be got done from the same source including after sales support required during the warranty period. AND b. After the award of the contract, MOU with RDSO approved source covering supply of equipment for Axle Counter or AFTC or UFSBI. Installation, testing & commissioning of Axle Counter or AFTC or UFSBI by the same RDSO approved source including after sales support required during the warranty period before supply of equipments is undertaken. AND For Electronic Interlocking (EI) equipments, this should be read as 'The successful bidder shall submit an undertaking from RDSO approved EI OEM, before the supply of material, to confirm compliance with extent RDSO guidelines and to meet contract specific requirements'. Rest of the content remains unchanged.
23 conditions · 14 needing a document upload
PAN card Copy should be enclosed.
Please submit the copy of the registration certificate as applicable, GSTIN certificate should be enclosed.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Firm has to submit authorization letter for uploading documents on IREPS in case he/she is not an authorized person.
Contractors are allowed to make payments against this tender towards tender document cost and earnest money only through only payment modes available ON IREPS portal LIKE net banking, debit card, credit card etc.Manual payments through Demand draft, Banker cheque, Deposit receipts, FDR etc. are not allowed.
Copy of PAN number and GSTIN number should be submitted.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenders shall be treated as NULL & Void.
(i)Tenderers will examine various provisions of the Central Goods and Service Tax Act, 2017(CGST)/Integrated Goods and Service Tax Act,2017(IGST)/Union Territory Goods and Service Tax Act,2017(UTGST)/respective states State Goods and Service Tax Act(SGST) also, as notified by Central/States Govt. and as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit(ITC) likely to be availed by them is duly considered while quoting rates. (ii) The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UTGST/SGST Act to railway immediately after the award of contract, without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority. (iii) In case the successful tenderer is not liable to be registered under CGST/IGST/UTGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism(RCM) and deposit the same to the concerned authority.
Tenderer should go through Annexure 1 & 2 of Tender Notice (attached in Tender Document)for list of documents required to be uploaded along with the offer.
Provision of Digital axle counter in lieu of obsolete Universal axle counters for track circuits over Lucknow Division.
106-Sig-Tender-54-2025-26~NR
106-Sig-Tender-54-2025-26
Open
Works - General
180 Days
Lucknow, Uttar Pradesh
₹0
₹2.7 L
6 Feb 2026
16 Jan 2026
23 Jan 2026
61 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,40,92,189.39 | ||
| — | 27000.00 | — | — | ||
| Excavating and refilling of trench to the level of ground with rammed earth asper Drg. No.(NR/S&T/Con/1.1/97A) so as not to form a drain 0.3 Mtrs wide & 1mtr deep on both side of the station along side the track. It shall confirm to the safe distance as per signalling and cable plan in all type of soil, it also includes clearence of roots of trees and bushes. | — | — | — | 13,77,000 | |
| — | 270.00 | — | — | ||
| Excavating and refilling of trench 0.3 Mtrs wide & 0.8 mtr deep on pitced/stone/bricks paved surface, road/crossing/platform etc. and restoration of surafce to original condition. | — | — | — | 37,662.3 | |
| — | 88000.00 | — | — | ||
| Laying of signalling/Telecom/power cables of different sizes as per attached guidelines (Drg. No.(NR/S&T/Con/1.1/97A) or latest on signalling cable laying and as per cable route plan approved by Railways through trenches, RCC pipe, DWC pipe, GI pipe etc and meggering of cable before and after its laying of all type of outdoor cables. Contractor have to transport cable from any store of LKO division to site carefully. Meggering to be done for each drum separately. Meggering sheets to be supplied and filled up by contractor and submitted to Railways, as per instructions by Consignee. | — | — | — | 5,51,760 | |
| — | 218160.00 | — | — | ||
| Supply and laying of 2nd class bricks in the trench and laying as per Drg. No. (NR/S&T/Con./1.1/97A) or latest and as per instruction of the site Engineer. | — | — | — | 14,68,216.8 | |
| — | 1000.00 | — | — | ||
| Supply and fixing of GI Pipe with 76.6 mm maximum and 75.3 mm minimum outside dia. and 3.6 mm thickness as per specification No. IS:1239 (ISI Mark) make Jindal/Tata/Ajanta or Similar, perforated at a distance of 20 cm or less of required length at culvert/bridges/along the cuttings, suitably concreted at both ends as per drg. No.(NR/S&T/CON/1.4/97 or latest) to be filled with chattered compound. GI pipe clamps of MS flats, bolts and nuts, chattered compound to be supplied by contractor. Inspection - RITES for supply item | — | — | — | 9,18,490 | |
| — | 2500.00 | — | — | ||
| Boring and trenchless cabling along with supply and insertion of HDPE/DWC self lubricated pipes as per RDSO Spec no. RDSO/SPN/204/2011 Ver 1.1 or latest of 120mm nominal dia in the bore at the depth of 1.4 meter to 2.1 meter from formation level (level of earth below ballast) as per drawing and as directed by Engineer Incharge by trenchless technology for laying of signalling /telecom/power cable under track /culvert etc. cable laying covered separately. Inspection-RITES for Supply of DWC/HDPE pipe. The following required coupling arrangement should also be supplied: 1. Suitable snap fit couplers withrubber O ring, 2. Spacers, 3. Tees. 4. Bend. 5. End Cap(1 no. =6mtr ,Straigh tpipe). (A) The cost shall include horizontal boring through any intermediate obstruction, either natural or man made or any boundary etc. (B) The rate is inclusive of all the materials equipment and labour required for during trenchless horizontal boring under the railway track. Nothing extra shall be admissible on any account than the rate quoted above. (C) The Pipeis to be laid underrailway track/road /culvert. All necessary arrangement are to be provideand all precautions are to be end is not deviated from the horizontal level line by more than 250mm in horizontal and vertical direction. (D) The rate shall be inclusive of direction and protection of underground utilities encountered during boring. (E) The payment for boring shall be made only when DWC/HDPE pipe are laid in the bore. | — | — | — | 37,74,400 | |
| — | 10.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of App. Case single as per Drg. No (NR/S&T/ Con/2.7/97). A layer of 3mm of Bitumin compound has to be provided between foundation and location box to prevent ingress of water in the base of location box.All material such as cement, sand, aggregate & anchor bolts shall be supplied by the contractor. Contractor is required to execute all type of repair work of foundation if required during inserting the cable for termination. | — | — | — | 47,427.9 | |
| — | 10.00 | — | — | ||
| Preparation of App. Case single not involving wiring of relays: Preparation & fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, wire and wiring material, non deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn.(as applicable). ARA terminals only shall be supplied by the Railways. | — | — | — | 48,184.9 | |
| — | 27.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of app. Case half as per Drg. No (NR/S&T/Con/2.8/97). A layer of 3mm of Bitumin compound has to be provided between foundation and location box to preventingress of water in the base of location box. All material such as cement, sand, aggregate & anchor bolts shall be suppliedby the contractor. Contractor is required to execute all type of repair work of foundation if required during inserting thecable for termination. | — | — | — | 1,29,826.53 | |
| — | 27.00 | — | — | ||
| Preparation of App. Case half not involving wiring of relays: Preparation & fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, wire and wiring material, non deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn.(as applicable). ARA terminals only shall be supplied by the Railways. | — | — | — | 92,358.9 | |
| — | 155.00 | — | — | ||
| Supply of Relays - Miniature, Plug-in Type, M to C, DC Neutral Line AC Immunized Relay, Style QNA1, 24 V DC, 8F-8B Contact, Code ABDGH/ABDFH Spec: BRS:931A; IRS S 34 ; IRS S 23 ;IRS S 60-78 , STR: SIQ 0420 Ver.1 or latest. Inspection : RDSO | — | — | — | 7,53,678.2 | |
| — | 5.00 | — | — | ||
| Supply of Standard Tool Kit for Installation, testing and maintenance of Digital Axle counter system consisting of: i) Pure Sine wave Digital multimeter Fluke make or similar Model No. 859 CF or Equivalent =01 No. ii):-Train Simulator (Model TS 267 P)=01No. iii):- Extender Card No. 557-=01 No. iv) Dummy Wheel=01No v) Spanners:- a) Ring spanner 17-19, 24-26 one each. b) Open End spanner 17-19, 24-26= 01 each c)Socket Spanner with handle=01 No. vi)Screw Driver No902=01No.vii)Screw Driver No935=01No viii)Marking Jig for Drilling=01 No. ix) Torque Wrench=01 No. x)Dummy Load= 01 No. Inspection by - RITES | — | — | — | 5,71,420.3 | |
| — | 2.00 | — | — | ||
| Supply of electronic Cable Route Tracer of reputed make 3M Dynatel/ Aplab/ Stanley C-Scope/ RD or similar reputed make along with TC & GC, As per RDSO recomendation, consist of (i) Cable avoidance tool digital under ground cable & pipe locating receiver and cable avoidance tool. (ii) signal generator of signal transmission capacity upto 12W. (iii) Signal lamp accessory (iv) Carry bag . Item to be supplied after successful demonstration and approval of Railways.Visual Inspection by RITES against test certificate & guarantee certifcate of OEM. | — | — | — | 6,87,842.14 | |
| — | 3.00 | — | — | ||
| Supply of cable fault locator for underground mettalic S&T cable of reputed make 3M Dynatel /Andig/Aplab/ Stanley /RD or similar reputed make specification similar to (Test signal output1/2 Sine, Pulse width 5nsec to 2500 nsec, Max Range:15000m, Filter cut-off Frequency:150 kHz (High Pass Filter), Gain:0 to 63dB), RDSO/TEC recommended.Item to be supplied after successful demonstration and approval of railways. Visual Inspection by RITES against test certificate & guarantee certifcate of OEM | — | — | — | 11,28,713.49 | |
| — | 10.00 | — | — | ||
| Supply of Relays - Miniature, Plug-in type, M to C, DC Neutral Line Relay, 24V DC 1000 Ohm , ACI Style- QNA1K, 6F-6B Contact, Code CDEKY/CDEKY Spec: BRS:931A & STs/E/Relays/UEA/PI dtd 30.05.97 Annex II & IRS:S-23, 34 & 60 STR: SIQ 0420 Ver.1 or latest. Inspection : RDSO | — | — | — | 65,022.1 | |
| — | 100.00 | — | — | ||
| Supply of Relays - Miniature, Plug in Type, M to C, DC Neutral ,Track Relay, ACI, Style QTA2, 9 Ohm, 2F-1B Contact, Code FGHKX Spec: BRS:939A & 966 (Appx F2) & IRS:S-23, S34 & 60, STR: SIQ 0420 Ver.1 or latest. Inspection- RDSO | — | — | — | 5,85,757 | |
| — | 100.00 | — | — | ||
| Supply of Track Feed Charger 110VAC/2-4-6 V DC /10 Amp as per RDSO spec no. 89/2013(Amdt-1) or latest from RDSO approved firm. Inspection -RDSO. | — | — | — | 4,81,608 | |
| — | 300.00 | — | — | ||
| Supply of Sec. cell low maintenance 2V/80 AH conforming to IRS S-88/2004, Rev.1 or latest with micro porous vent plugs cum floats with inter cell connectors, nuts,bolts, washers etc. Inspection by- RDSO. | — | — | — | 10,08,273 | |
| — | 500.00 | — | — | ||
| Charging of 80/120AH secondary batteries (with contractor's charging equipment) as per standard procedure. All the charging materials i.e. sulphuric acid confirming to latest IRS specifications and distilled water confirming to latest specifications will be supplied by the contractor. This also includes installation of secondary batteries, their interconnections & writing work as per directions of site Engineer. | — | — | — | 1,24,895 | |
| — | 200.00 | — | — | ||
| Supply and installation of earth electrodes as per std.practice. The item includes digging of pitin earth, 3 Mtrs. deepand fixing earth electrode pipe.Casting of cement concrete enclosures as per drg. No.(NR/S&T/CON/6.4/97) or latest. The soil treatment shall be done as per std.practice. The item includes provision of mild steel flat of size35mm x 6mm (as per IRSEM) and nut bolted connection of MS flat with earth electrode. The other end of mild steel flat to be connected to block instrument,cable sheath of power equipment, signal base, apparatus case, CT rack / relay racks, other equipments as per the instruction of Engr. at site & IRSEM. Earth connection Signal & location boxes to be done Drg.No. 19-D6 of IRSEM App II or latest. Complete materials such as earth electrodes as per Drg. No. (NR/S&T/CON/6.3/97)or latest, cement, wiring material, nutbolt for connection & mild steel flat of size minimum 35mm x6mm or 210 sqm as per SEM etc. to be supplied by the contractor. Inspection by - RITES for supply of earth electrode. | — | — | — | 7,55,408 | |
| — | 167.00 | — | — | ||
| Supply, installation & commissioning of maintenance free earth suitable kit as per RDSO specification RDSO/SPN/197/2008 and Drg No. SDO/RDSO/E&B/002 dated 19.09.2008 and as per RDSO TAN letter No- RDSO-SIGEnB (GEN)/1/2020 dated 30.06.2025 or latest with latest amendments. Earthing kit consisting :- 1. Earthing electrode of 17.0 mm dia 3m long- 01 No. 2. Main equi-potential Earth Busbar (MEEB) (300mm x 25mm X 6mm minim.) - 01 No. 3. Sub equi-potential Earth Busbar (SEEB) (150mm X 25mm X 6mm minim.) 01No. 4. Earth Enhancing compound- 30-35 Kg (minimum) 5. Multi-strand single core PVC insulated copper cable 10 Sq. mm as per IS:694 used to connect individual equipment to SEEB Minim. 10 mtrs or as per site requirement or as per Purchaser Railway 6. Multi-strand single core PVC insulated copper cable 16 Sq. mm as per IS:694 used to connect SEEB to MEEB Minim. 10 mtrs or as per site requirement or as per Purchaser Railway 7. Multi-strand single core PVC insulated copper cable 16 Sq. mm as per IS:694 used to connect SPD to MEEB Minim. 10 mtrs or as per site requirement or as per Purchaser Railway 8. Multi- strand Single core PVC insulated copper cable 35 sq mm as per IS:694 (Duplicated) used to connect MEEB to main earth electrode Minim. 10 mtrs or as per site requirement or as per Purchaser Railway 9. Copper tape or solid copper round conductor of 25x2 mm or 8 mm dia used to connect Main earth pit to other earth pit in case of loop earth as per site requirement. 10. Copper strip of size 200mm X 25mm X 6mm to be exothermically welded to earth electrode - 1 No. 11. Exothermic Weld Material & Mould as per site requirement. This includes:- Provision of earth connection from MEEB/SEEB to S&T equipment i.e. cable sheath, apparatus case, BPAC, Axle counter, IPS, Data logger etc. with PVC earth wire of Size 16/10 Sq mm. through copper lugs of suitable size. PVC earth wire for connection of MEEB/SEEB to equipment shall be supplied by railway, Note: At certain locations, it may not be possible to achieve earth resistance of less than 1.0 ohm with one earth electrode/pit due to soil resistivity. In such cases, provision of loop earth consisting of more than one earth pit shall be done for interconnection of two earth pits copper tape of size 25 X 2 Sq. mm shall be provided by the contractor. The number of pits required shall be decided based on the resistance achieved for the earth pits already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as separate earth. Supply by RDSO approved Firm, Installation of MFE is to be done by OEM as per standard procedure and pre commissioning checklist to be submitted duly signed by OEM representative and Railway Representative. Inspection: RDSO for supply portion. | — | — | — | 43,61,144.88 | |
| — | 10.00 | — | — | ||
| Earth ground resistance leakage current tester (clamp on ground resistance tester) similar to MECO make of model no. 4680BLC. Warranty: Minimum one year. Make: MECO, FLUKE, MEGGER, HIOKI, METRAVI or similar. Inspection - Consignee | — | — | — | 3,48,363.6 | |
| — | 50.00 | — | — | ||
| Supply of Portable digital auto range multi-meter clamp type with capacity to measure mA AC/DC current with accuracy of (3% of reading) AC/DC upto 80Amp(AC/DC), 600V(AC/DC) and 0.1 ohms- 40M ohms, suitable for measurement of Freq., capacitance, complete with Manual, leads, battery and holster etc. Inspection - Consignee. | — | — | — | 4,71,477.5 | |
| — | 48.00 | — | — | ||
| Supply and provision of straight through joints with the help of thermo shrink jointing (TSF) kit as per specifications, drawings and stipulations of tender documents and as per approved cable route plan at various locations for 06 quad/04 Quad cable. Jointing kit to be supplied as per RDSO Specification IRS:TC 77/2012 (Rev-3) or latest amendments. Inspection :Consignee for supply item | — | — | — | 3,92,758.08 | |
| — | 10.00 | — | — | ||
| Automatic Media Changeover Device supporting STM (E1 interface) (1U height / 19" rack mountable) & 02 interface (02 (V.21/V.23) supporting 2W/4W (each port configurable) & two quad Protection Ports (2W/4W) for individual two V.21 /V.23 (E&M interfaces) suitable for LVCD /Digital Axle Counter / UFSBI /Control Phone connectivity on dedicated E1 (STM) with Automatic Change Over features (E1 to Quad), Quad health Indications for each (V.21/V.23), E&M interface & Four Potential Free contacts as required by Railways, Audible failure uplink resettable buzzer & DC power supply supporting 18VDC to 72 VDC make Model : Teamengineer FABIO or equivalent. better make & model will be accepted. Inspection RITES for supply portion. | — | — | — | 8,17,244.6 | |
| — | 5.00 | — | — | ||
| Supply, installation, testing and commissioning of failure analysis system along with HP LaserJet 1020 Plus Laser Printer or similar/better for feeding the information in Hindi and English. System should be standard make Lenovo C460 make or latest. The system should be of min. 11th generation or latest, pre-loaded with original licenced windows 10 & MS office or latest, Intel core i5 processor, RAM 8 GB, Storage NVMe SSD capacity of minimum 500 GB,storage type SSD, Monitor LCD, Full HD screen size of minimum 21.5 inches, all accessory i.e. optical mouse, Keyboard ,UPS etc reputed make as per requirement. System with better specification will also be acceptable. Inspection: Consignee for supply portion. | — | — | — | 4,26,696.45 | |
| — | 20.00 | — | — | ||
| Supply of Digital insulation Tester (Megger) 100V-1000V DC , Output Voltage-100V, 250V,500V, 1000V DC, Accuracy +- 5% , Resistance Range 200 M Ohm- 2000 M Ohm Accuracy +- 2%, Make Motwani , Philips, Rishabh, or similar reputed make. Inspection - Consignee | — | — | — | 1,44,057.8 | |
| — | 32.00 | — | — | ||
| Casting, concreting, curing of foundations of size (400mmx300mm) at surface and 1000mm deep and erection of retroreflective SLB/BSLB/SB/ calling on boards/Goods Warning Board/Passanger Warning Board as per Drg. No. NR/S&T/CON/7.4/97 or latest & provisions of SEM. It includes supply of retroreflective SLB/BSLB/SB/ calling on boards/Goods Warning Board/Passanger Warning Board. The SLB/BSLB shall be as per approved Drg. No.SA-2373 or latest. Calling on board should be as per Drg NO: NR/S&T/D&D/01/2022 or latest. Inspection by : Consignee for supply portion | — | — | — | 3,29,441.92 | |
| — | 30000.00 | — | — | ||
| Loading, Leading & unloading of materials from store to another store as per instruction of consignee. All the material to be transported carefully without damage. Contractor have to do proper stacking of material and prepare list of material. | — | — | — | 1,82,100 | |
| — | 1350.00 | — | — | ||
| Fabrication, supply and fixing of concrete cable marker as per RDSO drg. No. SDO/Cable Laying/020, dt.31.10.11 or as per SEM or latest drawing given by engineer The marker shall be fixed at various places of cable route as per instruction of Eng. at site. Inspection at site by Consignee. | — | — | — | 20,10,960 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .